Advertisement for orthosearch.org.uk
Results 301 - 320 of 652
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 674 - 679
1 May 2017
Nuttall D Birch A Haines JF Watts AC Trail IA

Aims

Radiostereometric analysis (RSA) allows an extremely accurate measurement of early micromotion of components following arthroplasty.

Patients and Methods

In this study, RSA was used to measure the migration of 11 partially cemented fluted pegged glenoid components in patients with osteoarthritis who underwent total shoulder arthroplasty using an improved surgical technique (seven men, four women, mean age 68). Patients were evaluated clinically using the American Shoulder and Elbow Surgeons (ASES) and Constant-Murley scores and by CT scans two years post-operatively.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims

Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time.

Patients and Methods

Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims

The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA.

Patients and Methods

This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 755 - 760
1 Jun 2018
Lou T Hamushan M Li H Wang C Chai Y Han P

Aims

The aim of this study was to describe the technique of distraction osteogenesis followed by arthrodesis using internal fixation to manage complex conditions of the ankle, and to present the results of this technique.

Patients and Methods

Between 2008 and 2014, distraction osteogenesis followed by arthrodesis using internal fixation was performed in 12 patients with complex conditions of the ankle due to trauma or infection. There were eight men and four women: their mean age was 35 years (23 to 51) at the time of surgery. Bone healing and functional recovery were evaluated according to the criteria described by Paley. Function was assessed using the ankle-hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS).


Aims

The objective of this study was to compare early postoperative functional outcomes and time to hospital discharge between conventional jig-based total knee arthroplasty (TKA) and robotic-arm assisted TKA.

Patients and Methods

This prospective cohort study included 40 consecutive patients undergoing conventional jig-based TKA followed by 40 consecutive patients receiving robotic-arm assisted TKA. All surgical procedures were performed by a single surgeon using the medial parapatellar approach with identical implant designs and standardized postoperative inpatient rehabilitation. Inpatient functional outcomes and time to hospital discharge were collected in all study patients.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 2 - 7
1 Aug 2017
Titchener AG Tambe AA Clark DI


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 725 - 732
1 Jun 2018
Gibon E Barut N Courpied J Hamadouche M

Aims

The purpose of this retrospective study was to evaluate the minimum five-year outcome of revision total hip arthroplasty (THA) using the Kerboull acetabular reinforcement device (KARD) in patients with Paprosky type III acetabular defects and destruction of the inferior margin of the acetabulum.

Patients and Methods

We identified 36 patients (37 hips) who underwent revision THA under these circumstances using the KARD, fresh frozen allograft femoral heads, and reconstruction of the inferior margin of the acetabulum. The Merle d’Aubigné system was used for clinical assessment. Serial anteroposterior pelvic radiographs were used to assess migration of the acetabular component.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 35 - 38
1 Apr 2018


Bone & Joint 360
Vol. 7, Issue 2 | Pages 23 - 25
1 Apr 2018


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 5 - 11
1 Jan 2017
Vulcano E Myerson MS

The last decade has seen a considerable increase in the use of in total ankle arthroplasty (TAA) to treat patients with end-stage arthritis of the ankle. However, the longevity of the implants is still far from that of total knee and hip arthroplasties.

The aim of this review is to outline a diagnostic and treatment algorithm for the painful TAA to be used when considering revision surgery.

Cite this article: Bone Joint J 2017;99-B:5–11.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 480 - 484
1 Apr 2018
Kadum B Inngul C Ihrman R Sjödén GO Sayed-Noor AS

Aims

The aims of this study were to investigate any possible relationship between a preoperative sensitivity to pain and the degree of pain at rest and on exertion with postoperative function in patients who underwent stemless total shoulder arthroplasty (TSA).

Patients and Methods

In this prospective study, we included 63 patients who underwent stemless TSA and were available for evaluation one year postoperatively. There were 31 women and 32 men; their mean age was 71 years (53 to 89). The pain threshold, which was measured using a Pain Matcher (PM) unit, the degree of pain (visual analogue scale at rest and on exertion, and function using the short version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), were recorded preoperatively, as well as three and 12 months postoperatively.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1267 - 1279
1 Oct 2017
Chughtai M Piuzzi NS Khlopas A Jones LC Goodman SB Mont MA

Non-traumatic osteonecrosis of the femoral head is a potentially devastating condition, the prevalence of which is increasing. Many joint-preserving forms of treatment, both medical and surgical, have been developed in an attempt to slow or reverse its progression, as it usually affects young patients.

However, it is important to evaluate the best evidence that is available for the many forms of treatment considering the variation in the demographics of the patients, the methodology and the outcomes in the studies that have been published, so that it can be used effectively.

The purpose of this review, therefore, was to provide an up-to-date, evidence-based guide to the management, both non-operative and operative, of non-traumatic osteonecrosis of the femoral head.

Cite this article: Bone Joint J 2017;99-B:1267–79.


Bone & Joint Research
Vol. 7, Issue 4 | Pages 282 - 288
1 Apr 2018
Beckmann NA Bitsch RG Gondan M Schonhoff M Jaeger S

Objectives

In order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined.

Methods

A total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm augment. Each acetabular component and augment was affixed to the bone using two screws, while the method of fixation between the acetabular component and augment varied for the three groups of six hemipelvises: group S, screw fixation only; group SC, screw plus cement fixation; group C, cement fixation only. The implanted hemipelvises were cyclically loaded to three different loading maxima (0.5 kN, 0.9 kN, and 1.8 kN).


Bone & Joint 360
Vol. 7, Issue 1 | Pages 30 - 32
1 Feb 2018


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 396 - 403
1 Mar 2018
Messner J Johnson L Taylor DM Harwood P Britten S Foster P

Aims

The aim of this study was to report the clinical, functional and radiological outcomes of children and adolescents with tibial fractures treated using the Ilizarov method.

Patients and Methods

Between 2013 and 2016 a total of 74 children with 75 tibial fractures underwent treatment at our major trauma centre using an Ilizarov frame. Demographic and clinical information from a prospective database was supplemented by routine functional and psychological assessment and a retrospective review of the notes and radiographs.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 17 - 25
1 Apr 2017
Khan T Grindlay D Ollivere BJ Scammell BE Manktelow ARJ Pearson RG

Aims

The aim of this study was to investigate the outcomes of Vancouver type B2 and B3 fractures by performing a systematic review of the methods of surgical treatment which have been reported.

Materials and Methods

A systematic search was performed in Ovid MEDLINE, Embase and the Cochrane Central Register of Controlled Trials. For inclusion, studies required a minimum of ten patients with a Vancouver type B2 and/or ten patients with a Vancouver type B3 fracture, a minimum mean follow-up of two years and outcomes which were matched to the type of fracture. Studies were also required to report the rate of re-operation as an outcome measure. The protocol was registered in the PROSPERO database.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 3 - 8
1 Jan 2018
Ibrahim MS Twaij H Haddad FS

Aims

Periprosthetic joint infection (PJI) remains a challenging complication following total hip arthroplasty (THA). It is associated with high levels of morbidity, mortality and expense. Guidelines and protocols exist for the management of culture-positive patients. Managing culture-negative patients with a PJI poses a greater challenge to surgeons and the wider multidisciplinary team as clear guidance is lacking.

Patients and Methods

We aimed to compare the outcomes of treatment for 50 consecutive culture-negative and 50 consecutive culture-positive patients who underwent two-stage revision THA for chronic infection with a minimum follow-up of five years.


Bone & Joint Research
Vol. 7, Issue 2 | Pages 187 - 195
1 Feb 2018
Ziebart J Fan S Schulze C Kämmerer PW Bader R Jonitz-Heincke A

Objectives

Enhanced micromotions between the implant and surrounding bone can impair osseointegration, resulting in fibrous encapsulation and aseptic loosening of the implant. Since the effect of micromotions on human bone cells is sparsely investigated, an in vitro system, which allows application of micromotions on bone cells and subsequent investigation of bone cell activity, was developed.

Methods

Micromotions ranging from 25 µm to 100 µm were applied as sine or triangle signal with 1 Hz frequency to human osteoblasts seeded on collagen scaffolds. Micromotions were applied for six hours per day over three days. During the micromotions, a static pressure of 527 Pa was exerted on the cells by Ti6Al4V cylinders. Osteoblasts loaded with Ti6Al4V cylinders and unloaded osteoblasts without micromotions served as controls. Subsequently, cell viability, expression of the osteogenic markers collagen type I, alkaline phosphatase, and osteocalcin, as well as gene expression of osteoprotegerin, receptor activator of NF-κB ligand, matrix metalloproteinase-1, and tissue inhibitor of metalloproteinase-1, were investigated.


Bone & Joint Research
Vol. 7, Issue 3 | Pages 232 - 243
1 Mar 2018
Winkler T Sass FA Duda GN Schmidt-Bleek K

Despite its intrinsic ability to regenerate form and function after injury, bone tissue can be challenged by a multitude of pathological conditions. While innovative approaches have helped to unravel the cascades of bone healing, this knowledge has so far not improved the clinical outcomes of bone defect treatment. Recent findings have allowed us to gain in-depth knowledge about the physiological conditions and biological principles of bone regeneration. Now it is time to transfer the lessons learned from bone healing to the challenging scenarios in defects and employ innovative technologies to enable biomaterial-based strategies for bone defect healing. This review aims to provide an overview on endogenous cascades of bone material formation and how these are transferred to new perspectives in biomaterial-driven approaches in bone regeneration.

Cite this article: T. Winkler, F. A. Sass, G. N. Duda, K. Schmidt-Bleek. A review of biomaterials in bone defect healing, remaining shortcomings and future opportunities for bone tissue engineering: The unsolved challenge. Bone Joint Res 2018;7:232–243. DOI: 10.1302/2046-3758.73.BJR-2017-0270.R1.