The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1124 - 1129
1 Aug 2014
Segaren N Abdul-Jabar HB Hashemi-Nejad A

Proximal femoral varus osteotomy improves the biomechanics of the hip and can stimulate normal acetabular development in a dysplastic hip. Medial closing wedge osteotomy remains the most popular technique, but is associated with shortening of the ipsilateral femur.

We produced a trigonometric formula which may be used pre-operatively to predict the resultant leg length discrepancy (LLD). We retrospectively examined the influence of the choice of angle in a closing wedge femoral osteotomy on LLD in 120 patients (135 osteotomies, 53% male, mean age six years, (3 to 21), 96% caucasian) over a 15-year period (1998 to 2013). A total of 16 of these patients were excluded due to under or over varus correction. The patients were divided into three age groups: paediatric (< 10 years), adolescent (10 to 16 years) and adult (> 16 years). When using the same saw blades as in this series, the results indicated that for each 10° of angle of resection the resultant LLD equates approximately to multiples of 4 mm, 8 mm and 12 mm in the three age groups, respectively.

Statistical testing of the 59 patients who had a complete set of pre- and post-operative standing long leg radiographs, revealed a Pearson’s correlation coefficient for predicted versus radiologically observed shortening when using a wedge of either 10° or 20° of 0.93 (p <  0.001). The 95% limits of agreement from the Bland–Altman analysis for this subgroup were –3.5 mm to +3.3 mm. It has been accepted that a 10 mm discrepancy is clinically acceptable.

This study identified a geometric model that provided satisfactory accuracy when using specific saw blades of known thicknesses for this formula to be used in clinical practice.

Cite this article: Bone Joint J 2014;96-B:1124–9


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 778 - 782
1 Jun 2014
Tinney A Khot A Eizenberg N Wolfe R Graham HK

Lengthening of the conjoined tendon of the gastrocnemius aponeurosis and soleus fascia is frequently used in the treatment of equinus deformities in children and adults. The Vulpius procedure as described in most orthopaedic texts is a division of the conjoined tendon in the shape of an inverted V. However, transverse division was also described by Vulpius and Stoffel, and has been reported in some clinical studies.

We studied the anatomy and biomechanics of transverse division of the conjoined tendon in 12 human cadavers (24 legs). Transverse division of the conjoined tendon resulted in predictable, controlled lengthening of the gastrocsoleus muscle-tendon unit. The lengthening achieved was dependent both on the level of the cut in the conjoined tendon and division of the midline raphé. Division at a proximal level resulted in a mean lengthening of 15.2 mm (sd 2.0, (12 to 19), which increased to 17.1 mm (sd 1.8, (14 to 20) after division of the midline raphé. Division at a distal level resulted in a mean lengthening of 21.0 mm (sd 2.0, (18 to 25), which increased to 26.4 mm (sd 1.4, (24 to 29) after division of the raphé. These differences were significant (p < 0.001).

Cite this article: Bone Joint J 2014; 96-B:778–82.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 8 - 9
1 Apr 2014

The April 2014 Hip & Pelvis Roundup360 looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 99 - 103
1 Jun 2012
Mason LW Tanaka H

Introduction

The aetiology of hallux valgus is almost certainly multifactoral. The biomechanics of the first ray is a common factor to most. There is very little literature examining the anatomy of the proximal metatarsal articular surface and its relationship to hallux valgus deformity.

Methods

We examined 42 feet from 23 specimens in this anatomical dissection study.


Bone & Joint Research
Vol. 3, Issue 10 | Pages 289 - 296
1 Oct 2014
van IJsseldijk EA Harman MK Luetzner J Valstar ER Stoel BC Nelissen RGHH Kaptein BL

Introduction

Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts.

Method

Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 9 - 13
1 Jun 2014
Waterson HB Philips JRA Mandalia VI Toms AD

Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA.

This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 281 - 286
1 Feb 2012
Chana R Esposito C Campbell PA Walter WK Walter WL

We report a case of a male patient presenting with bilateral painful but apparently well-positioned and -fixed large-diameter metal-on-metal hip replacements four years post-operatively. Multiple imaging modes revealed a thick-walled, cystic expansile mass in communication with the hip joint (a pseudotumour). Implant retrieval analysis and tissue culture eliminated high bearing wear or infection as causes for the soft-tissue reaction, but noted marked corrosion of the modular neck taper adaptor and corrosion products in the tissues. Therefore, we believe corrosion products from the taper caused by mismatch of the implant components led to pseudotumour formation requiring revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1192 - 1196
1 Sep 2006
Jeong S Song H Keny SM Telang SS Suh S Hong S

We carried out an MRI study of the lumbar spine in 15 patients with achondroplasia to evaluate the degree of stenosis of the canal. They were divided into asymptomatic and symptomatic groups. We measured the sagittal canal diameter, the sagittal cord diameter, the interpedicular distance at the mid-pedicle level and the cross-sectional area of the canal and spinal cord at mid-body and mid-disc levels.

The MRI findings showed that in achondroplasia there was a significant difference between the groups in the cross-sectional area of the body canal at the upper lumbar levels. Patients with a narrower canal are more likely to develop symptoms of spinal stenosis than others.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 639 - 645
1 May 2010
Kim Y Choi Y Kim J

We undertook a study in which 138 female patients with a mean age of 71.2 years (51 to 82) received a standard NexGen CR-flex prosthesis in one knee and a gender-specific NexGen CR-flex prosthesis in the other. The mean follow-up period was 3.25 years (3.1 to 3.5). The aspect ratios of the standard and gender-specific prostheses were compared with that of the distal femur.

The mean post-operative Knee Society knee scores were 94 (70 to 100) and 93 (70 to 100) points and the function scores were 83 (60 to 100) and 84 (60 to 100) points for the standard implants and the gender-specific designs, respectively. The mean post-operative Western Ontario and McMaster Universities score was 26.4 points (0 to 76). Patient satisfaction, the radiological results and the complication rates were similar in the two groups. In those with a standard prosthesis, the femoral component was closely matched in 80 knees (58.0%), overhung in 14 (10.1%) and undercovered the bone in 44 (31.9%). In those with a gender-specific prosthesis, it was closely matched in 15 knees (10.9%) and undercovered the bone in 123 (89.1%).

Since we found no significant differences between the two groups with regard to the clinical and radiological results, patient satisfaction or complication rate, the goal of the design of the gender-specific CR-flex prosthesis to improve the outcome was not achieved in our patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 215 - 221
1 Feb 2012
Dawson J Boller I Doll H Lavis G Sharp R Cooke P Jenkinson C

The responsiveness of the Manchester–Oxford Foot Questionnaire (MOXFQ) was compared with foot/ankle-specific and generic outcome measures used to assess all surgery of the foot and ankle. We recruited 671 consecutive adult patients awaiting foot or ankle surgery, of whom 427 (63.6%) were female, with a mean age of 52.8 years (18 to 89). They independently completed the MOXFQ, Short-Form 36 (SF-36) and EuroQol (EQ-5D) questionnaires pre-operatively and at a mean of nine months (3.8 to 14.4) post-operatively. Foot/ankle surgeons assessed American Orthopaedic Foot and Ankle Society (AOFAS) scores corresponding to four foot/ankle regions. A transition item measured perceived changes in foot/ankle problems post-surgery. Of 628 eligible patients proceeding to surgery, 491 (78%) completed questionnaires and 262 (42%) received clinical assessments both pre- and post-operatively. The regions receiving surgery were: multiple/whole foot in eight (1.3%), ankle/hindfoot in 292 (46.5%), mid-foot in 21 (3.3%), hallux in 196 (31.2%), and lesser toes in 111 (17.7%). Foot/ankle-specific MOXFQ, AOFAS and EQ-5D domains produced larger effect sizes (> 0.8) than any SF-36 domains, suggesting superior responsiveness. In analyses that anchored change in scores and effect sizes to patients’ responses to a transition item about their foot/ankle problems, the MOXFQ performed well. The SF-36 and EQ-5D performed poorly. Similar analyses, conducted within foot-region based sub-groups of patients, found that the responsiveness of the MOXFQ was good compared with the AOFAS.

This evidence supports the MOXFQ’s suitability for assessing all foot and ankle surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 454 - 460
1 Mar 2010
Baleani M Bialoblocka-Juszczyk E Engels GE Viceconti M

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement.

Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue tests, and were examined for porosity.

Pre-heating the stem alone significantly increased the mean temperature values measured within the mantle (+14.2°C) (p < 0.001) and reduced the mean curing time (−1.5 min) (p < 0.001). The addition of vacuum mixing modulated the mean rise in the temperature of polymerisation to 11°C and reduced the mean duration of the process by one minute and 50 seconds (p = 0.01 and p < 0.001, respectively). In all cases, the maximum temperature values measured in the mould simulating the femur were < 50°C. The mixing technique and pre-heating the stem slightly increased the static mechanical strength of bone cement. However, the fatigue life of the cement was improved by both vacuum mixing and pre-heating the stem, but was most marked (+ 280°C) when these methods were combined.

Pre-heating the stem appears to be an effective way of improving the quality of the cement mantle, which might enhance the long-term performance of bone cement, especially when combined with vacuum mixing.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 459 - 462
1 Apr 2009
Heinert G Hendricks J Loeffler MD

Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from 22 patients to calculate the magnification using both methods. The accuracy of each method was ascertained by measuring the size of the head of the implant projected on to the radiographs and comparing the result with the known size recorded in the medical records.

The accuracy was found to be similar with a mean absolute measurement error of 2.6% (sd 1.4; 0.0% to 5.2%) for the radiological marker and 2.8% (sd 2.2; 0.4% to 10.1%) for the distance method (p = 0.75). The mean radiation dose for templating radiographs (pelvis and lateral of the hip) was similar when taken using a radiological marker (328 mSv sd 142) (n = 51) or using the distance measurement method (324 mSv sd 39) (n = 39) (p = 0.90).

We conclude that the distance measuring method is as accurate as the radiological marker method, but may avoid some of the disadvantages such as misplacement of the marker or placement outside the radiological field. It may also be more acceptable to the patient and radiographer.


Bone & Joint Research
Vol. 1, Issue 4 | Pages 56 - 63
1 Apr 2012
Langton DJ Sidaginamale R Lord JK Nargol AVF Joyce TJ

Objectives

An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer.

Methods

Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular bearing surfaces and also the surfaces of the taper junctions. The relationship between taper wear rates and a number of variables, including bearing diameter and orientation of the acetabular component, was investigated.


Bone & Joint Research
Vol. 3, Issue 5 | Pages 161 - 168
1 May 2014
Mundi R Chaudhry H Mundi S Godin K Bhandari M

High-quality randomised controlled trials (RCTs) evaluating surgical therapies are fundamental to the delivery of evidence-based orthopaedics. Orthopaedic clinical trials have unique challenges; however, when these challenges are overcome, evidence from trials can be definitive in its impact on surgical practice. In this review, we highlight several issues that pose potential challenges to orthopaedic investigators aiming to perform surgical randomised controlled trials. We begin with a discussion on trial design issues, including the ethics of sham surgery, the importance of sample size, the need for patient-important outcomes, and overcoming expertise bias. We then explore features surrounding the execution of surgical randomised trials, including ethics review boards, the importance of organisational frameworks, and obtaining adequate funding.

Cite this article: Bone Joint Res 2014;3:161–8.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs.

Cite this article: Bone Joint J 2013;95-B:1458–63.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 130 - 138
1 Apr 2014
Shapiro F Connolly S Zurakowski D Flynn E Jaramillo D

Objectives

An experimental piglet model induces avascular necrosis (AVN) and deformation of the femoral head but its secondary effects on the developing acetabulum have not been studied. The aim of this study was to assess the development of secondary acetabular deformation following femoral head ischemia.

Methods

Intracapsular circumferential ligation at the base of the femoral neck and sectioning of the ligamentum teres were performed in three week old piglets. MRI was then used for qualitative and quantitative studies of the acetabula in operated and non-operated hips in eight piglets from 48 hours to eight weeks post-surgery. Specimen photographs and histological sections of the acetabula were done at the end of the study.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 60 - 68
1 Mar 2014
Langton DJ Sidaginamale RP Holland JP Deehan D Joyce TJ Nargol AVF Meek RD Lord JK

Objectives

Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena.

Methods

We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1626 - 1631
1 Dec 2013
van der Weegen W Brakel K Horn RJ Hoekstra HJ Sijbesma T Pilot P Nelissen RGHH

The aim of this study was to establish the natural course of unrevised asymptomatic pseudotumours after metal-on-metal (MoM) hip resurfacing during a six- to 12-month follow-up period. We used repeated metal artefact reduction sequence (MARS)-magnetic resonance imaging (MRI), serum metal ion analysis and clinical examination to study 14 unrevised hips (mean patient age 52.7 years, 46 to 68, 5 female, 7 male) with a pseudotumour and 23 hips (mean patient age 52.8 years, 38 to 69, 7 female, 16 male) without a pseudotumour. The mean post-operative time to the first MARS-MRI scan was 4.3 years (2.2 to 8.3), and mean time between the first and second MARS-MRI scan was eight months (6 to 12). At the second MRI scan, the grade of severity of the pseudotumour had not changed in 35 hips. One new pseudotumour (Anderson C2 score, moderate) was observed, and one pseudotumour was downgraded from C2 (moderate) to C1 (mild). In general, the characteristics of the pseudotumours hardly changed.

Repeated MARS-MRI scans within one year in patients with asymptomatic pseudotumours after MoM hip resurfacing showed little or no variation. In 23 patients without pseudotumour, one new asymptomatic pseudotumour was detected.

This is the first longitudinal study on the natural history of pseudotumours using MARS-MRI scans in hip resurfacing, and mirrors recent results for 28 mm diameter MoM total hip replacement.

Cite this article: Bone Joint J 2013;95-B:1626–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 427 - 434
1 Apr 2011
Griffin M Iqbal SA Bayat A

Failure of bone repair is a challenging problem in the management of fractures. There is a limited supply of autologous bone grafts for treating nonunions, with associated morbidity after harvesting. There is need for a better source of cells for repair. Mesenchymal stem cells (MSCs) hold promise for healing of bone because of their capacity to differentiate into osteoblasts and their availability from a wide variety of sources. Our review aims to evaluate the available clinical evidence and recent progress in strategies which attempt to use autologous and heterologous MSCs in clinical practice, including genetically-modified MSCs and those grown on scaffolds. We have compared various procedures for isolating and expanding a sufficient number of MSCs for use in a clinical setting.

There are now a number of clinical studies which have shown that implantation of MSCs is an effective, safe and durable method for aiding the repair and regeneration of bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1332 - 1337
1 Oct 2010
Leung KS Tang N Cheung LWH Ng E

Fluoronavigation is an image-guided technology which uses intra-operative fluoroscopic images taken under a real-time tracking system and registration to guide surgical procedures. With the skeleton and the instrument registered, guidance under an optical tracking system is possible, allowing fixation of the fracture and insertion of an implant. This technology helps to minimise exposure to x-rays, providing multiplanar views for monitoring and accurate positioning of implants. It allows real-time interactive quantitative data for decision-making and expands the application of minimally invasive surgery. In orthopaedic trauma its use can be further enhanced by combining newer imaging technologies such as intra-operative three-dimensional fluoroscopy and optical image guidance, new advances in software for fracture reduction, and new tracking mechanisms using electromagnetic technology. The major obstacles for general and wider applications are the inability to track individual fracture fragments, no navigated real-time fracture reduction, and the lack of an objective assessment method for cost-effectiveness.

We believe that its application will go beyond the operating theatre and cover all aspects of patient management, from pre-operative planning to intra-operative guidance and postoperative rehabilitation.