The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 629 - 631
1 Aug 1989
Nunn D Freeman M Hill P Evans S

Individual components of a total hip replacement are difficult to evaluate and quantify. We have studied the assessment of the acetabular component, and conclude that the measurement of migration allows the comparison of implants, although there is no established link between migration and significant loosening. A method of measurement based on clinical radiographs has been developed, and its limitations estimated. The accuracy of the technique was calculated to be +/- 3 mm


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 302 - 304
1 Mar 1988
Bobyn J Engh C Glassman A

Threaded acetabular components are widely used in cementless total hip replacement, despite a poor understanding of the nature of the bone-implant interface. We have examined one case in which the threaded titanium ring appeared to be well incorporated with no discernible radiolucency. Microradiography and histology surprisingly showed that the threads were entirely encapsulated in fibrous tissue. This raises doubt about the relevance of plain radiography to the analysis of the acetabular interface


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 63 - 67
1 Jan 1990
Jasty M Harris W

We evaluated 38 hip reconstructions in 36 patients at a mean follow-up of 5.9 years (range 4 to 9.1) after femoral head allografts had been used to augment severely deficient acetabular bone stock. The patients were all relatively young and had many previous operations. Their pre-operative Harris hip rating averaged 46 points (range 18 to 73). All the allografts united and there were no infections. However, 12 acetabular components (32%) became loose; six of these had needed revision using the healed allograft, and two hips had required resection arthroplasty. The 30 surviving hips had a mean Harris hip score of 82 points. Some radiographic evidence of graft resorption was seen in 23 hips, though this was mild in 17. The extent of cover provided by the allograft and the severity of graft resorption both correlated with acetabular loosening. Although structural allografts had allowed successful hip reconstructions in many of these patients with major bone loss, the failure rate had increased from zero at four years to 32% at six years; clearly they provide only a short-term solution


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 568 - 574
1 Jul 1994
Huk O Bansal M Betts F Rimnac C Lieberman Huo M Salvati E

We report a prospective study of the liner-metal interfaces of modular uncemented acetabular components as sources of debris. We collected the pseudomembrane from the screw-cup junction and the empty screw holes of the metal backing of 19 acetabula after an average implantation of 22 months. Associated osteolytic lesions were separately collected in two cases. The back surfaces of the liners and the screws were examined for damage, and some liners were scanned by electron microscopy. The tissues were studied histologically and by atomic absorption spectrophotometry to measure titanium content. The pseudomembrane from the screw-cup junction contained polyethylene debris in seven specimens and metal debris in ten. The material from empty screw holes was necrotic tissue or dense fibroconnective tissue with a proliferative histiocytic infiltrate and foreign-body giant-cell reaction. It contained polyethylene debris in 14 cases and metal in five. The two acetabular osteolytic lesions also showed a foreign-body giant-cell reaction to particulate debris. The average titanium levels in pseudomembranes from the screw-cup junction and the empty screw holes were 959 micrograms/g (48 to 11,900) and 74 micrograms/g (0.72 to 331) respectively. The tissue from the two lytic lesions showed average titanium levels of 139 and 147 micrograms/g respectively. The back surfaces of the PE liners showed surface deformation, burnishing, and embedded metal debris. All 30 retrieved screws demonstrated fretting at the base of the head and on the proximal shaft. Non-articular modular junctions create new interfaces for the generation of particulate debris, which may cause granulomatous reaction


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 190 - 196
1 Mar 1990
Ogata S Moriya H Tsuchiya K Akita T Kamegaya M Someya M

The exact measurement of femoral head cover is essential for an assessment of reduction of congenital dislocation of the hip. We have compared standard anteroposterior radiographs with computerised tomograms and thereby classified the shape of the acetabular roof into four types. We found that the CE angle of Wiberg is a more reliable measure of head cover when the lateral point of bony condensation of the roof is chosen as the reference point rather than the edge of the bone, where these two points do not overlap. We conclude that head cover can be more accurately determined in younger children with dysplastic hips by our 'refined' CE angle, than by the original method of Wiberg


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 254 - 258
1 Mar 1993
Kabo J Gebhard J Loren G Amstutz H

Polyethylene acetabular cups retrieved at revision surgery were measured by a shadowgraph technique to determine linear wear, and the values were compared with those obtained from radiographs. There was a close correlation between them, although the radiographic measurements slightly underestimated the true wear. Average linear wear rates for surface-replacement components were much greater than those for conventional prostheses with femoral heads up to 32 mm in diameter. Volumetric wear, calculated using a new formula, was found to be less than previously reported in vivo, and similar in magnitude to the results of experimental wear tests in vitro. The volumetric wear rates were greatest for the surface-replacement components and, for conventional components, were found to increase in a linear manner with component diameter


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 73 - 77
1 Nov 2014
Brown NM Hellman M Haughom BH Shah RP Sporer SM Paprosky WG

A pelvic discontinuity occurs when the superior and inferior parts of the hemi-pelvis are no longer connected, which is difficult to manage when associated with a failed total hip replacement. Chronic pelvic discontinuity is found in 0.9% to 2.1% of hip revision cases with risk factors including severe pelvic bone loss, female gender, prior pelvic radiation and rheumatoid arthritis. Common treatment options include: pelvic plating with allograft, cage reconstruction, custom triflange implants, and porous tantalum implants with modular augments. The optimal technique is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable healing between the two segments. A method of treating pelvic discontinuity using porous tantalum components with a distraction technique that achieves both initial stability and subsequent long-term biological fixation is described.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):73–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 263 - 266
1 Mar 1994
Hernandez Keating E Faris P Meding J Ritter M

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated with uncemented femoral components (0.22 mm/year) was significantly higher than the wear rate (0.15 mm/year) of cups articulated within cemented femoral components (p < 0.05). These results can be compared with previously reported wear rates of 0.08 mm/year for cemented all-polyethylene cups and 0.11 mm/year for cemented metal-backed cups. The higher wear rates of uncemented arthroplasties could jeopardize the long-term results of this type of hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 372 - 376
1 May 1992
Curtis M Jinnah R Wilson V Hungerford D

The osseo-integration of an uncemented acetabular component depends on its initial stability. This is usually provided by under-reaming of the acetabulum. We have assessed the fixation of 52 mm porous-coated hemispherical prostheses inserted into cadaveric acetabula under-reamed by 1, 2, 3 and 4 mm. We tested the torsional stability of fixation, after preloading with 686 N in compression, by measuring the torque required to produce 1 degree and 2 degrees of rotation. Under-reaming by 2 mm and 3 mm gave significantly better fixation than 1 mm (p less than 0.01, p less than 0.02). Insertion after under-reaming of 4 mm caused some fractures. To obtain maximum interference fit and optimal implant stability, we recommend the use of an implant 2 mm or 3 mm larger than the last reamer


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 182 - 186
1 Mar 2003
Jeffery M Scott G Freeman M

We have reviewed 29 patients (30 hips) who had undergone revision total hip arthroplasty using a Freeman metal-backed acetabular component and acetabular impaction allografting. The mean follow-up was for 15.3 years (12 to 17). Five patients (5 hips) died with the prosthesis in situ and four (4 hips) were lost to follow-up. Twelve hips had failed and in the remaining nine there were minor symptoms. The mean time to failure requiring further surgery was nine years. Excluding patients who were lost to follow-up or had died, 72% of the hips were radiologically loose at the last review. The commonest pattern in those requiring revision was failure of the reinforcement ring in adduction with remodelling of the medial wall. Of the nine patients who had not undergone revision, one with bilateral replacements had no current radiographs and only three of the remaining seven replacements had no radiological signs of loosening. The short-term results for this technique have been reported to be satisfactory, but in the long term they are not. The factors associated with failure include the design of the prosthesis, which has been implicated in disappointing long-term results when used in primary arthroplasty, but not with the frequency of failure found in this series. It seems that the reliance on peripheral screw fixation over a bed of allograft without bridging the graft does not provide sufficient stability to allow incorporation of the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 806 - 810
1 Sep 1991
Weightman B Swanson S Isaac G Wroblewski B

Laboratory wear testing of ultra high molecular weight polyethylene from 12 Charnley acetabular cups, removed after periods of up to 17.5 years showed that the large patient-to-patient variations in clinical penetration rate cannot be explained by batch-to-batch variation in the wear resistance of the material. Nor was there any evidence of a time-dependent degradation in wear resistance of the material


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 463 - 467
1 May 1992
Hiranuma S Higuchi F Inoue A Miyazaki M

We have investigated the changes in the interposed capsule after a Chiari pelvic osteotomy, in an experimental study on dysplastic hips in 20 adolescent rabbits. Radiographic, macroscopic and microscopic observations were made up to 12 months after operation. The new acetabular roof had incorporated the interposed capsule and remodelled completely by six months. By 12 months there was a new, stable hip with continuity between the capsule and the original acetabular cartilage. Histologically, the capsule underwent metaplastic change to fibrocartilaginous tissue after six months, with some hyaline-like cartilage near the joint surface. These changes in the interposed capsule play an important role in the formation of a new joint after a Chiari pelvic osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 484 - 489
1 May 1995
Won C Hearn T Tile M

Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial stability


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 38 - 42
1 Jan 1991
Santavirta S Konttinen Y Hoikka V Eskola A

The membranes surrounding seven loose cementless acetabular implants were shown to contain polyethylene particles, birefringent in polarised light. Three of these implants were made of titanium alloy and the membranes around these contained titanium particles as well. There was no metallosis around the four implants made of chromium-cobalt-steel alloy. Both titanium and polyethylene particles caused migration, adherence and phagocytosis of CD11b-positive, peroxidase-negative macrophages. There were no histological signs of activation of the specific immune response; neither interleukin-2 receptor-positive activated T cells nor PCA-1 plasmablasts/plasma cells were present in the tissues. In cases of simple loosening, resident mesenchymal fibroblast-like cells were active. In aggressive granulomatosis, there were many macrophages and multinucleated giant cells but little fibroblast reaction. The clinical relevance of the findings is that the use of cementless prostheses is not a guarantee against adverse tissue reactions


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 949 - 952
1 Sep 2003
Mitchell PA Masri BA Garbuz DS Greidanus NV Wilson D Duncan CP

Removal of well-fixed, cementless, acetabular components during revision arthroplasty remains a challenging problem. Further damage to host bone may limit options for reconstruction and compromise the long-term result of the revision operation. We report the results of 31 hips with well-fixed, cementless sockets which were removed using a new cup extraction system. In all hips the socket was removed without difficulty and with minimal further bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 53 - 59
1 Jan 1994
Boehler M Knahr K Plenk H Walter A Salzer M Schreiber V

We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 975 - 978
1 Nov 1999
MacDonald SJ Hersche O Ganz R

We carried out the Bernese periacetabular osteotomy for the treatment of 13 dysplastic hips in 11 skeletally mature patients with an underlying neurological diagnosis. Seven hips had flaccid paralysis and six were spastic. The mean age at the time of surgery was 23 years and the mean length of follow-up was 6.4 years. Preoperatively, 11 hips had pain and two had progressive subluxation. Before operation the mean Tönnis angle was 33°, the mean centre-edge angle was −10°, and the mean extrusion index was 53%. Postoperatively, they were 8°, 25° and 15%, respectively. Pain was eliminated in 7 patients and reduced in four in those who had preoperative pain. One patient developed pain secondary to anterior impingement from excessive retroversion of the acetabulum. Four required a varus proximal femoral osteotomy at the time of the pelvic procedure and one a late varus proximal femoral osteotomy for progressive subluxation. Before operation no patient had arthritis. At the most recent follow-up one had early arthritis of the hip (Tönnis grade I) and one had advanced arthritis (Tönnis grade III). Our results suggest that the Bernese periacetabular osteotomy can be used successfully to treat neurogenic acetabular dysplasia in skeletally mature patients


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 409 - 413
1 May 1986
Ackland M Bourne W Uhthoff H

We describe a new method for the accurate measurement of the angle of anteversion of an acetabular cup from standard anteroposterior radiographs, and provide the conversion tables required. The effect of the centering of the radiograph is discussed and a method of distinguishing between anteversion and retroversion by using a caudally directed x-ray beam is described


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 575 - 578
1 Jul 1994
Berry D Barnes C Scott R Cabanela M Poss R

Ten cases are described of catastrophic failure of the polyethylene liner of three different designs of uncemented acetabular component. Failure occurred as a result of either 'wearthrough' to the metal backing, liner fracture or a combination of both, at a mean of 4.6 years after implantation (2 to 7.6). At revision there was metallosis in all hips and osteolysis of the femur or the pelvis in six. Catastrophic failure was seen only in cups with a minimum polyethylene thickness of less than 5 mm


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 25 - 27
1 Jan 1992
Coleman N Charnley G Goddard N Hashemi-Nejad A

Failure of an acetabular cup is uncommon and has been attributed to wear or creep, trauma or bony irregularities in the acetabulum. We report ten cases in which fracture of the cup occurred at the site of drill holes used to anchor the marker wire. The role of such indentations as stress raisers has not been previously reported; we suggest that deep indentations or grooves should not be placed in the most highly stressed areas and that the cup thickness should allow for predicted wear rates