In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p <
0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p <
0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantly reduced (p <
0.001). Our study indicates that the increase in the intervertebral disc height after disc replacement changes the geometry at the facet joints. This may have clinical relevance.
One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p >
0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.
We studied the bone mineral density (BMD) and
the bone mineral content (BMC) of the proximal tibia in patients with
a well-functioning uncemented Oxford medial compartment arthroplasty
using the Lunar iDXA bone densitometer. Our hypothesis was that
there would be decreased BMD and BMC adjacent to the tibial base
plate and increased BMD and BMC at the tip of the keel. There were 79 consecutive patients (33 men, 46 women) with a
mean age of 65 years (44 to 84) with a minimum two-year follow-up
(mean 2.6 years (2.0 to 5.0)) after unilateral arthroplasty, who
were scanned using a validated standard protocol where seven regions
of interest (ROI) were examined and compared with the contralateral
normal knee. All had well-functioning knees with a mean Oxford knee
score of 43 (14 to 48) and mean Knee Society function score of 90
(20 to 100), showing a correlation with the increasing scores and
higher BMC and BMD values in ROI 2 in the non-implanted knee relative
to the implanted knee (p = 0.013 and p = 0.015, respectively). The absolute and percentage changes in BMD and BMC were decreased
in all ROIs in the implanted knee compared with the non-implanted
knee, but this did not reach statistical significance. Bone loss
was markedly less than reported losses with total knee replacement. There was no significant association with side, although there
was a tendency for the BMC to decrease with age in men. The BMC
was less in the implanted side relative to the non-implanted side
in men compared with women in ROI 2 (p = 0.027), ROI 3 (p = 0.049)
and ROI 4 (p = 0.029). The uncemented Oxford medial compartment arthroplasty appears
to allow relative preservation of the BMC and BMD of the proximal
tibia, suggesting that the implant acts more physiologically than
total knee replacement. Peri-prosthetic bone loss is an important
factor in assessing long-term implant stability and survival, and
the results of this study are encouraging for the long-term outcome
of this arthroplasty. Cite this article:
The aim of this study was to determine the effect
of a Galeazzi fracture on the strength of pronation and supination at
a mean of two years after surgical treatment. The strength of pronation
and supination was measured in varying rotational positions of the
forearm of ten male patients (mean age 38.9 years (21 to 64)) who
had undergone plate fixation for a Galeazzi fracture. The stability
of the distal radioulnar joint was assessed, and a clinical assessment using
the quick-Disabilities of the Arm Shoulder and Hand (quickDASH)
questionnaire and patient-related wrist examination (PRWE) scores
was undertaken. In addition, the strength of pronation and supination
was measured in a male control group of 42 healthy volunteers (mean
age 21.8 years (18 to 37)). The mean absolute loss of strength of supination in the injured
compared with the non-injured arm throughout all ranges of forearm
rotation was 16.1 kg ( Loss of strength of pronation (27.2%), and of supination (12.5%)
in particular, after a Galeazzi fracture is associated with worse
clinical scores, highlighting the importance of supination of the
forearm in function of the upper limb. Cite this article:
Distal femoral physeal fractures in children have a high incidence of physeal arrest, occurring in a mean of 40% of cases. The underlying nature of the distal femoral physis may be the primary cause, but other factors have been postulated to contribute to the formation of a physeal bar. The purpose of this study was to assess the significance of contributing factors to physeal bar formation, in particular the use of percutaneous pins across the physis. We reviewed 55 patients with a median age of ten years (3 to 13), who had sustained displaced distal femoral physeal fractures. Most (40 of 55) were treated with percutaneous pinning after reduction, four were treated with screws and 11 with plaster. A total of 40 patients were assessed clinically and radiologically after skeletal maturity or at the time of formation of a bar. The remaining 15 were followed up for a minimum of two years. Formation of a physeal bar occurred in 12 (21.8%) patients, with the rate rising to 30.6% in patients with high-energy injuries compared with 5.3% in those with low-energy injuries. There was a significant trend for physeal arrest according to increasing severity using the Salter-Harris classification. Percutaneous smooth pins across the physis were not statistically associated with growth arrest.
The results of treatment of Lisfranc injuries are often unsatisfactory. This retrospective study investigated 46 patients with isolated Lisfranc injuries at a minimum of two years after surgery. Thirteen patients had a poor outcome and had to change employment, or were unable to find work as a result of this injury. The presence of a compensation claim (p = 0.02) and a delay in diagnosis of more than six months were associated with a poor outcome (p = 0.01). There was no association between poor functional outcome and age, gender, mechanism of injury or previous occupation. This study may have medico-legal implications on reporting the prognosis for such injuries, and highlights the importance of prompt diagnosis and treatment.
We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year), whereas those for the 22 and 26 mm heads were relatively low (0.090 and 0.098 mm/year, respectively). Moreover, the surface roughness data of retrieved femoral heads clearly showed maintenance of an excellent surface finish of the current alumina. We conclude that the alumina ceramic femoral heads currently used are associated with a reduced rate of polyethylene wear.
Transarticular screw fixation with autograft
is an established procedure for the surgical treatment of atlantoaxial instability.
Removal of the posterior arch of C1 may affect the rate of fusion.
This study assessed the rate of atlantoaxial fusion using transarticular
screws with or without removal of the posterior arch of C1. We reviewed
30 consecutive patients who underwent atlantoaxial fusion with a
minimum follow-up of two years. In 25 patients (group A) the posterior
arch of C1 was not excised (group A) and in five it was (group B).
Fusion was assessed on static and dynamic radiographs. In selected
patients CT imaging was also used to assess fusion and the position
of the screws. There were 15 men and 15Â women with a mean age of
51.2 years (23 to 77) and a mean follow-up of 7.7 years (2 to 11.6).
Stable union with a solid fusion or a stable fibrous union was achieved
in 29Â patients (97%). In Group A, 20 patients (80%) achieved a solid
fusion, four (16%) a stable fibrous union and one (4%) a nonunion.
In Group B, stable union was achieved in all patients, three having
a solid fusion and two a stable fibrous union. There was no statistically
significant difference between the status of fusion in the two groups.
Complications were noted in 12 patients (40%); these were mainly
related to the screws, and included malpositioning and breakage.
The presence of an intact or removed posterior arch of C1 did not
affect the rate of fusion in patients with atlantoaxial instability
undergoing C1/C2 fusion using transarticular screws and autograft. Cite this article:
The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes. Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60° of flexion. At flexion of 60° or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear.
This study investigated the quality and quantity of healing of a bone defect following intramedullary reaming undertaken by two fundamentally different systems; conventional, using non-irrigated, multiple passes; or suction/irrigation, using one pass. The result of a measured re-implantation of the product of reaming was examined in one additional group. We used 24 Swiss mountain sheep with a mean tibial medullary canal diameter between 8 mm and 9 mm. An 8 mm ‘napkin ring’ defect was created at the mid-diaphysis. The wound was either surgically closed or occluded. The medullary cavity was then reamed to 11 mm. The Reamer/Irrigator/Aspirator (RIA) System was used for the reaming procedure in groups A (RIA and autofilling) and B (RIA, collected reamings filled up), whereas reaming in group C (Synream and autofilling) was performed with the Synream System. The defect was allowed to auto-fill with reamings in groups A and C, but in group B, the defect was surgically filled with collected reamings. The tibia was then stabilised with a solid locking Unreamed Humerus Nail (UHN), 9.5 mm in diameter. The animals were killed after six weeks. After the implants were removed, measurements were taken to assess the stiffness, strength and callus formation at the site of the defect. There was no significant difference between healing after conventional reaming or suction/irrigation reaming. A significant improvement in the quality of the callus was demonstrated by surgically placing captured reamings into the defect using a graft harvesting system attached to the aspirator device. This was confirmed by biomechanical testing of stiffness and strength. This study suggests it could be beneficial to fill cortical defects with reaming particles in clinical practice, if feasible.
Using a dynamic biomechanical model of malunion of the shoulder, we have determined the change in deltoid force required for abduction with various combinations of superior and posterior displacement of fractures of the greater tuberosity of the humerus. We tested eight fresh human cadaver shoulders in a dynamic shoulder-testing apparatus during cycles of glenohumeral abduction from 0° to 90°. The greater tuberosities were osteotomised and stabilised to represent malunion with combinations of superior and posterior displacements of 1 cm and less. The peak force was measured for each displacement in each specimen and statistically compared with values of no displacement using a repeated-measures analysis of variance. The abduction force was significantly increased by 16% (p = 0.006) and 27% (p = 0.0001) by superior displacements of 0.5 cm and 1 cm, respectively, while combined superior and posterior displacement of 1 cm gave an increase in force of 29% (p = 0.001). While treatment criteria for acceptable residual displacement of the greater tuberosity are widely used, there is little information on the direct biomechanical effects of displacement on shoulder mechanics. Although the results of conservative treatment are influenced by a number of factors, including associated injuries, rehabilitation and the pre-existing function of the shoulder, our data suggest that small amounts of residual displacement may alter the balance of forces required to elevate the arm at the glenohumeral joint.
We have studied the beneficial effects of a hydroxyapatite (HA) coating on the prevention of the migration of wear debris along the implant-bone interface. We implanted a loaded HA-coated implant and a non-coated grit-blasted titanium alloy (Ti) implant in each distal femoral condyle of eight Labrador dogs. The test implant was surrounded by a gap communicating with the joint space and allowing access of joint fluid to the implant-bone interface. We injected polyethylene (PE) particles into the right knee three weeks after surgery and repeated this weekly for the following five weeks. The left knee received sham injections. The animals were killed eight weeks after surgery. Specimens from the implant-bone interface were examined under plain and polarised light. Only a few particles were found around HA-coated implants, but around Ti implants there was a large amount of particles. HA-coated implants had approximately 35% bone ingrowth, whereas Ti implants had virtually no bone ingrowth and were surrounded by a fibrous membrane. Our findings suggest that HA coating of implants is able to inhibit peri-implant migration of PE particles by creating a seal of tightly-bonded bone on the surface of the implant.
The purpose of this anatomical study was to explore the morphological variations of the semitendinosus and gracilis tendons in length and cross-section and the statistical relationship between length, cross-section, and body height. We studied the legs of 93 humans in 136 cadavers. In 43 specimens (46.2%) it was possible to harvest the tendons from both legs. We found considerable differences in the length and cross-section of the semitendinosus and the gracilis tendons with a significant correlation between the two. A correlation between the length of the femur, reflecting height, and the length of the tendons was only observed in specimens harvested from women. The reason for this gender difference was unclear. Additionally, there was a correlation between the cross-sectional area of the tendons and the length of the femur. Surgeons should be aware of the possibility of encountering insufficient length of tendon when undertaking reconstructive surgery as a result of anatomical variations between patients.
Bone tumours may recur locally even after wide surgical excision and systemic chemotherapy. Local control of growth may be accomplished by the addition of cytostatic drugs such as methotrexate (MTX) to bone cement used to fill the defect after surgery and to stabilise the reconstructive prosthesis. We have studied the elution kinetics of MTX and its solvent N-methyl-pyrrolidone (NMP) from bone cement and their biological activities in five cell lines of osteosarcoma and in osteoblasts, and compared them with the effects of the parent compounds alone and in combination. Our findings show that MTX is released continuously over months at concentrations highly cytotoxic to osteosarcoma cells and suggest that the impregnated bone cement would be effective in the long term. Proliferating osteoblasts, however, were much less sensitive towards MTX. The dose-response relationship for NMP and experiments with MTX/NMP-mixtures show that the eluted concentrations of solvent are not toxic and do not influence the effects of MTX. We suggest that bone cement containing MTX dissolved in NMP releases the drug in a suitable and effective way and may be of value in the treatment of bone tumours.
Rat patellae were preincubated with culture medium M199 for one hour and then with either fresh culture medium or Ringer's solution, Ringer lactate, Ringer glucose, normal saline or Betadine for another hour. The rate of proteoglycan synthesis in the articular cartilage was then measured by uptake of 35SO4 for the next 16 hours. Cartilage metabolism was inhibited by all of the solutions even after a recovery time of 16 hours. The inhibition was by 5% for Ringer's solution, 10% for Ringer glucose (p <
0.01), 20% for saline and Ringer lactate (p <
0.001) and 55% for Betadine (p <
0.001). Ringer's solution is therefore the best choice for joint irrigation during arthroscopy or other procedures.
Seven subjects with normal joints were tested for active and passive position sense of ankle inversion, peroneal reflex reaction time to sudden ankle inversion, and postural stability during single-leg stance. The tests were performed before and after regional block of the ankle and foot with local anaesthetic. Passive position sense, assessed with the muscles relaxed, was greatly impaired by anaesthesia but active position sense, with the calf muscles activated, was preserved, and the peroneal reaction time to sudden ankle inversion was not altered. The magnitude of postural sway during single-leg stance was also unchanged by anaesthesia of the ankle and foot. The results suggest that the afferent input from intact lateral ankle ligaments is important in sensing correct placement of the foot at heel-strike, but that this input can be replaced by afferent information from active calf muscles. Afferent input from these muscles seems also to be responsible for dynamic ankle protection against sudden ankle inversion and is adequate to allow stable single-leg stance.
We used 15 pairs of femora from fresh human cadavers to study the effects of the size and location of the entry hole for an intramedullary nail on the strength of the femur. Right femora were used as controls. Left femora in group 1 had a 10 mm entry hole in the 'ideal' location in the piriformis fossa. Group 2 had a 14 mm entry hole in the same position and group 3 had a 14 mm entry hole anterior to this on the superior aspect of the femoral neck. Femora were equipped with strain gauges and loaded to failure in compression. There was reduced stiffness and load to failure in group 3 specimens, suggesting that the location of the hole was more important than its size.