header advert
Results 361 - 380 of 461
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1377 - 1381
1 Oct 2011
Thomas WJC Jenkins EF Owen JM Sangster MJ Kirubanandan R Beynon C Woods DA

The effect of timing of a manipulation under anaesthetic (MUA) and injection of corticosteroid and local anaesthetic for the treatment of frozen shoulder has attracted little attention to date. All studies describe a period of conservative treatment before proceeding to an MUA. Delay has been associated with a poorer outcome.

We present a retrospective review of a prospectively collected, single-surgeon, consecutive series of 246 patients with a primary frozen shoulder treated by MUA within four weeks of presentation. The mean duration of presenting symptoms was 28 weeks (6 to 156), and time to initial post-operative assessment was 26 days (5 to 126). The Oxford shoulder score (OSS) improved by a mean of 16 points (Wilcoxon signed-ranks test, p < 0.001) with a mean OSS at this time of 43 (7 to 48). Linear regression analysis showed no correlation between the duration of presenting symptoms and OSS at initial follow-up (R2 < 0.001) or peri-operative change in OSS (R2 < 0.001) or OSS at long-term follow-up (R2 < 0.03). Further analysis at a mean of 42 months (8 to 127) revealed a sustained improvement with a mean OSS of 44 (16 to 48).

A good outcome follows an MUA and injection of corticosteroid and local anaesthetic in patients with primary frozen shoulder, independent of the duration of the presenting symptoms, and this improvement is maintained in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 919 - 927
1 Jul 2012
Baker PN Petheram T Jameson SS Avery PJ Reed MR Gregg PJ Deehan DJ

Following arthroplasty of the knee, the patient’s perception of improvement in symptoms is fundamental to the assessment of outcome. Better clinical outcome may offset the inferior survival observed for some types of implant. By examining linked National Joint Registry (NJR) and patient-reported outcome measures (PROMs) data, we aimed to compare PROMs collected at a minimum of six months post-operatively for total (TKR: n = 23 393) and unicondylar knee replacements (UKR: n = 505). Improvements in knee-specific (Oxford knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared and adjusted for case-mix differences using multiple regression. Whereas the improvements in the OKS and EQ-5D were significantly greater for TKR than for UKR, once adjustments were made for case-mix differences and pre-operative score, the improvements in the two scores were not significantly different. The adjusted mean differences in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI) -0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37), respectively.

We found no difference in the improvement of either knee-specific or general health outcomes between TKR and UKR in a large cohort of registry patients. With concerns about significantly higher revision rates for UKR observed in worldwide registries, we question the widespread use of an arthroplasty that does not confer a significant benefit in clinical outcome.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 17 - 20
1 Feb 2014

The February 2014 Knee Roundup360 looks at: whether sham surgery is as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether trans-tibial tunnel placement increases the risk of graft failure in ACL surgery; whether joint replacements prevent cardiac events; the size of the pulmonary embolism problem; tranexamic acid and knee replacement haemostasis; matching the demand for knee replacement and follow-up; predicting the length of stay after knee replacement; and popliteal artery injury in TKR.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 868 - 875
1 Jul 2014
Lübbeke A Gonzalez A Garavaglia G Roussos C Bonvin A Stern R Peter R Hoffmeyer P

Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively.

A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen.

In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern.

Cite this article: Bone Joint J 2014; 96-B:868–75.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 69 - 75
1 Mar 2014
Parsons N Griffin XL Achten J Costa ML

Objectives

To study the measurement properties of a joint specific patient reported outcome measure, a measure of capability and a general health-related quality of life (HRQOL) tool in a large cohort of patients with a hip fracture.

Methods

Responsiveness and associations between the Oxford Hip Score (a hip specific measure: OHS), ICEpop CAPability (a measure of capability in older people: ICECAP-O) and EuroQol EQ-5D (general health-related quality of life measure: EQ-5D) were assessed using data available from two large prospective studies. The three outcome measures were assessed concurrently at a number of fixed follow-up time-points in a consecutive sequence of patients, allowing direct assessment of change from baseline, inter-measure associations and validity using a range of statistical methods.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 461 - 467
1 Mar 2010
Wik TS Østbyhaug PO Klaksvik J Aamodt A

The cortical strains on the femoral neck and proximal femur were measured before and after implantation of a resurfacing femoral component in 13 femurs from human cadavers. These were loaded into a hip simulator for single-leg stance and stair-climbing. After resurfacing, the mean tensile strain increased by 15% (95% confidence interval (CI) 6 to 24, p = 0.003) on the lateral femoral neck and the mean compressive strain increased by 11% (95% CI 5 to 17, p = 0.002) on the medial femoral neck during stimulation of single-leg stance. On the proximal femur the deformation pattern remained similar to that of the unoperated femurs.

The small increase of strains in the neck area alone would probably not be sufficient to cause fracture of the neck However, with patient-related and surgical factors these strain changes may contribute to the risk of early periprosthetic fracture.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 210 - 213
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for independent patients with displaced intracapsular fractures of the proximal femur. The recognised alternatives are hemiarthroplasty and total hip replacement. At present there is no established standard of care, with both types of arthroplasty being used in many centres. The principal advantages of total hip replacement are a functional benefit over hemiarthroplasty and a reduced risk of revision surgery. The principal criticism is the increased risk of dislocation. We believe that an alternative acetabular component may reduce the risk of dislocation but still provide the functional benefit of total hip replacement in these patients. We therefore propose to investigate the dislocation risk of a dual-mobility acetabular component compared with standard polyethylene component in total hip replacement for independent patients with displaced intracapsular fractures of the proximal femur within the framework of the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:210–13.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1416 - 1423
1 Oct 2011
Nguyen AR Ling J Gomes B Antoniou G Sutherland LM Cundy PJ

We analysed the incidence of slipped capital femoral epiphysis (SCFE) in South Australia, investigating possible associations between an increased incidence of SCFE, the local indigenous population and the Australian obesity epidemic during the last 20 years. Data including race, age and gender were collected to obtain a profile of the South Australian SCFE patient, and were then compared with epidemiological data for South Australian adolescents. We concluded that the incidence of both obesity and SCFE is increasing. We also noted that the median weight of SCFE patients has increased and the mean age at diagnosis has decreased. Despite weight profiles comparable with those of the general population, we noted that an indigenous child was three times more likely to develop SCFE than a non-indigenous child. As far as we know there is no published literature on the predisposition of Aboriginal Australians to SCFE.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1694 - 1699
1 Dec 2005
Floerkemeier T Hurschler C Witte F Wellmann M Thorey F Vogt U Windhagen H

The ability to predict load-bearing capacity during the consolidation phase in distraction osteogenesis by non-invasive means would represent a significant advance in the management of patients undergoing such treatment. Measurements of stiffness have been suggested as a promising tool for this purpose. Although the multidimensional characteristics of bone loading in compression, bending and torsion are apparent, most previous experiments have analysed only the relationship between maximum load-bearing capacity and a single type of stiffness. We have studied how compressive, bending and torsional stiffness are related to the torsional load-bearing capacity of healing callus using a common set of samples of bone regenerate from 26 sheep treated by tibial distraction osteogenesis.

Our findings showed that measurements of torsional, bending and compressive stiffness were all suitable as predictors of the load-bearing capacity of healing callus. Measurements of torsional stiffness performed slightly better than those of compressive and bending stiffness.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 367 - 373
1 Mar 2010
Kendrick BJL Longino D Pandit H Svard U Gill HS Dodd CAF Murray DW Price AJ

The Oxford Unicompartmental Knee replacement (UKR) was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study involving this implant, which reported very low rates of wear in some specimens but abnormal patterns of wear in others. There has been no further investigation of these abnormal patterns. The bearings were retrieved from 47 patients who had received a medial Oxford UKR for anteromedial osteoarthritis of the knee. None had been studied previously. The mean time to revision was 8.4 years (sd 4.1), with 20 having been implanted for over ten years. The macroscopic pattern of polyethylene wear and the linear penetration were recorded for each bearing. The mean rate of linear penetration was 0.07 mm/year. The patterns of wear fell into three categories, each with a different rate of linear penetration; 1) no abnormal macroscopic wear and a normal articular surface, n = 16 (linear penetration rate = 0.01 mm/year); 2) abnormal macroscopic wear and normal articular surfaces with extra-articular impingement, n = 16 (linear penetration rate = 0.05 mm/year); 3) abnormal macroscopic wear and abnormal articular surfaces with intra-articular impingement +/− signs of non-congruous articulation, n = 15 (linear penetration rate = 0.12 mm/year). The differences in linear penetration rate were statistically significant (p < 0.001).

These results show that very low rates of polyethylene wear are possible if the device functions normally. However, if the bearing displays suboptimal function (extra-articular, intra-articular impingement or incongruous articulation) the rates of wear increase significantly.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1354 - 1359
1 Oct 2009
Giannoudis PV Nikolaou VS Kheir E Mehta S Stengel D Roberts CS

We investigated whether patients who underwent internal fixation for an isolated acetabular fracture were able to return to their previous sporting activities.

We studied 52 consecutive patients with an isolated acetabular fracture who were operated on between January 2001 and December 2002. Their demographic details, fracture type, rehabilitation regime, outcome and complications were documented prospectively as was their level and frequency of participation in sport both before and after surgery. Quality of life was measured using the EuroQol-5D health outcome tool (EQ-5D).

There was a significant reduction in level of activity, frequency of participation in sport (both p < 0.001) and EQ-5D scores in patients of all age groups compared to a normal English population (p = 0.001). A total of 22 (42%) were able to return to their previous level of activities: 35 (67%) were able to take part in sport at some level. Of all the parameters analysed, the Matta radiological follow-up criteria were the single best predictor for resumption of sporting activity and frequency of participation.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1290 - 1294
1 Sep 2013
Lim KBL Lim CT Tawng DK

Supracondylar humeral fractures are common in children, but there are no classification systems or radiological parameters that predict the likelihood of having to perform an open reduction. In a retrospective case–control study we evaluated the use of the medial spike angle and fracture tip–skin distance to predict the mode of reduction (closed or open) and the operating time in fractures with posterolateral displacement. A total of 21 patients (4.35%) with a small medial spike angle (< 45°) were identified from a total of 494 patients, and 42 patients with a medial spike angle of > 45° were randomly selected as controls. The medial spike group had significantly smaller fracture tip–skin distances (p < 0.001), longer operating times (p = 0.004) and more complications (p = 0.033) than the control group. There was no significant difference in the mode of reduction and a composite outcome measure. After adjustments for age and gender, only fracture tip–skin distance remained significantly associated with the operating time (β = -0.724, p = 0.042) and composite outcome (OR 0.863 (95% confidence interval 0.746 to 0.998); p = 0.048).

Paediatric orthopaedic surgeons should have a lower threshold for open reduction when treating patients with a small medial spike angle and a small fracture tip–skin distance.

Cite this article: Bone Joint J 2013;95-B:1290–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1115 - 1121
1 Aug 2007
Messick KJ Miller MA Damron LA Race A Clarke MT Mann KA

The role of vacuum mixing on the reduction of porosity and on the clinical performance of cemented total hip replacements remains uncertain. We have used paired femoral constructs prepared with either hand-mixed or vacuum-mixed cement in a cadaver model which simulated intra-operative conditions during cementing of the femoral component. After the cement had cured, the distribution of its porosity was determined, as was the strength of the cement-stem and cement-bone interfaces.

The overall fraction of the pore area was similar for both hand-mixed and vacuum-mixed cement (hand 6%; vacuum 5.7%; paired t-test, p = 0.187). The linear pore fractions at the interfaces were also similar for the two techniques. The pore number-density was much higher for the hand-mixed cement (paired t-test, p = 0.0013). The strength of the cement-stem interface was greater with the hand-mixed cement (paired t-test, p = 0.0005), while the strength of the cement-bone interface was not affected by the conditions of mixing (paired t-test, p = 0.275). The reduction in porosity with vacuum mixing did not affect the porosity of the mantle, but the distribution of the porosity can be affected by the technique of mixing used.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 962 - 970
1 Jul 2007
Albert C Patil S Frei H Masri B Duncan C Oxland T Fernlund G

This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting.

Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured.

Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and valgus/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum.

The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 738 - 745
1 Jun 2011
Davda K Lali FV Sampson B Skinner JA Hart AJ

We retrospectively analysed concentrations of chromium and cobalt ions in samples of synovial fluid and whole blood taken from a group of 92 patients with failed current-generation metal-on-metal hip replacements. We applied acid oxidative digestion to our trace metal analysis protocol, which found significantly higher levels of metal ion concentrations in blood and synovial fluid than a non-digestive method. Patients were subcategorised by mode of failure as either ‘unexplained pain’ or ‘defined causes’. Using this classification, chromium and cobalt ion levels were present over a wider range in synovial fluid and not as strongly correlated with blood ion levels as previously reported. There was no significant difference between metal ion concentrations and manufacturer of the implant, nor femoral head size below or above 50 mm. There was a moderately positive correlation between metal ion levels and acetabular component inclination angle as measured on three-dimensional CT imaging.

Our results suggest that acid digestion of samples of synovial fluid samples is necessary to determine metal ion concentrations accurately so that meaningful comparisons can be made between studies.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1069 - 1076
1 Aug 2007
Goris RJA Leixnering M Huber W Figl M Jaindl M Redl H

We studied prospectively the regional inflammatory response to a unilateral distal radial fracture in 114 patients at eight to nine weeks after injury and again at one year. Our aim was to identify patients at risk for a delayed recovery and particularly those likely to develop complex regional pain syndrome. In order to quantify clinically the inflammatory response, a regional inflammatory score was developed. In addition, blood samples were collected from the antecubital veins of both arms for comparative biochemical and blood-gas analysis.

The severity of the inflammatory response was related to the type of treatment (Kruskal-Wallis test, p = 0.002). A highly significantly-positive correlation was found between the regional inflammatory score and the length of time to full recovery (r2 = 0.92, p = 0.01, linear regession). A regional inflammatory score of 5 points with a sensitivity of 100% but a specificity of only 16% also identified patients at risk of complex regional pain syndrome. None of the biochemical parameters studied correlated with regional inflammatory score or predicted the development of complex regional pain syndrome.

Our study suggests that patients with a distal radial fracture and a regional inflammatory score of 5 points or more at eight to nine weeks after injury should be considered for specific anti-inflammatory treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1642 - 1647
1 Dec 2010
deSouza RM Parsons NR Oni T Dalton P Costa M Krikler S

We report serum metal ion level data in patients with unilateral and bilateral hip resurfacing over a ten-year period. In these patients there is an increase in both cobalt and chromium levels above the accepted reference ranges during the first 18 months after operation. Metal ion levels remain elevated, but decline slowly for up to five years. However, the levels then appear to start rising again in some patients up to the ten-year mark. There was no significant difference in cobalt or chromium levels between men and women. These findings appear to differ from much of the current literature.

The clinical significance of a raised metal ion level remains under investigation.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 314 - 319
1 Mar 2013
Masjedi M Nightingale CL Azimi DY Cobb JP

We examined the relationship between the size of the femoral cam in femoroacetabular impingement (FAI) and acetabular pathomorphology to establish if pincer impingement exists in patients with a femoral cam.

CT scans of 37 symptomatic impinging hips with a femoral cam were analysed in a three-dimensional study and were compared with 34 normal hips. The inclination and version of the acetabulum as well as the acetabular rim angle and the bony acetabular coverage were calculated. These measurements were correlated with the size and shape of the femoral cams.

While the size of the femoral cam varied characteristically, the acetabular morphology of the two groups was similar in terms of version (normal mean 23° (sd 7°); cam mean 22° (sd 9°)), inclination (normal mean 57° (sd 5°); cam mean 56° (sd 5°)), acetabular coverage (normal mean 41% (sd 5%); cam mean 42% (sd 4%)) and the mean acetabular rim angle (normal mean 82° (sd 5°); cam mean 83° (sd 4°)).

We found no correlation between acetabular morphology and the severity of cam lesion and no evidence of either global or focal over-coverage to support the diagnosis of ‘mixed’ FAI. The femoral cam may provoke edge loading but removal of any acetabular bearing surface when treating cam FAI might induce accelerated wear.

Cite this article: Bone Joint J 2013;95-B:314–19.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1255 - 1262
1 Sep 2013
Clement ND Beauchamp NJF Duckworth AD McQueen MM Court-Brown CM

We describe the outcome of tibial diaphyseal fractures in the elderly (≥ 65 years of age). We prospectively followed 233 fractures in 225 elderly patients over a minimum ten-year period. Demographic and descriptive data were acquired from a prospective trauma database. Mortality status was obtained from the General Register Office database for Scotland. Diaphyseal fractures of the tibia in the elderly occurred predominantly in women (73%) and after a fall (61%). During the study period the incidence of these fractures decreased, nearly halving in number. The 120-day and one-year unadjusted mortality rates were 17% and 27%, respectively, and were significantly greater in patients with an open fracture (p < 0.001). The overall standardised mortality ratio (SMR) was significantly increased (SMR 4.4, p < 0.001) relative to the population at risk, and was greatest for elderly women (SMR 8.1, p < 0.001). These frailer patients had more severe injuries, with an increased rate of open fractures (30%), and suffered a greater rate of nonunion (10%).

Tibial diaphyseal fractures in the elderly are most common in women after a fall, are more likely to be open than in the rest of the population, and are associated with a high incidence of nonunion and mortality.

Cite this article: Bone Joint J 2013;95-B:1255–62.