The aim of this study was to evaluate the surgical management and outcome of patients with an acral soft-tissue sarcoma of the hand or foot. We identified 63 patients with an acral soft-tissue sarcoma who presented to our tertiary referral sarcoma service between 2000 and 2016. There were 35 men and 28 women with a mean age of 49 years (Aims
Patients and Methods
The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment. Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale.Aims
Patients and Methods
Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates. In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates. Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres. Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection. There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice. Cite this article:
Intra-articular 90Yttrium (90Y) is an adjunct
to surgical treatment by synovectomy for patients with diffuse-type tenosynovial
giant-cell tumour (dtTGCT) of the knee, with variable success rates.
Clinical information is, however, sparse and its value remains unclear.
We investigated the long-term outcome of patients who underwent synovectomy
with and without adjuvant treatment with 90Yttrium. All patients with dtTGCT of the knee who underwent synovectomy
between 1991 and 2014 were included in the study. Group A patients
underwent synovectomy and an intra-articular injection of 90Yttrium
between six and eight weeks after surgery. Group B patients underwent
surgery alone.Aims
Patients and Methods
The aim of this review was to evaluate the available literature
and to calculate the pooled sensitivity and specificity for the
different alpha-defensin test systems that may be used to diagnose
prosthetic joint infection (PJI). Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw,
Indiana) to diagnose PJI were identified from systematic searches
of electronic databases. The quality of the studies was evaluated
using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS)
tool. Meta-analysis was completed using a bivariate model.Aims
Materials and Methods
Recently, the field of tissue engineering has made numerous advances towards achieving artificial tendon substitutes with excellent mechanical and histological properties, and has had some promising experimental results. The purpose of this systematic review is to assess the efficacy of tissue engineering in the treatment of tendon injuries. We searched MEDLINE, Embase, and the Cochrane Library for the time period 1999 to 2016 for trials investigating tissue engineering used to improve tendon healing in animal models. The studies were screened for inclusion based on randomization, controls, and reported measurable outcomes. The RevMan software package was used for the meta-analysis.Objectives
Methods
Preserving growth following limb-salvage surgery of the upper
limb in children remains a challenge. Vascularized autografts may
provide rapid biological incorporation with the potential for growth
and longevity. In this study, we aimed to describe the outcomes
following proximal humeral reconstruction with a vascularized fibular
epiphyseal transfer in children with a primary sarcoma of bone.
We also aimed to quantify the hypertrophy of the graft and the annual
growth, and to determine the functional outcomes of the neoglenofibular
joint. We retrospectively analyzed 11 patients who underwent this procedure
for a primary bone tumour of the proximal humerus between 2004 and
2015. Six had Ewing’s sarcoma and five had osteosarcoma. Their mean
age at the time of surgery was five years (two to eight). The mean
follow-up was 5.2 years (1 to 12.2).Aims
Patients and Methods
Degenerative disc disease (DDD) and osteoarthritis (OA) are relatively frequent causes of disability amongst the elderly; they constitute serious socioeconomic costs and significantly impair quality of life. Previous studies to date have found that aggrecan variable number of tandem repeats (VNTR) contributes both to DDD and OA. However, current data are not consistent across studies. The purpose of this study was to evaluate systematically the relationship between aggrecan VNTR, and DDD and/or OA. This study used a highly sensitive search strategy to identify all published studies related to the relationship between aggrecan VNTR and both DDD and OA in multiple databases from January 1996 to December 2016. All identified studies were systematically evaluated using specific inclusion and exclusion criteria. Cochrane methodology was also applied to the results of this study.Objectives
Methods
A single-centre prospective randomized trial was conducted to
investigate whether a less intensive follow-up protocol would not
be inferior to a conventional follow-up protocol, in terms of overall
survival, in patients who have undergone surgery for sarcoma of
the limb. Initial short-term results were published in 2014. The primary objective was to show non-inferiority of a chest
radiograph (CXR) group compared with a CT scan group, and of a less
frequent (six-monthly) group than a more frequent (three-monthly)
group, in two-by-two comparison. The primary outcome was overall
survival and the secondary outcome was a recurrence-free survival.
Five-year survival was compared between the CXR and CT scan groups
and between the three-monthly and six-monthly groups. Of 500 patients
who were enrolled, 476 were available for follow-up. Survival analyses
were performed on a per-protocol basis (n = 412).Aims
Patients and Methods
The aim of this study was to determine if positive Waddell signs
were related to patients’ demographics or to perception of their
quality of life. This prospective cross-sectional study included 479 adult patients
with back pain from a university spine centre. Each completed SF-12
and Oswestry Disability Index (ODI) questionnaires and underwent
standard spinal examinations to elicit Waddell signs. The relationship
between Waddell signs and age, gender, ODI, Mental Component Score
(MCS), and Physical Component Score (PCS) scores was determined.Aims
Patients and Methods
We present a retrospective review of patients treated with extracorporeally
irradiated allografts for primary and secondary bone tumours with
the mid- and long-term survivorship and the functional and radiographic
outcomes. A total of 113 of 116 (97.4%) patients who were treated with
extracorporeally irradiated allografts between 1996 and 2014 were
followed up. Forms of treatment included reconstructions, prostheses
and composite reconstructions, both with and without vascularised
grafts. Survivorship was determined by the Kaplan-Meier method.
Clinical outcomes were assessed using the Musculoskeletal Tumor
Society (MSTS) scoring system, the Toronto Extremity Salvage Score
(TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes
were assessed using the International Society of Limb Salvage (ISOLS)
radiographic scoring system.Aims
Patients and Methods
The aim of this study was to identify the incidence of positive
cultures during the second stage of a two-stage revision arthroplasty
and to analyse the association between positive cultures and an
infection-free outcome. This single-centre retrospective review of prospectively collected
data included patients with a periprosthetic joint infection (PJI)
of either the hip or the knee between 2013 and 2015, who were treated
using a standardised diagnostic and therapeutic algorithm with two-stage
exchange. Failure of treatment was assessed according to a definition
determined by a Delphi-based consensus. Logistic regression analysis
was performed to assess the predictors of positive culture and risk
factors for failure. The mean follow-up was 33 months (24 to 48).Aims
Patients and Methods
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods