We investigated the effects on fracture healing of two up-regulators of inducible nitric oxide synthase (iNOS) in a rat model of an open femoral osteotomy: tadalafil, a phosphodiesterase inhibitor, and the recently reported nutraceutical, COMB-4 (consisting of L-citrulline, Paullinia cupana, ginger and muira puama), given orally for either 14 or 42 days. Unilateral femoral osteotomies were created in 58 male rats and fixed with an intramedullary compression nail. Rats were treated daily either with vehicle, tadalafil or COMB-4. Biomechanical testing of the healed fracture was performed on day 42. The volume, mineral content and bone density of the callus were measured by quantitative CT on days 14 and 42. Expression of iNOS was measured by immunohistochemistry.Objectives
Materials and Methods
To investigate whether pre-operative functional mobility is a
determinant of delayed inpatient recovery of activities (IRoA) after
total knee arthroplasty (TKA) in three periods that coincided with
changes in the clinical pathway. All patients (n = 682, 73% women, mean age 70 years, standard
deviation 9) scheduled for TKA between 2009 and 2015 were pre-operatively
screened for functional mobility by the Timed-up-and-Go test (TUG)
and De Morton mobility index (DEMMI). The cut-off point for delayed
IRoA was set on the day that 70% of the patients were recovered,
according to the Modified Iowa Levels of Assistance Scale (mILAS)
(a 5-item activity scale). In a multivariable logistic regression
analysis, we added either the TUG or the DEMMI to a reference model
including established determinants.Aims
Patients and Methods
There are two techniques widely used to determine the rotational
alignment of the components in total knee arthroplasty (TKA); gap
balancing (GB) and measured resection (MR). Which technique is the
best remains controversial. We aimed to investigate this in a systematic
review and meta-analysis. In accordance with the methods of Cochrane, databases were searched
for all randomised controlled trials in the literature between January
1986 and June 2015 comparing radiographic and clinical outcomes
between the use of these two tecniques. Meta-analysis involved the
use of the Revman5.3 software provided by Cochrane collaboration.Aims
Materials and Methods
The aims of this retrospective study were to report the feasibility
of using 3D-printing technology for patients with a pelvic tumour
who underwent reconstruction. A total of 35 patients underwent resection of a pelvic tumour
and reconstruction using 3D-printed endoprostheses between September
2013 and December 2015. According to Enneking’s classification of
bone defects, there were three Type I lesions, 12 Type II+III lesions,
five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV
lesions and three type I+II+III+IV lesions. A total of three patients
underwent reconstruction using an iliac prosthesis, 12 using a standard
hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic
prosthesis.Aims
Patients and Methods
The aim of this study was to compare the Push Ortho Thumb Brace
CMC and a custom-made orthosis in the treatment of patients with
primary osteoarthritis of the carpometacarpal joint of the thumb.
Our outcome measures were pain scores, tests of hand function, patient
satisfaction and patient preference. A multicentre crossover randomised controlled trial was conducted
which included 63 patients (44 women) with primary osteoarthritis
of the carpometacarpal joint of the thumb. Of these, 59 patients
with a mean age of 60.1 years (standard deviation 8.2), completed
the study. Patients used both orthoses for two weeks with a two-week washout
period in-between. Pain was measured on a 10-cm visual analogue
scale. Hand function was assessed using the Jebsen Taylor Hand Function
test, Nine Hole Peg Test, key grip, pinch grip and Functional Index
for Hand Osteoarthritis. Patient preference was assessed using the
Dutch version of the Quebec User Evaluation of Satisfaction with
Assistive Technology score.Aims
Patients and Methods
Mesenchymal stem cells have the ability to differentiate into various cell types, and thus have emerged as promising alternatives to chondrocytes in cell-based cartilage repair methods. The aim of this experimental study was to investigate the effect of bone marrow derived mesenchymal stem cells combined with platelet rich fibrin on osteochondral defect repair and articular cartilage regeneration in a canine model. Osteochondral defects were created on the medial femoral condyles of 12 adult male mixed breed dogs. They were either treated with stem cells seeded on platelet rich fibrin or left empty. Macroscopic and histological evaluation of the repair tissue was conducted after four, 16 and 24 weeks using the International Cartilage Repair Society macroscopic and the O’Driscoll histological grading systems. Results were reported as mean and standard deviation (Objectives
Methods
All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05.Objectives
Materials and Methods
Vancomycin is commonly added to acrylic bone cement during revision
arthroplasty surgery. Proprietary cement preparations containing
vancomycin are available, but are significantly more expensive.
We investigated whether the elution of antibiotic from ‘home-made’
cement containing vancomycin was comparable with more expensive
commercially available vancomycin impregnated cement. A total of 18 cement discs containing either proprietary CopalG+V;
or ‘home-made’ CopalR+G with vancomycin added by hand, were made.
Each disc contained the same amount of antibiotic (0.5 g gentamycin,
2 g vancomycin) and was immersed in ammonium acetate buffer in a
sealed container. Fluid from each container was sampled at eight
time points over a two-week period. The concentrations of gentamicin
and vancomycin in the fluid were analysed using high performance
liquid chromatography mass spectrometry.Aims
Materials and Methods
The aim of this study was to compare the survivorship and radiographic
outcomes at ten-year follow-up of three prospective consecutive
series of patients each of which received a different design of
cementless femoral components for total hip arthroplasty (THA). In Cohort 1, 91 consecutive patients (100 hips) underwent THA
with a cementless porous-coated anatomic femoral stem (PCA) between
October 1983 and January 1986. In Cohort 2, 86 consecutive patients
(100 hips) underwent THA with an extensively porous-coated cementless
femoral stem (Prodigy) between June 1994 and October 1997. In Cohort
3, 88 consecutive patients (100 hips) underwent THA with a proximally
porous-coated triple-tapered cementless stem (Summit) between April
2002 and October 2003. All three groups underwent prospective clinical
and radiographic evaluation.Aims
Patients and Methods
The aim of this systematic review was to report the rate of dislocation
following the use of dual mobility (DM) acetabular components in
primary and revision total hip arthroplasty (THA). A systematic review of the literature according to the Preferred
Reporting Items for Systematic Reviews and Meta-analyses guidelines
was performed. A comprehensive search of Pubmed/Medline, Cochrane
Library and Embase (Scopus) was conducted for English articles between
January 1974 and March 2016 using various combinations of the keywords “dual
mobility”, “dual-mobility”, “tripolar”, “double-mobility”, “double
mobility”, “hip”, “cup”, “socket”. The following data were extracted
by two investigators independently: demographics, whether the operation
was a primary or revision THA, length of follow-up, the design of
the components, diameter of the femoral head, and type of fixation
of the acetabular component.Aims
Materials and Methods
The aim of this to study was to compare the previously unreported
long-term survival outcome of the Oxford medial unicompartmental
knee arthroplasty (UKA) performed by trainee surgeons and consultants. We therefore identified a previously unreported cohort of 1084
knees in 947 patients who had a UKA inserted for anteromedial knee
arthritis by consultants and surgeons in training, at a tertiary
arthroplasty centre and performed survival analysis on the group
with revision as the endpoint.Aims
Patients and Methods
The best time for definitive orthopaedic care is often unclear
in patients with multiple injuries. The objective of this study
was make a prospective assessment of the safety of our early appropriate
care (EAC) strategy and to evaluate the potential benefit of additional
laboratory data to determine readiness for surgery. A cohort of 335 patients with fractures of the pelvis, acetabulum,
femur, or spine were included. Patients underwent definitive fixation
within 36 hours if one of the following three parameters were met:
lactate <
4.0 mmol/L; pH ≥ 7.25; or base excess (BE) ≥ -5.5 mmol/L.
If all three parameters were met, resuscitation was designated full
protocol resuscitation (FPR). If less than all three parameters
were met, it was designated an incomplete protocol resuscitation
(IPR). Complications were assessed by an independent adjudication
committee and included infection; sepsis; PE/DVT; organ failure;
pneumonia, and acute respiratory distress syndrome (ARDS). Aims
Patients and Methods
This prospective cohort study aims to determine if the size of
the tendon gap following acute rupture of the Achilles tendon shows
an association with the functional outcome following non-operative
treatment. All patients presenting within two weeks of an acute unilateral
rupture of the Achilles tendon between July 2012 and July 2015 were
considered for the study. In total, 38 patients (nine female, 29
male, mean age 52 years; 29 to 78) completed the study. Dynamic
ultrasound examination was performed to confirm the diagnosis and
measure the gap between ruptured tendon ends. Outcome was assessed
using dynamometric testing of plantarflexion and the Achilles tendon
Total Rupture score (ATRS) six months after the completion of a
rehabilitation programme.Aims
Patients and Methods
Our aim was to describe the mid-term appearances of the repair
process of the Achilles tendon after tenotomy in children with a
clubfoot treated using the Ponseti method. A total of 15 children (ten boys, five girls) with idiopathic
clubfoot were evaluated at a mean of 6.8 years (5.4 to 8.1) after
complete percutaneous division of the Achilles tendon. The contour
and subjective thickness of the tendon were recorded, and superficial
defects and its strength were assessed clinically. The echogenicity,
texture, thickness, peritendinous irregularities and potential for
deformation of the tendon were evaluated by ultrasonography.Aims
Patients and Methods
Free vascularised fibular grafting has been used for the treatment
of large bony defects for more than 40 years. However, there is
little information about the risk factors for failure and whether
newer locking techniques of fixation improve the rates of union.
The purpose of this study was to compare the rates of union of free
fibular grafts fixed with locking and traditional techniques, and
to quantify the risk factors for nonunion and failure. A retrospective review involved 134 consecutive procedures over
a period of 20 years. Of these, 25 were excluded leaving 109 patients
in the study. There were 66 men and 43 women, with a mean age of
33 years (5 to 78). Most (62) were performed for oncological indications,
and the most common site (52) was the lower limb. Rate of union
was estimated using the Kaplan-Meier method and risk factors for
nonunion were assessed using Cox regression. All patients were followed
up for at least one year.Aims
Patients and Methods
Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (Objectives
Materials and Methods
Rates of mortality as high as 25% to 30% have been described
following fractures of the odontoid in the elderly population. The
aim of this study was to examine whether easily identifiable variables
present on admission are associated with mortality. A consecutive series of 83 elderly patients with a fracture of
the odontoid following a low-impact injury was identified retrospectively.
Data that were collected included demographics, past medical history
and the results of blood tests on admission. Radiological investigations
were used to assess the Anderson and D’Alonzo classification and
displacement of the fracture. The mean age was 82.9 years (65 to
101). Most patients (66; 79.5%) had a type 2 fracture. An associated
neurological deficit was present in 11 (13.3%). All were treated
conservatively; 80 (96.4%) with a hard collar and three (3.6%) with
halo vest immobilisation.Aims
Patients and Methods
To assess the effect of high tibial and distal femoral osteotomies
(HTO and DFO) on the pressure characteristics of the ankle joint. Varus and valgus malalignment of the knee was simulated in human
cadaver full-length legs. Testing included four measurements: baseline
malalignment, 5° and 10° re-aligning osteotomy, and control baseline
malalignment. For HTO, testing was rerun with the subtalar joint
fixed. In order to represent half body weight, a 300 N force was applied
onto the femoral head. Intra-articular sensors captured ankle pressure.Aims
Materials and Methods
Knee joint distraction (KJD) is a relatively new, knee-joint
preserving procedure with the goal of delaying total knee arthroplasty
(TKA) in young and middle-aged patients. We present a randomised
controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis
were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes
were assessed at baseline, three, six, nine, and 12 months. In the
KJD group, the joint space width (JSW) was radiologically assessed,
representing a surrogate marker of cartilage thickness.Aims
Patients and Methods
Periacetabular osteotomy is an effective way of treating symptomatic
hip dysplasia. We describe a new minimally invasive technique using
a modification of the Smith-Peterson approach. We performed a prospective, longitudinal cohort study to assess
for any compromise in acetabular correction when using this approach,
and to see if the procedure would have a higher complication rate
than that quoted in the literature for other approaches. We also
assessed for any improvement in functional outcome. From 168 consecutive patients (189 hips) who underwent acetabular
correction between March 2010 and March 2013 we excluded those who
had undergone previous pelvic surgery for DDH and those being treated
for acetabular retroversion. The remaining 151 patients (15 men,
136 women) (166 hips) had a mean age of 32 years (15 to 56) and the
mean duration of follow-up was 2.8 years (1.2 to 4.5). In all 90%
of cases were Tönnis grade 0 or 1. Functional outcomes were assessed
using the Non Arthritic Hip Score (NAHS), University of California,
Los Angeles (UCLA) and Tegner activity scores.Aims
Patients and Methods