Advertisement for orthosearch.org.uk
Results 341 - 360 of 8431
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 2 | Pages 237 - 244
1 May 1961
London PS

1. The bad reputation of fractures of the scaphoid bone is based on a) past disasters caused by inadequate splintage and premature resort to operation; and b) selection of disabling cases for publication. 2. The results obtained in five series comprising over 1,000 fractures suggest that 95 per cent of adequately studied fractures less than a month old unite if properly treated. 3. Sixty cases of established non-union have provided evidence that disability is almost always the result of further injury and that the disability is usually relieved by a short time in plaster. 4. There is no evidence to support the widely held beliefs that a) union by bone can occur only if the fracture is immobilised throughout the process; and b) union after prolonged immobilisation is due to the immobilisation. 5. A policy of treating the wrist and not merely its radiological appearances is advocated


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 102 - 103
1 Jan 2005
Eshete M

A two-year retrospective survey in southern Ethiopia revealed that 49 amputations had been performed, 25 of which were for gangrene following tight splintage applied by traditional bone setters. The aim of this study was to determine if it was possible to reduce this incidence of gangrene by offering one-day instructional courses to bone setters. In ten separate one-day courses 112 tradition healers attended. In addition, two-day courses were given to local health assistants, who also received written instructions for the safe care of fractures. A two-year prospective study revealed a marked reduction in amputations, from 49 to 25, with only seven rather than 25 being required for gangrene. We found that it is possible to educate traditional healers so that fewer gangrenous limbs require to be amputated


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 161 - 166
1 Jan 1997
Deijkers RLM Bloem RM Petit PLC Brand R Vehmeyer SBW Veen MR

We analysed the bacterial contamination of 1999 bone allografts retrieved from 200 cadaver donors under sterile operating conditions. The effect of various factors on the relative risk of contamination was estimated using a multiple logistic regression model. Organisms of low pathogenicity were cultured from 50% of the grafts and of high pathogenicity from 3%. The risk of contamination with low pathogenic organisms (mainly skin commensals) increased by a factor of 1.6 for each member added to the procurement team. The risk of contamination with high pathogenic organisms (mainly contaminants from the gastrointestinal tract) was 3.4 times higher in donors with a traumatic cause of death and 5.2 times higher in those with a positive blood culture. Preceding organ procurement did not significantly influence the risk of contamination. Rinsing the graft with an antibiotic solution was not an effective decontamination method. The major source of contamination is exogenous and is strongly influenced by the procurement team. Contamination from endogenous sources can be controlled by donor selection. We discuss methods that can be used to decrease contamination and the rate of discarding of bone allografts


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 3 - 16
1 Feb 1974
Ohta Y Matsunaga H

1. A three-year survey of avascular necrosis of bone has been carried out in a community of some 400 professional divers for shell-fish who had used no modern technique of decompression. 2. Of 301 divers radiographed, 152 (50·5 per cent) had bone lesions. 3. The incidence of bone necrosis increased in proportion to the length of diving experience, being highest in men with over ten years, experience. 4. The incidence was also higher in men who usually dived deeper than thirty metres. 5. There was a high incidence in men with a history of the bends but no significant relationship between the sites of the bends and those of the lesions. 6. Bone lesions were more frequently multiple than solitary. 7. The upper end of the humerus was significantly more affected than the upper end of the femur or tibia, but not significantly more than the lower end of the femur. 8. At the upper ends of the humerus and femur the lesions were more frequently unilateral than bilateral


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 216 - 229
1 May 1972
McGrath PJ

1. Fifty-five giant-cell tumours of bone are described in fifty-two patients of whom thirty-five were women. The highest incidence was in the third and fourth decades. 2. The tumours were characteristic radiologically: they all occurred in skeletally mature patients, and chiefly in the expanded extremities of long bones. 3. Histological grading was not done, the tumours being designated typical or malignant. 4. Curettage and graft, resection, radiotherapy and amputation were the basic forms of treatment. Amputation has an occasional place in primary treatment and radiotherapy should be confined to tumours in surgically inaccessible sites. 5. Resection is the method of choice for tumours in suitable sites, such as the upper end of the fibula ; careful curettage and grafting should be used to preserve the function of a large joint. 6. Recurrences within two years should be treated by limited resection without preliminary biopsy. Late recurrences must have a biopsy taken to establish the diagnosis before planning treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 213 - 221
1 May 1977
Roberts P Price C

Nineteen chondrosarcomas are reported arising in proximal phalanges or metacarpal bones of the hand mainly in elderly patients, predominantly women. The usual clinical presentation was of a progressively painful large tumour, often arising in a dormant lesion near the metacarpo-phalangeal joint. Radiologically most showed some bone expansion with a poorly defined area of destruction and a considerable soft-tissue swelling. Histologically, malignancy was usually obvious, but confusion might arise from the inclusion of bland areas of chondromatous tissue that probably represented the original lesion. Four tumours, initially curetted and grafted, recurred locally and necessitated amputation of the digit or ray. Amputation was the primary treatment for fourteen other tumours and was curative except in one patient who eventually needed amputation through the forearm for a large second recurrence. One tumour was satisfactorily controlled by excision of the affected phalanx. None of these nineteen tumours is known to have metastasised. Correct treatment implies a carefully considered balance between conservation of function and complete removal of all tumour tissue


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 555 - 561
1 Apr 2014
Igarashi K Yamamoto N Shirai T Hayashi K Nishida H Kimura H Takeuchi A Tsuchiya H

In 1999, we developed a technique for biological reconstruction after excision of a bone tumour, which involved using autografts of the bone containing the tumour treated with liquid nitrogen. We have previously reported the use of this technique in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction using this technique. A total of 33 patients died and three were lost to follow-up, at a mean of 23 months (2 to 56) post-operatively, leaving 36 patients available for a assessment at a mean of 101 months 16 to 163) post-operatively. The methods of reconstruction included an osteo-articular graft in 16, an intercalary in 13 and, a composite graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%), good in seven (19.4%), and fair in three (8.3%) according to the functional evaluation system of Enneking. No recurrent tumour occurred within the grafts. The autografts survived in 29 patients (80.6%), and the rates of survival at five and ten years were 86.1% and 80.6 %, respectively. Seven of 16 osteo-articular grafts (44%) failed because of fracture or infection, but all the composite and intercalary grafts survived. The long-term outcomes of frozen autografting, particularly using composite and intercalary grafts, are satisfactory and thus represent a good method of treatment for patients with a sarcoma of bone or soft tissue. Cite this article: Bone Joint J 2014;96-B:555–61


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 42 - 50
1 Jan 1996
Murray DW Wilson-MacDonald J Morscher E Rahn BA Käslin M

We used a rabbit model to investigate the mechanism by which the angulation of fractures is corrected in children. We produced a transverse proximal tibial fracture in one leg of 12 eight-week-old New Zealand white rabbits and measured bone alignment and length and the patterns of bone growth and remodelling. The angle between the joint surfaces changed rapidly to correct the alignment of the limb as a result of asymmetrical growth of epiphyseal plates. In an adult with closed plates, the angle between the joint surfaces cannot therefore improve. The angle at the fracture itself showed slow improvement because of bone drift and the asymmetrical growth of the epiphyseal plates. Remodelling corrected the shape of the bone in the region of the fracture. Periosteal division on the convex side increased the growth of the epiphyseal plate on that side, thus slowing the correction. The effect was relatively small, providing an indication that factors other than the periosteum are important in inducing correction. External torsional deformities developed because of helical growth at the plate. This was probably caused by abnormal posture which induced a torque at the growth plate. Helical growth is the mechanism by which rotational deformities can occur and correct


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 228 - 231
1 Feb 2008
Buttaro M Araujo GS Araujo ES Comba F Piccaluga F

Metal meshes are used in revision surgery of the hip to contain impacted bone grafts in cases with cortical or calcar defects in order to provide rotational stability to the stem. However, the viability of bone allografts under these metal meshes has been uncertain. We describe the histological appearances of biopsies obtained from impacted bone allografts to the calcar contained by a metal mesh in two femoral reconstructions which needed further surgery at 24 and 33 months after the revision procedure. A line of osteoid and viable new bone was observed on the surface of necrotic trabeculae. Active bone marrow between these trabeculae showed necrotic areas in some medullary spaces with reparative fibrous tissue and isolated reactive lymphocytes. This is interpreted as reparative changes after revascularisation of the cancellous allografts. These pathological findings are similar to those reported in allografts contained by cortical host bone and support the hypothesis that incorporation of morcellised bone under metal meshes is not affected by these devices


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 265 - 268
1 Mar 1984
Bertoni F Calderoni P Bacchini P Campanacci M

The clinical and pathological features of six cases of desmoplastic fibroma of bone are presented. Desmoplastic fibroma is rarely seen as a primary tumour of bone; when it does occur the sites of predilection are the long bones, but other sites such as the scapula and os calcis can be involved. Radiographically the lesion tends to expand the bone from within; it is well-demarcated and lytic, often with a trabeculated soap-bubble appearance. The cellular structure and the morphological arrangement are similar to those of aggressive fibromatosis of soft tissues. Differential diagnosis from malignant spindle-cell lesions of bone is important because the treatment of choice for desmoplastic fibroma of bone is simply excision with a thin layer of healthy tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 997 - 1002
1 Aug 2006
Vendittoli P Lavigne M Girard J Roy AG

We have undertaken a prospective, randomised study to compare conservation of acetabular bone after total hip replacement and resurfacing arthroplasty of the hip. We randomly assigned 210 hips to one of the two treatment groups. Uncemented, press-fit acetabular components were used for both. No significant difference was found in the mean diameter of acetabular implant inserted in the groups (54.74 mm for total hip replacement and 54.90 mm for resurfacing arthroplasty). In seven resurfacing procedures (6.8%), the surgeon used a larger size of component in order to match the corresponding diameter of the femoral component. With resurfacing arthroplasty, conservation of bone is clearly advantageous on the femoral side. Our study has shown that, with a specific design of acetabular implant and by following a careful surgical technique, removal of bone on the acetabular side is comparable with that of total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 467 - 471
1 Apr 2006
Leichtle UG Leichtle CI Schmidt B Martini F

Peri-prosthetic bone loss caused by stress shielding may be associated with aseptic loosening of femoral components. In order to increase primary stability and to reduce stress shielding, a three-dimensional, cementless individual femoral (Evolution K) component was manufactured using pre-operative CT scans. Using dual energy x-ray absorptiometry, peri-prosthetic bone density was measured in 43 patients, three months, six months, 3.6 and 4.6 years after surgery. At final follow-up there was a significant reduction in mean bone density in the proximal Gruen zones of −30.3% (zone 7) and −22.8% (zone 1). The density in the other zones declined by a mean of between −4% and −16%. We conclude that the manufacture of a three-dimensional, custom-made femoral component could not prevent a reduction in peri-prosthetic bone density


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 862 - 869
1 Nov 1992
Postacchini F Cinotti G

We reviewed 40 patients treated surgically for lumbar stenosis at an average time of 8.6 years after operation. In 32, total laminectomy had been performed and in eight bilateral laminotomy, both at one or more levels. Of the 16 patients with degenerative spondylolisthesis, ten had had a concomitant spinal fusion. Patients were assigned to one of four groups according to the amount of bone regrowth: group 0 had no regrowth and groups I, II, and III, had mild, moderate or marked regrowth, respectively. Only 12% of the patients showed no bone regrowth; 48% were assigned to group I, 28% to group II and 12% to group III. Imaging studies showed varying degrees of recurrent stenosis in patients with moderate or marked bone regrowth. All patients with degenerative spondylolisthesis showed bone regrowth, which was more severe in those who had not had a fusion. The clinical results were satisfactory in most of the patients with mild or no bone regrowth and significantly less good in those with moderate or marked regrowth. In the group with degenerative spondylolisthesis, the proportion of satisfactory results was significantly higher in patients who had had spinal fusion. The long-term results of surgery for lumbar stenosis depend both upon the amount of bone regrowth and the degree of postoperative vertebral stability


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1339 - 1343
1 Oct 2012
Cross MB Dolan MM Sidhu GS Nguyen J Mayman DJ Su EP

The purpose of this study was to compare the amount of acetabular bone removed during hip resurfacing (HR) and cementless total hip replacement (THR), after controlling for the diameter of the patient’s native femoral head. Based on a power analysis, 64 consecutive patients (68 hips) undergoing HR or THR were prospectively enrolled in the study. The following data were recorded intra-operatively: the diameter of the native femoral head, the largest reamer used, the final size of the acetabular component, the size of the prosthetic femoral head and whether a decision was made to increase the size of the acetabular component in order to accommodate a larger prosthetic femoral head. Results were compared using two-sided, independent samples Student’s t-tests. A statistically significant difference was seen in the mean ratio of the size of the acetabular component to the diameter of the native femoral head (HR: 1.05 (. sd. 0.04) versus THR: 1.09 (. sd. 0.05); p <  0.001) and largest acetabular reamer used to the diameter of the native femoral head (HR: 1.03 (. sd. 0.04) versus THR: 1.09 (. sd. 0.05); p < 0.001). The ratios varied minimally when the groups were subdivided by gender, age and obesity. The decision to increase the size of the acetabular component to accommodate a larger femoral head occurred more often in the THR group (27% versus 9%). Despite the emphasis on avoiding damage to the femoral neck during HR, the ratio of the size of the acetabular component to the diameter of the native femoral head was larger in cementless THR than in HR


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 915 - 919
1 Aug 2002
Bechtold JE Kubic V Søballe K

We have investigated whether the presence of polyethylene (PE) alone is sufficient to cause an aggressive periprosthetic tissue response, or whether certain mechanical interface conditions can allow bone to grow while in the presence of PE. An experimental implant was loaded in the presence and absence of particulate PE under stable and unstable conditions. Bone with a thin, discontinuous fibrous membrane formed in both groups of stable implants, either in the presence or absence of PE. By contrast, a continuous fibrous membrane consistently formed in both groups of unstable implants. The membrane consisted of loose fibrous connective tissue when PE was absent, and dense connective tissue with macrophages and a synovial lining when PE was present. In this model, if the interface was stable, the presence of PE was not sufficient to prevent the formation of bone or to produce a phagocytic tissue response. Only when the interface was unstable did a fibrous membrane form, and only then in the presence of PE


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 425 - 433
1 Apr 2007
Little DG Ramachandran M Schindeler A

The literature on fracture repair has been reviewed. The traditional concepts of delayed and nonunion have been examined in terms of the phased and balanced anabolic and catabolic responses in bone repair. The role of medical manipulation of these inter-related responses in the fracture healing have been considered


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 746 - 750
1 Jun 2011
Zampelis V Ornstein E Franzén H Atroshi I

Previously, radiostereometric analysis following hip revision performed using impacted morsellised allograft bone and a cemented Exeter stem has shown continuous subsidence of the stem for up to five years. It is not known whether the subsidence continues thereafter. In our study, 17 of 25 consecutive osteo-arthritic patients with aseptically loose stems who underwent first-time revision using impacted morsellised allograft bone and a cemented Exeter stem were followed by yearly radiostereometric examinations for nine years. The mean subsidence at six weeks was 1.1 mm (0.1 to 2.3), from six weeks to one year 1.3 mm (0 to 2.6), from one to five years 0.7 mm (0 to 2.0), and from five to nine years 0.7 mm (0.1 to 3.1). That from six weeks to nine years was 2.7 mm (0 to 6.4) (95% confidence interval 2.0 to 3.5). The Charnley pain score significantly improved after revision, and was maintained at nine years, but walking ability deteriorated slightly as follow-up extended. Of the eight patients who were not followed for nine years, two had early subsidence exceeding 11 mm. Our findings show that in osteo-arthritic patients who undergo revision for aseptic loosening of the stem using impacted morsellised allograft bone and a cemented Exeter stem, migration of the stem continues over nine years at a slower rate after the first year, but without clinical deterioration or radiological loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 758 - 762
1 Nov 1957
Lavine LS Burger M Sobel AE

1. The influence of various methods of preserving bone on the calcifying mechanism of the tibial epiphysial cartilage of rachitic rats was studied. An in vitro calcification technique was employed. 2. Preservation by deep freezing, aqueous merthiolate, boiling, or acetone inactivated the calcifying mechanism. 3. The inactivation was reversed with calcium ions, most readily in the deep-frozen bones, less readily in the merthiolate treated bones, still less readily in the acetone stored bones, and least in boiled bones. 4. Exposure to calcium ions before preservation in the deep-freeze chest prevented inactivation. 5. The inactivation, reactivation and survival of the calcifying mechanism were confirmed by metachromasia studies. 6. The theory of the mode of action of calcium chloride on reactivation and survival of the calcifying mechanism is presented


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 245 - 248
1 Mar 2002
Tsuchiya H Abdel-Wanis ME Uehara K Tomita K Takagi Y Yasutake H

We describe a consecutive series of 26 patients with simple bone cysts who were treated by curettage, multiple drilling and continuous decompression by the insertion of either a cannulated screw or a pin. In the first 15 patients we used titanium cannulated screws (group 1) and in the next 11 a cannulated hydroxyapatite pin (group 2). Satisfactory healing was achieved in 12 patients in group 1 (80%) and in all in group 2. This technique seems to be a promising option for the treatment of simple bone cysts. The cannulated hydroxyapatite pin is recommended because of its higher success rate and the fact that it does not need to be removed


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1212 - 1216
1 Sep 2006
Rastogi S Varshney MK Trikha V Khan SA Choudhury B Safaya R

Aneurysmal bone cyst is a rare tumour-like lesion which develops during growth. Our aim was to determine the efficacy of the administration of percutaneous intralesional 3% polidocanol (hydroxypolyaethoxydodecan) as sclerotherapy. Between July 1997 and December 2004 we treated 72 patients (46 males, 26 females) with a histologically-proven diagnosis of aneurysmal bone cyst, at various skeletal sites using this method. The sclerotherapy was performed under fluoroscopic guidance and general anaesthesia or sedation and local anaesthesia. The mean follow-up period was 34 months (26.5 to 80). The patients were evaluated using the Enneking system for functional assessment and all the lesions were radiologically quantified into four grades. The mean age of patients was 15.6 years (3 to 38) and the mean number of injections was three (1 to 5). Ten patients were cured by a single injection. The mean reduction in size of the lesion (radiological healing) was found to be 76.6% (61.9% to 93.2%) with a mean clinical response of 84.5% (73.4% to 100%). Recurrence was seen in two patients (2.8%) within two years of treatment and both were treated successfully by further sclerotherapy. Percutaneous sclerotherapy with polidocanol is a safe alternative to conventional surgery for the treatment of an aneurysmal bone cyst. It can be used at surgically-inaccessible sites and treatment can be performed on an out-patient basis