This systematic review places a recently completed multicentre randomized controlled trial (RCT), UK FROST, in the context of existing randomized evidence for the management of primary frozen shoulder. UK FROST compared the effectiveness of pre-specified physiotherapy techniques with a steroid injection (PTSI), manipulation under anaesthesia (MUA) with a steroid injection, and arthroscopic capsular release (ACR). This review updates a 2012 review focusing on the effectiveness of MUA, ACR, hydrodilatation, and PTSI. MEDLINE, Embase, PEDro, Science Citation Index, Clinicaltrials.gov, CENTRAL, and the World Health Organization (WHO) International Clinical Trials Registry were searched up to December 2018. Reference lists of included studies were screened. No language restrictions applied. Eligible studies were RCTs comparing the effectiveness of MUA, ACR, PTSI, and hydrodilatation against each other, or supportive care or no treatment, for the management of primary frozen shoulder.Aims
Methods
The response to the COVID-19 pandemic has raised the profile and level of interest in the use, acceptability, safety, and effectiveness of virtual outpatient consultations and telemedicine. These models of care are not new but a number of challenges have so far hindered widespread take-up and endorsement of these ways of working. With the response to the COVID-19 pandemic, remote and virtual working and consultation have become the default. This paper explores our experience of and learning from virtual and remote consultation and questions how this experience can be retained and developed for the future. Cite this article:
Patient-specific cutting guides (PSCGs) are designed
to improve the accuracy of alignment of total knee replacement (TKR).
We compared the accuracy of limb alignment and component positioning
after TKR performed using PSCGs or conventional instrumentation.
A total of 80 patients were randomised to undergo TKR with either of
the different forms of instrumentation, and radiological outcomes
and peri-operative factors such as operating time were assessed.
No significant difference was observed between the groups in terms
of tibiofemoral angle or femoral component alignment. Although the
tibial component in the PSCGs group was measurably closer to neutral
alignment than in the conventional group, the size of the difference
was very small (89.8° (. sd. 1.2) vs 90.5°
(. sd. 1.6); p = 0.030). This new
This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.Aims
Methods
Upper limb amputations, ranging from transhumeral to partial hand, can be devastating for patients, their families, and society. Modern paradigm shifts have focused on reconstructive options after upper extremity limb loss, rather than considering the amputation an ablative procedure. Surgical advancements such as targeted muscle reinnervation and regenerative peripheral nerve interface, in combination with technological development of modern prosthetics, have expanded options for patients after amputation. In the near future, advances such as osseointegration, implantable myoelectric sensors, and implantable nerve cuffs may become more widely used and may expand the options for prosthetic integration, myoelectric signal detection, and restoration of sensation. This review summarizes the current advancements in surgical techniques and prosthetics for upper limb amputees. Cite this article:
The purpose is to determine the non-inferiority of a smartphone-based exercise educational care management system after primary knee arthroplasty compared with a traditional in-person physiotherapy rehabilitation model. A multicentre prospective randomized controlled trial was conducted evaluating the use of a smartphone-based care management system for primary total knee arthroplasty (TKA) and partial knee arthroplasty (PKA). Patients in the control group (n = 244) received the respective institution’s standard of care with formal physiotherapy. The treatment group (n = 208) were provided a smartwatch and smartphone application. Early outcomes assessed included 90-day knee range of movement, EuroQoL five-dimension five-level score, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) score, 30-day single leg stance (SLS) time, Time up and Go (TUG) time, and need for manipulation under anaesthesia (MUA).Aims
Methods
Rheumatoid arthritis (RA), which mainly results from fibroblast-like synoviocyte (FLS) dysfunction, is related to oxidative stress. Advanced oxidation protein products (AOPPs), which are proinflammatory mediators and a novel biomarker of oxidative stress, have been observed to accumulate significantly in the serum of RA patients. Here, we present the first investigation of the effects of AOPPs on RA-FLSs and the signalling pathway involved in AOPP-induced inflammatory responses and invasive behaviour. We used different concentrations of AOPPs (50 to 200 µg/ml) to treat RA-FLSs. Cell migration and invasion and the expression levels of tumour necrosis factor-alpha (TNF-α), interleukin-6 (IL-6), matrix metalloproteinase-3 (MMP-3), and MMP-13 were investigated. Western blot and immunofluorescence were used to analyze nuclear factor-κB (NF-κB) activation.Aims
Methods
Aims. The aim of this study was to compare the Push Ortho Thumb Brace
CMC and a custom-made orthosis in the treatment of patients with
primary osteoarthritis of the carpometacarpal joint of the thumb.
Our outcome measures were pain scores, tests of hand function, patient
satisfaction and patient preference. Patients and Methods. A multicentre crossover randomised controlled trial was conducted
which included 63 patients (44 women) with primary osteoarthritis
of the carpometacarpal joint of the thumb. Of these, 59 patients
with a mean age of 60.1 years (standard deviation 8.2), completed
the study. Patients used both orthoses for two weeks with a two-week washout
period in-between. Pain was measured on a 10-cm visual analogue
scale. Hand function was assessed using the Jebsen Taylor Hand Function
test, Nine Hole Peg Test, key grip, pinch grip and Functional Index
for Hand Osteoarthritis. Patient preference was assessed using the
Dutch version of the Quebec User Evaluation of Satisfaction with
Assistive
Arthroplasty has become increasingly popular to treat end-stage ankle arthritis. Iatrogenic posterior neurovascular and tendinous injury have been described from saw cuts. However, it is hypothesized that posterior ankle structures could be damaged by inserting tibial guide pins too deeply and be a potential cause of residual hindfoot pain. The preparation steps for ankle arthroplasty were performed using the Infinity total ankle system in five right-sided cadaveric ankles. All tibial guide pins were intentionally inserted past the posterior tibial cortex for assessment. All posterior ankles were subsequently dissected, with the primary endpoint being the presence of direct contact between the structure and pin.Aims
Methods
Aims. Our aim was to report survivorship data and lessons learned with
the Corail/Pinnacle cementless total hip arthroplasty (THA) system. Patients and Methods. Between August 2005 and March 2015, a total of 4802 primary cementless
Corail/Pinnacle THAs were performed in 4309 patients. In March 2016,
we reviewed these hips from a prospectively maintained database. Results . A total of 80 hips (1.67%) have been revised which is equivalent
to a cumulative risk of revision of 2.5% at ten years. The rate
of revision was not significantly higher in patients aged ≥ 70 years
(p = 0.93). The leading indications for revision were instability
(n = 22, 0.46%), infection (n = 20, 0.42%), aseptic femoral loosening
(n = 15, 0.31%) and femoral fracture (n = 6, 0.12%). There were
changes in the surgical technique with respect to the Corail femoral component
during the ten-year period involving a change to collared components
and a trend towards larger size. These resulted in a decrease in
the rate of iatrogenic femoral fracture and a decrease in the rate
of aseptic loosening. Conclusion. The rate of revision in this series is comparable with the best
performing THAs in registry data. Most revisions were not directly
related to the implants. Despite extensive previous experience with
cemented femoral components, the senior author noted a learning
curve requiring increased focus on primary stability. The number
of revisions related to the femoral component is reducing. Any new
A pragmatic multicentre randomized controlled trial, UK FROzen Shoulder Trial (UK FROST), was conducted in the UK NHS comparing the cost-effectiveness of commonly used treatments for adults with primary frozen shoulder in secondary care. A cost utility analysis from the NHS perspective was performed. Differences between manipulation under anaesthesia (MUA), arthroscopic capsular release (ACR), and early structured physiotherapy plus steroid injection (ESP) in costs (2018 GBP price base) and quality adjusted life years (QALYs) at one year were used to estimate the cost-effectiveness of the treatments using regression methods.Aims
Methods
Poly (ADP-ribose) polymerase (PARP) inhibitor has been reported to attenuate inflammatory response in rat models of inflammation. This study was designed to investigate the effect of PARP signalling in osteoarthritis (OA) cartilage inflammatory response in an OA rat model. The OA model was established by anterior cruciate ligament transection with medial meniscectomy in Wistar rats. The poly (ADP-ribose) polymerase 1 (PARP-1) shRNA (short hairpin (sh)-PARP-1) and negative control shRNA (sh-NC) were delivered using a lentiviral vector and were intra-articularly injected into rats after surgery. The weight-bearing distribution of the hind limbs and the knee joint width were measured every two weeks. The expression levels of PARP-1, inducible nitric oxide synthase (iNOS), and cyclooxygenase-2 (COX-2) in cartilage were determined using real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) and Western blot. The serum concentrations of inflammatory cytokines were detected using enzyme-linked immunosorbent assay (ELISA).Aims
Methods
The ongoing COVID-19 pandemic has disrupted and delayed medical and surgical examinations where attendance is required in person. Our article aims to outline the validity of online assessment, the range of benefits to both candidate and assessor, and the challenges to its implementation. In addition, we propose pragmatic suggestions for its introduction into medical assessment. We reviewed the literature concerning the present status of online medical and surgical assessment to establish the perceived benefits, limitations, and potential problems with this method of assessment.Aims
Methods
The recent development of locking-plate
Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis.Aims
Methods