Advertisement for orthosearch.org.uk
Results 301 - 320 of 1666
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 844 - 851
1 Jul 2022
Rogmark C Nåtman J Jobory A Hailer NP Cnudde P

Aims

Patients with femoral neck fractures (FNFs) treated with total hip arthroplasty (THA) have an almost ten-fold increased risk of dislocation compared to patients undergoing elective THA. The surgical approach influences the risk of dislocation. To date, the influence of differing head sizes and dual-mobility components (DMCs) on the risk of dislocation has not been well studied.

Methods

In an observational cohort study on 8,031 FNF patients with THA between January 2005 and December 2014, Swedish Arthroplasty Register data were linked with the National Patient Register, recording the total dislocation rates at one year and revision rates at three years after surgery. The cumulative incidence of events was estimated using the Kaplan-Meier method. Cox multivariable regression models were fitted to calculate adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) for the risk of dislocation, revision, or mortality, stratified by surgical approach.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


Bone & Joint Open
Vol. 3, Issue 7 | Pages 515 - 528
1 Jul 2022
van der Heijden L Bindt S Scorianz M Ng C Gibbons MCLH van de Sande MAJ Campanacci DA

Aims

Giant cell tumour of bone (GCTB) treatment changed since the introduction of denosumab from purely surgical towards a multidisciplinary approach, with recent concerns of higher recurrence rates after denosumab. We evaluated oncological, surgical, and functional outcomes for distal radius GCTB, with a critically appraised systematic literature review.

Methods

We included 76 patients with distal radius GCTB in three sarcoma centres (1990 to 2019). Median follow-up was 8.8 years (2 to 23). Seven patients underwent curettage, 38 curettage with adjuvants, and 31 resection; 20 had denosumab.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1223 - 1231
1 Sep 2011
Babazadeh S Dowsey MM Swan JD Stoney JD Choong PFM

The role of computer-assisted surgery in maintaining the level of the joint in primary knee joint replacement (TKR) has not been well defined. We undertook a blinded randomised controlled trial comparing joint-line maintenance, functional outcomes, and quality-of-life outcomes between patients undergoing computer-assisted and conventional TKR. A total of 115 patients were randomised (computer-assisted, n = 55; conventional, n = 60). Two years post-operatively no significant correlation was found between computer-assisted and conventional surgery in terms of maintaining the joint line. Those TKRs where the joint line was depressed post-operatively improved the least in terms of functional scores. No difference was detected in terms of quality-of-life outcomes. Change in joint line was found to be related to change in alignment. Change in alignment significantly affects change in joint line and functional scores


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages


Bone & Joint Open
Vol. 3, Issue 8 | Pages 648 - 655
1 Aug 2022
Yeung CM Bhashyam AR Groot OQ Merchan N Newman ET Raskin KA Lozano-Calderón SA

Aims

Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture.

Methods

This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims

This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation.

Methods

This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims

Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error.

Methods

A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Δsacral slope(SS)stand-sit > 30°), or stiff (SSstand-sit < 10°) spinopelvic mobility contributed to increased error rates.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 395 - 401
1 Mar 2016
Helenius I Keskinen H Syvänen J Lukkarinen H Mattila M Välipakka J Pajulo O

Aims. In a multicentre, randomised study of adolescents undergoing posterior spinal fusion for idiopathic scoliosis, we investigated the effect of adding gelatine matrix with human thrombin to the standard surgical methods of controlling blood loss. Patients and Methods. Patients in the intervention group (n = 30) were randomised to receive a minimum of two and a maximum of four units of gelatine matrix with thrombin in addition to conventional surgical methods of achieving haemostasis. Only conventional surgical methods were used in the control group (n = 30). We measured the intra-operative and total blood loss (intra-operative blood loss plus post-operative drain output). Results. Each additional hour of operating time increased the intra-operative blood loss by 356.9 ml (p < 0.001) and the total blood loss by 430.5 ml (p < 0.001). Multiple linear regression analysis showed that the intervention significantly decreased the intra-operative (-171 ml, p = 0.025) and total blood loss (-177 ml, p = 0.027). The decrease in haemoglobin concentration from the day before the operation to the second post-operative day was significantly smaller in the intervention group (-6 g/l, p = 0.013) than in the control group. . Conclusion. The addition of gelatine matrix with human thrombin to conventional methods of achieving haemostasis reduces both the intra-operative blood loss and the decrease in haemoglobin concentration post-operatively in adolescents undergoing posterior spinal fusion for idiopathic scoliosis. Take home message: A randomised clinical trial showed that gelatine matrix with human thrombin decreases intra-operative blood loss by 30% when added to traditional surgical haemostatic methods in adolescents undergoing posterior spinal fusion for idiopathic scoliosis. Cite this article: Bone Joint J 2016;98-B:395–401


Bone & Joint Research
Vol. 11, Issue 7 | Pages 494 - 502
20 Jul 2022
Kwon HM Lee J Koh Y Park KK Kang K

Aims

A functional anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) has been assumed to be required for patients undergoing unicompartmental knee arthroplasty (UKA). However, this assumption has not been thoroughly tested. Therefore, this study aimed to assess the biomechanical effects exerted by cruciate ligament-deficient knees with medial UKAs regarding different posterior tibial slopes.

Methods

ACL- or PCL-deficient models with posterior tibial slopes of 1°, 3°, 5°, 7°, and 9° were developed and compared to intact models. The kinematics and contact stresses on the tibiofemoral joint were evaluated under gait cycle loading conditions.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 453 - 464
20 Jul 2022
Wang H Shi Y He F Ye T Yu S Miao H Liu Q Zhang M

Aims

Abnormal lipid metabolism is involved in the development of osteoarthritis (OA). Growth differentiation factor 11 (GDF11) is crucial in inhibiting the differentiation of bone marrow mesenchymal stem cells into adipocytes. However, whether GDF11 participates in the abnormal adipogenesis of chondrocytes in OA cartilage is still unclear.

Methods

Six-week-old female mice were subjected to unilateral anterior crossbite (UAC) to induce OA in the temporomandibular joint (TMJ). Histochemical staining, immunohistochemical staining (IHC), and quantitative real-time polymerase chain reaction (qRT-PCR) were performed. Primary condylar chondrocytes of rats were stimulated with fluid flow shear stress (FFSS) and collected for oil red staining, immunofluorescence staining, qRT-PCR, and immunoprecipitation analysis.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 557 - 565
11 Jul 2022
Meier MK Reche J Schmaranzer F von Tengg-Kobligk H Steppacher SD Tannast M Novais EN Lerch TD

Aims

The frequency of severe femoral retroversion is unclear in patients with femoroacetabular impingement (FAI). This study aimed to investigate mean femoral version (FV), the frequency of absolute femoral retroversion, and the combination of decreased FV and acetabular retroversion (AR) in symptomatic patients with FAI subtypes.

Methods

A retrospective institutional review board-approved observational study was performed with 333 symptomatic patients (384 hips) with hip pain due to FAI evaluated for hip preservation surgery. Overall, 142 patients (165 hips) had cam-type FAI, while 118 patients (137 hips) had mixed-type FAI. The allocation to each subgroup was based on reference values calculated on anteroposterior radiographs. CT/MRI-based measurement of FV (Murphy method) and AV were retrospectively compared among five FAI subgroups. Frequency of decreased FV < 10°, severely decreased FV < 5°, and absolute femoral retroversion (FV < 0°) was analyzed.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 484 - 493
13 Jul 2022
Hayer S Niederreiter B Kalkgruber M Wanic K Maißner J Smolen JS Aletaha D Blüml S Redlich K

Aims

Insufficient treatment response in rheumatoid arthritis (RA) patients requires novel treatment strategies to halt disease progression. The potential benefit of combination of cytokine-inhibitors in RA is still unclear and needs further investigation. To explore the impact of combined deficiency of two major cytokines, namely interleukin (IL)-1 and IL-6, in this study double deficient mice for IL-1αβ and IL-6 were investigated in different tumour necrosis factor (TNF)-driven inflammatory bone disorders, namely peripheral arthritis and sacroiliitis, as well as systemic bone loss.

Methods

Disease course, histopathological features of arthritis, and micro-CT (µCT) bone analysis of local and systemic bone loss were assessed in 15-week-old IL1-/-IL6-/-hTNFtg in comparison to IL1-/-hTNFtg, IL6-/-hTNFtg, and hTNFtg mice. µCT bone analysis of single deficient and wild-type mice was also performed.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 529 - 535
1 Jul 2022
Wormald JCR Rodrigues JN Cook JA Prieto-Alhambra D Costa ML

Aims

Hand trauma accounts for one in five of emergency department attendances, with a UK incidence of over five million injuries/year and 250,000 operations/year. Surgical site infection (SSI) in hand trauma surgery leads to further interventions, poor outcomes, and prolonged recovery, but has been poorly researched. Antimicrobial sutures have been recognized by both the World Health Organization and the National Institute for Clinical Excellence as potentially effective for reducing SSI. They have never been studied in hand trauma surgery: a completely different patient group and clinical pathway to previous randomized clinical trials (RCTs) of these sutures. Antimicrobial sutures are expensive, and further research in hand trauma is warranted before they become standard of care. The aim of this protocol is to conduct a feasibility study of antimicrobial sutures in patients undergoing hand trauma surgery to establish acceptability, compliance, and retention for a definitive trial.

Methods

A two-arm, multicentre feasibility RCT of 116 adult participants with hand and wrist injuries, randomized to either antimicrobial sutures or standard sutures. Study participants and outcome assessors will be blinded to treatment allocation. Outcome measures will be recorded at baseline (preoperatively), 30 days, 90 days, and six months, and will include SSI, patient-reported outcome measures, and return to work.


Bone & Joint 360
Vol. 11, Issue 2 | Pages 5 - 10
1 Apr 2022
Zheng A Rocos B


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1442 - 1448
1 Oct 2010
Thompson N Stebbins J Seniorou M Wainwright AM Newham DJ Theologis TN

This study compares the initial outcomes of minimally invasive techniques for single-event multi-level surgery with conventional single-event multi-level surgery. The minimally invasive techniques included derotation osteotomies using closed corticotomy and fixation with titanium elastic nails and percutaneous lengthening of muscles where possible. A prospective cohort study of two matched groups was undertaken. Ten children with diplegic cerebral palsy with a mean age of ten years six months (7.11 to 13.9) had multi-level minimally invasive surgery and were matched for ambulatory level and compared with ten children with a mean age of 11 years four months (7.9 to 14.4) who had conventional single-event multi-level surgery. Gait kinematics, the Gillette Gait Index, isometric muscle strength and gross motor function were assessed before and 12 months after operation. The minimally invasive group had significantly reduced operation time and blood loss with a significantly improved time to mobilisation. There were no complications intra-operatively or during hospitalisation in either group. There was significant improvement in gait kinematics and the Gillette Gait Index in both groups with no difference between them. There was a trend to improved muscle strength in the multi-level group. There was no significant difference in gross motor function between the groups. We consider that minimally invasive single-event multi-level surgery can be achieved safely and effectively with significant advantages over conventional techniques in children with diplegic cerebral palsy


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims

Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA).

Methods

We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 9 - 11
1 Jun 2022
Foxall-Smith M