header advert
Results 321 - 340 of 2551
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 409 - 413
1 Mar 2011
McCalden RW Charron KD Davidson RD Teeter MG Holdsworth DW

We present a case of early retrieval of an Oxinium femoral head and corresponding polyethylene liner where there was significant surface damage to the head and polyethylene. The implants were retrieved at the time of revision surgery to correct leg-length discrepancy just 48 hours after the primary hip replacement. Appropriate analysis of the retrieved femoral head demonstrated loss of the Oxinium layer with exposure of the underlying substrate and transfer of titanium from the acetabular shell at the time of a reduction of the index total hip replacement. In addition, the level of damage to the polyethylene was extensive despite only 48 hours in situ. The purpose of this report is to highlight the care that is required at the time of reduction, especially with these hard femoral counter-faces such as Oxinium. To our knowledge, the damage occurring at the time of reduction has not been previously reported following the retrieval of an otherwise well-functioning hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 751 - 754
1 Jun 2011
Choa R Gundle R Critchley P Giele H

Deep prosthetic joint infection remains an uncommon but serious complication of total hip replacement. We reviewed 24 patients with recalcitrant hip wounds following infected total hip replacement treated with either pedicled rectus femoris or vastus lateralis muscle flaps between 1998 and 2009. The mean age of the patients was 67.4 years (42 to 86) with ten men and 14 women. There had been a mean of four (1 to 8) previous attempts to close the wound. A total of 20 rectus femoris and five vastus lateralis flaps were used, with one of each type of flap failing and requiring further reconstruction. All patients had positive microbiology. At a mean follow-up of 47 months (9 to 128), 22 patients had a healed wound and two had a persistent sinus. The prosthesis had been retained in five patients. In the remainder it had been removed, and subsequently re-implanted in nine patients. Six patients continued to take antibiotics at final follow-up. This series demonstrates the effectiveness of pedicled muscle flaps in healing these infected wounds. The high number of previous debridements suggests that these flaps could have been used earlier


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1531 - 1532
1 Nov 2009
Moussallem CD El-Yahchouchi CA Charbel AC Nohra G

We present a case of delayed presentation of a subdural haematoma causing cauda equina syndrome which occurred 96 hours after a spinal anaesthetic had been administered for an elective total hip replacement in an 86-year-old man. The patient had received low-molecular-weight heparin anticoagulation which had been delayed until 12 hours postoperatively. No other cause of the haemorrhage could be identified


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 632 - 634
1 Nov 1984
Penman H Ring P

The occurrence of an osteosarcoma at the site of a cobalt-chrome total hip replacement is described, and the possibility of the tumour arising as a result of the liberation of cobalt particles is discussed. The experimental and clinical evidence relating tumour formation to the presence of particulate metals, and to the presence of solid and particulate polyethylene, is presented. It is considered that the risk of tumour formation at the site of any total hip replacement is very small


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 712 - 715
1 Jun 2006
Khanduja V Tek V Scott G

The aim of this study was to assess whether a femoral component which retained the neck reduced the incidence of leg-length inequality following total hip arthroplasty. A retrospective review was undertaken of 130 consecutive primary total hip arthroplasties performed between April 1996 and April 2004 using such an implant. There were 102 suitable patients for the study. Standardised pre- and post-operative pelvic radiographs were measured by an independent investigator to the nearest millimetre. The leg-length inequality was reduced from a mean pre-operative value of −0.71 cm to a mean of 0.11 cm post-operatively. Of the 102 patients 24 (23.5%) had an equal leg-length post-operatively, and 95 (93.1%) had a leg-length inequality between −1 cm and 1 cm


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 39 - 46
1 Jan 2011
Sukeik M Alshryda S Haddad FS Mason JM

We report a systematic review and meta-analysis of published randomised controlled trials evaluating the efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion in total hip replacement (THR). The data were evaluated using the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group. We identified 11 clinical trials which were suitable for detailed extraction of data. There were no trials that used TXA in revision THR. A total of seven studies (comprising 350 patients) were eligible for the blood loss outcome data. The use of TXA reduced intra-operative blood loss by a mean of 104 ml (95% confidence interval (CI) −164 to −44, p = 0.0006, heterogeneity I. 2. 0%), postoperative blood loss by a mean of 172 ml (95% CI −263 to −81, p = 0.0002, heterogeneity I. 2. 63%) and total blood loss by a mean of 289 ml (95% CI −440 to −138, p < 0.0002, heterogeneity I. 2. 54%). TXA led to a significant reduction in the proportion of patients requiring allogeneic blood transfusion (risk difference −0.20, 95% CI −0.29 to −0.11, p < 0.00001, I. 2. 15%). There were no significant differences in deep-vein thrombosis, pulmonary embolism, infection rates or other complications among the study groups


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 576 - 579
1 Jul 1991
Lachiewicz P Latimer H

We report six cases of contralateral limb involvement during total hip arthroplasty including swelling of the gluteal muscle compartments, rhabdomyolysis, myoglobinuria, and sciatic nerve palsy. The risk factors for such complications include obesity, prolonged operative time, and positioning in the lateral decubitus position. The laboratory and clinical findings are consistent with a gluteal muscle crush-injury with consequent compartment syndrome. The patients should be treated conservatively as symptoms can be expected to resolve


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 168 - 173
1 May 1980
Dobbs H

The survivorship of total hip replacements in patients operated on at the Royal National Orthopaedic Hospital has been analysed using standard actuarial methods. Between 1963 and 1972 173 metal-on-metal prostheses of various developmental designs were inserted. Between 1969 and 1972 248 prostheses of one design using a metal femoral component and plastic cup were used. The patients were surveyed retrospectively and for each the actual follow-up period was determined as well as the eventual outcome. The criterion of "survival" was that the prosthesis was still in situ and all such prostheses were regarded as "survivors", regardless of whether the patients experienced pain or loss of function. The survivorship was then determined by constructing life tables. The results indicate that for metal-on-metal prostheses the overall probability of survival was only 53 per cent after 11 years and the average annual probability of removal, irrespective of cause, was 5.5 per cent. The results were better for metal-on-plastic prostheses with figures of 88 per cent after eight years and 1.5 per cent respectively. For both prostheses the predominant reason for failure was loosening and the annual rate of removal for loosening increased as the follow-up time increased, suggesting that loosening was a wearing out process. The advantages of the survivorship method of analysis as compared with conventional methods are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 655 - 657
1 May 2006
Blake SM Kitson J Howell JR Gie GA Cox PJ

We describe a patient with cerebral palsy, of normal intelligence, who could not walk but who by the age of 16 had been successfully managed with a staged bilateral total hip arthroplasty using a constrained liner


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 57 - 60
1 Jan 1987
Ejsted R Olsen N

Ninety-seven revisions of total hip replacements are reviewed with a median time of observation of 47 months. Satisfactory pain relief was obtained in 86%. There were six complete failures which were reduced to three by further surgery. One hip became infected and was excised. In 12 cases the revisions were complicated by peroperative fractures and in five by dislocations. Radiographic analysis disclosed a high percentage of periarticular ossification and 25 cases of radiographic loosening of the femoral implant


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 902 - 907
1 Nov 1991
Llinas A Sarmiento A Ebramzadeh E Gogan W McKellop H

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 890 - 898
1 Jul 2015
Renkawitz T Weber M Springorum H Sendtner E Woerner M Ulm K Weber T Grifka J

We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated ‘femur-first’ total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated ‘femur-first’ group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups’ Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated ‘femur-first’ technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. Cite this article: Bone Joint J 2015; 97-B:890–8


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1636 - 1641
1 Dec 2010
McLaughlin JR Lee KR

We reviewed 123 second-generation uncemented total hip replacements performed on 115 patients by a single surgeon between 1993 and 1994. The acetabular component used in all cases was a fully porous-coated threaded hemispheric titanium shell (T-Tap ST) with a calcium ion stearate-free, isostatically compression-moulded polyethylene liner. The titanium femoral component used was a Taperloc with a reduced distal stem. No patient was lost to follow-up. Complete clinical and radiological follow-up was obtained for all 123 hips at a mean of 14 years (12 to 16). One femoral component was revised after a fracture, and three acetabular components for aseptic loosening. No additional femoral or acetabular components were judged loose by radiological criteria. Mild proximal femoral osteolysis was identified in two hips and minor acetabular osteolysis was present in four. The mean rate of penetration of the femoral head was 0.036 mm/year (0.000 to 0.227). These findings suggest that refinements in component design may be associated with excellent long-term fixation in cementless primary total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1021 - 1026
1 Aug 2011
Kalteis T Sendtner E Beverland D Archbold PA Hube R Schuster T Renkawitz T Grifka J

Orientation of the native acetabular plane as defined by the transverse acetabular ligament (TAL) and the posterior labrum was measured intra-operatively using computer-assisted navigation in 39 hips. In order to assess the influence of alignment on impingement, the range of movement was calculated for that defined by the TAL and the posterior labrum and compared with a standard acetabular component position (abduction 45°/anteversion 15°). With respect to the registration of the plane defined by the TAL and the posterior labrum, there was moderate interobserver agreement (r = 0.64, p < 0.001) and intra-observer reproducibility (r = 0.73, p < 0.001). The mean acetabular component orientation achieved was abduction of 41° (32° to 51°) and anteversion of 18° (−1° to 36°). With respect to the Lewinnek safe zone (abduction 40° ±10°, anteversion 15° ±10°), 35 of the 39 acetabular components were within this zone. However, there was no improvement in the range of movement (p = 0.94) and no significant difference in impingement (p = 0.085). Alignment of the acetabular component with the TAL and the posterior labrum might reduce the variability of acetabular component placement in total hip replacement. However, there is only a moderate interobserver agreement and intra-observer reliability in the alignment of the acetabular component using the TAL and the posterior labrum. No reduction in impingement was found when the acetabular component was aligned with the TAL and the posterior labrum, compared with a standard acetabular component position


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 218 - 222
1 Mar 1986
Ruddlesdin C Ansell B Arden G Swann M

The results of 75 total hip replacements in 42 children with juvenile chronic arthritis are reported after a mean follow-up of 5.4 years. Their ages ranged from 11 to nearly 17 years at operation and many had active disease. Severe pain and marked stiffness of the hips were limiting their independence. At least half of the children were still growing and continued to grow after operation. The patients were carefully selected and gratifying results were obtained, but pre-operative assessment and overall supervision by a rheumatologist are important. Technical difficulties related to the size and maldevelopment of the hip are discussed. There was no infection and the single case of loosening of a femoral component after nine years has been successfully revised


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 449 - 455
1 Apr 2011
Kim Y Kim J Park J Joo J

There have been comparatively few studies of the incidence of osteolysis and the survival of hybrid and cementless total hip replacements (THRs) in patients younger than 50 years of age. We prospectively reviewed 78 patients (109 hips) with a hybrid THR having a mean age of 43.4 years (21 to 50) and 79 patients (110 hips) with a cementless THR with a mean age of 46.8 years (21 to 49). The patients were evaluated clinically using the Harris hip score, the Western Ontario and McMaster Universities (WOMAC) osteoarthritis score and the University of California, Los Angeles (UCLA) activity score. Radiographs and CT scans were assessed for loosening and osteolysis. The mean follow-up was for 18.4 years (16 to 19) in both groups. The mean post-operative Harris hip scores (91 points versus 90 points), the mean WOMAC scores (11 points versus 13 points) and UCLA activity scores (6.9 points versus 7.1 points) were similar in both groups. The revision rates of the acetabular component (13% versus 16%) and the femoral component (3% versus 4%), and the survival of the acetabular component (87% versus 84%) and the femoral component (97% versus 96%) were similar in both groups. Although the long-term fixation of the acetabular metallic shell and the cemented and cementless femoral components was outstanding, wear and peri-acetabular osteolysis constitute the major challenges of THR in young patients


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 345 - 350
1 May 1995
Mathiesen E Ahlbom A Bermann G Lindgren J

The incidence of cancer after hip replacement was studied in the 1.6 million inhabitants of Stockholm County, Sweden. A cohort of 10,785 individuals who had had hip replacement between 1974 and 1988 was followed from the date of operation to the first malignant tumour, to death, or to the end of 1989. The follow-up was based on 58,437 person-years at risk as calculated from information obtained by record-linkage with the National Cancer Registry and the National Cause-of-Death Register. The Standardised Morbidity Ratio (SMR) for all cancer sites, disregarding the length of follow-up, was 0.96 (95% CI 0.90 to 1.03). For lymphoma and leukaemia the corresponding SMR was 0.89 (0.68 to 1.14). Our results do not support previous suggestions of an increased incidence of leukaemia and lymphoma after total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 844 - 846
1 Jun 2011
Sarasin SM Karthikeyan R Skinner P Nassef A Stockley I

Intrapelvic migration of the acetabular component of a total hip replacement, with severe acetabular destruction making reconstruction impossible, is very rare. We present a patient in whom the component was removed using a laparotomy and a transperitoneal approach with subsequent salvage using a saddle prosthesis and a total femoral replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 956 - 959
1 Sep 2003
Blom AW Taylor AH Pattison G Whitehouse S Bannister GC

Our aim in this study was to determine the outcome of hip arthroplasty with regard to infection at our unit. Infection after total joint arthroplasty is a devastating complication. The MRC study in 1984 recommended using vertical laminar flow and prophylactic antibiotics to reduce infection rates. These measures are now routinely used. Between 1993 and 1996, 1727 primary total hip arthroplasties and 305 revision hip arthroplasties were performed and 1567 of the primary and 284 of the revision arthroplasties were reviewed between five and eight years after surgery by means of a postal questionnaire, telephone interview or examination of the medical records of those who had died. Seventeen (1.08%) of the patients who underwent primary and six (2.1%) of those who underwent revision arthroplasty had a post-operative infection. Only 0.45% of patients who underwent primary arthroplasty required revision for infection. To our knowledge this is the largest multi-surgeon audit of infection after total hip replacement in the UK. The follow-up of between five and eight years is longer than that of most comparable studies. Our study has shown that a large cohort of surgeons of varying seniority can achieve infection rates of 1% and revision rates for infection of less than 0.5%


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 16 - 20
1 Jan 2005
Chougle A Hemmady MV Hodgkinson JP

We have assessed the long-term results of 292 cemented total hip replacements which were performed for developmental dysplasia of the hip in 206 patients. The mean age of the patients at operation was 42.6 years (15.9 to 79.5) and most (202) were women. The severity of dysplasia was graded according to both the Crowe and the Hartofilakidis classifications. A 22.25-mm Charnley head was always used and the acetabular components were inserted with cement into the true acetabulum. Bone grafting of the acetabulum, using the patient’s own femoral head, was performed on 48 occasions. At a mean follow-up of 15.7 years (2.2 to 31.2) the overall survival of the acetabular component was 78%. The main cause of revision was aseptic loosening (88.3%). The rate of survival at 20 years based on the Hartofilakidis classification was 76% in the dysplastic, 55% in the low-dislocation and 12% in the high-dislocation groups and on the Crowe classification, 72.7% for group I, 70.7% for group II, 36.7% for group III and 15.6% for group IV. There was no statistical correlation between bone grafting of the acetabulum and survival of the acetabular component. This study has shown a higher rate of failure of the acetabular component with increasing severity of hip dysplasia