Total hip replacement in patients with Gaucher’s disease with symptomatic osteonecrosis of the femoral head is controversial because of the high early failure rates. We describe four patients who had an uncemented total hip replacement following enzyme replacement therapy for a median of two years and one month (1 to 9.8 years) prior to surgery, and who remained on treatment. At operation, the bone had a normal appearance and consistency. Histopathological examination showed that, compared with previous biopsies of untreated Gaucher’s disease, the Gaucher cell infiltrate had decreased progressively with therapy, being replaced by normal adipose tissue. The surfaces of viable bone beyond the osteonecrotic areas showed osteoblasts, indicating remodelling. In one case acetabular revision was carried out after 11 years and eight months. The three remaining patients had a mean follow-up of six years and four months (3.3 to 12 years). We recommend initiating enzyme replacement therapy at least one to two years prior to total hip replacement to facilitate bone remodelling and to allow implantation of uncemented components in these young patients.
We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.
The incidence of metastatic osteosarcoma is increasing because of improved results following multi-agent chemotherapy and resection of the primary tumour. Metastases occur most commonly in the lungs, whereas bowel metastases are rare. We describe a 25-year-old female who presented with melaena six years after successful resection of an osteosarcoma of her right femur, and one year after resection of a solitary pulmonary metastasis. Imaging revealed a lesion arising within both the duodenum and the pancreas for which a Whipple’s pancreatoduodenectomy was carried out, achieving complete resection. Histological examination confirmed the diagnosis of metastatic osteosarcoma. We believe this is only the second such case reported. At 11 months post-operatively she had no detectable disease. Although rare, osteosarcoma can metastasise to the intestine. The surgeon must be aware of this complication, and that bowel metastases are potentially resectable.
Injury to the spinal cord and kyphosis are the two most feared complications of tuberculosis of the spine. Since tuberculosis affects principally the vertebral bodies, anterior decompression is usually recommended. Concomitant posterior instrumentation is indicated to neutralise gross instability from panvertebral disease, to protect the anterior bone graft, to prevent graft-related complications after anterior decompression in long-segment disease and to correct a kyphosis. Two-stage surgery is usually performed in these cases. We present 38 consecutive patients with tuberculosis of the spine for whom anterior decompression, posterior instrumentation, with or without correction of the kyphus, and anterior and posterior fusion was performed in a single stage through an anterolateral extrapleural approach. Their mean age was 20.4 years (2.0 to 57.0). The indications for surgery were panvertebral disease, neurological deficit and severe kyphosis. The patients were operated on in the left lateral position using a ‘T’-shaped incision sited at the apex of kyphosis or lesion. Three ribs were removed in 34 patients and two in four and anterior decompression of the spinal cord was carried out. The posterior vertebral column was shortened to correct the kyphus, if necessary, and was stabilised by a Hartshill rectangle and sublaminar wires. Anterior and posterior bone grafting was performed. The mean number of vertebral bodies affected was 3.24 (2.0 to 9.0). The mean pre-operative kyphosis in patients operated on for correction of the kyphus was 49.08° (30° to 72°) and there was a mean correction of 25° (6° to 42°). All except one patient with a neural deficit recovered complete motor and sensory function. The mean intra-operative blood loss was 1175 ml (800 to 2600), and the mean duration of surgery 3.5 hours (2.7 to 5.0). Wound healing was uneventful in 33 of 38 patients. The mean follow-up was 33 months (11 to 74). None of the patients required intensive care. The extrapleural anterolateral approach provides simultaneous exposure of the anterior and posterior aspects of the spine, thereby allowing decompression of the spinal cord, posterior stabilisation and anterior and posterior bone grafting. This approach has much less morbidity than the two-stage approaches which have been previously described.
Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years. The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.
The outcome of one-stage bilateral open reduction through a medial approach for the treatment of developmental dysplasia of the hip in children under 18 months was studied in 23 children, 18 girls and five boys. Their mean age at operation was 10.1 months (6 to 17) and the mean follow-up was 5.4 years (3 to 8). Acceptable clinical and radiological results were achieved in 44 (95.7%) and 43 (93.5%) of 46 hips, respectively. Excellent results were significantly evident in patients younger than 12 months, those who did not require acetabuloplasty, those whose ossific nucleus had appeared, and in those who did not develop avascular necrosis. One-stage bilateral medial open reduction avoids the need for separate procedures on the hips and has the advantages of accelerated management and shorter immobilisation and rehabilitation than staged operations.
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
Panton-Valentine leukocidin secreted by The Panton-Valentine leukocidin toxin not only destroys host neutrophils, immunocompromising the patient, but also increases the risk of intravascular coagulopathy. This combination leads to widespread involvement of bone with glutinous pus which is difficult to drain, and makes the delivery of antibiotics and eradication of infection very difficult without surgical intervention.
Orthopaedic outcome measures are used to evaluate the effect of operative interventions. They are used for audit and research. Knowledge of these measures is becoming increasingly important with league tables comparing surgeons and hospitals being made accessible to the profession and the general public. Several types of tool are available to describe outcome after hip surgery such as generic quality-of-life questionnaires, disease-specific quality-of-life questionnaires, hip-specific outcome measures and general short-term clinical measures. We provide an overview of the outcome measures commonly used to evaluate hip interventions.
In developed countries, children with cerebral palsy are treated from the time of diagnosis. This is usually not the case in developing countries where such patients often present at an age when it is traditionally believed that if walking has not already commenced, it is unlikely to. This study reports the outcome of the surgical treatment of 85 spastic diplegic patients at a mean of 8.5 years (5 to 12). All presented as untreated non-walkers and had achieved sitting balance by the age of five to six years. They underwent single-event multilevel surgery followed by physiotherapy and orthotic support. For outcome assessment, a modified functional walking scale was used at a mean of 3.5 years (2 to 5) post-operatively. At all levels, static joint contractures had resolved almost completely. All patients improved and became walkers, 18 (21.2%) as exercise, 39 (45.9%) as household and 28 (33%) as community walkers. This study shows that children with cerebral palsy who cannot walk and have not been treated can be helped by single-event multilevel surgery, provided that inclusion criteria are followed and a structural, supervised rehabilitation programme is in place.
Sciatic nerve palsy is a recognised complication of primary total hip replacement. In our unit this complication was rare with an incidence of <
0.2% in the past ten years. We describe six cases of sciatic nerve palsy occurring in 355 consecutive primary total hip replacements (incidence 1.69%). Each of these palsies was caused by post-operative haematoma in the region of the sciatic nerve. Cases, which were recognised early and surgically-evacuated promptly, showed earlier and more complete recovery. Those patients for whom the diagnosis was delayed, and who were therefore managed expectantly, showed little or no recovery. Unexpected pain and significant swelling in the buttock, as well as signs of sciatic nerve irritation, suggest the presence of haematoma in the region of the sciatic nerve. It is, therefore, of prime importance to be vigilant for the features of a sciatic nerve palsy in the early post-operative period as, when recognised and treated early, the injury to the sciatic nerve may be reversed.
Implantation of allograft bone is an integral part of revision surgery of the hip. One major concern with its use is the risk of transmission of infective agents. There are a number of methods of processing allograft bone in order to reduce this risk. One method requires washing the tissue using pulsed irrigation immediately before implantation. We report the incidence of deep bacterial infection in 138 patients (144 revision hip arthroplasties) who had undergone implantation of allograft bone. The bone used was fresh-frozen, non-irradiated and pulse-washed with normal saline before implantation. The deep infection rate at a minimum follow-up of one year was 0.7%. This method of processing appears to be associated with a very low risk of allograft-related bacterial infection.
We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p <
0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group.
The risk of venous thromboembolism in patients following arthroplasty may be reduced by continuing chemical thromboprophylaxis for up to 35 days post-operatively. This prospective cohort study investigated the compliance of 40 consecutive consenting patients undergoing lower limb arthroplasty with self-administration of a recommended subcutaneous chemotherapeutic agent for six weeks after surgery. Compliance was assessed by examination of the patient for signs of injection, number of syringes used, and a self-report diary at the end of the six-week period. A total of 40 patients, 15 men and 25 women, were recruited. One woman was excluded because immediate post-operative complications prevented her participation. Self-administration was considered feasible in 87% of patients (95% confidence interval (CI) 76 to 98) at the time of discharge. Among this group of 34 patients, 29 (85%) were compliant (95% CI 73 to 97). Patients can learn to self-administer subcutaneous injections of thromboprophylaxis, and compliance with extended prophylaxis to six weeks is good.
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.
We prospectively studied the outcome of a protocol of prophylaxis for deep vein thrombosis (DVT) in 103 consecutive patients undergoing surgical stabilisation of pelvic and acetabular fractures. Low-molecular-weight heparin (LMWH) was administered within 24 hours of injury or on achieving haemodynamic stability. Patients were screened for proximal DVT by duplex ultrasonography performed ten to 14 days after surgery. The incidence of proximal DVT was 10% and of pulmonary embolus 5%. Proximal DVT developed in two of 64 patients (3%) who had received LMWH within 24 hours of injury, but in eight of 36 patients (22%) who received LMWH more than 24 hours after the injury (p <
0.01). We conclude that LMWH, when begun without delay, is a safe and effective method of thromboprophylaxis in high-risk patients with major pelvic or acetabular fractures.
Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry. Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 μg/l (0.55 to 2.55) and 1.28 μg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 μg/l (0.42 to 1.75) and 0.378 μg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p <
0.05). In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 μg/l (0.18 to 0.54) and 0.199 μg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 μg/l (0.17 to 0.5) and 0.194 μg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p >
0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p <
0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 μg/l) as in the controls (0.1934 μg/l), this difference was not statistically significant. (p >
0.05) The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.
The best treatment for the active and lucid elderly patient with a displaced intracapsular fracture of the femoral neck is still controversial. Randomised controlled trials have shown that a primary total hip replacement is superior to internal fixation as regards the need for secondary surgery, hip function and health-related quality of life. Despite good results achieved with total hip replacement in this group, most orthopaedic surgeons still advocate hemiarthroplasty for this injury. We studied 120 patients with a mean age of 81 years (70 to 90) with an acute displaced intracapsular fracture of the femoral neck. They were randomly allocated to be treated with either a bipolar hemiarthroplasty or total hip replacement. Outcome measurements included peri-operative data, general and hip-specific complications, hip function and health-related quality of life. The patients were reviewed at four and 12 months. The duration of surgery was longer in the total hip replacement group (102 minutes (70 to 151)) These results indicate that a total hip replacement provides better function than a bipolar hemiarthroplasty as soon as one year post-operatively, without increasing the complication rate. We recommend total hip replacement as the primary treatment for this group of patients.
This paper reviews the current literature concerning the main clinical factors which can impair the healing of fractures and makes recommendations on avoiding or minimising these in order to optimise the outcome for patients. The clinical implications are described.