Results 241 - 260 of 4287
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 295 - 300
1 Mar 1997
Resch H Povacz P Fröhlich R Wambacher M

Untreated 3- and 4-part fractures of the proximal humerus have a poor functional outcome. Open operation increases the risk of avascular necrosis and percutaneous reduction and fixation may be preferable. We report 27 patients, 9 with 3-part and 18 with 4-part fractures, treated by percutaneous reduction and screw fixation. Thirteen of the 4-part fractures were of the valgus type with no significant lateral displacement of the articular segment, and five showed significant shift. Instruments were introduced into the fracture through small incisions so that the fragments could be manoeuvred under the control of an image intensifier, taking advantage of ligamentotaxis as far as possible. A good reduction was achieved in most cases. The average follow-up was 24 months (18 to 47). All the 3-part fractures showed good to very good functional results, with an average Constant score of 91% (84% to 100%), and no signs of avascular necrosis. Good radiological results were achieved in 4-part fractures when impacted in valgus except for one patient with partial avascular necrosis of the head. In those with lateral displacement of the head, revision to a prosthesis was required in one patient because of avascular necrosis and in another because of secondary redisplacement of the fracture. Avascular necrosis was seen in 11% of 4-part fractures. The average Constant score in patients with 4-part fractures who did not need further operation was 87% (75% to 100%)


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 4 | Pages 694 - 700
1 Nov 1958
Bremner RA Graham WD

1. The results of treatment of 100 consecutive patients with pertrochanteric and basal fractures of the femur treated by early operative fixation with a McKee two-piece nail and plate are reviewed. 2. Technical failures are analysed and discussed. 3. The pattern of mortality is discussed and contrasted with that in a comparable series of patients treated conservatively. 4. It is concluded that early operative fixation is the method of choice in the management of these fractures, and that the McKee pin and plate is a satisfactory and reliable device for securing internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 579 - 582
1 May 2002
Hallam PJB Fazal MA Ashwood N Ware HE Glasgow MMS Powell JM

Fractures of the anterior intercondylar eminence in children are relatively uncommon. There is considerable debate as to the best treatment of displaced fractures, but most methods described in the literature involve an open procedure combined with some form of fixation. Using human anatomical dissections, we have shown that the transverse meniscal ligament can become incarcerated within the fracture and act as a block to reduction. We describe an arthroscopic technique which requires no fixation device and report the results of its use in eight displaced fractures. This method gives reliable results and offers the advantage of less potential morbidity


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1265 - 1270
1 Sep 2012
Bates J Mkandawire N Harrison WJ

We report a prospective single-blind controlled study of the incidence of early wound infection after internal fixation for trauma in 609 patients, of whom 132 were HIV-positive. Wounds were assessed for healing using the ASEPSIS score. There was no significant difference in the rate of infection between HIV-positive and HIV-negative patients undergoing clean surgery (4.2% vs 6%, respectively; p = 0.65). HIV-positive patients did not receive additional antibiotic prophylaxis or antiretroviral therapy as part of their management. The difference in the rate of infection between HIV-positive and HIV-negative patients with an open fracture or other contamination was not significant (33% vs 15%, respectively; p = 0.064). There was no relationship between CD4 count and infection rate. HIV status did not significantly influence the number of secondary surgical procedures (p = 0.183) or the likelihood of developing chronic osteomyelitis (p = 0.131). Although previous contamination from the time of injury was a risk factor for infection in mal- and nonunions, it was not significantly increased in HIV-positive patients (p = 0.144). We conclude that clean implant surgery in HIV-positive patients is safe, with no need for additional prophylaxis


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 291 - 294
1 Mar 1991
Ballmer F Gerber C

Five consecutive unstable fractures of the distal third of the clavicle were treated by indirect open reduction and internal fixation using a temporary Bosworth-type screw. Coracoclavicular fixation provided and maintained reduction of the fracture. Healing occurred uneventfully within nine weeks in all cases. The screw was removed under local anaesthesia after healing of the fracture and there were no surgical complications. Shoulder function was restored to the pre-injury level. Temporary coracoclavicular screw fixation appears to be a valuable alternative for the treatment of type II fractures of the distal third of the clavicle


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 168 - 172
1 Feb 2006
Mayr E de la Barrera JM Eller G Bach C Nogler M

In navigated total hip arthroplasty, the pelvis and the femur are tracked by means of rigid bodies fixed directly to the bones. Exact tracking throughout the procedure requires that the connection between the marker and bone remains stable in terms of translation and rotation. We carried out a cadaver study to compare the intra-operative stability of markers consisting of an anchoring screw with a rotational stabiliser and of pairs of pins and wires of different diameters connected with clamps. These devices were tested at different locations in the femur. Three human cadavers were placed supine on an operating table, with a reference marker positioned in the area of the greater trochanter. K-wires (3.2 mm), Steinman pins (3 and 4 mm), Apex pins (3 and 4 mm), and a standard screw were used as fixation devices. They were positioned medially in the proximal third of the femur, ventrally in the middle third and laterally in the distal portion. In six different positions of the leg, the spatial positions were recorded with a navigation system. Compared with the standard single screw, with the exception of the 3 mm Apex pins, the two-pin systems were associated with less movement of the marker and could be inserted less invasively. With the knee flexed to 90° and the dislocated hip rotated externally until the lower leg was parallel to the table (figure-four position), all the anchoring devices showed substantial deflection of 1.5° to 2.5°. The most secure area for anchoring markers was the lateral aspect of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 2 | Pages 518 - 527
1 May 1956
Blockey NJ

1. The thesis is advanced that in the treatment of fractures of the adult tibia rigid fixation is desirable. 2. The mechanical factors are discussed and a technique is described which provides a high degree of fixation without exposing more than one surface of the bone. 3. The process of healing of such fractures is described and the results in thirty-three unselected patients are given


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 183 - 188
1 Mar 2002
Rogmark C Carlsson Ã… Johnell O Sernbo I

It remains a matter of debate whether displaced fractures of the neck of the femur should be treated by internal fixation or arthroplasty. We have compared the two methods with regard to complications, mortality and functional outcome. We studied 409 patients, aged 70 years and over, with subcapital fractures graded as Garden 3 or 4, in a two-year prospective multicentre study from 12 Swedish hospitals. They were randomised to internal fixation or arthroplasty. Patients who were mentally confused, bedridden or in a nursing-home were excluded from the survey. After two years the rate of failure was 43% in the internal fixation (IF) and 6% in the arthroplasty group (p < 0.001). In the IF group 36% had impaired walking and 6% had severe pain compared with 25% and 1.5%, respectively, in the arthroplasty group (both p < 0.05). There was no difference in mortality. With a high rate of failure and poor functional outcome after IF, we recommend primary arthroplasty for displaced fractures of the neck of the femur in patients over 70 years of age


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 97 - 101
1 Jan 2009
Clasper JC Rowley DI

We reviewed the clinical details and radiographs of 52 patients with ballistic fractures of the femur admitted to the International Committee of the Red Cross Hospital in Kenya (Lopiding), who had sustained injuries in neighbouring Sudan. In all cases there had been a significant delay in the initial surgery (> 24 hours), and all patients were managed without stabilisation of the fracture by internal or external fixation. Of the 52 patients, three required an amputation for persisting infection of the fracture site despite multiple debridements. A further patient was treated by an excision arthroplasty of the hip, but this was carried out at the initial operation as a part of the required debridement. All of the remaining 48 fractures healed. Four patients needed permanent shoe adaptation because of limb shortening of functional significance. Although we do not advocate delaying treatment or using traction instead of internal or external fixation, we have demonstrated that open femoral fractures can heal despite limited resources


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 400 - 404
1 Mar 2008
Johansson HR Skripitz R Aspenberg P

We have examined the deterioration of implant fixation after withdrawal of parathyroid hormone (PTH) in rats. First, the pull-out force for stainless-steel screws in the proximal tibia was measured at different times after withdrawal. The stimulatory effect of PTH on fixation was lost after 16 days. We then studied whether bisphosphonates could block this withdrawal effect. Mechanical and histomorphometric measurements were conducted for five weeks after implantation. Subcutaneous injections were given daily. Specimens treated with either PTH or saline during the first two weeks showed no difference in the mechanical or histological results (pull-out force 76 N vs 81 N; bone volume density 19% vs 20%). Treatment with PTH for two weeks followed by pamidronate almost doubled the pull-out force (152 N; p < 0.001) and the bone volume density (37%; ANOVA, p < 0.001). Pamidronate alone did not have this effect (89 N and 25%, respectively). Thus, the deterioration can be blocked by bisphosphonates. The clinical implications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 708 - 711
1 Nov 1988
Heywood A Learmonth I Thomas M

We describe a method of internal fixation for occipito-cervical fusion utilising a standard "small fragment" T-plate bent and fixed to the skull with three screws. The lower end of the plate is screwed and wired firmly to the spine of the axis. Of 14 patients so treated, 12 fused, one died and one failed to unite to the skull. Of eight with cord signs, seven remitted or improved and one died


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 565 - 567
1 Dec 1982
Howard C Davies R

Ten cases of a complication of Garden screw fixation of subcapital fracture, namely subtrochanteric fracture through the lower screw hole, are presented. Their possible aetiology, prevention and difficulties in management are discussed. It is recommended that, during the insertion of Garden screws, care should be taken to avoid multiple attempts at passing the guide wire. If subtrochanteric fracture occurs internal fixation with a nail plate or screw plate is advised. Ideally the nail or screw should be inserted along the track of one of the existing screws


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 858 - 861
1 Nov 1992
Casteleyn P Handelberg F Haentjens P

In a prospective trial, biodegradable polyglycolic acid rods were compared with Kirschner wires for fixation of wrist fractures (Frykman types I, II, V and VI). Fifteen patients were randomly assigned to each treatment group. There was no significant difference between the groups with regard to age, sex ratio and fracture type. Kapandji's pinning technique was used in all cases. There were no significant differences in the results obtained in both groups at final follow-up. At three months and six months the functional results of the Kirschner-wire group were, however, significantly better (p < 0.05), due to numerous transient complications from foreign-body reactions to the polyglycolic acid rods. The use of polyglycolic acid rods is therefore not recommended for the fixation of distal radial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 679 - 682
1 Jul 1991
Bostman O

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 277 - 283
1 Mar 1995
Choueka J Koval K Kummer F Crawford G Zuckerman J

We studied the biomechanical behaviour of three sliding fixation devices for trochanteric femoral fractures. These were a titanium alloy sideplate and lag screw, a titanium alloy sideplate and dome plunger with cement augmentation, and a stainless-steel sideplate and lag screw. We used 18 mildly osteoporotic cadaver femora, randomly assigned to one of the three fixation groups. Four displacement and two strain gauges were fixed to each specimen, and each femur was first tested intact (control), then as a two-part fracture and then as a four-part intertrochanteric fracture. A range of physiological loads was applied to determine load-bearing, load-sharing and head displacement. The four-part-fracture specimens were subsequently tested to failure to determine maximum fixation strengths and modes of failure. The dome-plunger group failed at a load 50% higher than that of the stainless-steel lag-screw group (p < 0.05) and at a load 20% higher than that of the titanium-alloy lag-screw group (NS). All 12 lag-screw specimens failed by cut-out through the femoral head or neck, but none of the dome-plunger group showed movement within the femoral head when tested to failure. Strain-gauge analysis showed that the dome plunger produced considerably less strain in the inferior neck and calcar region than either of the lag screws. Inferior displacement of the femoral head was greatest for the dome-plunger group, and was due to sliding of the plunger. The dome plunger with cement augmentation was able to support higher loads and did not fail by cut-out through the femoral head.(ABSTRACT TRUNCATED AT 250 WORDS)


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 357 - 366
1 May 1994
Malcolm G Ransford A Crockard H

We performed posterior fixation with a Hartshill-Ransford contoured loop in 43 patients with instability at the craniocervical junction. No external bracing was used. Fifteen patients had congenital malformations, ten had tumours, seven had 'bone-softening' conditions (such as osteogenesis imperfecta), five had suffered complicated fractures, three had occipito-C1-C2 hypermobility due to lax ligaments and three had severe degenerative spondylosis with pseudotumours of the transverse ligament. Twenty-nine patients had transoral decompression of the cord before fixation. In most cases, cancellous bone grafts taken from the iliac crest were used to induce fusion; in nine very ill patients, no bone graft was used. In the whole series there was no instance of construct failure, broken wire or laminar fracture. The best results were achieved in patients with tumours or bone-softening conditions. No patient with normal neurology deteriorated after surgery but seven had worse neurological deficits after operation than before. Neck stiffness caused half the patients to change their lifestyle


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 312 - 315
1 May 1983
Tayton K Bradley J

Test results on carbon-fibre-reinforced plastic plates are presented, all of which had been used as semi-rigid fixation in a series of fractures of the middle third of the human tibia. Symptoms of pain experienced by the patients were found to be related to the stiffness of the plates and it is suggested that a stiffness of 2.0 newton-metres per degree is most suitable for this type of fixation of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 292 - 296
1 Mar 1992
Plaga B Royster R Donigian A Wright G Caskey P

We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 484 - 489
1 May 1995
Won C Hearn T Tile M

Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial stability