The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction. Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study.Aims
Patients and Methods
The aim of this study was to report a retrospective, consecutive
series of patients with adolescent idiopathic scoliosis (AIS) who
were treated with posterior minimally invasive surgery (MIS) with
a mean follow-up of two years ( We prospectively collected the data of 70 consecutive patients
with AIS treated with MIS using three incisions and a muscle-splitting
approach by a single surgeon between June 2013 and February 2016
and these were retrospectively reviewed. There were eight male and
62 female patients with a mean age of 15 years (Aims
Patients and Methods
This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group. A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.Objectives
Methods
The aim of this study was to report the long-term outcome and
implant survival of the lateral resurfacing elbow (LRE) arthroplasty
in the treatment of elbow arthritis. We reviewed a consecutive series of 27 patients (30 elbows) who
underwent LRE arthroplasty between December 2005 and January 2008.
There were 15 women and 12 men, with a mean age of 61 years (25
to 82). The diagnosis was primary hypotrophic osteoarthritis (OA)
in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA)
in five (five elbows) and rheumatoid arthritis (RA) in ten patients
(11 elbows). The mean clinical outcome scores including the Mayo
Elbow Performance Score (MEPS), the American Shoulder and Elbow
Surgeons elbow score (ASES-e), the mean range of movement and the
radiological outcome were recorded at three, six and 12 months and
at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample Aim
Patients and Methods
We present the results of correcting a double or triple curve
adolescent idiopathic scoliosis using a convex segmental pedicle
screw technique. We reviewed 191 patients with a mean age at surgery of 15 years
(11 to 23.3). Pedicle screws were placed at the convexity of each
curve. Concave screws were inserted at one or two cephalad levels
and two caudal levels. The mean operating time was 183 minutes (132
to 276) and the mean blood loss 0.22% of the total blood volume
(0.08% to 0.4%). Multimodal monitoring remained stable throughout
the operation. The mean hospital stay was 6.8 days (5 to 15).Aims
Patients and Methods
Lumbar fusion is known to reduce the variation in pelvic tilt
between standing and sitting. A flexible lumbo-pelvic unit increases
the stability of total hip arthroplasty (THA) when seated by increasing
anterior clearance and acetabular anteversion, thereby preventing
impingement of the prosthesis. Lumbar fusion may eliminate this protective
pelvic movement. The effect of lumbar fusion on the stability of
total hip arthroplasty has not previously been investigated. The Medicare database was searched for patients who had undergone
THA and spinal fusion between 2005 and 2012. PearlDiver software
was used to query the database by the International Classification
of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) procedural
code for primary THA and lumbar spinal fusion. Patients who had
undergone both lumbar fusion and THA were then divided into three
groups: 1 to 2 levels, 3 to 7 levels and 8+ levels of fusion. The
rate of dislocation in each group was established using ICD-9-CM codes.
Patients who underwent THA without spinal fusion were used as a
control group. Statistical significant difference between groups
was tested using the chi-squared test, and significance set at p
<
0.05.Aims
Patients and Methods
Accurate placement of the acetabular component is essential in
total hip arthroplasty (THA). The purpose of this study was to determine
if the ability to achieve inclination of the acetabular component
within the ‘safe-zone’ of 30° to 50° could be improved with the
use of an inclinometer. We reviewed 167 primary THAs performed by a single surgeon over
a period of 14 months. Procedures were performed at two institutions:
an inpatient hospital, where an inclinometer was used (inclinometer
group); and an ambulatory centre, where an inclinometer was not
used as it could not be adequately sterilized (control group). We excluded
47 patients with a body mass index (BMI) of > 40 kg/m2,
age of > 68 years, or a surgical indication other than osteoarthritis
whose treatment could not be undertaken in the ambulatory centre.
There were thus 120 patients in the study, 68 in the inclinometer
group and 52 in the control group. The inclination angles of the acetabular
component were measured from de-identified plain radiographs by
two blinded investigators who were not involved in the surgery.
The effect of the use of the inclinometer on the inclination angle
was determined using multivariate regression analysis.Aims
Patients and Methods
The aim of the study was to compare measures of the quality of
life (QOL) after resection of a chordoma of the mobile spine with
the national averages in the United States and to assess which factors
influenced the QOL, symptoms of anxiety and depression, and coping
with pain post-operatively in these patients. A total of 48 consecutive patients who underwent resection of
a primary or recurrent chordoma of the mobile spine between 2000
and 2015 were included. A total of 34 patients completed a survey
at least 12 months post-operatively. The primary outcome was the
EuroQol-5 Dimensions (EQ-5D-3L) questionnaire. Secondary outcomes were
the Patient-Reported Outcome Measurement Information System (PROMIS)
anxiety, depression and pain interference questionnaires. Data which
were recorded included the indication for surgery, the region of
the tumour, the number of levels resected, the status of the surgical
margins, re-operations, complications, neurological deficit, length
of stay in hospital and rate of re-admission.Aims
Patients and Methods
The sacrum is frequently invaded by a pelvic tumour. The aim
of this study was to review our experience of treating this group
of patients and to identify the feasibility of a new surgical classification
in the management of these tumours. We reviewed 141 patients who, between 2005 and 2014, had undergone
surgical excision of a pelvic tumour with invasion of the sacrum. In a new classification, pelvisacral (Ps) I, II, and III resections
refer to a sagittal osteotomy through the ipsilateral wing of the
sacrum, through the sacral midline, or lateral to the contralateral
sacral foramina, respectively. A Ps a resection describes a pelvic
osteotomy through the ilium and a Ps b resection describes a concurrent
resection of the acetabulum with osteotomies performed through the
pubis and ischium or the pubic symphysis. Within each type, surgical
approaches were standardized to guide resection of the tumour.Aims
Patients and Methods
Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.Objectives
Methods
Outcome measures quantifying aspects of health in a precise,
efficient, and user-friendly manner are in demand. Computer adaptive
tests (CATs) may overcome the limitations of established fixed scales
and be more adept at measuring outcomes in trauma. The primary objective
of this review was to gain a comprehensive understanding of the
psychometric properties of CATs compared with fixed-length scales
in the assessment of outcome in patients who have suffered trauma
of the upper limb. Study designs, outcome measures and methodological
quality are defined, along with trends in investigation. A search of multiple electronic databases was undertaken on 1
January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”,
and “anatomical regions”. Studies involving adults suffering trauma
to the upper limb, and undergoing any intervention, were eligible.
Those involving the measurement of outcome with any CATs were included.
Identification, screening, and eligibility were undertaken, followed
by the extraction of data and quality assessment using the Consensus-Based
Standards for the Selection of Health Measurement Instruments (COSMIN) criteria.
The review is reported according to the Preferred Reporting Items
for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg istered (PROSPERO: CRD42016053886).Aims
Materials and Methods
We undertook a prospective non-randomised radiological study
to evaluate the preliminary results of using magnetically-controlled
growing rods (MAGEC System, Ellipse technology) to treat children
with early-onset scoliosis. Between January 2011 and January 2015, 19 children were treated
with magnetically-controlled growing rods (MCGRs) and underwent
distraction at three-monthly intervals. The mean age of our cohort
was 9.1 years (4 to 14) and the mean follow-up 22.4 months (5.1
to 35.2). Of the 19 children, eight underwent conversion from traditional growing
rods. Whole spine radiographs were carried out pre- and post-operatively:
image intensification was used during each lengthening in the outpatient
department. The measurements evaluated were Cobb angle, thoracic kyphosis,
proximal junctional kyphosis and spinal growth from T1 to S1.Aims
Patients and Methods
The primary aim of this study was to evaluate the performance
and safety of magnetically controlled growth rods in the treatment
of early onset scoliosis. Secondary aims were to evaluate the clinical
outcome, the rate of further surgery, the rate of complications,
and the durability of correction. We undertook an observational prospective cohort study of children
with early onset scoliosis, who were recruited over a one-year period
and followed up for a minimum of two years. Magnetically controlled
rods were introduced in a standardized manner with distractions
performed three-monthly thereafter. Adverse events which were both related
and unrelated to the device were recorded. Ten children, for whom
relevant key data points (such as demographic information, growth
parameters, Cobb angles, and functional outcomes) were available,
were recruited and followed up over the period of the study. There
were five boys and five girls. Their mean age was 6.2 years (2.5
to 10).Aims
Patients and Methods
Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (Objectives
Materials and Methods