Advertisement for orthosearch.org.uk
Results 2561 - 2580 of 4652
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 765 - 770
1 Jun 2006
Lee JS Suh KT

There are few reports on the treatment of pyogenic lumbar spondylodiscitis through the posterior approach using a single incision. Between October 1999 and March 2003 we operated on 18 patients with pyogenic lumbar spondylodiscitis. All underwent posterior lumbar interbody fusion using an autogenous bone graft from the iliac crest and pedicle screws via a posterior approach. The clinical outcome was assessed using the Frankel neurological classification and the criteria of Kirkaldy-Willis. Under the Frankel classification, two patients improved by two grades (C to E), 11 by one grade, and five showed no change. The Kirkaldy-Willis functional outcome was excellent in five patients, good in ten and fair in three. Bony union was confirmed six months after surgery in 17 patients, but in one patient this was not achieved until two years after operation. The mean lordotic angle before operation was 20° (−2° to 42°) and the mean lordotic angle at the final follow-up was 32.5° (17° to 44°). Two patients had a superficial wound infection and two a transient root injury. Posterior lumbar interbody fusion with an autogenous iliac crest bone graft and pedicle screw fixation via a posterior approach can provide satisfactory results in pyogenic spondylodiscitis


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1184 - 1187
1 Sep 2007
Rispoli DM Sperling JW Athwal GS Schleck CD Cofield RH

We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed. The level of pain was significantly decreased (t-test, p < 0.001) but five patients continued to have moderate to severe pain. The mean active elevation was 70° (0° to 150°) postoperatively and represented an improvement from 39° (0° to 140°) (t-test, p = 0.003), but internal and external rotation were hardly changed. The mean number of positive answers on the 12-question Simple Shoulder Test was 3.1 (0 to 12) but the shoulder was generally comfortable when the arm was positioned at rest by the side. The mean post-operative American Shoulder and Elbow Surgeon’s score was 36 (8 to 73). Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1000 - 1004
1 Aug 2008
Wraighte PJ Howard PW

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification. The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively. Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p < 0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97)


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1596 - 1602
1 Dec 2017
Dunbar MJ Laende EK Collopy D Richardson CG

Aims

Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation.

Patients and Methods

A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1611 - 1617
1 Dec 2017
Frisch NB Courtney PM Darrith B Della Valle CJ

Aims

The purpose of this study is to determine if higher volume hospitals have lower costs in revision hip and knee arthroplasty.

Materials and Methods

We questioned the Centres for Medicare and Medicaid Services (CMS) Inpatient Charge Data and identified 789 hospitals performing a total of 29 580 revision arthroplasties in 2014. Centres were dichotomised into high-volume (performing over 50 revision cases per year) and low-volume. Mean total hospital-specific charges and inpatient payments were obtained from the database and stratified based on Diagnosis Related Group (DRG) codes. Patient satisfaction scores were obtained from the multiyear CMS Hospital Compare database.


Aims

The aim of this study was to examine the efficacy and safety of multiple boluses of intravenous (IV) tranexamic acid (TXA) on the hidden blood loss (HBL) and inflammatory response following primary total hip arthroplasty (THA).

Patients and Methods

A total of 150 patients were allocated randomly to receive a single bolus of 20 mg/kg IV TXA before the incision (group A), a single bolus followed by a second bolus of 1 g IV-TXA three hours later (group B) or a single bolus followed by two boluses of 1 g IV-TXA three and six hours later (group C). All patients were treated using a standard peri-operative enhanced recovery protocol. Primary outcomes were HBL and the level of haemoglobin (Hb) as well as the levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers of inflammation. Secondary outcomes included the length of stay in hospital and the incidence of venous thromboembolism (VTE).


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1561 - 1570
1 Dec 2017
Laumonerie P Reina N Kerezoudis P Declaux S Tibbo ME Bonnevialle N Mansat P

Aims

The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation.

Materials and Methods

Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1658 - 1664
1 Dec 2017
Ahmad A Subramanian T Panteliadis P Wilson-Macdonald J Rothenfluh DA Nnadi C

Aims

Magnetically controlled growing rods (MCGRs) allow non-invasive correction of the spinal deformity in the treatment of early-onset scoliosis. Conventional growing rod systems (CGRS) need repeated surgical distractions: these are associated with the effect of the ‘law of diminishing returns’.

The primary aim of this study was to quantify this effect in MCGRs over sequential distractions.

Patients and Methods

A total of 35 patients with a maximum follow-up of 57 months were included in the study. There were 17 boys and 18 girls with a mean age of 7.4 years (2 to 14). True Distraction (TD) was determined by measuring the expansion gap on fluoroscopy. This was compared with Intended Distraction (ID) and expressed as the ‘T/I’ ratio. The T/I ratio and the Cobb angle were calculated at several time points during follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation. Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief


Bone & Joint Research
Vol. 6, Issue 9 | Pages 535 - 541
1 Sep 2017
Zan P Mol MO Yao JJ Fan L Yang D Liu K Li G

Objectives

The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA.

Methods

A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 904 - 910
1 Jul 2007
Kim Y Kim D Kim J

We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 928 - 932
1 Jul 2006
Patil S Montgomery R

We reviewed 78 femoral and tibial nonunions treated between January 1992 and December 2003. Of these, we classified 41 in 40 patients as complex cases because of infection (22), bone loss (6) or failed previous surgery (13). The complex cases were all treated with Ilizarov frames. At a mean time of 14.1 months (4 to 38), 39 had healed successfully. Using the Association for the Study and Application of the Methods of Ilizarov scoring system we obtained 17 excellent, 14 good, four fair and six poor bone results. The functional results were excellent in 14 patients, good in 14, fair in two and poor in two. A total of six patients were lost to follow-up and two had amputations so were not evaluated for final functional assessment. All but two patients were very satisfied with the results. The average cost of treatment to the treating hospital was approximately £30 000 per patient. We suggest that early referral to a tertiary centre could reduce the morbidity and prolonged time off work for these patients. The results justify the expense, but the National Health Service needs to make financial provision for the reconstruction of this type of complex nonunion


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 925 - 927
1 Jul 2007
Jackson WFM Tryfonidis M Cooke PH Sharp RJ

Correction of valgus deformity of the hindfoot using a medial approach for a triple fusion has only recently been described for patients with tight lateral soft tissues which would be compromised using the traditional lateral approach. We present a series of eight patients with fixed valgus deformity of the hindfoot who had correction by hindfoot fusion using this approach. In addition, we further extended the indications to allow concomitant ankle fusion. The medial approach allowed us to excise medial ulcers caused by the prominent medial bony structures, giving simultaneous correction of the deformity and successful internal fixation. We had no problems with primary wound healing and experienced no subsequent infection or wound breakdown. From a mean fixed valgus deformity of 58.8° (45° to 66°) pre-operatively, we achieved a mean post-operative valgus angulation of 13.6° (7° to 23°). All the feet were subsequently accommodated in shoes. The mean time to arthrodesis was 5.25 months (3 to 9). We therefore recommend the medial approach for the correction of severe fixed valgus hindfoot deformities


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1022 - 1025
1 Sep 2000
Minami A Kasashima T Iwasaki N Kato H Kaneda K

The results and complications of 104 vascularised fibular grafts in 102 patients are presented. Bony union was ultimately achieved in 97 patients, with primary union in 84 (84%). The mean time to union was 15.5 weeks (8 to 40). In 13 patients, primary union was achieved at one end of the fibula and secondary union at the other end. In these patients, the mean time to union was 31.1 weeks (24 to 40). Five patients failed to achieve union, with a resultant pseudarthrosis (3 patients) or amputation (2 patients). There were various complications. Immediate thrombosis occurred in 14 cases. In two of 23 patients with osteomyelitis, infection recurred at two and six months after surgery, respectively. Both patients had active osteomyelitis less than one month before the operation. Bony infection occurred in a patient with a synovial sarcoma of the forearm one year after surgery. In 15 patients, 19 fractures of the fibular graft occurred after bony union, all except one within one year after union. In patients in whom an external fixator had been used, fracture occurred soon after its removal. Union was difficult to achieve in cases of congenital pseudarthrosis of the tibia. Appropriate alignment of the fibular graft is an important factor in preventing stress fracture. The vascularised fibula should be protected during the first year after union. Postoperative complications at the donor site included transient palsy of the superficial peroneal nerve in three patients, contracture of flexor hallucis longus in two and valgus deformity of the ankle in three. Vascularised fibular grafts are useful in the reconstruction of massive bony defects. We believe that meticulous preoperative planning, including choosing which vessels to select in the recipient and the type of fixation devices to use, and care in the introduction of the vascularised fibula, can improve the results and prevent complications


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 1 - 1
1 Jan 2018
Greenwald AS


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 40 - 43
1 Jan 2006
Hutchinson JRM Parish EN Cross MJ

In a series of 1304 patients (1867 knees), the results of simultaneous and staged bilateral total knee arthroplasty were compared with each other and with unilateral total knee arthroplasty. The bilateral procedures had a significantly higher rate of complications than unilateral procedures, almost entirely because of thromboembolic problems. However, this did not correspond to an increase in mortality. If a bilateral procedure was indicated, then a simultaneous procedure had no increased risk over a staged procedure. There was no increase in cardiovascular complications, the rate of deep-vein thrombosis or pulmonary embolism or mortality. The rate of infection was lower with a bilateral procedure and the overall revision rate was less than 1% in all groups. The prosthesis functioned as well in all groups in the medium and longer term periods. We feel that simultaneous bilateral total knee arthroplasty is a safe and successful procedure when compared with a staged bilateral procedure. It also has the added benefit of single anaesthetic, reduced costs and decreased total recovery time when compared to a staged bilateral procedure. For these reasons it should be considered as an option in the presence of bilateral knee joint disease


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1499 - 1506
1 Nov 2008
Rammelt S Schneiders W Schikore H Holch M Heineck J Zwipp H

Fracture-dislocations of the tarsometatarsal (Lisfranc) joints are frequently overlooked or misdiagnosed at initial presentation. This is a comparative cohort study over a period of five years comparing primary open reduction and internal fixation in 22 patients (23 feet) with secondary corrective arthrodesis in 22 patients (22 feet) who presented with painful malunion at a mean of 22 months (1.5 to 45) after injury. In the first group primary treatment by open reduction and internal fixation for eight weeks with Kirschner-wires or screws was undertaken, in the second group treatment was by secondary corrective arthrodesis. There was one deep infection in the first group. In the delayed group there was one complete and one partial nonunion. In each group 20 patients were available for follow-up at a mean of 36 months (24 to 89) after operation. The mean American Orthopaedic Foot and Ankle Society midfoot score was 81.4 (62 to 100) after primary treatment and 71.8 (35 to 88) after corrective arthrodesis (t-test; p = 0.031). We conclude that primary treatment by open reduction and internal fixation of tarsometatarsal fracture-dislocations leads to improved functional results, earlier return to work and greater patient satisfaction than secondary corrective arthrodesis, which remains a useful salvage procedure providing significant relief of pain and improvement in function


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1125 - 1131
1 Sep 2017
Rickman M Varghese VD

In the time since Letournel popularised the surgical treatment of acetabular fractures, more than 25 years ago, there have been many changes within the field, related to patients, surgical technique, implants and post-operative care. However, the long-term outcomes appear largely unchanged. Does this represent stasis or have the advances been mitigated by other negative factors? In this article we have attempted to document the recent changes within the surgery of patients with a fracture involving the acetabulum, outline contemporary management, and identify the major problem areas where further research is most needed.

Cite this article: Bone Joint J 2017;99-B:1125–31


Bone & Joint 360
Vol. 6, Issue 4 | Pages 23 - 25
1 Aug 2017