Advertisement for orthosearch.org.uk
Results 241 - 260 of 1022
Results per page:
Bone & Joint Research
Vol. 8, Issue 10 | Pages 495 - 501
1 Oct 2019
Hampp EL Sodhi N Scholl L Deren ME Yenna Z Westrich G Mont MA

Objectives

The use of the haptically bounded saw blades in robotic-assisted total knee arthroplasty (RTKA) can potentially help to limit surrounding soft-tissue injuries. However, there are limited data characterizing these injuries for cruciate-retaining (CR) TKA with the use of this technique. The objective of this cadaver study was to compare the extent of soft-tissue damage sustained through a robotic-assisted, haptically guided TKA (RATKA) versus a manual TKA (MTKA) approach.

Methods

A total of 12 fresh-frozen pelvis-to-toe cadaver specimens were included. Four surgeons each prepared three RATKA and three MTKA specimens for cruciate-retaining TKAs. A RATKA was performed on one knee and a MTKA on the other. Postoperatively, two additional surgeons assessed and graded damage to 14 key anatomical structures in a blinded manner. Kruskal–Wallis hypothesis tests were performed to assess statistical differences in soft-tissue damage between RATKA and MTKA cases.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims

The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires.

Patients and Methods

This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 911 - 915
1 Jul 2005
van Hellemondt GG Sonneveld H Schreuder MHE Kooijman MAP de Kleuver M

We report the long-term results of 51 pelvic osteotomies in 43 patients with a mean follow-up of 15 years (13 to 20). The mean age of the patients was 28 years (14 to 46). At review three patients were lost to follow-up, and six had received a total hip arthroplasty. Of 48 hips, 42 (88%) were preserved, with good to excellent clinical results in 27 (64%). Pre-operatively, 41 (80%) of the treated hips had shown no sign of osteoarthritis. Thirty-one (65%) hips showed no progression of osteoarthritis after follow-up for 15 years. Significant negative factors for good long-term results were the presence of osteoarthritic changes and a fair or poor clinical score pre-operatively. Pelvic reorientation osteotomy for symptomatic hip dysplasia can give satisfactory and reproducible long-term clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 341 - 344
1 Mar 2006
Tanaka N Sakahashi H Ishii S Kudo H

The purpose of this study was to assess the long-term results (more than ten years) of two types of cemented ulnar component with type-5 Kudo total elbow arthroplasty in a consecutive series of 56 patients (60 elbows) with rheumatoid arthritis, and to compare the results in elbows above and below a Larsen grade IV. There was no radiolucency around the humeral component. Patients in whom a metal-backed ulnar component and a porous-coated stem were used had better clinical results and significantly less progression of radiolucent line formation around the ulnar component. They also had a significantly better long-term survival than patients with an all-polyethylene ulnar component. The clinical results of arthroplasty using all-polyethylene ulnar components were inferior, regardless of the degree of joint destruction. We conclude that the type-5 Kudo total elbow arthroplasty with cementless fixation of the porous-coated humeral component and cemented fixation of a metal-backed ulnar component is acceptable and well-tolerated by rheumatoid patients


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 56 - 63
1 Jan 2015
Abane L Anract P Boisgard S Descamps S Courpied JP Hamadouche M

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI). . The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip–knee–ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m. 2. (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG. . The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment. . Cite this article: Bone Joint J 2015;97-B:56–63


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 203 - 205
1 Feb 2006
Krishnan SP Skinner JA Carrington RWJ Flanagan AM Briggs TWR Bentley G

We prospectively studied the clinical, arthroscopic and histological results of collagen-covered autologous chondrocyte implantation (ACI-C) in patients with symptomatic osteochondritis dissecans of the knee. The study included 37 patients who were evaluated at a mean follow-up of 4.08 years. Clinical results showed a mean improvement in the modified Cincinnati score from 46.1 to 68.4. Excellent and good clinical results were seen in 82.1% of those with juvenile-onset osteochondritis dissecans but in only 44.4% of those with adult-onset disease. Arthroscopy at one year revealed International Cartilage Repair Society grades of 1 or 2 in 21 of 24 patients (87.5%). Of 23 biopsies, 11 (47.8%) showed either a hyaline-like or a mixture of hyaline-like and fibrocartilage, 12 (52.2%) showed fibrocartilage. The age at the time of ACI-C determined the clinical outcome for juvenile-onset disease (p = 0.05), whereas the size of the defect was the major determinant of outcome in adult-onset disease (p = 0.01)


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1151 - 1159
1 Sep 2019
Oike N Kawashima H Ogose A Hatano H Ariizumi T Kaidu M Aoyama H Endo N

Aims

We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts

Patients and Methods

This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1474 - 1479
1 Nov 2006
Magnan B Bortolazzi R Marangon A Marino M Dall’Oca C Bartolozzi P

A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders’ type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler’s angle was 6.98° (5.95° to 19.86°), whereas after surgery the mean value was 21.94° (12.58° to 31.30°) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Zhang B Sun H Zhan Y He Q Zhu Y Wang Y Luo C

Objectives

CT-based three-column classification (TCC) has been widely used in the treatment of tibial plateau fractures (TPFs). In its updated version (updated three-column concept, uTCC), a fracture morphology-based injury mechanism was proposed for effective treatment guidance. In this study, the injury mechanism of TPFs is further explained, and its inter- and intraobserver reliability is evaluated to perfect the uTCC.

Methods

The radiological images of 90 consecutive TPF patients were collected. A total of 47 men (52.2%) and 43 women (47.8%) with a mean age of 49.8 years (sd 12.4; 17 to 77) were enrolled in our study. Among them, 57 fractures were on the left side (63.3%) and 33 were on the right side (36.7%); no bilateral fracture existed. Four observers were chosen to classify or estimate independently these randomized cases according to the Schatzker classification, TCC, and injury mechanism. With two rounds of evaluation, the kappa values were calculated to estimate the inter- and intrareliability.


Bone & Joint Research
Vol. 8, Issue 8 | Pages 387 - 396
1 Aug 2019
Alt V Rupp M Lemberger K Bechert T Konradt T Steinrücke P Schnettler R Söder S Ascherl R

Objectives

Preclinical data showed poly(methyl methacrylate) (PMMA) loaded with microsilver to be effective against a variety of bacteria. The purpose of this study was to assess patient safety of PMMA spacers with microsilver in prosthetic hip infections in a prospective cohort study.

Methods

A total of 12 patients with prosthetic hip infections were included for a three-stage revision procedure. All patients received either a gentamicin-PMMA spacer (80 g to 160 g PMMA depending on hip joint dimension) with additional loading of 1% (w/w) of microsilver (0.8 g to 1.6 g per spacer) at surgery 1 followed by a gentamicin-PMMA spacer without microsilver at surgery 2 or vice versa. Implantation of the revision prosthesis was carried out at surgery 3.


Aims. To evaluate the hypothesis that failed osteosynthesis of periprosthetic Vancouver type B1 fractures can be treated successfully with stem revision using a transfemoral approach and a cementless, modular, tapered revision stem with reproducible rates of fracture healing, stability of the revision stem, and clinically good results. Patients and Methods. A total of 14 patients (11 women, three men) with a mean age of 72.4 years (65 to 90) undergoing revision hip arthroplasty after failed osteosynthesis of periprosthetic fractures of Vancouver type B1 were treated using a transfemoral approach to remove the well-fixed stem before insertion of a modular, fluted titanium stem which obtained distal fixation. These patients were clinically and radiologically followed up for a mean 52.2 months (24 to 144). Results. After a mean of 15.5 weeks (standard deviation (. sd. ) 5.7) all fractures had healed. No stems subsided and bony-ingrowth fixation had occurred according to the classification of Engh et al. The mean Harris Hip Score increased from a pre-operative score of 22.2 points (. sd. 9.7) to 81.5 points (. sd. 16.8) 24 months post-operatively. All hips had obtained an excellent result according to the classification of Beals and Tower. Conclusions. The technique described here for stem revision provides reproducibly good results in the treatment of failed osteosynthesis for Vancouver types B1 periprosthetic fractures of the hip. Cite this article: Bone Joint J 2017;99-B(4 Supple B):11–16


Bone & Joint 360
Vol. 8, Issue 4 | Pages 23 - 25
1 Aug 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1645 - 1649
1 Dec 2007
Joo SY Park KB Kim BR Park HW Kim HW

We describe our experience with the ‘four-in-one’ procedure for habitual dislocation of the patella in five children (six knees). All the patients presented with severe generalised ligamentous laxity and aplasia of the trochlear groove. All had a lateral release, proximal ‘tube’ realignment of the patella, semitendinosus tenodesis and transfer of the patellar tendon. The mean age at the time of the operation was 6.1 years (4.9 to 6.9), and the patients were followed up for a mean of 54.5 months (31 to 66). The clinical results were evaluated using the Kujala score. There has been no recurrence of dislocation. All the patients have returned to full activities and the parents and children were satisfied with the clinical results. The mean Kujala score was 95.3 (88 to 98). Two patients had marginal skin necrosis which healed after debridement and secondary closure. These early results in this small group have shown that the ‘four-in-one’ procedure is effective in the treatment of obligatory dislocation of the patella in children with severe ligamentous laxity and trochlear aplasia


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1582 - 1582
1 Nov 2013
Haddad FS

Kazi HA, Perera JR, Gillott E, Carroll FA, Briggs TW. A prospective study of a ceramic-on-metal bearing in total hip arthroplasty: Clinical results, metal ion levels and chromosome analysis at two years. Bone Joint J 2013;95-B:1040-1044


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1392 - 1395
1 Oct 2013
Matsumoto T Imagama S Ito Z Imai R Kamada T Shimoyama Y Matsuyama Y Ishiguro N

The main form of treatment of a chordoma of the mobile spine is total en bloc spondylectomy (TES), but the clinical results are not satisfactory. Stand-alone carbon ion radiotherapy (CIRT) for bone and soft-tissue sarcomas has recently been reported to have a high rate of local control with a low rate of local recurrence. . We report two patients who underwent TES after CIRT for treating a chordoma in the lumbar spine with good medium-term outcomes. At operation, there remained histological evidence of viable tumour cells in both cases. After the combination use of TES following CIRT, neither patient showed signs of recurrence at the follow-up examination. These two cases suggest that CIRT should be combined with total spondylectomy in the treatment of chordoma of the mobile spine. Cite this article: Bone Joint J 2013;95-B:1392–5


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 907 - 913
1 Jul 2014
Dossett HG Estrada NA Swartz GJ LeFevre GW Kwasman BG

We have previously reported the short-term radiological results of a randomised controlled trial comparing kinematically aligned total knee replacement (TKR) and mechanically aligned TKR, along with early pain and function scores. In this study we report the two-year clinical results from this trial. A total of 88 patients (88 knees) were randomly allocated to undergo either kinematically aligned TKR using patient-specific guides, or mechanically aligned TKR using conventional instruments. They were analysed on an intention-to-treat basis. The patients and the clinical evaluator were blinded to the method of alignment. At a minimum of two years, all outcomes were better for the kinematically aligned group, as determined by the mean Oxford knee score (40 (15 to 48) versus 33 (13 to 48); p = 0.005), the mean Western Ontario McMaster Universities Arthritis index (WOMAC) (15 (0 to 63) versus 26 (0 to 73); p = 0.005), mean combined Knee Society score (160 (93 to 200) versus 137 (64 to 200); p= 0.005) and mean flexion of 121° (100 to 150) versus 113° (80 to 130) (p = 0.002). The odds ratio of having a pain-free knee at two years with the kinematically aligned technique (Oxford and WOMAC pain scores) was 3.2 (p = 0.020) and 4.9 (p = 0.001), respectively, compared with the mechanically aligned technique. Patients in the kinematically aligned group walked a mean of 50 feet further in hospital prior to discharge compared with the mechanically aligned group (p = 0.044). In this study, the use of a kinematic alignment technique performed with patient-specific guides provided better pain relief and restored better function and range of movement than the mechanical alignment technique performed with conventional instruments. Cite this article: Bone Joint J 2014;96-B:907–13


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 787 - 792
1 Jul 2019
Goto K Kuroda Y Kawai T Kawanabe K Matsuda S

Aims

In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC.

Patients and Methods

A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 817 - 823
1 Jul 2019
Vigdorchik J Eftekhary N Elbuluk A Abdel MP Buckland AJ Schwarzkopf RS Jerabek SA Mayman DJ

Aims

While previously underappreciated, factors related to the spine contribute substantially to the risk of dislocation following total hip arthroplasty (THA). These factors must be taken into consideration during preoperative planning for revision THA due to recurrent instability. We developed a protocol to assess the functional position of the spine, the significance of these findings, and how to address different pathologies at the time of revision THA.

Patients and Methods

Prospectively collected data on 111 patients undergoing revision THA for recurrent instability from January 2014 to January 2017 at two institutions were included (protocol group) and matched 1:1 to 111 revisions specifically performed for instability not using this protocol (control group). Mean follow-up was 2.8 years. Protocol patients underwent standardized preoperative imaging including supine and standing anteroposterior (AP) pelvis and lateral radiographs. Each case was scored according to the Hip-Spine Classification in Revision THA.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 793 - 799
1 Jul 2019
Ugland TO Haugeberg G Svenningsen S Ugland SH Berg ØH Pripp AH Nordsletten L

Aims

The aim of this randomized trial was to compare the functional outcome of two different surgical approaches to the hip in patients with a femoral neck fracture treated with a hemiarthroplasty.

Patients and Methods

A total of 150 patients who were treated between February 2014 and July 2017 were included. Patients were allocated to undergo hemiarthroplasty using either an anterolateral or a direct lateral approach, and were followed for 12 months. The mean age of the patients was 81 years (69 to 90), and 109 were women (73%). Functional outcome measures, assessed by a physiotherapist blinded to allocation, and patient-reported outcome measures (PROMs) were collected postoperatively at three and 12 months.