Advertisement for orthosearch.org.uk
Results 21 - 40 of 81
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 425 - 428
1 May 1995
Eyres K Brooks A Stanley D

We have reviewed 12 fractures of the coracoid process. In two of these patients the fracture extended into the body of the scapula and resulted in displacement of the glenoid. In some cases, there were associated acromioclavicular and glenohumeral dislocations or fractures of the clavicle and the acromion. Two patients required internal fixation to restore congruence of the glenoid; the others were treated conservatively with success. We present a new classification of coracoid fractures which helps in their management


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 887 - 890
1 Aug 2003
Deie M Ochi M Sumen Y Yasumoto M Kobayashi K Kimura H

We investigated the clinical outcome of a reconstructive procedure of the medial patellofemoral ligament for the treatment of habitual or recurrent dislocation of the patella in four children (6 knees), with a minimum follow-up of four years. The technique involves transfer of the tendon of semitendinosus to the patella using the posterior one-third of the femoral insertion of the medial collateral ligament as a pulley. There was no recurrence of dislocation after surgery. The mean Kujala score at follow-up was 96.3 points. Radiological assessment showed that the congruence angle, the tilt angle and the lateral shift radio were restored to normal. The lateral and medial stress shift ratios and the Insall-Salvati ratio remained abnormal. We conclude that this technique can be recommended for the treatment of habitual or recurrent patellar dislocation in children, although hypermobility and patella alta are not fully corrected


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 9 - 23
1 Jan 1999
McCredie J Willert H

The pathogenesis of longitudinal reduction deformities of the limbs, or dysmelia, is still a matter of debate. Their morphological pattern was defined from a large collection of radiographs of children with dysmelia following the thalidomide disaster. We compared radiographs of 378 of these limbs with the sclerotomes which are areas of segmental sensory innervation of the limb skeleton defined by the radiation of referred pain. The pattern of dysmelia matched the sclerotomes closely in 279 limbs (73.5%). The principles of skeletal reduction in dysmelia are explained by the arrangement of the sclerotomes. The congruence between two separate and independent data sets shows that both patterns are expressions of the underlying segmental sensory innervation of the skeleton, and that the sensory nervous system is involved in the process of limb morphogenesis and teratogenesis


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 67 - 70
1 Jan 1999
Tornetta P

To assess the stability of the hip after acetabular fracture, dynamic fluoroscopic stress views were taken of 41 acetabular fractures that met the criteria for non-operative management. These included roof arcs of 45°, a subchondral CT arc of 10 mm, displacement of less than 50% of the posterior wall, and congruence on the AP and Judet views of the hip. There were three unstable hips which were treated by open reduction and internal fixation. The remaining 38 fractures were treated non-operatively with early mobilisation and delayed weight-bearing. At a mean follow-up of 2.7 years, the results were good or excellent in 91% of the cases. Three fair results were ascribed to the patients’ other injuries. Dynamic stress views can identify subtle instability in patients who would normally be considered for non-operative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 822 - 824
1 Sep 1993
Grelsamer R Bazos A Proctor C

We describe the radiographic measurement of the angle of tilt of the patella and relate it to malalignment of the extensor mechanism. The tilt angle is defined as the angle subtended by a line joining the medial and lateral edges of the patella and the horizontal. The radiograph (Merchant type) is taken with the foot pointing up, the lower edge of the film parallel to the ground, and the knee at 30 degrees flexion. The mean tilt angle of a group of patients with signs and symptoms suggesting patellofemoral malalignment was 12 degrees (+/- 6 degrees); in a similar group of control subjects it was 2 degrees (+/- 2 degrees) (p < 0.01). Tilting of 5 degrees was taken to be the limit of normal. For the detection of patellar malalignment, the tilt angle was almost as specific as the congruence angle (92% v 99%) but more sensitive (85% v 25%) and more accurate (89% v 62%)


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 788 - 792
1 Nov 1989
Kujala U Osterman K Kormano M Nelimarkka O Hurme M Taimela S

Magnetic resonance imaging was used to analyse the patellofemoral relationships during the first 30 degrees of knee flexion in women with recurrent patellar dislocation. The patellofemoral joints were imaged both sagittally and axially with the knee flexed 0 degrees, 10 degrees, 20 degrees, and 30 degrees. At the beginning of knee flexion the sulcus angle was greater than in unaffected women, the lateral patellofemoral angle was smaller, the patella displaced further laterally, tilted more laterally and the congruence angle was directed more laterally. At 30 degrees of knee flexion these differences were less marked than at 0 degree to 10 degrees. Logistic regression analysis showed that the sulcus angle at 10 degrees of knee flexion was the most diagnostic feature, indicating that there is an anatomical predisposition to recurrent dislocation and that pathological patellar tracking starts from the beginning of flexion. Traditional sunrise radiographic films taken at 25 degrees to 30 degrees knee flexion clearly miss diagnostically important information


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims

The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs).

Methods

At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1421 - 1427
1 Aug 2021
Li J Lu Y Chen G Li M Xiao X Ji C Wang Z Guo Z

Aims

We have previously reported cryoablation-assisted joint-sparing surgery for osteosarcoma with epiphyseal involvement. However, it is not clear whether this is a comparable alternative to conventional joint arthroplasty in terms of oncological and functional outcomes.

Methods

A total of 22 patients who had localized osteosarcoma with epiphyseal involvement around the knee and underwent limb salvage surgery were allocated to joint preservation (JP) group and joint arthroplasty (JA) group. Subjects were followed with radiographs, Musculoskeletal Tumor Society (MSTS) score, and clinical evaluations at one, three, and five years postoperatively.


Bone & Joint 360
Vol. 10, Issue 4 | Pages 27 - 30
1 Aug 2021


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1158 - 1166
14 Sep 2020
Kaptein BL den Hollander P Thomassen B Fiocco M Nelissen RGHH

Aims

The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs).

Methods

A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.


Bone & Joint 360
Vol. 10, Issue 1 | Pages 38 - 41
1 Feb 2021


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims

The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size.

Methods

This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 868 - 873
1 Jul 2020
Yang G Dai Y Dong C Kang H Niu J Lin W Wang F

Aims

The purpose of this study was to explore the correlation between femoral torsion and morphology of the distal femoral condyle in patients with trochlear dysplasia and lateral patellar instability.

Methods

A total of 90 patients (64 female, 26 male; mean age 22.1 years (SD 7.2)) with lateral patellar dislocation and trochlear dysplasia who were awaiting surgical treatment between January 2015 and June 2019 were retrospectively analyzed. All patients underwent CT scans of the lower limb to assess the femoral torsion and morphology of the distal femur. The femoral torsion at various levels was assessed using the a) femoral anteversion angle (FAA), b) proximal and distal anteversion angle, c) angle of the proximal femoral axis-anatomical epicondylar axis (PFA-AEA), and d) angle of the AEA–posterior condylar line (AEA-PCL). Representative measurements of distal condylar length were taken and parameters using the ratios of the bianterior condyle, biposterior condyle, bicondyle, anterolateral condyle, and anteromedial condyle were calculated and correlated with reference to the AEA, using the Pearson Correlation coefficient.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 811 - 821
1 Jun 2018
Fu K Duan G Liu C Niu J Wang F

Aims

The aim of this study was to investigate the changes in femoral trochlear morphology following surgical correction of recurrent patellar dislocation associated with trochlear dysplasia in children.

Patients and Methods

A total of 23 patients with a mean age of 9.6 years (7 to 11) were included All had bilateral recurrent patellar dislocation associated with femoral trochlear dysplasia. The knee with traumatic dislocation at the time of presentation or that had dislocated most frequently was treated with medial patellar retinacular plasty (Group S). The contralateral knee served as a control and was treated conservatively (Group C). All patients were treated between October 2008 and August 2013. The mean follow-up was 48.7 months (43 to 56). Axial CT scans were undertaken in all patients to assess the trochlear morphological characteristics on a particular axial image which was established at the point with the greatest epicondylar width based on measurements preoperatively and at the final follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 3 - 7
1 Jun 2019
Patel NG Waterson HB Phillips JRA Toms AD


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims

The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function.

Materials and Methods

Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips).


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 76 - 82
1 Jan 2018
Benjamin B Pietrzak JRT Tahmassebi J Haddad FS

Aims

The outcome of total knee arthroplasty (TKA) is not always satisfactory. The purpose of this study was to identify satisfaction and biomechanical features characterising the gait of patients who had undergone TKA with either an anatomical single radius design or a medial pivot design. We hypothesised that the latter would provide superior function.

Patients and Methods

This is a study of a subset of patients recruited into a prospective randomised study of a single radius design versus a medial pivot design, with a minimum follow-up of one year. Outcome measurements included clinical scores (Knee Society Score (KSS) and Oxford Knee Score (OKS)) and gait analysis using an instrumented treadmill.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).