Advertisement for orthosearch.org.uk
Results 341 - 360 of 2367
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1083 - 1083
1 Sep 2001
SAHNI V


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 464 - 464
1 Apr 2000
BERNARD J


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 562 - 562
1 Apr 2007
KURUP HV


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 697 - 697
1 Jul 1997
HARRINGTON P SMYTH H FENELON GC SHARIF I


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 170 - 170
1 Jan 1997
SMITH RM MATTHEWS S


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 170 - 170
1 Jan 1997
TENNET TD BIRCH NC EASTWOOD DM


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 683 - 683
1 Jul 1996
ROBERTS S THOMAS P


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 158 - 159
1 Jan 1995
Shenolikar A Hoddinott C


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 670 - 670
1 Jul 1994
Tanna D


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 496 - 497
1 May 1994
Gregson P Thomas P


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 86 - 87
1 Jan 1991
Salam A Eyres K Cleary J el-Sayed H

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 56 - 56
1 Jan 1987
de Souza L


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 4 | Pages 771 - 773
1 Nov 1967
Evans TA Stone KH Bailey D


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 652 - 653
1 Nov 1954
Merryweather R


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 1 | Pages 70 - 71
1 Feb 1952
Nisbet NW


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques.

A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 463 - 463
1 Apr 2000
TAN JW


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 152 - 153
1 Jan 2000
EARNSHAW S


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 584 - 587
1 Jul 1996
Leunig M Hertel R

We present three young men who sustained closed diaphyseal fracture of the tibia and later developed severe osteocutaneous necrosis induced by heat during intramedullary reaming. They all had a narrow medullary cavity and in all a tourniquet had been used. Each developed a pretibial cutaneous blister soon after operation. In the following month severe osteomyelitis ensued, requiring segmental resection and osteocutaneous reconstruction.