Advertisement for orthosearch.org.uk
Results 21 - 40 of 69
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 451 - 451
1 May 1968
Piggot. J


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 378 - 379
1 May 1999
Dickson RA


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 346 - 348
1 Aug 1975
Dandy DJ Jackson RW

A study has been made of 800 consecutive arthroscopic examinations of the knee with special emphasis on the changes in management that resulted. Of 614 knees that would have been operated upon if arthroscopy had not been available, open operation was avoided in 32 per cent, a different operation was done or planned in 27 per cent, and there was no important change in the remaining 41 per cent. Of 186 knees that would have been treated conservatively if arthroscopy had not been available, the examination resulted in some immediate benefit to 30 per cent of the patients. There were no wound infections after arthroscopy alone, and the known incidence of incorrect interpretation was 1.4 per cent.


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 2 | Pages 397 - 398
1 May 1974
Waugh W


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 310 - 322
1 May 1972
Jackson RW Abe I

1. A critical analysis of the findings in 200 knees examined by arthroscopy at least one year previously has been carried out to assess its value in the management of a wide variety of disorders.

2. Arthroscopy is a practical and valuable procedure with minimal associated morbidity or complications.

3. The increased accuracy of diagnosis helps to avoid unnecessary operations and to base methods of treatment on a better knowledge of the pathology.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 388 - 388
1 May 1972
Devas MB


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 775 - 775
1 Nov 1971
James JIP


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 200 - 200
1 Feb 1970
James JIP


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 183 - 189
1 Mar 1997
Pihlajamäki H Myllynen P Böstman O

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions.

There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation.

Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 175 - 179
1 May 1975
Brown I

Displacement and blurring of the soft-tissue shadows about the hip has been described in several conditions, particularly in transient synovitis. A study was made between such displacements and the posture commonly adopted by an "irritable hip". Examination of radiographs of normal hips, and of those in cases of transient synovitis and Perthes' disease showed that the appearance of "capsular swelling" is related to the position of lateral rotation and abduction. This was confirmed by anatomical dissections of the lateral plane, which appears to be an intermuscular plane lying anterior to the hip, and an explanation is given for the blurring which may accompany its lateral displacement. "Capsular swelling" appears to be a radiological artefact.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 266 - 273
1 May 1968
Parsons DW Seddon HJ

1. The treatment of contractures at the hip secondary to poliomyelitis by Soutter's muscle slide or by Yount's fasciotomy gives excellent results. So does high femoral osteotomy, but it is not superior to the other two and should therefore be kept in reserve as a supplementary operation for the completion of correction of a deformity so gross as not to be wholly remediable by division of the soft parts.

2. Subluxation of the hip occurs only if the paralysis comes on during the first eighteen months of life and is a product not of severe paralysis but of unbalanced and often slight weakness of muscles. Correction of the invariable valgus deformity of the femoral neck by osteotomy is followed by relapse; acetabuloplasty too is unreliable. The most promising remedy seems to be some form of acetabuloplasty combined with transplantation of an iliopsoas of adequate strength into the greater trochanter. The indications for arthrodesis are few, but the results of this operation are good.

3. In the few patients with abductor weakness and little else the dipping gait may be abolished by iliopsoas transplantation.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 1 | Pages 110 - 113
1 Feb 1962
Pledger HG

1. A patient is described who developed hypothermia shortly after being rendered tetraplegic by a fracture of the cervical spine.

2. The causes and prevention of hypothermia or hyperpyrexia in tetraplegia are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 408 - 408
1 Aug 1975
Petri C


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 3 | Pages 462 - 464
1 Aug 1974
Goncalves D

Dysfunction of the distal radio-ulnar joint caused by traumatic, congenital and inflammatory onditions is usually treated by excision of the head of the ulna. This operation can induce ulnar carpal shift, with complications such as instability with poor grip, pain and clumsiness of the wrist, if the lower articular surface of the radius is normally inclined, or overinclined towards the ulna.

These complications can be avoided by use of an operation producing pseudarthrosis of the distal part of the ulna, with fusion of the radio-ulnar joint (Lauenstein) if there is dislocation, radio-ulnar discrepancy or arthritis, or without fusion (Baldwin) if the joint, in spite of keeping normal articular surfaces, has its movement blocked by malunion of a radial fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 3 | Pages 399 - 401
1 Aug 1953
Pertrie JG



Bone & Joint Open
Vol. 4, Issue 4 | Pages 250 - 261
7 Apr 2023
Sharma VJ Adegoke JA Afara IO Stok K Poon E Gordon CL Wood BR Raman J

Aims. Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time assessment. Here we show that miniaturized handheld near-infrared spectroscopy (NIRS) scans, operated via a smartphone, can assess structural human bone properties in under three seconds. Methods. A hand-held NIR spectrometer was used to scan bone samples from 20 patients and predict: bone volume fraction (BV/TV); and trabecular (Tb) and cortical (Ct) thickness (Th), porosity (Po), and spacing (Sp). Results. NIRS scans on both the inner (trabecular) surface or outer (cortical) surface accurately identified variations in bone collagen, water, mineral, and fat content, which then accurately predicted bone volume fraction (BV/TV, inner R. 2. = 0.91, outer R. 2. = 0.83), thickness (Tb.Th, inner R. 2. = 0.9, outer R. 2. = 0.79), and cortical thickness (Ct.Th, inner and outer both R. 2. = 0.90). NIRS scans also had 100% classification accuracy in grading the quartile of bone thickness and quality. Conclusion. We believe this is a fundamental step forward in creating an instrument capable of intraoperative real-time use. Cite this article: Bone Jt Open 2023;4(4):250–261