Advertisement for orthosearch.org.uk
Results 2381 - 2400 of 4433
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1526 - 1532
1 Nov 2017
Tarride JE Hopkins RB Blackhouse G Burke N Bhandari M Johal H Guyatt GH Busse JW

Aims

This 501-patient, multi-centre, randomised controlled trial sought to establish the effect of low-intensity, pulsed, ultrasound (LIPUS) on tibial shaft fractures managed with intramedullary nailing. We conducted an economic evaluation as part of this trial.

Patients and Methods

Data for patients’ use of post-operative healthcare resources and time taken to return to work were collected and costed using publicly available sources. Health-related quality of life, assessed using the Health Utilities Index Mark-3 (HUI-3), was used to derive quality-adjusted life years (QALYs). Costs and QALYs were compared between LIPUS and control (a placebo device) from a payer and societal perspective using non-parametric bootstrapping. All costs are reported in 2015 Canadian dollars unless otherwise stated.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1508 - 1514
1 Nov 2017
Park JH Jang WY Kwak DH Park JW

Aims

Positive ulnar variance is an established risk factor for idiopathic ulnar impaction syndrome (UIS). However, not all patients with positive ulnar variance develop symptomatic UIS and other factors, including the morphology of the lunate, may be involved. The aim of this study was to clarify the relationship between lunate morphology and idiopathic UIS.

Patients and Methods

A cohort of 95 patients with idiopathic UIS (UIS group) was compared with 95 asymptomatic controls with positive ulnar variance. The shape of the lunate was measured using the capitate-triquetrum distance (CTD), ulnar coverage ratio (UCR), radiolunate distance and radiolunate angle. The association of radiographic parameters and lunate types with the development of UIS was investigated in univariable and multivariable analyses. Receiver operating characteristic curves were used to estimate a cutoff for any statistically significant variables.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1140 - 1146
1 Sep 2017
Shoji T Yamasaki T Izumi S Murakami H Mifuji K Sawa M Yasunaga Y Adachi N Ochi M

Aims

Our aim was to evaluate the radiographic characteristics of patients undergoing total hip arthroplasty (THA) for the potential of posterior bony impingement using CT simulations.

Patients and Methods

Virtual CT data from 112 patients who underwent THA were analysed. There were 40 men and 72 women. Their mean age was 59.1 years (41 to 76). Associations between radiographic characteristics and posterior bony impingement and the range of external rotation of the hip were evaluated. In addition, we investigated the effects of pelvic tilt and the neck/shaft angle and femoral offset on posterior bony impingement.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1197 - 1203
1 Sep 2017
Laumonerie P Reina N Ancelin D Delclaux S Tibbo ME Bonnevialle N Mansat P

Aims

Radial head arthroplasty (RHA) may be used in the treatment of non-reconstructable radial head fractures. The aim of this study was to evaluate the mid-term clinical and radiographic results of RHA.

Patients and Methods

Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23 women with either acute injuries (54) or with traumatic sequelae (23) of a fracture of the radial head. Four designs of RHA were used, including the Guepar (Small Bone Innovations (SBi)/Stryker; 36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten) or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up was 74.0 months (standard deviation (sd) 38.6; 24 to 141). The indication for further surgery, range of movement, mean Mayo Elbow Performance (MEP) score, quick Disabilities of the Arm, Shoulder and Hand (quickDASH) score, osteolysis and positioning of the implant were also assessed according to the design, and acute or delayed use.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 489 - 498
1 Aug 2017
Mifuji K Ishikawa M Kamei N Tanaka R Arita K Mizuno H Asahara T Adachi N Ochi M

Objectives

The objective of this study was to investigate the therapeutic effect of peripheral blood mononuclear cells (PBMNCs) treated with quality and quantity control culture (QQ-culture) to expand and fortify angiogenic cells on the acceleration of fracture healing.

Methods

Human PBMNCs were cultured for seven days with the QQ-culture method using a serum-free medium containing five specific cytokines and growth factors. The QQ-cultured PBMNCs (QQMNCs) obtained were counted and characterised by flow cytometry and real-time polymerase chain reaction (RT-PCR). Angiogenic and osteo-inductive potentials were evaluated using tube formation assays and co-culture with mesenchymal stem cells with osteo-inductive medium in vitro. In order to evaluate the therapeutic potential of QQMNCs, cells were transplanted into an immunodeficient rat femur nonunion model. The rats were randomised into three groups: control; PBMNCs; and QQMNCs. The fracture healing was evaluated radiographically and histologically.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1450 - 1457
1 Nov 2017
vanWinterswijk PJTS Whitehouse SL Timperley AJ Hubble MJW Howell JR Wilson MJ

Aims

We report the incidence of radiolucent lines (RLLs) using two flanged acetabular components at total hip arthroplasty (THA) and the effect of the Rim Cutter.

Patients and Methods

We performed a retrospective review of 300 hips in 292 patients who underwent primary cemented THA. A contemporary flanged acetabular component was used with (group 1) and without (group 2) the use of the Rim Cutter and the Rimfit acetabular component was used with the Rim Cutter (group 3). RLLs and clinical outcomes were evaluated immediately post-operatively and at five years post-operatively.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1157 - 1166
1 Sep 2017
Nerhus TK Ekeland A Solberg G Olsen BH Madsen JE Heir S

Aims

The aim of this prospective randomised study was to compare the time course of clinical improvement during the first two years following a closing or opening wedge high tibial osteotomy (HTO). It was hypothesised that there would be no differences in clinical outcome between the two techniques.

Patients and Methods

Between 2007 and 2013, 70 consecutive patients were randomly allocated to undergo either a closing or opening wedge HTO. All patients had medial compartment osteoarthritis (OA), and were aged between 30 years and 60 years. They were evaluated by independent investigators pre-operatively and at three and six months, and one and two years post-operatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Oxford Knee Score (OKS), the Lysholm score, the Tegner activity score, the University of California, Los Angeles (UCLA) activity scale and range of movement (ROM).


Bone & Joint Research
Vol. 6, Issue 10 | Pages 600 - 601
1 Oct 2017
Ghert M


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1467 - 1476
1 Nov 2017
van Hamersveld KT Marang-van de Mheen PJ Tsonaka R Valstar† ER Toksvig-Larsen S

Aims

The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs.

Patients and Methods

Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1458 - 1466
1 Nov 2017
Tsang SJ Ting J Simpson AHRW Gaston P

Aims

The aims of the study were to review and analyse the reported series of debridement, antibiotics and implant retention (DAIR) in the management of infected total hip arthroplasties (THAs) to establish the overall success and the influencing factors.

Patients and methods

Using a standardised recognised study protocol, meta-analysis of observational studies in epidemiology guidelines, a comprehensive review and analysis of the literature was performed. The primary outcome measure was the success of treatment. The search strategy and inclusion criteria which involved an assessment of quality yielded 39 articles for analysis, which included 1296 patients.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 10 - 12
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1420 - 1430
1 Nov 2017
Azboy I Barrack R Thomas AM Haddad FS Parvizi J

The number of arthroplasties being performed increases each year. Patients undergoing an arthroplasty are at risk of venous thromboembolism (VTE) and appropriate prophylaxis has been recommended. However, the optimal protocol and the best agent to minimise VTE under these circumstances are not known. Although many agents may be used, there is a difference in their efficacy and the risk of bleeding. Thus, the selection of a particular agent relies on the balance between the desire to minimise VTE and the attempt to reduce the risk of bleeding, with its undesirable, and occasionally fatal, consequences.

Acetylsalicylic acid (aspirin) is an agent for VTE prophylaxis following arthroplasty. Many studies have shown its efficacy in minimising VTE under these circumstances. It is inexpensive and well-tolerated, and its use does not require routine blood tests. It is also a ‘milder’ agent and unlikely to result in haematoma formation, which may increase both the risk of infection and the need for further surgery. Aspirin is also unlikely to result in persistent wound drainage, which has been shown to be associated with the use of agents such as low-molecular-weight heparin (LMWH) and other more aggressive agents.

The main objective of this review was to summarise the current evidence relating to the efficacy of aspirin as a VTE prophylaxis following arthroplasty, and to address some of the common questions about its use.

There is convincing evidence that, taking all factors into account, aspirin is an effective, inexpensive, and safe form of VTE following arthroplasty in patients without a major risk factor for VTE, such as previous VTE.

Cite this article: Bone Joint J 2017;99-B:1420–30.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 41 - 43
1 Aug 2017
de Bono J


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1286 - 1289
1 Oct 2017
Rajpura A Board TN Siney PD Wynn Jones H Williams S Dabbs L Wroblewski BM

Aims

Our aim in this study was to describe a continuing review of 11 total hip arthroplasties using 22.225 mm Alumina ceramic femoral heads on a Charnley flanged femoral component, articulating against a silane crosslinked polyethylene.

Patients and Methods

Nine patients (11 THAs) were reviewed at a mean of 27.5 years (26 to 28) post-operatively. Outcome was assessed using the d’Aubigne and Postel, and Charnley scores and penetration was recorded on radiographs. In addition, the oxidation of a 29-year-old shelf-aged acetabular component was analysed.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 21 - 24
1 Jun 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 18 - 20
1 Oct 2017


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1067 - 1072
1 Aug 2017
Booker SJ Boyd M Gallacher S Evans JP Auckland C Kitson J Thomas W Smith CD

Aims

Our aim was to investigate the prevalence of Propionibacterium (P.) acnes in the subcutaneous fat and capsule of patients undergoing shoulder surgery for frozen shoulder or instability.

Patients and Methods

A total of 46 patients undergoing either an arthroscopic capsular release or stabilisation had biopsies taken from the subcutaneous fat and capsule of the shoulder at the time of surgery. These samples were sent for culture in enrichment, and also for Nucleic Acid Amplification testing. The prevalence of P. acnes and other microbes was recorded. Fisher's exact test of binary variables was used to calculate the association with significance set at p < 0.05. Assessment of influence of independent variables including a pre-operative glenohumeral injection, fat colonisation and gender, was undertaken using binary linear regression.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1073 - 1079
1 Aug 2017
Pauzenberger L Domej MA Heuberer PR Hexel M Grieb A Laky B Blasl J Anderl W

Aims

The purpose of the present study was to evaluate the impact of intravenous tranexamic acid on the reduction of blood loss, transfusion rate, and early post-operative clinical outcome in total shoulder arthroplasty.

Patients and Methods

A randomised, placebo-controlled trial which included 54 patients undergoing unilateral primary stemless anatomical or stemmed reverse total shoulder arthroplasty was undertaken. Patients received either 100 ml saline (placebo, n = 27), or 100 ml saline together with 1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to skin incision and during wound closure. Peri-operative blood loss via an intra-articular drain was recorded and total blood loss was calculated. The post-operative transfusion rate was documented. Assessment of early clinical parameters included the visual analogue scale for pain (VAS), documentation of haematoma formation and adverse events.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1348 - 1353
1 Oct 2017
Tang CQY Lai SWH Tay SC

Aims

Few studies have examined the long-term outcome of carpal tunnel release (CTR). The aim of this study was to evaluate the patient-reported long-term outcome of CTR for electrophysiologically severe carpal tunnel syndrome (CTS).

Patients and Methods

We reviewed the long-term outcome of 40 patients with bilateral severe CTS who underwent 80 CTRs (46 open, 34 endoscopic) between 2002 and 2012. The outcomes studied were patient-reported outcomes of numbness resolution, the Boston Carpal Tunnel Questionnaire (BCTQ) score, and patient satisfaction.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1343 - 1347
1 Oct 2017
Yalizis MA Ek ETH Anderson H Couzens G Hoy GA

Aims

To determine whether an early return to sport in professional Australian Rules Football players after fixation of a non-thumb metacarpal fracture was safe and effective.

Patients and Methods

A total of 16 patients with a mean age of 25 years (19 to 30) identified as having a non-thumb metacarpal fracture underwent open reduction and internal plate and screw fixation. We compared the players’ professional performance statistics before and after the injury to determine whether there was any deterioration in their post-operative performance.