Advertisement for orthosearch.org.uk
Results 281 - 300 of 1097
Results per page:
Bone & Joint 360
Vol. 10, Issue 4 | Pages 14 - 17
1 Aug 2021


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients. Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty. Cite this article: Bone Joint J 2015;97-B:1377–84


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1222 - 1230
1 Jul 2021
Slullitel PA Garcia-Barreiro GG Oñativia JI Zanotti G Comba F Piccaluga F Buttaro MA

Aims

We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty.

Methods

We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.


Bone & Joint 360
Vol. 10, Issue 5 | Pages 7 - 10
1 Oct 2021
Morris DLJ Cresswell T Espag M Tambe AA Clark DI Ollivere BJ


Bone & Joint 360
Vol. 10, Issue 5 | Pages 15 - 18
1 Oct 2021


Bone & Joint Research
Vol. 10, Issue 7 | Pages 380 - 387
5 Jul 2021
Shen J Sun D Fu J Wang S Wang X Xie Z

Aims

In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for tibial plateau fractures (TPFs). This study investigates the effect of induced membrane technique combined with internal fixation for managing SSI in TPF patients who underwent ORIF.

Methods

From April 2013 to May 2017, 46 consecutive patients with SSI post-ORIF for TPFs were managed in our centre with an induced membrane technique. Of these, 35 patients were included for this study, with data analyzed in a retrospective manner.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 858 - 863
1 Jul 2008
Rampal V Sabourin M Erdeneshoo E Koureas G Seringe R Wicart P

The treatment of developmental dysplasia of the hip diagnosed after the first year of life remains controversial. A series of 36 children (47 hips), aged between one and 4.9 years underwent gradual closed reduction using the Petit-Morel method. A pelvic osteotomy was required in 43 hips (91.5%). The patients whose hips did not require pelvic osteotomy were among the youngest. The mean age at final follow-up was 16.1 years (11.3 to 32). The mean follow-up was 14.3 years (10 to 30). At the latest follow-up, 44 hips (93.6%) were graded as excellent or good according to the Severin classification. Closed reduction failed in only two hips (4.3%) which then required open reduction. Mild avascular necrosis was observed in one (2.1%). The accuracy of the reduction and associated low complication rate justify the use of the Petit-Morel technique as the treatment of choice for developmental dysplasia of the hip in patients aged between one and five years


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 442 - 446
1 Mar 2010
Keel MJB Bastian JD Büchler L Siebenrock KA

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply


Bone & Joint 360
Vol. 10, Issue 1 | Pages 33 - 37
1 Feb 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 975 - 979
1 Jul 2011
Gurkan V Dursun M Orhun H Sari F Bulbul M Aydogan M

A high rate of complications is associated with open reduction and internal fixation of Sanders type 4 fractures of the calcaneum. We assessed the long-term outcome of 83 Sanders type 4 comminuted intra-articular fractures of the calcaneum in 64 patients who underwent non-operative treatment between 1999 and 2005. Each fracture was treated by closed reduction and immobilisation in a long leg cast. Patients were reviewed every three months in the first year, and every six months thereafter. At each visit, the involved ankles were assessed by the American Orthopaedic Foot and Ankle Society (AOFAS) criteria. The degree of fracture healing and the presence of osteoarthritis were assessed. At a mean follow-up of 51 months (24 to 70) the mean AOFAS score was 72 (52 to 92). Osteoarthritis was scored radiologically using Graves’ classification and was evident in the subtalar joints of 75 ankles (90%) on x-ray and in all ankles on CT scans, of which 20 were grade 0 or 1, 39 grade 2, and 24 grade 3. A non-operative approach to treating these fractures may be simpler, less expensive, easier to administer with fewer complications, and may be better tolerated than surgery, by many patients


Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims

“Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs.

Methods

This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 447 - 453
1 Jun 2021
Dean BJF Little C Riley ND Sellon E Sheehan W Burford J Hormbrey P Costa ML

Aims

To determine the role of early MRI in the management of suspected scaphoid fractures.

Methods

A total of 337 consecutive patients presenting to an emergency department (ED) following wrist trauma over a 12-month period were prospectively included in this service evaluation project. MRI was not required in 62 patients with clear diagnoses, and 17 patients were not managed as per pathway, leaving a total of 258 patients with normal scaphoid series radiographs who were then referred directly from ED for an acute wrist MRI scan. Patient demographics, clinical details, outcomes, and complications were recorded at a minimum of a year following injury.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims

Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones.

Methods

A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m2 (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1100 - 1106
1 Aug 2010
Kapoor SK Kataria H Patra SR Boruah T

Open reduction and internal fixation of high-energy pilon fractures are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. A total of 17 consecutive patients with pilon fractures of AO/OTA type 43-B3 (n = 1), type C2 (n = 12) and type C3 (n = 4) were treated by indirect reduction by capsuloligamentotaxis and stabilisation using an ankle-spanning Ilizarov fixator. The calcaneal ring was removed at a mean of 3.7 weeks (3 to 6). A total of 16 patients were available for follow-up at a mean of 29 months (23 to 43). The mean time to healing was 15.8 weeks (13 to 23). Nine patients had pin-track infections but none had deep infection or osteomyelitis. Four patients (25%) had malunion. Fair, good or excellent ankle scores were found in 14 patients. External fixation with a ring fixator achieves stable reduction of the fractured fragments without additional trauma to soft tissues. With minimum complications and good healing results, the Ilizarov apparatus is particularly useful for high-energy pilon fractures


Bone & Joint 360
Vol. 10, Issue 4 | Pages 49 - 51
1 Aug 2021
Evans JT Welch M Whitehouse MR


Aims

To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component.

Methods

Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 223 - 228
1 Feb 2011
Neumann M Nyffeler R Beck M

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 809 - 812
1 May 2021
Farhan-Alanie MM Trompeter AJ Wall PDH Costa ML

The use of tourniquets in lower limb trauma surgery to control bleeding and improve the surgical field is a long established practice. In this article, we review the evidence relating to harms and benefits of tourniquet use in lower limb fracture fixation surgery and report the results of a survey on current tourniquet practice among trauma surgeons in the UK.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 262 - 265
1 Feb 2011
Kang S Mangwani J Ramachandran M Paterson JMH Barry M

We present the results of 90 consecutive children with displaced fractures of the forearm treated by elastic stable intramedullary nailing with a mean follow-up of 6.6 months (2.0 to 17.6). Eight (9%) had open fractures and 77 (86%) had sustained a fracture of both bones. The operations were performed by orthopaedic trainees in 78 patients (86%). All fractures healed at a mean of 2.9 months (1.1 to 8.7). There was one case of delayed union of an ulnar fracture. An excellent or good functional outcome was achieved in 76 patients (84%). There was no statistical difference detected when the grade of operating surgeon, age of the patient and the diaphyseal level of the fracture were correlated with the outcome. A limited open reduction was required in 40 fractures (44%). Complications included seven cases of problematic wounds, two transient palsies of the superficial radial nerve and one case each of malunion and a post-operative compartment syndrome. At final follow-up, all children were pain-free and without limitation of sport and play activities. Our findings indicate that the functional outcome following paediatric fractures of the forearm treated by elastic stable intramedullary nailing is good, without the need for anatomical restoration of the radial bow


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1090 - 1093
1 Aug 2009
van der Sluijs JA De Gier L Verbeke JI Witbreuk MMEH Pruys JEH van Royen BJ

We prospectively studied the benefits and risks of prolonged treatment with the Pavlik harness in infants with idiopathic developmental dysplasia of the hip. Bracing was continued as long as abduction improved. It was started at a mean age of four months (1 to 6.9). Outcome measures were the number of successful reductions, the time to reduction, the acetabular index and evidence of avascular necrosis at follow-up at one year. In 50 infants with 62 subluxated and dislocated hips (42 Graf type III and 20 type IV), 37 were reduced successfully with a mean time to reduction of 13.4 weeks (. sd. 6.8). Bracing was successful in 31 type-III (73.8%) and in only six type-IV hips (20%, p = 0.002). Avascular necrosis was seen in ten hips. Prolonged treatment with the Pavlik harness for developmental dysplasia of the hip over the age of one month can be beneficial in type-III hips, but it is unclear as to whether this is the optimal treatment, since it may postpone the need for closed or open reduction to a more unfavourable age. The use of the Pavlik harness in type-IV hips in this age group is questionable, but if used, prolonged bracing is not advised