Vol. 99-B, Issue 6 | Pages 732 - 740
1 Jun 2017
Meermans G Konan S Das R Volpin A Haddad FS

Aims

The most effective surgical approach for total hip arthroplasty (THA) remains controversial. The direct anterior approach may be associated with a reduced risk of dislocation, faster recovery, reduced pain and fewer surgical complications. This systematic review aims to evaluate the current evidence for the use of this approach in THA.

Materials and Methods

Following the Cochrane collaboration, an extensive literature search of PubMed, Medline, Embase and OvidSP was conducted. Randomised controlled trials, comparative studies, and cohort studies were included. Outcomes included the length of the incision, blood loss, operating time, length of stay, complications, and gait analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 168 - 171
1 Mar 1984
McElwaine J Colville J

A study of excision arthroplasty (Girdlestone's pseudarthrosis) for infected total hip replacements is presented. Twenty-two patients were reviewed with a minimum follow-up of one year. Reduction in pain was significant but the functional results were poor. Factors contributing to poor function were old age, poor medical condition and arthritis of the contralateral hip; these were in addition to the gross instability resulting from the pseudarthrosis. The patients were easily fatigued and dependent on external supports; calipers were found to be unacceptable. The symptoms after excision arthroplasty are compared with those before the original hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 240 - 246
1 Mar 1997
Emery DFG Clarke HJ Grover ML

Fifty-seven Stanmore Total Hip replacements were implanted between 1974 and 1986 in patients under the age of 50 years. We have reviewed the results in terms of survivorship and function, and assessed the reasons for revision. Of the original 57, 22 (39%) have been revised at an average of 12 years from implantation, usually for aseptic loosening. Most of them had originally been implanted for osteoarthritis. Prostheses cemented with second-generation techniques have lasted significantly longer, and acetabular loosening emerged as a continuing problem. The overall survivorship was 90% at 10 years and 68% at 15 years. Cemented hip replacement appears to be a viable option in younger patients and the Stanmore implant is comparable with other cemented prostheses in this age group


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 168 - 172
1 Feb 2006
Mayr E de la Barrera JM Eller G Bach C Nogler M

In navigated total hip arthroplasty, the pelvis and the femur are tracked by means of rigid bodies fixed directly to the bones. Exact tracking throughout the procedure requires that the connection between the marker and bone remains stable in terms of translation and rotation. We carried out a cadaver study to compare the intra-operative stability of markers consisting of an anchoring screw with a rotational stabiliser and of pairs of pins and wires of different diameters connected with clamps. These devices were tested at different locations in the femur. Three human cadavers were placed supine on an operating table, with a reference marker positioned in the area of the greater trochanter. K-wires (3.2 mm), Steinman pins (3 and 4 mm), Apex pins (3 and 4 mm), and a standard screw were used as fixation devices. They were positioned medially in the proximal third of the femur, ventrally in the middle third and laterally in the distal portion. In six different positions of the leg, the spatial positions were recorded with a navigation system. Compared with the standard single screw, with the exception of the 3 mm Apex pins, the two-pin systems were associated with less movement of the marker and could be inserted less invasively. With the knee flexed to 90° and the dislocated hip rotated externally until the lower leg was parallel to the table (figure-four position), all the anchoring devices showed substantial deflection of 1.5° to 2.5°. The most secure area for anchoring markers was the lateral aspect of the femur


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. . We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. . After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (. sd. 0.108): in the annealed group it was 0.1382 mm/year (. sd. 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component. Cite this article: Bone Joint J 2015;97-B:1458–62


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 56 - 62
1 Jan 1988
Johnsson R Thorngren K Persson B

During the 11-year-period from 1970 to 1980, 799 total hip arthroplasties with metal-on-plastic prostheses were performed for primary osteoarthritis. In all cases high viscosity cement was used, but not under pressure; acetabular cartilage was removed, but the femoral canal was not plugged. The rate of revision and risk factors were evaluated by survivorship analysis. The overall cumulative revision rates were 11%, 14% and 19% after 8, 10, and 14 years respectively. When prophylactic antibiotics were not used, there was a significant risk of revision for infection. The risk of revision for mechanical loosening of both the acetabular and femoral components was significantly increased for men, younger patients, and if a snap-fit prosthesis with a 35 mm head and short wedged stem was used. The survivorship findings were validated by multivariate statistical analysis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1201 - 1209
1 Sep 2011
Peng K Hsu W Shih H Hsieh C Huang T Hsu RW Chang P

In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requiring revision for polyethylene wear) and C (n = 15, requiring revision due to aseptic loosening) to verify the involvement of the identified targets in aseptic loosening. When compared with Groups A and B, Group C patients exhibited significant up-regulation of transthyretin and superoxide dismutase 3, but down-regulation of glutathione peroxidase 2 in their hip synovial fluids. Also, higher levels of superoxide dismutase 2 and peroxiredoxin 2, but not superoxide dismutase 1, catalase and glutathione perioxidase 1, were consistently detected in the hip capsules of Group C patients. We propose that dysregulated reactive oxygen species-related enzymes may play an important role in the pathogenesis and progression of aseptic loosening after THR


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 93 - 98
1 Jan 1997
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We have assessed the relative value of various outcome measures after THR, by the analysis of follow-up data from over 2000 patients. They had been reviewed clinically and radiologically six months after operation, at one year, and then every two years, some for 16 years. At each review their pain level, stiffness and opinion of progress were scored and a radiograph taken. We found that pain level was the most informative outcome as a predictor of revision and correlated well with the patients’ opinions. We made a comparison between the six types of implant in the series, using survival analysis and log-rank testing with different pain levels as endpoints. This analysis revealed differences which were not detected by survival analysis using the traditional endpoint of revision. We therefore recommend the use of different levels of pain as the main outcome measures after total hip replacement


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 915 - 922
1 Jul 2018
Joice M Vasileiadis GI Amanatullah DF

Aims

The aim of this study was to assess the efficacy of non-selective and selective non-steroidal anti-inflammatory drugs (NSAIDs) in preventing heterotopic ossification (HO) after total hip arthroplasty (THA).

Methods

A thorough and systematic literature search was conducted and 29 studies were found that met inclusion criteria. Data were extracted and statistical analysis was carried out generating forest plots.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 382 - 390
1 May 1998
Eggli S Pisan M Müller ME

To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (± SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 ± 1.1 mm vertically and 4.4 ± 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 ± 2° and anteversion by 9 ± 3° from the preoperative plans. The mean postoperative leg-length difference was 0.3 ± 0.1 cm clinically and 0.2 ± 0.1 cm radiologically. More than 80% of intraoperative difficulties were anticipated. Preoperative planning is of significant value for the successful performance of THR


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 590 - 595
1 Jul 1997
Espehaug B Engesaeter LB Vollset SE Havelin LI Langeland N

We have assessed the effect of different regimes of antibiotic prophylaxis on the survival of total hip implants, comparing antibiotics administered both systemically and in the bone cement, systemically only, in the bone cement only and with no antibiotics given. We studied 10 905 primary cemented total hip replacements, performed for osteoarthritis of the hip and reported to the Norwegian arthroplasty register between 1987 and 1995. Cox-estimated failure-rate ratios (FRR) are presented with adjustment for gender, age, the brand of cement, the prosthesis, the type of operating theatre and the operating time. For revisions performed for infection (39 operations), the lowest rate of revision was found among patients receiving antibiotic-containing cement plus systemic antibiotics (n = 5804). The revision rate for the 4586 patients receiving systemic antibiotics only was 4.3 times greater (95% CI 1.7 to 11.0, p = 0.001); in 239 with antibiotics in the bone cement only it was 6.3 times greater (CI 1.6 to 25.0, p = 0.003); and in the 276 who did not receive antibiotics it was by 11.5 times greater (CI 2.1 to 63.0, p = 0.002). Adjustment for the total amount of systemic antibiotic administered did not change the results. We also observed an increased revision rate for aseptic loosening (109 operations) comparing the systemic-only (FRR = 1.8, CI 1.1 to 2.9, p = 0.01) and the cement-only regimes (FRR = 2.6, CI 1.2 to 5.9, p = 0.02) with the combined dosage. Our findings show that systemic antibiotics combined with antibiotic-containing bone cement led to fewer revisions than the other methods


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 629 - 631
1 Nov 1984
Swann M

A case is reported of a patient who presented with a soft-tissue tumour at the site of a total hip replacement. This tumour proved to be a malignant fibrous histiocytoma


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 342 - 353
1 Aug 1981
Buchholz H Elson R Engelbrecht E Lodenkamper H Rottger J Siegel A

Exchange operation is recommended as the treatment of choice for most deep infections involving a total hip replacement. This revision arthroplasty comprises, in one stage, excision of soft tissue, removal of implant and cement, replacement with an appropriate implant using Palacos R acrylic cement loaded with an appropriate antibiotic and, more recently, systemic antibiotics. During our first 10 years without systemic antibiotics we have achieved an overall 77 per cent success rate from a first attempt in 583 patients and a 90 per cent success rate after subsequent exchange procedures. Morbidity is significant but acceptable. Success is defined as control of infection, no loosening, and useful function. The factors associated with failures include, in particular, specific infections (Pseudomonas group, Streptococcus group D, Proteus group, and Escherichia coli), delay in operation and inadequate antibiotic dosage in the cement


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 839 - 845
1 Jun 2007
Barsoum WK Patterson RW Higuera C Klika AK Krebs VE Molloy R

Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement. We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 467 - 474
1 May 1997
Hukkanen M Corbett SA Batten J Konttinen YT McCarthy ID Maclouf J Santavirta S Hughes SPF Polak JM

Aseptic loosening is a major cause of failure of total hip arthroplasty. The adverse tissue response to prosthetic wear particles, with activation of cytokine and prostanoid production, contributes to bone loss around the implants. We have investigated the possibility that inducible nitric oxide synthase (iNOS) and cyclo-oxygenase-2 (COX-2) are expressed in macrophages in the pseudomembrane at the bone-implant interface, thereby contributing to the periprosthetic bone resorption. We also assessed whether peroxynitrite, a nitric oxide (NO)-derived oxidant associated with cellular injury, is generated in the membrane. Enzymatic activity of iNOS was measured using the arginine-citrulline assay technique and prostaglandin E. 2. (PGE. 2. ), as an indicator of COX-2 activity, was measured using an enzyme immunoassay. Cellular immunoreactivity for iNOS, nitrotyrosine (a marker of peroxynitrite-induced cellular injury) and COX-2 was assessed by quantitative peroxidase immunocytochemistry while immunofluorescence methods were used for subsequent co-localisation studies with CD68. +. macrophages. The presence of calcium-independent iNOS activity and PGE. 2. production was confirmed in the homogenized interface membrane. Immunocytochemistry showed that periprosthetic CD68. +. wear-debris-laden macrophages were the most prominent cell type immunoreactive for iNOS, nitrotyrosine and COX-2. Other periprosthetic inflammatory and resident cell types were also found to immunolocalise nitrotyrosine thereby suggesting peroxynitrite-induced protein nitrosylation and cellular damage not only in NO-producing CD68. +. macrophages, but also in their neighbouring cells. These data indicate that both iNOS and COX-2 are expressed by CD68. +. macrophages in the interface membrane and peroxynitrite-induced cellular damage is evident in such tissue. If high-output NO and peroxynitrite generation were to cause macrophage cell death, this would result in the release of phagocytosed wear debris into the extracellular matrix. A detrimental cycle of events would then be established with further phagocytosis by newly-recruited inflammatory cells and subsequent NO, peroxynitrite and prostanoid synthesis. Since both NO and have been implicated in the induction and PGE. 2. maintenance of chronic inflammation with resulting loss of bone, and peroxynitrite in the pathogenesis of disease states, they may be central to the pathogenesis of aseptic loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 534 - 547
1 Jul 1995
Geesink R Hoefnagels N

We present the 5.6- to 7.6-year results of our first 118 hydroxyapatite (HA)-coated total hip replacements in patients under 66 years of age. The titanium femoral component has proximal HA coating and was usually articulated with an HA-coated threaded cup. The HA coating of 50 microns thickness has a porosity of below 3%, 97% HA purity and 65% crystallinity. The survival rate at a mean of six years was 100% for the HA-coated stems and 99% for the HA-threaded cups. The average Harris hip score at one year was 96, and at three years and thereafter 98. There was a very low incidence of early pain after surgery. Serial radiographs showed rapid bony integration of implants with evidence of bone apposition on the coating within six months. By Engh's criteria, all the femoral components had confirmed bone ongrowth after three years. We found no deterioration of results with time, and consider that our clinical and radiological results show that HA coatings can provide early pain relief and durable implant fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 22 - 24
1 Feb 1980
Bras J Veraart B

Numerous intravascular bony spicules were found at necropsy in both lungs of an 84-year-old patient who had undergone total hip replacements three and 10 months before death. It is suggested that acetabular grindings enter the damaged venous system at operation and are filtered out by the lungs


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 607 - 610
1 Aug 1988
Willett K Simmons C Bentley G

A prospective study of 120 consecutive total hip replacements showed that deep suction drains produced maximal drainage volumes in the first 24 hours. Their continued presence resulted in minimal further drainage, did not reduce the likelihood of haematoma formation and led in some cases to the spread of skin organisms into the wound


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 222 - 224
1 Mar 1985
Harley J Boston D

Fracture of the polyethylene acetabular cup is a rare late complication of total hip replacement. Five cases are reported. In each one this followed a fall, and involved a Muller arthroplasty which had previously been symptomless. It is postulated that ridges or other irregularities of bone, produced by keying holes, could lead to areas of thin cement and potential weakness of support for the cup