Advertisement for orthosearch.org.uk
Results 321 - 340 of 349
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1143 - 1144
1 Aug 2011
Khanduja V


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1313 - 1320
1 Oct 2012
Middleton RG Shabani F Uzoigwe CE AS Moqsith M Venkatesan M

Osteoporosis is common and the health and financial cost of fragility fractures is considerable. The burden of cardiovascular disease has been reduced dramatically by identifying and targeting those most at risk. A similar approach is potentially possible in the context of fragility fractures. The World Health Organization created and endorsed the use of FRAX, a fracture risk assessment tool, which uses selected risk factors to calculate a quantitative, patient-specific, ten-year risk of sustaining a fragility fracture. Treatment can thus be based on this as well as on measured bone mineral density. It may also be used to determine at-risk individuals, who should undergo bone densitometry. FRAX has been incorporated into the national osteoporosis guidelines of countries in the Americas, Europe, the Far East and Australasia. The United Kingdom National Institute for Health and Clinical Excellence also advocates its use in their guidance on the assessment of the risk of fragility fracture, and it may become an important tool to combat the health challenges posed by fragility fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 567 - 567
1 Apr 2011
Evans D


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 720 - 721
1 Jun 2011
Rangan A Maffulli N

Multicentre clinical trials in trauma care are gaining prominence as a means of generating good-quality evidence to inform and influence clinical practice. We believe multicentre trials have an important role to play in supporting evidence-based practice, and further investment in such trials is justified.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 879 - 883
1 Jun 2005
Diab M Poston JM Huber P Tencer AF

Repeated trauma to the radial head may be one of the causative factors in the genesis of osteochondritis dissecans of the capitellum. We measured the force, contact area and pressure across the radiocapitellar articulation of the elbow before and after radial shortening osteotomy in five fresh-frozen cadaver upper limbs with loads of 45, 90 and 135 N, respectively. Measurements were made on pressure-sensitive film placed in the radiocapitellar articulation with the forearm in the supinated, neutral and pronated positions before and after radial shortening. Radial shortening significantly reduced the mean force and contact area across the radiocapitellar articulation in all positions of the forearm.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 236 - 240
1 Feb 2005
Belthur MV Bradish CF Gibbons PJ

Between 1990 and 2001, 24 children aged between 15 months and 11 years presented with late orthopaedic sequelae after meningococcal septicaemia. The median time to presentation was 32 months (12 to 119) after the acute phase of the disease. The reasons for referral included angular deformity, limb-length discrepancy, joint contracture and problems with prosthetic fitting. Angular deformity with or without limb-length discrepancy was the most common presentation. Partial growth arrest was the cause of the angular deformity. Multiple growth-plate involvement occurred in 14 children. The lower limbs were affected much more often than the upper. Twenty-three children underwent operations for realignment of the mechanical axis and limb-length equalisation. In 15 patients with angular deformity around the knee the deformity recurred. As a result we recommend performing a realignment procedure with epiphysiodesis of the remaining growth plate when correcting angular deformities.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 78 - 85
1 May 2012
Entezari V Della Croce U DeAngelis JP Ramappa AJ Nazarian A Trechsel BL Dow WA Stanton SK Rosso C Müller A McKenzie B Vartanians V Cereatti A

Objectives

Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras.

Methods

In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 24 - 26
1 Apr 2014

The April 2014 Children’s orthopaedics Roundup360 looks at: urgent supracondylar fractures; rotational osteotomy for synostosis; predicting slip in paediatric forearm fractures; progressive lengthening of the digit is possible; treatment of SUFE with the Dunn osteotomy; and the best way to apply the eight-plate?.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1433 - 1439
1 Nov 2011
Dias JJ Singh HP

A displaced fracture of the scaphoid is one in which the fragments have moved from their anatomical position or there is movement between them when stressed by physiological loads. Displacement is seen in about 20% of fractures of the waist of the scaphoid, as shown by translation, a gap, angulation or rotation. A CT scan in the true longitudinal axis of the scaphoid demonstrates the shape of the bone and displacement of the fracture more accurately than do plain radiographs. Displaced fractures can be treated in a plaster cast, accepting the risk of malunion and nonunion. Surgically the displacement can be reduced, checked radiologically, arthroscopically or visually, and stabilised with headless screws or wires. However, rates of union and deformity are unknown. Mild malunion is well tolerated, but the long-term outcome of a displaced fracture that healed in malalignment has not been established.

This paper summarises aspects of the assessment, treatment and outcome of displaced fractures of the waist of the scaphoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1389 - 1394
1 Oct 2011
Soubeyrand M Ciais G Wassermann V Kalouche I Biau D Dumontier C Gagey O

Disruption of the interosseous membrane is easily missed in patients with Essex-Lopresti syndrome. None of the imaging techniques available for diagnosing disruption of the interosseous membrane are completely dependable.

We undertook an investigation to identify whether a simple intra-operative test could be used to diagnose disruption of the interosseous membrane during surgery for fracture of the radial head and to see if the test was reproducible.

We studied 20 cadaveric forearms after excision of the radial head, ten with and ten without disruption of the interosseous membrane. On each forearm, we performed the radius joystick test: moderate lateral traction was applied to the radial neck with the forearm in maximal pronation, to look for lateral displacement of the proximal radius indicating that the interosseous membrane had been disrupted. Each of six surgeons (three junior and three senior) performed the test on two consecutive days.

Intra-observer agreement was 77% (95% confidence interval (CI) 67 to 85) and interobserver agreement was 97% (95% CI 92 to 100). Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI 81 to 93), positive predictive value 90% (95% CI 83 to 94), and negative predictive value 100%).

This cadaveric study suggests that the radius joystick test may be useful for detecting disruption of the interosseous membrane in patients undergoing open surgery for fracture of the radial head and is reproducible. A confirmatory study in vivo is now required.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 984 - 989
1 Jul 2011
Park DH Bradish CF

Septicaemia resulting from meningococcal infection is a devastating illness affecting children. Those who survive can develop late orthopaedic sequelae from growth plate arrests, with resultant complex deformities. Our aim in this study was to review the case histories of a series of patients with late orthopaedic sequelae, all treated by the senior author (CFB). We also describe a treatment strategy to address the multiple deformities that may occur in these patients.

Between 1997 and 2009, ten patients (seven girls and three boys) were treated for late orthopaedic sequelae following meningococcal septicaemia. All had involvement of the lower limbs, and one also had involvement of the upper limbs. Each patient had a median of three operations (one to nine). Methods of treatment included a combination of angular deformity correction, limb lengthening and epiphysiodesis. All patients were skeletally mature at the final follow-up. One patient with bilateral below-knee amputations had satisfactory correction of her right amputation stump deformity, and has complete ablation of both her proximal tibial growth plates. In eight patients length discrepancy in the lower limb was corrected to within 1 cm, with normalisation of the mechanical axis of the lower limb.

Meningococcal septicaemia can lead to late orthopaedic sequelae due to growth plate arrests. Central growth plate arrests lead to limb-length discrepancy and the need for lengthening procedures, and peripheral growth plate arrests lead to angular deformities requiring corrective osteotomies and ablation of the damaged physis. In addition, limb amputations may be necessary and there may be altered growth of the stump requiring further surgery. Long-term follow-up of these patients is essential to recognise and treat any recurrence of deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51).

Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 903 - 906
1 Jul 2009
Trickett RW Hodgson P Forster MC Robertson A

We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement.

Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecutive patients undergoing total knee replacement by a consultant surgeon not involved with the operation, who was blinded to the size of the implant inserted. The Press Fit Condylar Sigma Knee system was used in all the patients. The size of the implant as judged by templating was then compared to that of the size used.

Good inter- and intra-observer agreement was demonstrated for both femoral and tibial templating. However, the correct size of the implant was predicted in only 48% of the femoral and 55% of the tibial components. Albeit reproducible, digital templating does not currently predict the correct size of component often enough to be of clinical benefit.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 672 - 678
1 May 2010
Robinson CM Wylie JR Ray AG Dempster NJ Olabi B Seah KTM Akhtar MA

We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed.

At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 511 - 516
1 Apr 2009
Yam A Fullilove S Sinisi M Fox M

We reviewed 42 consecutive children with a supination deformity of the forearm complicating severe birth lesions of the brachial plexus.

The overall incidence over the study period was 6.9% (48 of 696). It was absent in those in Narakas group I (27.6) and occurred in 5.7% of group II (13 of 229), 9.6% of group III (11 of 114) and 23.4% of group IV (18 of 77).

Concurrent deformities at the shoulder, elbow, wrist and hand were always present because of muscular imbalance from poor recovery of C5 and C7, inconsistent recovery of C8 and T1 and good recovery of C6. Early surgical correction improved the function of the upper limb and hand, but there was a tendency to recurrence. Pronation osteotomy placed the hand in a functional position, and increased the arc of rotation of the forearm. The supination deformity recurred in 40% (17 of 42) of those treated by pronation osteotomy alone, probably because of remodelling of the growing bone.

Children should be followed up until skeletal maturity, and the parents counselled on the likelihood of multiple operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 418 - 418
1 Mar 2006
Tucker K


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 705 - 712
1 Jun 2009
Ng CY Oliver CW

Fractures of the proximal interphalangeal joint include a wide spectrum of injuries, from stable avulsion fractures to complex fracture-dislocations. Stability of the joint is paramount in determining the appropriate treatment, which should aim to facilitate early mobilisation and restoration of function.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1205 - 1209
1 Sep 2008
Beeres FJP Rhemrev SJ den Hollander P Kingma LM Meylaerts SAG le Cessie S Bartlema KA Hamming JF Hogervorst M

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, clinical and/or radiological evidence of a fracture.

MRI revealed 16 scaphoid and 24 other fractures. Bone scintigraphy showed 28 scaphoid and 40 other fractures. According to the reference standard there were 20 scaphoid fractures. MRI was falsely negative for scaphoid fracture in four patients and bone scintigraphy falsely positive in eight. MRI had a sensitivity of 80% and a specificity of 100%. Bone scintigraphy had a sensitivity of 100% and a specificity of 90%.

This study did not confirm that early, short-sequence MRI was superior to bone scintigraphy for the diagnosis of a suspected scaphoid fracture. Bone scintigraphy remains a highly sensitive and reasonably specific investigation for the diagnosis of an occult scaphoid fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 250 - 257
1 Feb 2010
Ferguson TA Patel R Bhandari M Matta JM

Using a prospective database of 1309 displaced acetabular fractures gathered between 1980 and 2007, we calculated the annual mean age and annual incidence of elderly patients > 60 years of age presenting with these injuries. We compared the clinical details and patterns of fracture between patients > 60 years of age (study group) with those < 60 years (control group). We performed a detailed evaluation of the radiographs of the older group to determine the incidence of radiological characteristics which have been previously described as being associated with a poor patient outcome.

In all, 235 patients were > 60 years of age and the remaining 1074 were < 60 years. The incidence of elderly patients with acetabular fractures increased by 2.4-fold between the first half of the study period and the second half (10% (62) vs 24% (174), p < 0.001). Fractures characterised by displacement of the anterior column were significantly more common in the elderly compared with the younger patients (64% (150) vs 43% (462), respectively, p < 0.001). Common radiological features of the fractures in the study group included a separate quadrilateral-plate component (50.8% (58)) and roof impaction (40% (46)) in the anterior fractures, and comminution (44% (30)) and marginal impaction (38% (26)) in posterior-wall fractures.

The proportion of elderly patients presenting with acetabular fractures increased during the 27-year period. The older patients had a different distribution of fracture pattern than the younger patients, and often had radiological features which have been shown in other studies to be predictive of a poor outcome.