Conventional cemented acetabular components are
reported to have a high rate of failure when implanted into previously
irradiated bone. We recommend the use of a cemented reconstruction
with the addition of an acetabular reinforcement cross to improve
fixation. We reviewed a cohort of 45 patients (49 hips) who had undergone
irradiation of the pelvis and a cemented total hip arthroplasty
(THA) with an acetabular reinforcement cross. All hips had received
a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour
or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3:
45 to 60; mean: 49.57, 32 to 72). . The mean follow-up after THA was 51 months (17 to 137). The cumulative
probability of revision of the acetabular component for a mechanical
reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60
months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One
hip was revised for mechanical failure and three for infection. Cemented acetabular components with a reinforcement cross provide
good medium-term
We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws. At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 ± 36 Ncm for the uncoated group, 447 ± 114 Ncm for the partly-coated group and 574 ± 52 Ncm for the fully-coated group. There were significant differences between all three groups (p <
0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p <
0.001). HA coating of pedicle screws resulted in improved
A retrospective review was performed of patients
undergoing primary cementless total knee replacement (TKR) using
porous tantalum performed by a group of surgical trainees. Clinical
and radiological follow-up involved 79 females and 26 males encompassing
115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up
was 7 years (2 to 11). Tibial and patellar components were porous
tantalum monoblock implants, and femoral components were posterior
stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological
assessments were made for implant positioning, alignment, radiolucencies,
lysis, and loosening. There was 95.7% survival of implants. There
was no radiological evidence of loosening and no osteolysis found.
No revisions were performed for aseptic loosening. Average tibial
component alignment was 1.4° of varus (4°of valgus to 9° varus),
and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean
femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral
alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar
tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient
satisfaction with improvement in pain was 91%. Cementless TKR incorporating
porous tantalum yielded good clinical and radiological outcomes
at a mean of follow-up of seven-years. Cite this article:
1. This paper presents a series of 135 patients with displaced ankle fractures treated by rigid internal
We describe a patient who sustained a displaced isolated intra-articular fracture of the distal ulna, causing limitation of rotation of the forearm. The extent of displacement of the fracture which was not evident on plain radiographs was revealed by CT. The fracture was reduced and internally fixed using a standard technique applicable to the
In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC. A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method.Aims
Patients and Methods
We have prospectively compared the
In patients with osteoporosis there is always
a strong possibility that pedicle screws will loosen. This makes
it difficult to select the appropriate osteoporotic patient for
a spinal fusion. The purpose of this study was to determine the
correlation between bone mineral density (BMD) and the magnitude
of torque required to insert a pedicle screw. To accomplish this,
181 patients with degenerative disease of the lumbar spine were
studied prospectively. Each underwent dual-energy x-ray absorptiometry
(DEXA) and intra-operative measurement of the torque required to
insert each pedicle screw. The levels of torque generated in patients
with osteoporosis and osteopenia were significantly lower than those
achieved in normal patients. Positive correlations were observed between
BMD and T-value at the instrumented lumbar vertebrae, mean BMD and
mean T-value of the lumbar vertebrae, and mean BMD and mean T-value
of the proximal femur. The predictive torque (Nm) generated during pedicle
screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar
vertebrae)], as measured by linear regression analysis. The positive
correlation between BMD and the maximum torque required to insert
a pedicle screw suggests that pre-operative assessment of BMD may
be useful in determining the ultimate strength of
Cadaveric experiments in 10 knees were used to study the strength of two methods of internal
A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and internal
A simple technique for screw
An analysis of 51 type III open tibial fractures treated by external skeletal
We used single-photon absorptiometry to assess the forearm bones after the removal of internal
1. The use of metallic internal
We have studied the effect of shortening of the femoral neck and varus collapse on the functional capacity and quality of life of patients who had undergone
There is not adequate evidence to establish whether external
fixation (EF) of pelvic fractures leads to a reduced mortality.
We used the Japan Trauma Data Bank database to identify isolated
unstable pelvic ring fractures to exclude the possibility of blood
loss from other injuries, and analyzed the effectiveness of EF on
mortality in this group of patients. This was a registry-based comparison of 1163 patients who had
been treated for an isolated unstable pelvic ring fracture with
(386 patients) or without (777 patients) EF. An isolated pelvic
ring fracture was defined by an Abbreviated Injury Score (AIS) for
other injuries of <
3. An unstable pelvic ring fracture was defined
as having an AIS ≥ 4. The primary outcome of this study was mortality.
A subgroup analysis was carried out for patients who required blood
transfusion within 24 hours of arrival in the Emergency Department
and those who had massive blood loss (AIS code: 852610.5). Propensity-score
matching was used to identify a cohort like the EF and non-EF groups.Aim
Patients and Methods
We studied the effect of non-steroidal anti-inflammatory drugs on the
We have compared the results and complications after closed and open reduction with internal
This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve
Fracture of the atlas is rare in children. We report a case of fracture of the atlas through a synchondrosis of the anterior arch complicated by atlantoaxial rotatory