Advertisement for orthosearch.org.uk
Results 241 - 260 of 1905
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 787 - 792
1 Jun 2012
Thomsen MG Husted H Bencke J Curtis D Holm G Troelsen A

The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain and satisfaction, as well as during activity. A total of 24 female patients with bilateral osteoarthritis entered this prospective, blind randomised trial in which they received a high-flex PS TKR in one knee and a gender-specific high-flexion PS TKR in the other knee. At follow-up, patients were assessed clinically measuring ROM, and questioned about pain, satisfaction and daily ‘feel’ of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median ‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.66). Gait analysis showed no statistically significant differences between the two prosthetic designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with significant improvements in several gait parameters without evidence of any advantage in the gender-specific design


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1043 - 1049
1 Aug 2016
Huijbregts HJTAM Khan RJK Fick DP Hall MJ Punwar SA Sorensen E Reid MJ Vedove SD Haebich S

Aims. We conducted a randomised controlled trial to assess the accuracy of positioning and alignment of the components in total knee arthroplasty (TKA), comparing those undertaken using standard intramedullary cutting jigs and those with patient-specific instruments (PSI). Patients and Methods. There were 64 TKAs in the standard group and 69 in the PSI group. The post-operative hip-knee-ankle (HKA) angle and positioning was investigated using CT scans. Deviation of > 3° from the planned position was regarded as an outlier. The operating time, Oxford Knee Scores (OKS) and Short Form-12 (SF-12) scores were recorded. Results. There were 14 HKA-angle outliers (22%) in the standard group and nine (13%) in the PSI group (p = 0.251). The mean HKA-angle was 0.5° varus in the standard group and 0.2° varus in the PSI group (p = 0.492). The accuracy of alignment in the coronal and axial planes and the proportion of outliers was not different in the two groups. The femoral component was more flexed (p = 0.035) and there were significantly more tibial slope outliers (29% versus 13%) in the PSI group (p = 0.032). Operating time and the median three-month OKS were similar (p = 0.218 and p = 0.472, respectively). Physical and mental SF-12 scores were not significantly different at three months (p = 0.418 and p = 0.267, respectively) or at one year post-operatively (p = 0.114 and p = 0.569). The median one-year Oxford knee score was two points higher in the PSI group (p = 0.049). Conclusion. Compared with standard intramedullary jigs, the use of PSI did not significantly reduce the number of outliers or the mean operating time, nor did it clinically improve the accuracy of alignment or the median Oxford Knee Scores. Our data do not support the routine use of PSI when undertaking TKA. Cite this article: Bone Joint J 2016;98-B:1043–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 481 - 485
1 Apr 2007
Church JS Scadden JE Gupta RR Cokis C Williams KA Janes GC

Systemic emboli released during total knee replacement have been implicated as a cause of peri-operative morbidity and neurological dysfunction. We undertook a prospective, double-blind, randomised study to compare the cardiac embolic load sustained during computer-assisted and conventional, intramedullary-aligned, total knee replacement, as measured by transoesophageal echocardiography. There were 26 consecutive procedures performed by a single surgeon at a single hospital. The embolic load was scored using the modified Mayo grading system for echogenic emboli. Fourteen patients undergoing computer-assisted total knee replacement had a mean embolic score of 4.89 (3 to 7) and 12 undergoing conventional total knee replacement had a mean embolic score of 6.15 (4 to 8) on release of the tourniquet. Comparison of the groups using a two-tailed t-test confirmed a highly significant difference (p = 0.004). This study demonstrates that computer-assisted knee replacement results in the release of significantly fewer systemic emboli than the conventional procedure using intramedullary alignment


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1351 - 1355
1 Oct 2012
Collins RA Walmsley PJ Amin AK Brenkel IJ Clayton RAE

A total of 445 consecutive primary total knee replacements (TKRs) were followed up prospectively at six and 18 months and three, six and nine years. Patients were divided into two groups: non-obese (body mass index (BMI) < 30 kg/m. 2. ) and obese (BMI ≥ 30 kg/m. 2. ). The obese group was subdivided into mildly obese (BMI 30 to 35 kg/m. 2. ) and highly obese (BMI ≥ 35 kg/m. 2. ) in order to determine the effects of increasing obesity on outcome. The clinical data analysed included the Knee Society score, peri-operative complications and implant survival. There was no difference in the overall complication rates or implant survival between the two groups. Obesity appears to have a small but significant adverse effect on clinical outcome, with highly obese patients showing lower function scores than non-obese patients. However, significant improvements in outcome are sustained in all groups nine years after TKR. Given the substantial, sustainable relief of symptoms after TKR and the low peri-operative complication and revision rates in these two groups, we have found no reason to limit access to TKR in obese patients


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 166 - 171
1 Feb 2008
Lundblad H Kreicbergs A Jansson K

We suggest that different mechanisms underlie joint pain at rest and on movement in osteoarthritis and that separate assessment of these two features with a visual analogue scale (VAS) offers better information about the likely effect of a total knee replacement (TKR) on pain. The risk of persistent pain after TKR may relate to the degree of central sensitisation before surgery, which might be assessed by determining the pain threshold to an electrical stimulus created by a special tool, the Pain Matcher. Assessments were performed in 69 patients scheduled for TKR. At 18 months after operation, separate assessment of pain at rest and with movement was again carried out using a VAS in order to enable comparison of pre- and post-operative measurements. A less favourable outcome in terms of pain relief was observed for patients with a high pre-operative VAS score for pain at rest and a low pain threshold, both features which may reflect a central sensitisation mechanism


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 902 - 906
1 Jul 2014
Chareancholvanich K Pornrattanamaneewong C

We have compared the time to recovery of isokinetic quadriceps strength after total knee replacement (TKR) using three different lengths of incision in the quadriceps. We prospectively randomised 60 patients into one of the three groups according to the length of incision in the quadriceps above the upper border of the patella (2 cm, 4 cm or 6 cm). The strength of the knees was measured pre-operatively and every month post-operatively until the peak quadriceps torque returned to its pre-operative level. There was no significant difference in the mean operating time, blood loss, hospital stay, alignment or pre-operative isokinetic quadriceps strength between the three groups. Using the Kaplan–Meier method, group A had a similar mean recovery time to group B (2.0 ± 0.2 vs 2.5 ± 0.2 months, p = 0.176). Group C required a significantly longer recovery time (3.4 ± 0.3 months) than the other groups (p < 0.03). However, there were no significant differences in the mean Oxford knee scores one year post-operatively between the groups. We conclude that an incision of up to 4 cm in the quadriceps does not delay the recovery of its isokinetic strength after TKR. Cite this article: Bone Joint J 2014;96-B:902–6


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 90 - 92
1 Nov 2012
Parvizi J Rasouli MR

In this paper, we will consider the current role of simultaneous-bilateral TKA. Based on available evidence, it is our opinion that simultaneous bilateral TKA carries a higher risk of morbidity and mortality and should be reserved for select few


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1392 - 1396
1 Oct 2010
Wang J Chen W Lin P Hsu C Wang C

Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the knee and an extra-articular malunion of the femur by TKR with intra-articular resection of bone and soft-tissue balancing. The femora had a mean varus deformity of 16° (8° to 23°) in the coronal plane. There were seven recurvatum deformities with a mean angulation of 11° (6° to 15°) and five antecurvatum deformities with a mean angulation of 12° (6° to 15°). The mean follow-up was 93 months (30 to 155). The median Knee Society knee and function scores improved from 18.7 (0 to 49) and 24.5 (10 to 50) points pre-operatively to 93 (83 to 100) and 90 (70 to 100) points at the time of the last follow-up, respectively. The mean mechanical axis of the knee improved from 22.6° of varus (15° to 27° pre-operatively to 1.5° of varus (3° of varus to 2° of valgus) at the last follow-up. The recurvatum deformities improved from a mean of 11° (6° to 15°) pre-operatively to 3° (0° to 6°) at the last follow-up. The antecurvatum deformities in the sagittal plane improved from a mean of 12° (6° to 16°) pre-operatively to 4.4° (0° to 8°) at the last follow-up. Apart from varus deformities, TKR with intra-articular bone resection effectively corrected the extra-articular deformity of the femur in the presence of antecurvatum of up to 16° and recurvatum of up to 15°


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1006 - 1010
1 Aug 2006
Forster MC Bauze AJ Bailie AG Falworth MS Oakeshott RD

The clinical results of bilateral total knee replacement staged at a one-week interval during a single hospital admission were compared with bilateral total knee replacements performed under the same anaesthetic and with bilateral total knee replacements performed during two separate admissions. The data were retrospectively reviewed. All operations had been performed by the same surgeon using the same design of prosthesis at a single institution. The operative time and length of stay for the one-week staged group were comparable with those of the separate admission group but longer than for the patients treated under one anaesthetic. There was a low rate of complications and good clinical outcome in all groups at a mean follow-up of four years (1 to 7.2). The group staged at a one-week interval had the least blood loss (p = 0.004). With appropriate patient selection, bilateral total knee replacement performed under a single anaesthetic, or staged at a one-week interval, is a safe and effective method to treat bilateral arthritis of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 745 - 749
1 Jun 2009
Ritter MA

The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age > 70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p < 0.0001) but pre-operative valgus alignment reduced survival (95.1%, 95% CI 90.0 to 97.6) (p = 0.0056). Age < 55 (p = 0.129), pre-operative varus alignment (p = 0.707), osteonecrosis (p = 0.06), rheumatoid arthritis (p = 0.247), and gender (p = 0.666) were not statistically associated with failure. We attribute the success of the AGC implant to its relatively unconstrained articular geometry and the durability of a non-modular metal-backed tibial component with compression moulded polyethylene


Bone & Joint Research
Vol. 9, Issue 6 | Pages 279 - 281
1 Jun 2020
Clement ND Deehan DJ


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1319 - 1328
1 Oct 2017
Shelton TJ Nedopil AJ Howell SM Hull ML

Aims. The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces. Patients and Methods. The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria. Results. The proportion of patients with outlier varus or valgus alignment was 16%/24% for the HKA angle, 55%/0% for the PMTA, 0%/57% for the DLFA, 25%/12% for the TFA, 100%/0% for the TCA, and 0%/64% for the FCA. In general, the forces in the medial and lateral compartments of those with outlier alignment were not different from those with in-range alignment except for the TFA, in which patients with outlier varus alignment had a mean paradoxical force which was 6 lb higher in the lateral compartment than those with in-range alignment. None of the measurements of alignment of the limb, knee and components predicted the force in the medial or lateral compartment. Conclusion. Although kinematically aligned TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria, the intra-operative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. Cite this article: Bone Joint J 2017;99-B:1319–28


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 493 - 497
1 Apr 2013
Hino K Ishimaru M Iseki Y Watanabe S Onishi Y Miura H

There are several methods for evaluating stability of the joint during total knee replacement (TKR). Activities of daily living demand mechanical loading to the knee joint, not only in full extension, but also in mid-flexion. The purpose of this study was to compare the varus-valgus stability throughout flexion in knees treated with either cruciate-retaining or posterior-stabilised TKR, using an intra-operative navigation technique. A total of 34 knees underwent TKR with computer navigation, during which the investigator applied a maximum varus-valgus stress to the knee while steadily moving the leg from full extension to flexion both before and after prosthetic implantation. The femorotibial angle was measured simultaneously by the navigation system at every 10° throughout the range of movement. It was found that posterior-stabilised knees had more varus-valgus laxity than cruciate-retaining knees at all angles examined, and the differences were statistically significant at 10° (p = 0.0093), 20° (p = 0.0098) and 30° of flexion (p = 0.0252). Cite this article: Bone Joint J 2013;95-B:493–7


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1044 - 1048
1 Aug 2009
Jackson MP Sexton SA Walter WL Walter WK Zicat BA

We evaluated 535 consecutive primary cementless total knee replacements (TKR). The mean follow-up was 9.2 years (0.3 to 12.9) and information on implant survival was available for all patients. Patients were divided into two groups: 153 obese patients (BMI ≥ 30) and 382 non-obese (BMI < 30). A case-matched study was performed on the clinical and radiological outcome, comparing 50 knees in each group. We found significantly lower mean improvements in the clinical score (p = 0.044) and lower post-operative total clinical scores in the obese group (p = 0.041). There was no difference in the rate of radiological osteolysis or lucent lines, and no difference in alignment. Log rank test for survival showed no significant differences between the groups (p = 0.167), with a ten-year survival rate of 96.4% (95% confidence interval (CI) 92 to 99) in the obese and 98% (95% CI 96 to 99) in the non-obese. The mid-term survival of TKR in the obese and the non-obese are comparable, but obesity appears to have a negative effect on the clinical outcome. However, good results and high patient satisfaction are still to be expected, and it would seem unreasonable to deny patients a TKR simply on the basis of a BMI indicating obesity


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 205 - 209
1 Feb 2011
Willis-Owen CA Keene GC Oakeshott RD

Metallosis is a rare cause of failure after total knee replacement and has only previously been reported when there has been abnormal metal-on-metal contact. We describe 14 patients (15 knees) whose total knee replacement required revision for a new type of early failure caused by extensive metallosis. A modification of a cementless rotating platform implant, which had previously had excellent long-term survival, had been used in each case. The change was in the form of a new porous-beaded surface on the femoral component to induce cementless fixation, which had been used successfully in the fixation of acetabular and tibial components. This modification appeared to have resulted in metallosis due to abrasive two-body wear. The component has subsequently been recalled and is no longer in use. The presentation, investigation, and findings at revision are described and a possible aetiology and its implications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 734 - 739
1 Jun 2006
Campbell DG Duncan WW Ashworth M Mintz A Stirling J Wakefield L Stevenson TM

A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II prosthesis, with or without a cemented polyethylene patellar component. Knee function was evaluated using the American Knee Society score, Western Ontario and McMaster University Osteoarthritis index, specific patellofemoral-related questions and radiographic evaluation until the fourth post-operative year, then via questionnaire until ten years post-operatively. A ten-point difference in the American Knee Society score between the two groups was considered a significant change in knee performance, with α and β levels of 0.05. The mean age of the patients in the resurfaced group was 71 years (53 to 88) and in the non-resurfaced group was 73 years (54 to 86). After ten years 22 patients had died, seven were suffering from dementia, three declined further participation and ten were lost to follow-up. Two patients in the non-resurfaced group subsequently had their patellae resurfaced. In the resurfaced group one patient had an arthroscopic lateral release. There was no significant difference between the two treatment groups: both had a similar deterioration of scores with time, and no further patellofemoral complications were observed in either group. We are unable to recommend routine patellar resurfacing in osteoarthritic patients undergoing total knee replacement on the basis of our findings


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 52 - 58
1 Jan 2013
Clement ND Jenkins PJ DM Nie YX Patton JT Breusch SJ Howie CR Biant LC

We assessed the effect of social deprivation upon the Oxford knee score (OKS), the Short-Form 12 (SF-12) and patient satisfaction after total knee replacement (TKR). An analysis of 966 patients undergoing primary TKR for symptomatic osteoarthritis (OA) was performed. Social deprivation was assessed using the Scottish Index of Multiple Deprivation. Those patients that were most deprived underwent surgery at an earlier age (p = 0.018), were more likely to be female (p = 0.046), to endure more comorbidities (p = 0.04) and to suffer worse pain and function according to the OKS (p < 0.001). In addition, deprivation was also associated with poor mental health (p = 0.002), which was assessed using the mental component (MCS) of the SF-12 score. Multivariable analysis was used to identify independent predictors of outcome at one year. Pre-operative OKS, SF-12 MCS, back pain, and four or more comorbidities were independent predictors of improvement in the OKS (all p < 0.001). Pre-operative OKS and improvement in the OKS were independent predictors of dissatisfaction (p = 0.003 and p < 0.001, respectively). Although improvement in the OKS and dissatisfaction after TKR were not significantly associated with social deprivation per se, factors more prevalent within the most deprived groups significantly diminished their improvement in OKS and increased their rate of dissatisfaction following TKR. Cite this article: Bone Joint J 2013;95-B:52–8


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 210 - 216
1 Feb 2014
Hanusch BC O’Connor DB Ions P Scott A Gregg PJ

This cohort study investigated the influence of psychological factors, including perception of illness, anxiety and depression on recovery and functional outcome after total knee replacement surgery. . A total of 100 patients (55 male; 45 female) with a mean age of 71 (42 to 92) who underwent a primary total knee replacement for osteoarthritis were recruited into this study. In all 97 participants completed the six week and 87 the one year follow-up questionnaires. . Pre-operatively patients completed the revised Illness Perception Questionnaire, Hospital Anxiety and Depression Scale and Recovery Locus of Control Scale. Function was assessed pre-operatively, at six weeks and one year using Oxford Knee Score (OKS) and the goniometer-measured range of movement (ROM). . The results showed that pre-operative function had the biggest impact on post-operative outcome for ROM and OKS. In addition questionnaire variables and depression had an impact on the OKS at six weeks. Depression and anxiety were also associated with a higher (worse) knee score at one year but did not influence the ROM at either six weeks or one year. Recovery from total knee replacement can be difficult to predict. This study has identified psychological factors that play an important role in recovery from surgery and functional outcome. These should be taken into account when considering patients for total knee replacement. Cite this article: Bone Joint J 2014;96-B:210–16


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 490 - 497
1 Apr 2016
Maempel JF Wickramasinghe NR Clement ND Brenkel IJ Walmsley PJ

Aims. The pre-operative level of haemoglobin is the strongest predictor of the peri-operative requirement for blood transfusion after total knee arthroplasty (TKA). There are, however, no studies reporting a value that could be considered to be appropriate pre-operatively. . This study aimed to identify threshold pre-operative levels of haemoglobin that would predict the requirement for blood transfusion in patients who undergo TKA. . Patients and Methods. Analysis of receiver operator characteristic (ROC) curves of 2284 consecutive patients undergoing unilateral TKA was used to determine gender specific thresholds predicting peri-operative transfusion with the highest combined sensitivity and specificity (area under ROC curve 0.79 for males; 0.78 for females). Results. Threshold levels of 13.75 g/dl for males and 12.75 g/dl for females were identified. The rates of transfusion in males and females, respectively above these levels were 3.37% and 7.11%, while below these levels, they were 16.13% and 28.17%. Pre-operative anaemia increased the rate of transfusion by 6.38 times in males and 6.27 times in females. Blood transfusion was associated with an increased incidence of early post-operative confusion (odds ratio (OR) = 3.44), cardiac arrhythmia (OR = 5.90), urinary catheterisation (OR = 1.60), the incidence of deep infection (OR = 4.03) and mortality (OR = 2.35) one year post-operatively, and increased length of stay (eight days vs six days, p < 0.001). . Conclusion. Uncorrected low pre-operative levels of haemoglobin put patients at potentially modifiable risk and attempts should be made to correct this before TKA. Target thresholds for the levels of haemoglobin pre-operatively in males and females are proposed. Take home message: Low pre-operative haemoglobin levels put patients at unnecessary risk and should be corrected prior to surgery. Cite this article: Bone Joint J 2016;98-B:490–7


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 471 - 476
1 Apr 2007
Kim Y Kim J Yoon S

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3). The operating and tourniquet times were significantly longer in the navigation group (p < 0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920). In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement