To analyse the influence of upper extremity trauma on the long-term
outcome of polytraumatised patients. A total of 629 multiply injured patients were included in a follow-up
study at least ten years after injury (mean age 26.5 years, standard
deviation 12.4). The extent of the patients’ injury was classified
using the Injury Severity Score. Outcome was measured using the
Hannover Score for Polytrauma Outcome (HASPOC), Short Form (SF)-12, rehabilitation
duration, and employment status. Outcomes for patients with and
without a fracture of the upper extremity were compared and analysed
with regard to specific fracture regions and any additional brachial
plexus lesion.Aims
Patients and Methods
Transtrochanteric rotational osteotomy (TRO) is performed for
young patients with non-traumatic osteonecrosis of the femoral head
(ONFH) to preserve the hip. We aimed to investigate the long-term
outcomes and the risk factors for failure 15 years after this procedure. This study included 95 patients (111 hips) with a mean age of
40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up
was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were
performed with conversion to total hip arthroplasty (THA) and radiological
failure due to secondary collapse of the femoral head or osteoarthritic changes
as the endpoint. Multivariate analyses were performed to assess
risk factors for each outcome.Aims
Patients and Methods
Rates of mortality as high as 25% to 30% have been described
following fractures of the odontoid in the elderly population. The
aim of this study was to examine whether easily identifiable variables
present on admission are associated with mortality. A consecutive series of 83 elderly patients with a fracture of
the odontoid following a low-impact injury was identified retrospectively.
Data that were collected included demographics, past medical history
and the results of blood tests on admission. Radiological investigations
were used to assess the Anderson and D’Alonzo classification and
displacement of the fracture. The mean age was 82.9 years (65 to
101). Most patients (66; 79.5%) had a type 2 fracture. An associated
neurological deficit was present in 11 (13.3%). All were treated
conservatively; 80 (96.4%) with a hard collar and three (3.6%) with
halo vest immobilisation.Aims
Patients and Methods
Periacetabular osteotomy is an effective way of treating symptomatic
hip dysplasia. We describe a new minimally invasive technique using
a modification of the Smith-Peterson approach. We performed a prospective, longitudinal cohort study to assess
for any compromise in acetabular correction when using this approach,
and to see if the procedure would have a higher complication rate
than that quoted in the literature for other approaches. We also
assessed for any improvement in functional outcome. From 168 consecutive patients (189 hips) who underwent acetabular
correction between March 2010 and March 2013 we excluded those who
had undergone previous pelvic surgery for DDH and those being treated
for acetabular retroversion. The remaining 151 patients (15 men,
136 women) (166 hips) had a mean age of 32 years (15 to 56) and the
mean duration of follow-up was 2.8 years (1.2 to 4.5). In all 90%
of cases were Tönnis grade 0 or 1. Functional outcomes were assessed
using the Non Arthritic Hip Score (NAHS), University of California,
Los Angeles (UCLA) and Tegner activity scores.Aims
Patients and Methods
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
Lumbar disc herniation (LDH) is uncommon in youth
and few cases are treated surgically. Very few outcome studies exist
for LDH surgery in this age group. Our aim was to explore differences
in gender in pre-operative level of disability and outcome of surgery
for LDH in patients aged ≤ 20 years using prospectively collected
data. From the national Swedish SweSpine register we identified 180
patients with one-year and 108 with two-year follow-up data ≤ 20
years of age, who between the years 2000 and 2010 had a primary
operation for LDH. Both male and female patients reported pronounced impairment
before the operation in all patient reported outcome measures, with
female patients experiencing significantly greater back pain, having
greater analgesic requirements and reporting significantly inferior
scores in EuroQol (EQ-5D-index), EQ-visual analogue scale, most aspects
of Short Form-36 and Oswestry Disabilities Index, when compared
with male patients. Surgery conferred a statistically significant
improvement in all registered parameters, with few gender discrepancies.
Quality of life at one year following surgery normalised in both
males and females and only eight patients (4.5%) were dissatisfied with
the outcome. Virtually all parameters were stable between the one-
and two-year follow-up examination. LDH surgery leads to normal health and a favourable outcome in
both male and female patients aged 20 years or younger, who failed
to recover after non-operative management. Cite this article:
Our purpose was to determine the quality of current randomised
controlled trials (RCTs) in hand surgery using standardised metrics. Based on five-year mean impact factors, we selected the six journals
that routinely publish studies of upper extremity surgery. Using
a journal-specific search query, 62 RCTs met our inclusion criteria.
Then three blinded reviewers used the Jadad and revised Coleman Methodology
Score (RCMS) to assess the quality of the manuscripts.Aims
Materials and Methods
The aim of the study was to develop a quantitative scoring system
to predict whether a large-to-massive rotator cuff tear was arthroscopically
reparable prior to surgery. We conducted a retrospective review of the pre-operative MR imaging
and surgical records of 87 patients (87 shoulders) who underwent
arthroscopic repair of a large-to-massive rotator cuff tear. Patients
were divided into two groups, based on the surgical outcome of the
repair. Of the 87 patients, 53 underwent complete repair (Group
I) and 34 an incomplete repair (Group II). Pre-operative MR images
were reviewed to quantify several variables. Between-group differences
were evaluated and multiple logistic regression analysis was used
to calculate the predictive value of significant variables. The
reparability index (RI) was constructed using the odds ratios of
significant variables and a receiver operating characteristic curve
analysis performed to identify the optimal RI cutoff to differentiate
between the two groups.Aims
Patients and Methods
All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05.Objectives
Materials and Methods
The purpose of this study was to determine if clinical and radiological
surveillance of cartilage tumours with low biological activity is
appropriate. A total of 98 patients with an intramedullary cartilage neoplasm
in a long bone met our inclusion criteria and were included in the
study. These patients had undergone a total of 384 scans. Patients
with radiological follow-up of more than three years (46 patients)
were divided into two groups: an active group (11 patients) and
a latent group (35 patients).Aims
Patients and Methods
One goal of total hip arthroplasty is to restore normal hip anatomy.
The aim of this study was to compare displacement of the centre
of rotation (COR) using a standard reaming technique with a technique
in which the acetabulum was reamed immediately peripherally and
referenced off the rim. In the first cohort the acetabulum was reamed to the floor followed
by sequentially larger reamers. In the second cohort the acetabulum
was only reamed peripherally, starting with a reamer the same size
as the native femoral head. Anteroposterior pelvic radiographs were
analysed for acetabular floor depth and vertical and horizontal position
of the COR.Aims
Patients and Methods
Patients with an acute Achilles tendon rupture (ATR) take a long
time to heal, have a high incidence of deep vein thrombosis (DVT)
and widely variable functional outcomes. This variation in outcome
may be explained by a lack of knowledge of adverse factors, and
a subsequent shortage of appropriate interventions. A total of 111 patients (95 men, 16 women; mean age 40.3, standard
deviation 8.4) with an acute total ATR were prospectively assessed.
At one year post-operatively a uniform outcome score, Achilles Combined
Outcome Score (ACOS), was obtained by combining three validated,
independent, outcome measures: Achilles tendon Total Rupture Score,
heel-rise height test, and limb symmetry heel-rise height. Predictors
of ACOS included treatment; gender; age; smoking; body mass index;
time to surgery; physical activity level pre- and post-injury; symptoms; quality
of life and incidence of DVT. Aims
Patients and Methods
The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.Objectives
Methods
Deep vein thrombosis is a common complication
of immobilising the lower limb after surgery. We hypothesised that
intermittent pneumatic compression (IPC) therapy in outpatients
who had undergone surgical repair of acute ruptures of the Achilles
tendon could reduce the incidence of this problem. A total of 150 patients who had undergone surgical repair of
the Achilles tendon were randomised to either treatment with IPC
for six hours per day (n = 74) under an orthosis or treatment as
usual (n = 74) in a plaster cast without IPC. At two weeks post-operatively,
the incidence of deep vein thrombosis was assessed using blinded, double-reported
compression duplex ultrasound. At this point, IPC was discontinued
and all patients were immobilised in an orthosis for a further four
weeks. At six weeks post-operatively, a second compression duplex ultrasound
scan was performed. At two weeks, the incidence of deep vein thrombosis was 21% in
the treated group and 37% in the control group (p = 0.042). Age
over 39 years was found to be a strong risk factor for deep vein
thrombosis (odds ratio (OR) = 4.84, 95% confidence interval (CI)
2.14 to 10.96). Treatment with IPC, corrected for age differences
between groups, reduced the risk of deep vein thrombosis at the
two-week point (OR = 2.60; 95% CI 1.15 to 5.91; p =0.022). At six weeks,
the incidence of deep vein thrombosis was 52% in the treated group
and 48% in the control group (OR 0.94, 95% CI 0.49 to 1.83). IPC
appears to be an effective method of reducing the risk of deep vein
thrombosis in the early stages of post-operative immobilisation
of outpatients. Further research is necessary to elucidate whether
it can confer similar benefits over longer periods of immobilisation
and in a more heterogeneous group of patients. Cite this article:
This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation.Objectives
Materials and Methods
Osteoarthritis (OA) is characterised by articular cartilage degradation. MicroRNAs (miRNAs) have been identified in the development of OA. The purpose of our study was to explore the functional role and underlying mechanism of miR-138-5p in interleukin-1 beta (IL-1β)-induced extracellular matrix (ECM) degradation of OA cartilage. Human articular cartilage was obtained from patients with and without OA, and chondrocytes were isolated and stimulated by IL-1β. The expression levels of miR-138-5p in cartilage and chondrocytes were both determined. After transfection with miR-138-5p mimics, allele-specific oligonucleotide (ASO)-miR-138-5p, or their negative controls, the messenger RNA (mRNA) levels of aggrecan (ACAN), collagen type II and alpha 1 (COL2A1), the protein levels of glycosaminoglycans (GAGs), and both the mRNA and protein levels of matrix metalloproteinase (MMP)-13 were evaluated. Luciferase reporter assay, quantitative real-time polymerase chain reaction (qRT-PCR), and Western blot were performed to explore whether Forkhead Box C1 (FOCX1) was a target of miR-138-5p. Further, we co-transfected OA chondrocytes with miR-138-5p mimics and pcDNA3.1 (+)-FOXC1 and then stimulated with IL-1β to determine whether miR-138-5p-mediated IL-1β-induced cartilage matrix degradation resulted from targeting FOXC1.Objectives
Materials and Methods
We performed a retrospective, comparative study of elderly patients
with an increased risk from anaesthesia who had undergone either
anterior screw fixation (ASF) or halo vest immobilisation (HVI)
for a type II odontoid fracture. A total of 80 patients aged 65 years or more who had undergone
either ASF or HVI for a type II odontoid fracture between 1988 and
2013 were reviewed. There were 47 women and 33 men with a mean age
of 73 (65 to 96; standard deviation 7). All had an American Society
of Anesthesiologists score of 2 or more.Aims
Patients and Methods
Interleukin 18 (IL-18) is a regulatory cytokine that degrades the disc matrix. Bone morphogenetic protein-2 (BMP-2) stimulates synthesis of the disc extracellular matrix. However, the combined effects of BMP-2 and IL-18 on human intervertebral disc degeneration have not previously been reported. The aim of this study was to investigate the effects of the anabolic cytokine BMP-2 and the catabolic cytokine IL-18 on human nucleus pulposus (NP) and annulus fibrosus (AF) cells and, therefore, to identify potential therapeutic and clinical benefits of recombinant human (rh)BMP-2 in intervertebral disc degeneration. Levels of IL-18 were measured in the blood of patients with intervertebral disc degenerative disease and in control patients. Human NP and AF cells were cultured in a NP cell medium and treated with IL-18 or IL-18 plus BMP-2. mRNA levels of target genes were measured by real-time polymerase chain reaction, and protein levels of aggrecan, type II collagen, SOX6, and matrix metalloproteinase 13 (MMP13) were assessed by western blot analysis.Objectives
Methods
Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the entry point and orientation of the
central guide wire used for reaming the glenoid and the introduction
of the component. Manual segmentation was performed on post-operative
CT scans to compare the planned and the actual position of the entry
point (mm) and orientation of the component (°).Aims
Patients and Methods
The β-angle is a radiological tool for measuring the distance between the pathological head-neck junction and the acetabular rim with the hip in 90° of flexion in patients with femoroacetabular impingement. Initially it was measured using an open-chamber MRI. We have developed a technique to measure this angle on plain radiographs. Correlation analysis was undertaken to determine the relationship between the range of movement and the β-angle in 50 patients with femoroacetabular impingement and 50 asymptomatic control subjects. Inter- and intra-observer reliability of the β-angle was also evaluated. Patients with femoroacetabular impingement had a significantly smaller (p <
0.001) mean β-angle (15.6°, 95% confidence interval (CI) 13.3 to 17.7) compared with the asymptomatic group (38.7°, 95% CI 36.5 to 41.0). Correlation between internal rotation and the β-angle was high in the impingement group and moderate in the asymptomatic group. The β-angle had excellent inter- and intra-observer reliability in both groups. Our findings suggest that the measurement of the β-angle on plain radiography may represent a valid, reproducible and cost-effective alternative to open MRI in the assessment of the pathological bony anatomy in patients with cam, pincer and mixed femoroacetabular impingement.