Advertisement for orthosearch.org.uk
Results 261 - 280 of 437
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 541 - 547
1 Apr 2014
Kose KC Inanmaz ME Isik C Basar H Caliskan I Bal E

The purpose of this study was to evaluate and compare the effect of short segment pedicle screw instrumentation and an intermediate screw (SSPI+IS) on the radiological outcome of type A thoracolumbar fractures, as judged by the load-sharing classification, percentage canal area reduction and remodelling.

We retrospectively evaluated 39 patients who had undergone hyperlordotic SSPI+IS for an AO-Magerl Type-A thoracolumbar fracture. Their mean age was 35.1 (16 to 60) and the mean follow-up was 22.9 months (12 to 36). There were 26 men and 13 women in the study group. In total, 18 patients had a load-sharing classification score of seven and 21 a score of six. All radiographs and CT scans were evaluated for sagittal index, anterior body height compression (%ABC), spinal canal area and encroachment. There were no significant differences between the low and high score groups with respect to age, duration of follow-up, pre-operative sagittal index or pre-operative anterior body height compression (p = 0.217, 0.104, 0.104, and 0.109 respectively). The mean pre-operative sagittal index was 19.6° (12° to 28°) which was corrected to -1.8° (-5° to 3°) post-operatively and 2.4° (0° to 8°) at final follow-up (p = 0.835 for sagittal deformity). No patient needed revision for loss of correction or failure of instrumentation.

Hyperlordotic reduction and short segment pedicle screw instrumentation and an intermediate screw is a safe and effective method of treating burst fractures of the thoracolumbar spine. It gives excellent radiological results with a very low rate of failure regardless of whether the fractures have a high or low load-sharing classification score.

Cite this article: Bone Joint J 2014;96-B:541–7.


Bone & Joint Research
Vol. 6, Issue 3 | Pages 162 - 171
1 Mar 2017
Walker JA Ewald TJ Lewallen E Van Wijnen A Hanssen AD Morrey BF Morrey ME Abdel MP Sanchez-Sotelo J

Objectives

Sustained intra-articular delivery of pharmacological agents is an attractive modality but requires use of a safe carrier that would not induce cartilage damage or fibrosis. Collagen scaffolds are widely available and could be used intra-articularly, but no investigation has looked at the safety of collagen scaffolds within synovial joints. The aim of this study was to determine the safety of collagen scaffold implantation in a validated in vivo animal model of knee arthrofibrosis.

Materials and Methods

A total of 96 rabbits were randomly and equally assigned to four different groups: arthrotomy alone; arthrotomy and collagen scaffold placement; contracture surgery; and contracture surgery and collagen scaffold placement. Animals were killed in equal numbers at 72 hours, two weeks, eight weeks, and 24 weeks. Joint contracture was measured, and cartilage and synovial samples underwent histological analysis.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1405 - 1410
1 Oct 2015
Fu J Song K Zhang YG Zheng GQ Zhang GY Liu C Wang Y

Cardiac disease in patients with ankylosing spondylitis (AS) has previously been studied but not in patients with a kyphosis or in those who have undergone an operation to correct it.

The aim of this study was to measure the post-operative changes in cardiac function of patients with an AS kyphosis after pedicle subtraction osteotomy (PSO).

The original cohort consisted of 39 patients (33 men, six women). Of these, four patients (two men, two women) were lost to follow-up leaving 35 patients (31 men, four women) to study. The mean age of the remaining patients was 37.4 years (22.3 to 47.8) and their mean duration of AS was 17.0 years (4.6 to 26.4). Echocardiographic measurements, resting heart rate (RHR), physical function score (PFS), and full-length standing spinal radiographs were obtained before surgery and at the two-year follow-up.

The mean pre-operative RHR was 80.2 bpm (60.6 to 112.3) which dropped to a mean of 73.7 bpm (60.7 to 90.6) at the two-year follow-up (p = 0.0000). Of 15 patients with normal ventricular function pre-operatively, two developed mild left ventricular diastolic dysfunction (LVDD) at the two-year follow-up. Of 20 patients with mild LVDD pre-operatively only five had this post-operatively. Overall, 15 patients had normal LV diastolic function before their operation and 28 patients had normal LV function at the two-year follow-up.

The clinical improvement was 15 out of 20 (75.0%): cardiac function in patients with AS whose kyphosis was treated by PSO was significantly improved.

Cite this article: Bone Joint J 2015;97-B:1405–10.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 8 - 11
1 Aug 2015
McBride A Nicol S Monsell F


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1244 - 1251
1 Sep 2014
Khoshbin A Vivas L Law PW Stephens D Davis AM Howard A Jarvis JG Wright JG

The purpose of this study was to evaluate the long-term outcome of adults with spina bifida cystica (SBC) who had been treated either operatively or non-operatively for scoliosis during childhood.

We reviewed 45 patients with a SBC scoliosis (Cobb angle ≥ 50º) who had been treated at one of two children’s hospitals between 1991 and 2007. Of these, 34 (75.6%) had been treated operatively and 11 (24.4%) non-operatively. After a mean follow-up of 14.1 years (standard deviation (sd) 4.3) clinical, radiological and health-related quality of life (HRQOL) outcomes were evaluated using the Spina Bifida Spine Questionnaire (SBSQ) and the 36-Item Short Form Health Survey (SF-36).

Although patients in the two groups were demographically similar, those who had undergone surgery had a larger mean Cobb angle (88.0º (sd 20.5; 50.0 to 122.0); versus 65.7º (sd 22.0; 51.0 to 115.0); p < 0.01) and a larger mean clavicle–rib intersection difference (12.3 mm; (sd 8.5; 1 to 37); versus 4.1 mm, (sd 5.9; 0 to 16); p = 0.01) than those treated non-operatively. Both groups were statistically similar at follow-up with respect to walking capacity, neurological motor level, sitting balance and health-related quality of life (HRQOL) outcomes.

Spinal fusion in SBC scoliosis corrects coronal deformity and stops progression of the curve but has no clear effect on HRQOL.

Cite this article: Bone Joint J 2014; 96-B:1244–51


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 943 - 949
1 Jul 2014
Duckworth AD Mitchell MJ Tsirikos AI

We report the incidence of and risk factors for complications after scoliosis surgery in patients with Duchenne muscular dystrophy (DMD) and compare them with those of other neuromuscular conditions.

We identified 110 (64 males, 46 females) consecutive patients with a neuromuscular disorder who underwent correction of the scoliosis at a mean age of 14 years (7 to 19) and had a minimum two-year follow-up. We recorded demographic and peri-operative data, including complications and re-operations.

There were 60 patients with cerebral palsy (54.5%) and 26 with DMD (23.6%). The overall complication rate was 22% (24 patients), the most common of which were deep wound infection (9, 8.1%), gastrointestinal complications (5, 4.5%) and hepatotoxicity (4, 3.6%). The complication rate was higher in patients with DMD (10/26, 38.5%) than in those with other neuromuscular conditions (14/84, 16.7% (p = 0.019). All hepatotoxicity occurred in patients with DMD (p = 0.003), who also had an increased rate of deep wound infection (19% vs 5%) (p = 0.033). In the DMD group, no peri-operative factors were significantly associated with the rate of overall complications or deep wound infection. Increased intra-operative blood loss was associated with hepatotoxicity (p = 0.036).

In our series, correction of a neuromuscular scoliosis had an acceptable rate of complications: patients with DMD had an increased overall rate compared with those with other neuromuscular conditions. These included deep wound infection and hepatotoxicity. Hepatotoxicity was unique to DMD patients, and we recommend peri-operative vigilance after correction of a scoliosis in this group.

Cite this article: Bone Joint J 2014; 96-B:943–9.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 2 - 7
1 Aug 2015
Nicol S Jackson M Monsell F

This review explores recent advances in fixator design and used in contemporary orthopaedic practice including the management of bone loss, complex deformity and severe isolated limb injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 684 - 689
1 May 2012
Tsirikos AI Smith G

We reviewed 31 consecutive patients with Friedreich’s ataxia and scoliosis. There were 24 males and seven females with a mean age at presentation of 15.5 years (8.6 to 30.8) and a mean curve of 51° (13° to 140°). A total of 12 patients had thoracic curvatures, 11 had thoracolumbar and eight had double thoracic/lumbar. Two patients had long thoracolumbar collapsing scoliosis with pelvic obliquity and four had hyperkyphosis. Left-sided thoracic curves in nine patients (45%) and increased thoracic kyphosis differentiated these deformities from adolescent idiopathic scoliosis. There were 17 patients who underwent a posterior instrumented spinal fusion at mean age of 13.35 years, which achieved and maintained good correction of the deformity. Post-operative complications included one death due to cardiorespiratory failure, one revision to address nonunion and four patients with proximal junctional kyphosis who did not need extension of the fusion. There were no neurological complications and no wound infections. The rate of progression of the scoliosis in children kept under simple observation and those treated with bracing was less for lumbar curves during bracing and similar for thoracic curves. The scoliosis progressed in seven of nine children initially treated with a brace who later required surgery. Two patients presented after skeletal maturity with balanced curves not requiring correction. Three patients with severe deformities who would benefit from corrective surgery had significant cardiac co-morbidities.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 531 - 537
1 Nov 2016
Burgo FJ Mengelle DE Ozols A Fernandez C Autorino CM

Objectives

Studies reporting specifically on squeaking in total hip arthroplasty have focused on cementless, and not on hybrid, fixation. We hypothesised that the cement mantle of the femur might have a damping effect on the sound transmitted through the metal stem. The objective of this study was to test the effect of cement on sound propagation along different stem designs and under different fixation conditions.

Methods

An in vitro model for sound detection, composed of a mechanical suspension structure and a sound-registering electronic assembly, was designed. A pulse of sound in the audible range was propagated along bare stems and stems implanted in cadaveric bone femurs with and without cement. Two stems of different alloy and geometry were compared.


Bone & Joint 360
Vol. 5, Issue 4 | Pages 31 - 33
1 Aug 2016


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1399 - 1405
1 Oct 2016
Rohilla R Wadhwani J Devgan A Singh R Khanna M

Aims

This is a prospective randomised study which compares the radiological and functional outcomes of ring and rail fixators in patients with an infected gap (> 3 cm) nonunion of the tibia.

Patients and Methods

Between May 2008 and February 2013, 70 patients were treated at our Institute for a posttraumatic osseocutaneous defect of the tibia measuring at least 3 cm. These were randomised into two groups of 35 patients using the lottery method. Group I patients were treated with a ring fixator and group II patients with a rail fixator. The mean age was 33.2 years (18 to 64) in group I and 29.3 years (18 to 65) in group II. The mean bone gap was 5.84 cm in group I and 5.78 cm in group II.

The mean followup was 33.8 months in group I and 32.6 months in group II. Bone and functional results were assessed using the classification of the Association for the Study and Application of the Method of Ilizarov (ASAMI). Functional results were also assessed at six months using the short musculoskeletal functional assessment (SMFA) score.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 173 - 178
1 Feb 2012
Malizos KN Papasoulis E Dailiana ZH Papatheodorou LK Varitimidis SE

The introduction of a trabecular tantalum rod has been proposed for the management of early-stage osteonecrosis of the femoral head but serves as a single-point of support of the necrotic lesion. We describe a technique using two or three 4.2 mm (or later 4.7 mm) tantalum pegs for the prevention of collapse of the necrotic lesion. We prospectively studied 21 patients (26 hips) with non-traumatic osteonecrosis of the femoral head treated in this manner. Of these, 21 patients (24 hips) were available for radiological and clinical evaluation at a mean follow-up of 46 months (18 to 67). Radiological assessment showed that only eight hips deteriorated according to the Association Research Circulation Osseous classification, and four hips according to the Classification of the Japanese Investigation Committee of Health and Welfare. Functional improvement was obtained with an improvement in the mean Harris hip score from 65.2 (33.67 to 95) to 88.1 (51.72 to 100), the mean Merle D’Aubigné-Postel score from 13 (6 to 18) to 16 (11 to 18), a mean visual analogue score for pain from 5.2 (0 to 9.5) to 2.6 (0 to 7), and the mean Short-Form 36 score from 80.4 (56.8 to 107.1) to 92.4 (67.5 to 115.7). Of these 24 hips followed for a minimum of 18 months, three were considered as failures at the final follow-up, having required total hip replacement. One of the hips without full follow-up was also considered to be a failure. In more than two-thirds of the surviving hips a satisfactory clinical outcome was achieved with promising radiological findings. The estimated mean implant survival was 60 months (95% confidence interval 53.7 to 66.3).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 821 - 824
1 Jun 2012
Fushimi K Miyamoto K Fukuta S Hosoe H Masuda T Shimizu K

There have been few reports regarding the efficacy of posterior instrumentation alone as surgical treatment for patients with pyogenic spondylitis, thus avoiding the morbidity of anterior surgery. We report the clinical outcomes of six patients with pyogenic spondylitis treated effectively with a single-stage posterior fusion without anterior debridement at a mean follow-up of 2.8 years (2 to 5). Haematological data, including white cell count and level of C-reactive protein, returned to normal in all patients at a mean of 8.2 weeks (7 to 9) after the posterior fusion. Rigid bony fusion between the infected vertebrae was observed in five patients at a mean of 6.3 months (4.5 to 8) post-operatively, with the remaining patient having partial union. Severe back pain was immediately reduced following surgery and the activities of daily living showed a marked improvement. Methicillin-resistant Staphylococcus aureus was detected as the causative organism in four patients.

Single-stage posterior fusion may be effective in patients with pyogenic spondylitis who have relatively minor bony destruction.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 715 - 720
1 May 2016
Mifsud M Abela M Wilson NIL

Aims

Although atlantoaxial rotatory fixation (AARF) is a common cause of torticollis in children, the diagnosis may be delayed. The condition is characterised by a lack of rotation at the atlantoaxial joint which becomes fixed in a rotated and subluxed position. The management of children with a delayed presentation of this condition is controversial. This is a retrospective study of a group of such children.

Patients and Methods

Children who were admitted to two institutions between 1988 and 2014 with a diagnosis of AARF were included. We identified 12 children (four boys, eight girls), with a mean age of 7.3 years (1.5 to 13.4), in whom the duration of symptoms on presentation was at least four weeks (four to 39). All were treated with halo traction followed by a period of cervical immobilisation in a halo vest or a Minerva jacket. We describe a simple modification to the halo traction that allows the child to move their head whilst maintaining traction. The mean follow-up was 59.6 weeks (24 to 156).


Bone & Joint Research
Vol. 5, Issue 9 | Pages 419 - 426
1 Sep 2016
Leichtle CI Lorenz A Rothstock S Happel J Walter F Shiozawa T Leichtle UG

Objectives

Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL).

Materials and Methods

A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 834 - 839
1 Jun 2016
Wang S Ma H Lin C Chou P Liu C Yu W Chang M

Aim

Many aspects of the surgical treatment of patients with tuberculosis (TB) of the spine, including the use of instrumentation and the types of graft, remain controversial. Our aim was to report the outcome of a single-stage posterior procedure, with or without posterior decompression, in this group of patients.

Patients and Methods

Between 2001 and 2010, 51 patients with a mean age of 62.5 years (39 to 86) underwent long posterior instrumentation and short posterior or posterolateral fusion for TB of the thoracic and lumbar spines, followed by anti-TB chemotherapy for 12 months. No anterior debridement of the necrotic tissue was undertaken. Posterior decompression with laminectomy was carried out for the 30 patients with a neurological deficit.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 997 - 1002
1 Jul 2016
Sudo HS Mayer MM Kaneda KK Núñez-Pereira S Shono SY Hitzl WH Iwasaki NI Koller HK

Aims

The aims of our study were to provide long-term information on the behaviour of the thoracolumbar/lumbar (TL/L) curve after thoracic anterior correction and fusion (ASF) and to determine the impact of ASF on pulmonary function.

Patients and Methods

A total of 41 patients (four males, 37 females) with main thoracic (MT) adolescent idiopathic scoliosis (AIS) treated with ASF were included. Mean age at surgery was 15.2 years (11 to 27). Mean follow-up period was 13.5 years (10 to 18).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 950 - 955
1 Jul 2012
Helenius I Serlo J Pajulo O

We report the results of vertebral column resection (VCR) for paediatric patients with spinal deformity. A total of 49 VCRs in paediatric patients from four university hospitals between 2005 and 2009 with a minimum two-year follow-up were retrospectively identified. After excluding single hemivertebral resections (n = 25) and VCRs performed for patients with myelomeningocele (n = 6), as well as spondylectomies performed for tumour (n = 4), there were 14 patients who had undergone full VCR at a mean age of 12.3 years (6.5 to 17.9). The aetiology was congenital scoliosis in five, neuromuscular scoliosis in three, congenital kyphosis in two, global kyphosis in two, adolescent idiopathic scoliosis in one and secondary scoliosis in one. A total of seven anteroposterior and seven posterolateral approaches were used.

The mean major curve deformity was 86° (67° to 120°) pre-operatively and 37° (17° to 80°) at the two-year follow-up; correction was a mean of 54% (18% to 86%) in the anteroposterior and 60% (41% to 70%) in the posterolateral group at the two-year follow-up (p = 0.53). The mean Scoliosis Research Society-24 total scores were 100 (92 to 108) for the anteroposterior and 102 (95 to 105) for the posterolateral group. There was one paraparesis in the anteroposterior group necessitating urgent re-decompression, with a full recovery.

Patients undergoing VCR are highly satisfied after a successful procedure.