We retrospectively assessed the value of identifying
impinging osteophytes using dynamic computer simulation of CT scans
of the elbow in assisting their arthroscopic removal in patients
with osteoarthritis of the elbow. A total of 20 patients were treated
(19 men and one woman, mean age 38 years (19 to 55)) and followed
for a mean of 25 months (24 to 29). We located the impinging osteophytes
dynamically using computerised three-dimensional models of the elbow
based on CT data in three positions of flexion of the elbow. These
were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively
to 9° (0° to 25°) post-operatively, and the mean flexion improved
from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively.
The mean Mayo Elbow Performance Score improved from 62 (30 to 85)
to 95 (70 to 100) post-operatively. All patients had pain in the
elbow pre-operatively which disappeared or decreased post-operatively.
According to their Mayo scores, 14 patients had an excellent clinical
outcome and six a good outcome; 15 were very satisfied and five
were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients
with osteoarthritis of the elbow. Cite this article:
We undertook a study on eight arms from fresh cadavers to define the clinical usefulness of the lesser sigmoid notch as a landmark when reconstructing the length of the neck of the radius in replacement of the head with a prosthesis. The head was resected and its height measured, along with several control measurements. This was compared with The results were highly reproducible with intra- and interclass correlations of >
0.99. The mean difference between the measurement on the excised head and the distance from the stump of the neck and the lesser sigmoid notch was −0.02 mm (−1.24 to +0.97). This difference was not statistically significant (p = 0.78). The proximal edge of the lesser sigmoid notch provides a reliable landmark for positioning a replacement of the radial head and may have clinical application.
We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone.
The June 2014 Trauma Roundup360 looks at: BMP use increasing wound complication rates in trauma surgery; can we predict re-admission in trauma?; humeral bundle nailing; how best to treat high-angle femoral neck fractures?; hyperglycaemia and infection; simultaneous soft-tissue and bony repair in terrible triad injuries; metaphyseal malunion in the forearm leading to function restrictions; delayed fixation of the distal radius: not a bad option; and fasciotomies better with shoelaces
The August 2012 Shoulder &
Elbow Roundup360 looks at: platelet-rich fibrin matrix and the torn rotator cuff; ultrasound, trainees, and ducks out of water; the torn rotator cuff and conservative treatment; Bankart repair and subsequent degenerative change; proprioception after shoulder replacement; surgery for a terrible triad, with reasonable short-term results; and the WORC Index.
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The use of passive stretching of the elbow after
arthrolysis is controversial. We report the results of open arthrolysis in
81 patients. Prospectively collected outcome data with a minimum
follow-up of one year were analysed. All patients had sustained
an intra-articular fracture initially and all procedures were performed
by the same surgeon under continuous brachial plexus block anaesthesia
and with continuous passive movement (CPM) used post-operatively
for two to three days. CPM was used to maintain the movement achieved
during surgery and passive stretching was not used at any time.
A senior physiotherapist assessed all the patients at regular intervals.
The mean range of movement (ROM) improved from 69° to 109° and the
function and pain of the upper limb improved from 32 to 16 and from
20 to 10, as assessed by the Disabilities of the Arm Shoulder and
Hand score and a visual analogue scale, respectively. The greatest
improvement was obtained in the stiffest elbows: nine patients with
a pre-operative ROM <
30° achieved a mean post-operative ROM
of 92° (55° to 125°). This study demonstrates that in patients with
a stiff elbow after injury, good results may be obtained after open
elbow arthrolysis without using passive stretching during rehabilitation.
We undertook this study to determine the minimum
amount of coronoid necessary to stabilise an otherwise intact elbow
joint. Regan–Morrey types II and III, plus medial and lateral oblique
coronoid fractures, collectively termed type IV fractures, were
simulated in nine fresh cadavers. An electromagnetic tracking system
defined the three-dimensional stability of the ulna relative to
the humerus. The coronoid surface area accounts for 59% of the anterior articulation.
Alteration in valgus, internal and external rotation occurred only
with a type III coronoid fracture, accounting for 68% of the coronoid
and 40% of the entire articular surface. A type II fracture removed
42% of the coronoid articulation and 25% of the entire articular
surface but was associated with valgus and external rotational changes
only when the radial head was removed, thereby removing 67% of the
articular surface. We conclude that all type III fractures, as defined here, are
unstable, even with intact ligaments and a radial head. However,
a type II deficiency is stable unless the radial head is removed.
Our study suggests that isolated medial-oblique or lateral-oblique
fractures, and even a type II fracture with intact ligaments and
a functional radial head, can be clinically stable, which is consistent
with clinical observation.
Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7). There were no failures (movement of >
2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of >
2 mm at 450 N. FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken
Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion <
30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe extra-articular contracture of the elbow. This retrospective study included 26 patients (15 males and 11 females) with a mean age of 30 years (12 to 60). The mean duration of stiffness was 9.1 months (5.4 to 18) with mean follow-up of 5.2 years (3.5 to 9.4). The mean pre-operative arc of movement was 15.6° (0° to 30°), with mean pre-operative flexion of 64.1° (30° to 120°) and mean pre-operative extension of 52.1° (10° to 90°). Post-operatively the mean arc improved to 102.4° (60° to 135°), the mean flexion improved to 119.1° (90° to 140°) and mean extension improved to 16.8° (0° to 30°) (p <
0.001). The Mayo elbow score improved from a mean of 45 (30 to 65) to 89 (75 to 100) points, and 13 had excellent, nine had good, three had fair and one had a poor result. We had one case of severe instability and one wound dehiscence which responded well to treatment. One case had deep infection with poor results which responded well to treatment. Our findings indicate that this method is very effective in the treatment of severe elbow contracture; however, a randomised controlled study is necessary for further evaluation.
We reviewed 15 patients, nine girls and six boys, with chronic anterior dislocation of the radial head which was treated by ulnar osteotomy, external fixation and open reconstruction of the elbow joint but without repair of the annular ligament. Their mean age was 9.5 years (5 to 15) and the mean interval between the injury and reconstruction was 22 months (2 months to 7 years). All radial heads remained reduced at a mean follow-up of 20 months (6 months to 5 years). Normal ranges of movement for flexion, extension, pronation and supination were unchanged in 96.1% (49/51) and worse in 3.9% (2/51). Limited ranges of movement were improved in 77.8% (7/9), unchanged in 11% (1/9) and further decreased in 11% (1/9).There were two superficial pin-track infections and two cases of delayed union but with no serious complications. Reconstruction of the radiocapitellar joint is easier using external fixation since accurate correction of the ulna can be determined empirically and active functional exercises started immediately. Only patients with a radial head of normal shape were selected for treatment by this method.
We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15). Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04). Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability.
Most patients with a nightstick fracture of the
ulna are treated conservatively. Various techniques of immobilisation or
early mobilisation have been studied. We performed a systematic
review of all published randomised controlled trials and observational
studies that have assessed the outcome of these fractures following
above- or below-elbow immobilisation, bracing and early mobilisation.
We searched multiple electronic databases, related bibliographies and
other studies. We included 27 studies comprising 1629 fractures
in the final analysis. The data relating to the time to radiological
union and the rates of delayed union and nonunion could be pooled
and analysed statistically. We found that early mobilisation produced the shortest radiological
time to union (mean 8.0 weeks) and the lowest mean rate of nonunion
(0.6%). Fractures treated with above- or below-elbow immobilisation
and braces had longer mean radiological times to union (9.2 weeks,
9.2 weeks and 8.7 weeks, respectively) and higher mean rates of
nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically
significant difference in the rate of non- or delayed union between
those treated by early mobilisation and the three forms of immobilisation
(p = 0.142 to p = 1.000, respectively). All the studies had significant
biases, but until a robust randomised controlled trial is undertaken
the best advice for the treatment of undisplaced or partially displaced
nightstick fractures appears to be early mobilisation, with a removable
forearm support for comfort as required. Cite this article: