We hypothesised that the removal of the subchondral
bone plate (SCBP) for cemented acetabular component fixation in
total hip arthroplasty (THA) offers advantages over retention by
improving the cement-bone interface, without jeopardising implant
stability. We have previously published two-year follow-up data
of a randomised controlled trial (RCT), in which 50 patients with
primary osteoarthritis were randomised to either retention or removal
of the SCBP. The mean age of the retention group (n = 25, 13 males)
was 70.0 years ( Cite this article:
The purpose of this study was to develop a prognostic model for
predicting survival of patients undergoing surgery owing to metastatic
bone disease (MBD) in the appendicular skeleton. We included a historical cohort of 130 consecutive patients (mean
age 64 years, 30 to 85; 76 females/54 males) who underwent joint
arthroplasty surgery (140 procedures) owing to MBD in the appendicular
skeleton during the period between January 2003 and December 2008.
Primary cancer, pre-operative haemoglobin, fracture Aims
Methods
The optimal management of intracapsular fractures of the femoral
neck in independently mobile patients remains open to debate. Successful
fixation obviates the limitations of arthroplasty for this group
of patients. However, with fixation failure rates as high as 30%,
the outcome of revision surgery to salvage total hip arthroplasty
(THA) must be considered. We carried out a systematic review to
compare the outcomes of salvage THA and primary THA for intracapsular
fractures of the femoral neck. We performed a Preferred Reporting Items for Systematic Reviews
and Meta-Analysis (PRISMA) compliant systematic review, using the
PubMed, EMBASE and Cochrane libraries databases. A meta-analysis
was performed where possible, and a narrative synthesis when a meta-analysis
was not possible.Aims
Patients and Methods
Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters.Objectives
Methods
The National Joint Registry for England, Wales and Northern Ireland
(NJR) has extended its scope to report on hospital, surgeon and
implant performance. Data linkage of the NJR to the London Implant
Retrieval Centre (LIRC) has previously evaluated data quality for
hip primary procedures, but did not assess revision records. We analysed metal-on-metal hip revision procedures performed
between 2003 and 2013. A total of 69 929 revision procedures from
the NJR and 929 revised pairs of components from the LIRC were included.Aims
Methods
The October 2015 Foot &
Ankle Roundup360 looks at: TightRope in Weber C fractures; A second look at the TightRope; Incisional VAC comes of age?; Platelet-derived growth factor and ankle fusions; Achilles tendon rehab in the longer term following surgery; Telemedicine for diabetic foot ulcer
Excision of the proximal femur for tumour with
prosthetic reconstruction using a bipolar femoral head places a considerable
load on the unreplaced acetabulum. We retrospectively reviewed the changes which occur around the
affected hip joint by evaluating the post-operative radiographs
of 65 consecutive patients who underwent proximal prosthetic arthroplasty
of the femur, and in whom an acetabular component had not been used.
There were 37 men and 28 women with a mean age of 57.3 years (17
to 93). Radiological assessment included the extent of degenerative
change in the acetabulum, heterotopic ossification, and protrusio
acetabuli. The mean follow-up was 9.1 years (2 to 11.8). Degenerative changes
in the acetabulum were seen in three patients (4.6%), Brooker grade
1 or 2 heterotopic ossification in 17 (26%) and protrusion of the
prosthetic head in nine (13.8%). A total of eight patients (12.3%) needed a revision. Five were
revised to the same type of prosthesis and three (4.6%) were converted
to a total hip arthroplasty. We conclude that radiological evidence of degenerative change,
heterotopic ossification and protrusion occur in a few patients
who undergo prosthetic arthroplasty of the proximal femur for tumour.
The limited extent of these changes and the lack of associated symptoms
do not justify the routine arthroplasty of the acetabulum in these patients. Cite this article:
The October 2015 Children’s orthopaedics Roundup360 looks at: Radiographic follow-up of DDH; When the supracondylar goes wrong; Apophyseal avulsion fractures; The ‘pulled elbow’; Surgical treatment of active or aggressive aneurysmal bone cysts in children; Improving stability in supracondylar fractures; Biological reconstruction may be preferable in children’s osteosarcoma; The paediatric hip fracture
We evaluated clinical and radiographic outcomes of total shoulder
arthroplasty (TSA) using the second-generation Trabecular Metal
(TM) Glenoid component. The first generation component was withdrawn
in 2005 after a series of failures were reported. Between 2009 and
2012, 40 consecutive patients with unilateral TSA using the second-generation
component were enrolled in this clinical study. The mean age of
the patients was 63.8 years (40 to 75) and the mean follow-up was
38 months (24 to 42). Patients were evaluated using the Constant score (CS), the American
Shoulder and Elbow Surgeons (ASES) score and routine radiographs.Aims
Methods
The use of robotics in arthroplasty surgery is expanding rapidly as improvements in the technology evolve. This article examines current evidence to justify the usage of robotics, as well as the future potential in this emerging field.
When fracture of an extensively porous-coated
femoral component occurs, its removal at revision total hip arthroplasty
(THA) may require a femoral osteotomy and the use of a trephine.
The remaining cortical bone after using the trephine may develop
thermally induced necrosis. A retrospective review identified 11
fractured, well-fixed, uncemented, extensively porous-coated femoral
components requiring removal using a trephine with a minimum of
two years of follow-up. The mean time to failure was 4.6 years (1.7 to 9.1, standard
deviation ( A total of four patients (36.4%) required further revision: three
for instability and one for fracture of the revision component.
There was no statistically significant difference in the mean Harris
hip score before implant fracture (82.4; These findings suggest that removal of a fractured, well-fixed,
uncemented, extensively porous-coated femoral component using a
trephine does not compromise subsequent fixation at revision THA
and the patient’s pre-operative level of function can be restored.
However, the loss of proximal bone stock before revision may be associated
with a high rate of dislocation post-operatively. Cite this article:
The purpose of this study was to evaluate and
compare the effect of short segment pedicle screw instrumentation and
an intermediate screw (SSPI+IS) on the radiological outcome of type
A thoracolumbar fractures, as judged by the load-sharing classification,
percentage canal area reduction and remodelling. We retrospectively evaluated 39 patients who had undergone hyperlordotic
SSPI+IS for an AO-Magerl Type-A thoracolumbar fracture. Their mean
age was 35.1 (16 to 60) and the mean follow-up was 22.9 months (12
to 36). There were 26 men and 13 women in the study group. In total,
18 patients had a load-sharing classification score of seven and
21 a score of six. All radiographs and CT scans were evaluated for
sagittal index, anterior body height compression (%ABC), spinal
canal area and encroachment. There were no significant differences
between the low and high score groups with respect to age, duration
of follow-up, pre-operative sagittal index or pre-operative anterior
body height compression (p = 0.217, 0.104, 0.104, and 0.109 respectively).
The mean pre-operative sagittal index was 19.6° (12° to 28°) which
was corrected to -1.8° (-5° to 3°) post-operatively and 2.4° (0°
to 8°) at final follow-up (p = 0.835 for sagittal deformity). No
patient needed revision for loss of correction or failure of instrumentation. Hyperlordotic reduction and short segment pedicle screw instrumentation
and an intermediate screw is a safe and effective method of treating
burst fractures of the thoracolumbar spine. It gives excellent radiological
results with a very low rate of failure regardless of whether the
fractures have a high or low load-sharing classification score. Cite this article
We analysed the outcome of patients with primary
non-metastatic diaphyseal sarcomas who had Extracorporeal irradiation is an oncologically safe and inexpensive
technique for limb salvage in diaphyseal sarcomas and has good functional
results.
This pilot study reports the clinical outcomes
of a combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty in patients with rotatator cuff arthropathy. A
total of 30 patients (30 shoulders; eight men and 22 women) with
a mean age of 74 years (55 to 84) were assessed at a mean follow-up
of 31 months (24 to 60). The inclusion criteria were painful cuff
tear arthropathy with normal deltoid function and a non-degenerative subscapularis
muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles
score, the Japanese Orthopaedic Association score, and the Oxford
Shoulder Score. Radiographic measurements included the centre of
rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively.
The active flexion and external rotation improved significantly
at the most recent follow-up (p <
0.035). Although the mean centre
of rotation distance changed significantly (p <
0.001), the mean
length of the deltoid did not change significantly from the pre-operative
value (p = 0.29). The change in the length of the deltoid with <
100° flexion was significantly less than that with >
100° (p <
0.001). Progressive erosion of the glenoid was seen in four patients.
No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty effectively restored function and relieved pain
in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5.
This prospective study reports the 15-year survival and ten-year
functional outcome of a consecutive series of 1000 minimally invasive
Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women,
52%, mean age 66 years; 32 to 88). These were implanted by two surgeons
involved with the design of the prosthesis to treat anteromedial
osteoarthritis and spontaneous osteonecrosis of the knee, which
are recommended indications. Patients were prospectively identified
and followed up independently for a mean of 10.3 years (5.3 to 16.6). At ten years, the mean Oxford Knee Score was 40 (standard deviation
( This is the only large series of minimally invasive UKAs with
15-year survival data. The results support the continued use of
minimally invasive UKA for the recommended indications. Cite this article:
We reviewed the outcome of 69 uncemented, custom-made,
distal femoral endoprosthetic replacements performed in 69 patients
between 1994 and 2006. There were 31 women and 38 men with a mean
age at implantation of 16.5 years (5 to 37). All procedures were
performed for primary malignant bone tumours of the distal femur.
At a mean follow-up of 124.2 months (4 to 212), 53 patients were
alive, with one patient lost to follow-up. All nine implants (13.0%)
were revised due to aseptic loosening at a mean of 52 months (8
to 91); three implants (4.3%) were revised due to fracture of the
shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic
fracture. Bone remodelling associated with periosteal cortical thinning
adjacent to the uncemented intramedullary stem was seen in 24 patients
but this did not predispose to failure. All aseptically loose implants
in this series were diagnosed to be loose within the first five
years. The results from this study suggest that custom-made uncemented
distal femur replacements have a higher rate of aseptic loosening
compared to published results for this design when used with cemented
fixation. Loosening of uncemented replacements occurs early indicating
that initial fixation of the implant is crucial. Cite this article:
Failed internal fixation of a fracture of the
proximal humerus produces many challenges with limited surgical options.
The aim of this study was to evaluate the clinical outcomes after
the use of a reverse shoulder arthroplasty under these circumstances.
Between 2007 and 2012, 19 patients (15 women and four men, mean
age 66 years; 52 to 82) with failed internal fixation after a proximal
humeral fracture, underwent implant removal and reverse shoulder arthroplasty
(RSA). The mean follow-up was 36 months (25 to 60). The mean American
Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019).
The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p
= 0.020), and the mean visual analogue scale for pain improved from
6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7°
to 101.1° (p <
0.001), mean abduction from 58.7° to 89.1° (p
= 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043)
and mean internal rotation from buttocks to L4 (p = 0.034). A major
complication was recorded in five patients (26%) (one intra-operative
fracture, loosening of the humeral component in two and two peri-prosthetic
fractures). A total of 15 patients (79%) rated their outcome as
excellent or good, one (5%) as satisfactory, and three (16%) as
unsatisfactory. An improvement in outcomes and pain can be expected when performing
a RSA as a salvage procedure after failed internal fixation of a
fracture of the proximal humerus. Patients should be cautioned about
the possibility for major complications following this technically
demanding procedure. Cite this article:
Little is known about the long-term outcome of
mobile-bearing total ankle replacement (TAR) in the treatment of end-stage
arthritis of the ankle, and in particular for patients with inflammatory
joint disease. The aim of this study was to assess the minimum ten-year
outcome of TAR in this group of patients. We prospectively followed 76 patients (93 TARs) who underwent
surgery between 1988 and 1999. No patients were lost to follow-up.
At latest follow-up at a mean of 14.8 years (10.7 to 22.8), 30 patients
(39 TARs) had died and the original TAR remained Cite this article:
The April 2015 Children’s orthopaedics Roundup360 looks at: Reducing the incidence of DDH – is ‘back carrying’ the answer?; Surgical approach and AVN may not be linked in DDH; First year routine radiographic follow up for scoliosis not necessary; Diagnosis of osteochondritis dessicans; Telemedicine in paediatrics; Regional anesthesia in supracondylar fractures?