Advertisement for orthosearch.org.uk
Results 261 - 280 of 776
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 32 - 37
1 Jan 1984
Leung P Chow Y

A new method of treating large bony defects of the proximal femur is described. The defect is filled with a large vascular-pedicled bone graft from the iliac crest. The graft, being nourished by the deep circumflex iliac vessels, remains viable and therefore induces rapid healing of the bone. This method of bony replacement encourages adequate excision of potentially malignant bone lesions and provides sufficient mechanical support to allow early walking. Six clinical cases are presented to illustrate its application


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 38 - 45
1 Jul 2021
Horberg JV Coobs BR Jiwanlal AK Betzle CJ Capps SG Moskal JT

Aims

Use of the direct anterior approach (DAA) for total hip arthroplasty (THA) has increased in recent years due to proposed benefits, including a lower risk of dislocation and improved early functional recovery. This study investigates the dislocation rate in a non-selective, consecutive cohort undergoing THA via the DAA without any exclusion or bias in patient selection based on habitus, deformity, age, sex, or fixation method.

Methods

We retrospectively reviewed all patients undergoing THA via the DAA between 2011 and 2017 at our institution. Primary outcome was dislocation at minimum two-year follow-up. Patients were stratified by demographic details and risk factors for dislocation, and an in-depth analysis of dislocations was performed.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 25 - 32
1 Jul 2021
Amstutz HC Le Duff MJ

Aims

Adverse local tissue reactions associated with abnormal wear considerably slowed down the general use of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), now limited to a few specialized centres. In this study, we provide the clinical results of 400 consecutive MoM HRAs implanted more than 20 years ago in one such centre.

Methods

A total of 355 patients (400 hips) were treated with Conserve Plus HRA between November 1996 and November 2000. There were 96 female (27%) and 259 male patients (73%). Their mean age was 48.2 years (SD 10.9). The University of California, Los Angeles (UCLA) hip scores and 12-item Short Form Survey (SF-12) quality of life scores were reported. Survivorship was assessed using Kaplan-Meier analyses.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 423 - 429
1 Mar 2021
Diez-Escudero A Hailer NP

Periprosthetic joint infection (PJI) is one of the most dreaded complications after arthroplasty surgery; thus numerous approaches have been undertaken to equip metal surfaces with antibacterial properties. Due to its antimicrobial effects, silver is a promising coating for metallic surfaces, and several types of silver-coated arthroplasty implants are in clinical use today. However, silver can also exert toxic effects on eukaryotic cells both in the immediate vicinity of the coated implants and systemically. In most clinically-used implants, silver coatings are applied on bulk components that are not in direct contact with bone, such as in partial or total long bone arthroplasties used in tumour or complex revision surgery. These implants differ considerably in the coating method, total silver content, and silver release rates. Safety issues, such as the occurrence of argyria, have been a cause for concern, and the efficacy of silver coatings in terms of preventing PJI is also controversial. The application of silver coatings is uncommon on parts of implants intended for cementless fixation in host bone, but this option might be highly desirable since the modification of implant surfaces in order to improve osteoconductivity can also increase bacterial adhesion. Therefore, an optimal silver content that inhibits bacterial colonization while maintaining osteoconductivity is crucial if silver were to be applied as a coating on parts intended for bone contact. This review summarizes the different methods used to apply silver coatings to arthroplasty components, with a focus on the amount and duration of silver release from the different coatings; the available experience with silver-coated implants that are in clinical use today; and future strategies to balance the effects of silver on bacteria and eukaryotic cells, and to develop silver-coated titanium components suitable for bone ingrowth.

Cite this article: Bone Joint J 2021;103-B(3):423–429.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 109 - 112
1 Jan 1991
Szendroi M Karlinger K Gonda A

We report a case of systemic intraosseous lipomatosis involving the proximal femur, both ends of the tibia, and the tarsal and metatarsal bones. The lesions progressed during a five-year follow-up with a pathological fracture of the tibial plateau. CT scans were characteristic and helpful in diagnosis but MR imaging added little information. Intraosseous lipomatosis is a hamartomatous malformation due to hyperplasia of adipose tissue, and is fundamentally different from solitary benign intraosseous lipoma. Management involves reconstruction of any pathological fracture. Large progressive lesions should be treated by curettage and grafting in an attempt to prevent such fractures


Bone & Joint Research
Vol. 10, Issue 7 | Pages 445 - 458
7 Jul 2021
Zhu S Zhang X Chen X Wang Y Li S Qian W

Aims

The value of core decompression (CD) in the treatment of osteonecrosis of the femoral head (ONFH) remains controversial. We conducted a systematic review and meta-analysis to evaluate whether CD combined with other treatments could improve the clinical and radiological outcomes of ONFH patients compared with CD alone.

Methods

We searched the PubMed, Embase, Web of Science, and Cochrane Library databases until June 2020. All randomized controlled trials (RCTs) and clinical controlled trials (CCTs) comparing CD alone and CD combined with other measures (CD + cell therapy, CD + bone grafting, CD + porous tantalum rod, etc.) for the treatment of ONFH were considered eligible for inclusion. The primary outcomes of interest were Harris Hip Score (HHS), ONFH stage progression, structural failure (collapse) of the femoral head, and conversion to total hip arthroplasty (THA). The pooled data were analyzed using Review Manager 5.3 software.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 206 - 210
1 Mar 1988
Christie J Court-Brown C Kinninmonth A Howie C

Intramedullary locking nails have proved to be of considerable advantage when treating complex, comminuted or segmental femoral shaft fractures. We have reviewed 117 patients with 120 femoral shaft fractures treated with the Strasbourg device. These included 20 compound fractures, 13 pathological fractures and two non-unions. Rehabilitation and union rates have been very satisfactory and there have been no serious infections in the series. Comminution of the proximal femur has occurred in six patients and there have been three femoral neck fractures, but all of these have healed without further complications


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 205 - 211
1 Mar 1990
Paavilainen T Hoikka V Solonen K

We report the short-term results of 100 cementless total hip replacements in 52 severely dysplastic and 48 totally dislocated hips, with some new technical solutions to the problems involved. In cases with a very narrow iliac bone, the acetabular screw ring is seated below the true cotyloid area. In hips with tight flexor and abductor muscles or with deformities of the proximal femur, various osteotomies were performed. Special attention was paid to careful pre-operative planning and precise operative technique. In spite of a high complication rate the results were generally good and even patients who required reoperation were satisfied with the final result


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 231 - 237
1 Mar 2003
Holzer G Krepler P Koschat MA Grampp S Dominkus M Kotz R

We studied the bone mineral density (BMD) of 48 long-term survivors of highly malignant osteosarcoma who had been treated according to the chemotherapy protocols of the German- Swiss-Austrian Co-operative Osteosarcoma Study Group which include high-dose methotrexate. The mean age of the patients was 31 ± 4.2 years and the mean follow-up 16 ± 2.2 years. The BMD of the lumbar spine and of the proximal femur of the non-operated side was measured by dual- energy x-ray absorptiometry. A questionnaire was given to determine life-style factors, medical history and medication. Ten patients were osteoporotic, 21 osteopenic and 17 normal according to the WHO definition. Eighteen patients suffered fractures after receiving chemotherapy and all had significantly lower levels of BMD for all the sites measured


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 666 - 669
1 Jul 2000
Kawai A Backus SI Otis JC Inoue H Healey JH

We analysed the gait characteristics of 15 patients with prosthetic reconstruction of the proximal femur after resection of a malignant bone tumour using stride analysis and measurement of oxygen consumption. Compared with normal volunteers their gait was slower, with less cadence and reduced stride length. The mean net energy cost of free walking was 141% of normal. The degree of asymmetry of the single-limb support time correlated with the free-walking velocity and the net energy cost. If they used a single cane the subjects walked with less cadence, longer stride length, and prolonged single-limb support times. The net energy cost of walking and asymmetry of the single-limb support time had a negative correlation with the strength of the hip abductor muscles. Their walking performance was better than that of six subjects who had hip disarticulation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 884 - 891
1 Nov 1996
Malchau H Herberts P Wang YX Kärrholm J Romanus B

We enrolled 98 patients (107 hips) with a mean age of 47 years (SD 8.6) into a prospective study of the Madreporic Lord THR; 34 hips had primary and 73 secondary osteoarthritis. After ten years, the survival rate using revision as the endpoint for failure was 70% (±9) for the cup and 98% (±0.3) for the stem. The combined clinical and radiological survival rates were 46% (±11) and 81% (±10), respectively. Osteoporosis due to stress-shielding was observed in the proximal femur. Hips with radiologically dense bone postoperatively showed the most pronounced bone loss. We recommend continued radiological follow-up of patients with this type of implant to allow revision to be performed before there is severe bony destruction of the pelvis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 934 - 937
1 Nov 1996
Lokiec F Ezra E Khermosh O Wientroub S

We prospectively evaluated the percutaneous injection of autogenous bone marrow for the treatment of active simple bone cysts in ten consecutive children with cysts in the proximal humerus, proximal femur or tibia. The treatment included percutaneous biopsy, aspiration of fluid and the injection of autogenous bone marrow aspirated from the iliac crest. All the patients became painfree after a mean of two weeks and resumed full activities within six weeks. All ten cysts consolidated radiologically and showed remarkable remodelling within four months. Review at 12 to 48 months showed satisfactory healing without complications. Percutaneous injection of autologous bone marrow appears to be an effective treatment for active simple bone cysts


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 831 - 834
1 Sep 1996
Koot VCM Kesselaer SMMJ Clevers GJ de Hooge P Weits T van der Werken C

We studied the reliability of the Singh classification of trabecular bone structure in the proximal femur as a measure of osteoporosis, using kappa statistics. Radiographs of fractures of the femoral neck or trochanteric region in 80 consecutive patients were assessed by six observers. The interobserver variation was large; only three of 72 radiographs were given the same classification by all six observers and the kappa values ranged from 0.15 to 0.54. The intraobserver variation showed substantial strength of agreement; kappa values ranged from 0.63 to 0.88. In 77 patients dual-energy X-ray absorptiometry was used to measure bone mineral density. The results were compared with those of the Singh classification: we found no correlation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 414 - 416
1 May 1998
Eldridge JDJ Avramidis K Lee M Learmonth ID

There are several techniques for the accurate measurement of the migration of components after arthroplasty some of which require the operative placement of tantalum balls. We have reviewed the position and migration of these markers in 64 patients after total hip arthroplasty. In 40% of cases, one or more balls was seen to be outside the proximal femur on the postoperative radiograph, although all were considered to be within the bone at operation. In two hips, one ball appeared to have migrated towards the joint, although none was seen within the joint. Misplacement was not related to the experience of the surgeon or the operative approach. Migration analysis which necessitates the insertion of tantalum balls requires careful technique to avoid a potential source of third-body wear. It should probably be used only for research in small series of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 267 - 272
1 Mar 1998
Morscher EW Hefti A Aebi U

One concern about the fixation of HA-coated implants is the possible disintegration of the surface, with the migration of HA granules into the joint space, producing third-body wear. We report a study of six revisions of HA-coated polyethylene RM cups at 9 to 14 years after successful primary arthroplasty. In all six hips, we found HA granules embedded in the articulating surface of the polyethylene, with abrasive wear of the cup and the metal femoral head. The cup had loosened in four hips and three showed severe osteolysis of the proximal femur. Third-body wear due to HA particles from implant coating may produce severe clinical problems with few early warning signs. Further clinical, radiological and histological observations are needed to determine the possible incidence of this late complication in the various types of coating of a variety of substrates


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 32 - 36
1 Jan 1990
Schofield C Smibert J

We reviewed 14 patients (16 hips) treated by open reduction and upper femoral derotation osteotomy for congenital dislocation of the hip. Nine patients with 11 treated hips had growth deformities of the proximal femur; in all of them the top screw of the fixation plate lay within the cartilaginous precursor of the greater trochanter. In the five control hips the top screw was more distal. In the nine patients (mean follow-up 10.8 years) there was an increase of 14 degrees in the neck-shaft angle (p = 0.01) and of 18 degrees in the angle between the capital femoral physis and the shaft (p = 0.01) compared to the control group. This indicates that growth disturbance of the greater trochanteric apophysis as a result of plate fixation leads to long-term deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 441 - 446
1 May 1989
Cooke P Cole W Carey R

To determine the natural history of dislocation of the hip in cerebral palsy, and to evolve methods to predict dislocation, the notes and radiographs of 462 patients with cerebral palsy were reviewed. Dislocation occurred in 10% of patients by progressive migration and subluxation of the proximal femur in the presence of acetabular dysplasia. Statistical analysis identified the radiographic features that helped to predict dislocation. Measurement of acetabular index, by a method that allows for rotation of the acetabulum, was the most powerful single predictor. Measurement of this index at two and four years of age could identify patients who would dislocate unless effective treatment was undertaken, those at risk of dislocation only if scoliosis developed, and those who would not dislocate. On the basis of this method of screening for dislocation, a logical system of surgical prophylaxis is proposed


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 807 - 811
1 Nov 1987
Hoshino A Wallace W

A biomechanical study has been carried out on 20 cadaveric knees to investigate their load-absorbing mechanism. The impact load was applied using a weight falling onto the transected proximal femur and the force transmitted through the knee was measured at the transected distal tibia using a load transducer. The peak force transmitted increased as, sequentially, meniscus, articular cartilage and subchondral bone were damaged or removed. The most striking result was found in an implanted knee replacement where the transmitted force reached 180% of that in the intact knee. The results show that the joint has an impact-absorbing property in each segment and that in the osteoarthritic knee there is less absorption of shock than in the normal knee. The high impact force in an implanted knee suggests that microfractures of the cancellous bone might be expected and may produce loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 756 - 761
1 Sep 1995
Suda H Hattori T Iwata H

We studied the morphological changes in the proximal femur in 42 patients (42 hips) who had had varus derotation osteotomy of the upper femur for residual acetabular dysplasia and congenital subluxation of the hip and who did not show deformity of the head of the femur. In 19 patients the alignment of the whole leg was examined. The femoral neck-shaft angle (FNSA) at the final examination was unrelated to that immediately after operation or to the state of the acetabulum at that time. The postoperative FNSA was not related to the final result but the CE angle obtained at surgery influenced the outcome. The femoral length did not differ significantly between the unaffected and affected sides. Significant differences were found in the femorotibial angle (176.6 degrees v 174.5 degrees) and in the point of intersection between the mechanical axis and knee (65.0% v 57.2%)