Advertisement for orthosearch.org.uk
Results 301 - 320 of 4287
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 177 - 184
1 Feb 2015
Felden A Vaz G Kreps S Anract P Hamadouche M Biau DJ

Conventional cemented acetabular components are reported to have a high rate of failure when implanted into previously irradiated bone. We recommend the use of a cemented reconstruction with the addition of an acetabular reinforcement cross to improve fixation. We reviewed a cohort of 45 patients (49 hips) who had undergone irradiation of the pelvis and a cemented total hip arthroplasty (THA) with an acetabular reinforcement cross. All hips had received a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3: 45 to 60; mean: 49.57, 32 to 72). . The mean follow-up after THA was 51 months (17 to 137). The cumulative probability of revision of the acetabular component for a mechanical reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60 months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One hip was revised for mechanical failure and three for infection. Cemented acetabular components with a reinforcement cross provide good medium-term fixation after pelvic irradiation. These patients are at a higher risk of developing infection of their THA. . Cite this article: Bone Joint J 2015;97-B:177–84


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 387 - 391
1 Apr 2002
Sandén B Olerud C Petrén-Mallmin M Larsson S

We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws. At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 ± 36 Ncm for the uncoated group, 447 ± 114 Ncm for the partly-coated group and 574 ± 52 Ncm for the fully-coated group. There were significant differences between all three groups (p < 0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p < 0.001). HA coating of pedicle screws resulted in improved fixation with reduced risk of loosening of the screws


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 87 - 92
1 Nov 2014
Kwong LM Nielsen ESN Ruiz DR Hsu AH Dines MD Mellano CM

A retrospective review was performed of patients undergoing primary cementless total knee replacement (TKR) using porous tantalum performed by a group of surgical trainees. Clinical and radiological follow-up involved 79 females and 26 males encompassing 115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up was 7 years (2 to 11). Tibial and patellar components were porous tantalum monoblock implants, and femoral components were posterior stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological assessments were made for implant positioning, alignment, radiolucencies, lysis, and loosening. There was 95.7% survival of implants. There was no radiological evidence of loosening and no osteolysis found. No revisions were performed for aseptic loosening. Average tibial component alignment was 1.4° of varus (4°of valgus to 9° varus), and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient satisfaction with improvement in pain was 91%. Cementless TKR incorporating porous tantalum yielded good clinical and radiological outcomes at a mean of follow-up of seven-years.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):87–92.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 4 | Pages 634 - 660
1 Nov 1965
Burwell HN Charnley AD

1. This paper presents a series of 135 patients with displaced ankle fractures treated by rigid internal fixation followed by early joint exercises in bed until movements were restored and followed then by full weight bearing in a plaster. 2. The advantages obtained are as follows: A high standard of reduction can be achieved and maintained. The joint movements are established before organisation of the traumatic exudate. Weight bearing in a plaster reduces the degree of disability and prevents osteoporosis. Further remedial treatment after removal of the plaster is usually unnecessary. 3. All but five of the fractures (3·7 per cent) could be classified in the manner described by Lauge-Hansen. 4. This classification is the most satisfactory of those available and is recommended for general use. 5. Anatomical reduction was obtained in 102 patients (77 per cent), with good objective clinical results in 108 patients (82 per cent). 6. The quality of the clinical result depends mostly on the accuracy of the reduction, to a lesser extent on the degree of initial displacement, and least on the type of fracture. 7. It is considered that the traditional concept of diastasis requires modification; it is felt that the term lateral ankle instability, which includes low fracture of the fibula (intraosseous diastasis) is preferable. 8. Internal fixation of the syndesmosis is to be avoided except in rare instances. 9. The incidence of arthritis is shown to depend mostly upon the accuracy of reduction; the initial degree of displacement is also of importance


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 279 - 280
1 Mar 2003
Solan MC Rees R Molloy S Proctor MT

We describe a patient who sustained a displaced isolated intra-articular fracture of the distal ulna, causing limitation of rotation of the forearm. The extent of displacement of the fracture which was not evident on plain radiographs was revealed by CT. The fracture was reduced and internally fixed using a standard technique applicable to the fixation of fractures of the radial head. Full movement was restored. An isolated injury to the distal ulna is rare and requires careful clinical and radiological assessment


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 787 - 792
1 Jul 2019
Goto K Kuroda Y Kawai T Kawanabe K Matsuda S

Aims

In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC.

Patients and Methods

A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 280 - 282
1 Mar 1990
Curtis M

Cadaveric experiments in 10 knees were used to study the strength of two methods of internal fixation for a fractured patella. A modified AO tension band technique was compared with the combination of cerclage wiring and a tension band used at Pyrford. The repairs were stressed to failure; the combination of cerclage and tension band wiring proved to be significantly stronger and is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 357 - 361
1 Aug 1981
Sikorski J Barrington R

A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and internal fixation using Garden screws; Thompson hemiarthroplasty through a posterior (Moore) approach; and Thompson hemiarthroplasty through an anterolateral (McKee) approach. There is no significant difference in the mortality of the internal fixation and posterior arthroplasty groups. Both groups showed a significantly higher mortality than patients operated on through the anterior approach. The technical results of operation were worse in the internally fixed group, with only 40 per cent being satisfactory. Mobilisation was best achieved after the posterior approach. It is concluded that Thompson hemiarthroplasty, using an anterolateral approach, is the safest operation in this group of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 124 - 127
1 Jan 1984
Leyshon A Ireland J Trickey E

A simple technique for screw fixation of the carpal scaphoid in cases of delayed union and non-union is described. The results obtained in 32 patients treated by this method are reported. The average follow-up was three years ranging from 10 months to 12 years. Union was obtained in 28 patients. The causes of failure to unite are discussed and the advantages of the reported method over other techniques such as bone grafting are stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 801 - 804
1 Sep 1990
Court-Brown C Wheelwright E Christie J McQueen M

An analysis of 51 type III open tibial fractures treated by external skeletal fixation is presented. The fractures are subdivided according to the classification of Gustilo, Mendoza and Williams (1984) into types IIIa, IIIb and IIIc. The different prognoses of these fracture subtypes is examined. The use of the Hoffmann and Hughes external fixators in the management of type III open tibial fractures is presented and it is suggested that the prognosis is independent of the type of fixator used


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 65 - 67
1 Jan 1991
Rosson J Petley G Shearer

We used single-photon absorptiometry to assess the forearm bones after the removal of internal fixation plates in 14 patients. We found convincing evidence of cortical atrophy in only one patient, in whom the plates had been removed prematurely after only 16 months. It is suggested that such plates should be retained for at least 21 months, to allow bone density to return to its prefracture level. The recommendations of the AO/ASIF group are supported


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 54 - 60
1 Feb 1970
McNeur JC

1. The use of metallic internal fixation in the primary treatment of 176 open skeletal injuries is discussed and the results presented. 2. The use of metal (stainless steel) in this type of injury is shown not to have any harmful effects. it can be used with safety and benefit in the primary treatment of open skeletal trauma, especially in the multiple and complicated injuries of war and motor vehicle accidents. 3. The place of antibiotics is discussed and adequate treatment of the soft-tissue wound is stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1487 - 1494
1 Nov 2008
Zlowodzki M Brink O Switzer J Wingerter S Woodall J Petrisor BA Kregor PJ Bruinsma DR Bhandari M

We have studied the effect of shortening of the femoral neck and varus collapse on the functional capacity and quality of life of patients who had undergone fixation of an isolated intracapsular fracture of the hip with cancellous screws. After screening 660 patients at four university medical centres, 70 patients with a mean age of 71 years (20 to 90) met the inclusion criteria. Overall, 66% (46 of 70) of the fractures healed with > 5 mm of shortening and 39% (27 of 70) with > 5° of varus. Patients with severe shortening of the femoral neck had significantly lower short form-36 questionnaire (SF-36) physical functioning scores (no/mild (< 5 mm) vs severe shortening (> 10 mm); 74 vs 42 points, p < 0.001). A similar effect was noted with moderate shortening, suggesting a gradient effect (no/mild (< 5 mm) vs moderate shortening (5 to 10 mm); 74 vs 53 points, p = 0.011). Varus collapse correlated moderately with the occurrence of shortening (r = 0.66, p < 0.001). Shortening also resulted in a significantly lower EuroQol questionnaire (EQ5D) index scores (p = 0.05). In a regression analysis shortening of the femoral neck was the only significant variable predictive of a low SF-36 physical functioning score (p < 0.001)


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 233 - 241
1 Feb 2018
Ohmori T Kitamura T Nishida T Matsumoto T Tokioka T

Aim

There is not adequate evidence to establish whether external fixation (EF) of pelvic fractures leads to a reduced mortality. We used the Japan Trauma Data Bank database to identify isolated unstable pelvic ring fractures to exclude the possibility of blood loss from other injuries, and analyzed the effectiveness of EF on mortality in this group of patients.

Patients and Methods

This was a registry-based comparison of 1163 patients who had been treated for an isolated unstable pelvic ring fracture with (386 patients) or without (777 patients) EF. An isolated pelvic ring fracture was defined by an Abbreviated Injury Score (AIS) for other injuries of < 3. An unstable pelvic ring fracture was defined as having an AIS ≥ 4. The primary outcome of this study was mortality. A subgroup analysis was carried out for patients who required blood transfusion within 24 hours of arrival in the Emergency Department and those who had massive blood loss (AIS code: 852610.5). Propensity-score matching was used to identify a cohort like the EF and non-EF groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 831 - 833
1 Sep 1994
Jacobsson S Djerf K Ivarsson I Wahlstrom O

We studied the effect of non-steroidal anti-inflammatory drugs on the fixation of hydroxyapatite-coated implants. Cylindrical plugs of pure titanium, coated with hydroxyapatite (HA), were inserted into both femora of 10 adult rabbits, 5 of which received 7 daily doses of 30 mg diclofenac. Three weeks after implantation the interface strengths were measured by the pull-out test. The mean peak force for the diclofenac-treated group was 290 +/- 57 N compared with 369 +/- 37 N for the control group (p < 0.025). We conclude that the inhibitory effect of diclofenac on bone repair is not neutralised by HA-coating of an implant


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1035 - 1040
1 Sep 2004
Upadhyay A Jain P Mishra P Maini L Gautum VK Dhaon BK

We have compared the results and complications after closed and open reduction with internal fixation in young adults with displaced intracapsular fractures (Garden grades III and IV) of the neck of the femur. We also studied the risk factors which influenced nonunion and the development of avascular necrosis (AVN). A total of 102 patients aged between 15 and 50 years was randomised to receive either closed or open reduction. Both groups were compared for age, gender, time to surgery and posterior comminution as well as for union and complications. Using univariate and multivariate analysis the factors influencing nonunion and AVN were assessed. Of the 102 patients, 92 were available for review. There was no significant difference between the groups in terms of union (p = 0.93) and AVN at two years (p = 0.85). Posterior comminution, poor reduction and improper placement of the screws were the major factors contributing to nonunion. The overall incidence of AVN was 16.3% (15 of 92 patients) and it was not influenced by these factors. A delay of more than 48 hours before surgery did not influence the rate of union or the development of AVN when compared with operation within 48 hours of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee. In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1093 - 1095
1 Aug 2006
Hagino T Ochiai S Tonotsuka H Tokai M Senga S Hamada Y

Fracture of the atlas is rare in children. We report a case of fracture of the atlas through a synchondrosis of the anterior arch complicated by atlantoaxial rotatory fixation in a four-year-old girl