Advertisement for orthosearch.org.uk
Results 221 - 240 of 488
Results per page:
Bone & Joint Research
Vol. 8, Issue 1 | Pages 1 - 2
1 Jan 2019
Clauss M Breusch SJ


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 532 - 566
1 Aug 1966
Burwell RG

1. The present study is an attempt to analyse and apportion significance to the role of inductive mechanisms in bone transplantation. 2. The experimental model used in the present work is that of the composite homograftautograft of cancellous bone previously described (Burwell 1964a). 3. Iliac bone was removed from hooded rats and washed free from its marrow. The bone was then treated by various physical and chemical methods (some of which have been used by other workers to prepare bank bone), namely freezing (-20 degrees Centigrade, -79 degrees Centigrade, -196 degrees Centigrade); freeze-drying (without sterilisation, sterilisation with high energy radiation, sterilisation with ß-propiolactone); decalcification (with E.D.T.A.); irradiation (in the frozen state at a dose of 4 million rads); boiling in water; immersion in merthiolate solution; extraction of organic components with ethylenediamine: and calcining at 660 degrees Centigrade. The treated bone was then impregnated with fresh autologous marrow procured from the femoral shaft of the Wistar rat into which the treated composite graft was to be implanted. The grafts were inserted intramuscularly and removed for study after two, six and twelve weeks. 4. After fixation, serial sectioning and staining, each graft was examined microscopically, and the proportion of new bone/grafted bone scored using an arbitrary scale (0-4). The mean score (and the standard error of the mean score) was then plotted for each treated composite graft and also for several types of fresh cancellous bone grafts. 5. It was found (Fig. 2) that the various treated composite grafts formed a spectrum of bone-forming capacities–the maximum scores being attained by the frozen and freeze-dried composite grafts, the lowest scores by the "deproteinised" composite grafts. 6. The reasons for these differences are discussed. It is concluded that cancellous bone, after transplantation, has the property to induce and promote osteogenesis in marrow; moreover, that this property is contained in the organic components of bone. 7. From the standpoint of inductive mechanisms, cancellous bone treated by freezing or freeze-drying seems to be the most suitable devitalised bone for grafting purposes; bone which has been boiled or merthiolated less suitable; and "deproteinised" bone the least suitable. 8. Freeze-dried bone sterilised physically (by high energy radiation) or chemically (by ß-propiolactone) did not form significantly less new bone than did freeze-dried bone which had not been sterilised. 9. Remodelling mechanisms in bone transplantation are briefly discussed and attention drawn to the deficiencies of present knowledge. The quantitative studies of other workers have indicated that freeze-dried bone may be more rapidly remodelled than is frozen bone. 10. The importance of fresh red marrow in promoting osteogenesis in bone transplantation and in the healing of certain fractures, is emphasised. It seems likely that the interrelationship of bone and marrow revealed by experiment has wider significance not only in health and in response to injury but also in causation of certain idiopathic bone disorders


Bone & Joint Research
Vol. 8, Issue 6 | Pages 226 - 227
1 Jun 2019
Danese I Pankaj P Scott CEH


Bone & Joint Research
Vol. 8, Issue 2 | Pages 81 - 89
1 Feb 2019
Funk GA Menuey EM Cole KA Schuman TP Kilway KV McIff TE

Objectives

The objective of this study was to characterize the effect of rifampin incorporation into poly(methyl methacrylate) (PMMA) bone cement. While incompatibilities between the two materials have been previously noted, we sought to identify and quantify the cause of rifampin’s effects, including alterations in curing properties, mechanical strength, and residual monomer content.

Methods

Four cement groups were prepared using commercial PMMA bone cement: a control; one with 1 g of rifampin; and one each with equimolar amounts of ascorbic acid or hydroquinone relative to the amount of rifampin added. The handling properties, setting time, exothermic output, and monomer loss were measured throughout curing. The mechanical strength of each group was tested over 14 days. A radical scavenging assay was used to assess the scavenging abilities of rifampin and its individual moieties.


Bone & Joint Research
Vol. 8, Issue 6 | Pages 253 - 254
1 Jun 2019
de Steiger R


Bone & Joint 360
Vol. 8, Issue 3 | Pages 31 - 33
1 Jun 2019


Bone & Joint 360
Vol. 7, Issue 4 | Pages 28 - 31
1 Aug 2018


Bone & Joint Research
Vol. 8, Issue 6 | Pages 246 - 252
1 Jun 2019
Liddle A Webb M Clement N Green S Liddle J German M Holland J

Objectives

Previous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. Commonly, the original cement mantle is reshaped, aiding accurate placement of the new stem. Ultrasonic devices selectively remove cement, preserve host bone, and have lower cortical perforation rates than other techniques. As far as the authors are aware, the impact of ultrasonic devices on final cement-in-cement bonds has not been investigated. This study assessed the impact of cement removal using the Orthosonics System for Cemented Arthroplasty Revision (OSCAR; Orthosonics) on final cement-in-cement bonds.

Methods

A total of 24 specimens were manufactured by pouring cement (Simplex P Bone Cement; Stryker) into stainless steel moulds, with a central rod polished to Stryker Exeter V40 specifications. After cement curing, the rods were removed and eight specimens were allocated to each of three internal surface preparation groups: 1) burr; 2) OSCAR; and 3) no treatment. Internal holes were recemented, and each specimen was cut into 5 mm discs. Shear testing of discs was completed by a technician blinded to the original grouping, recording ultimate shear strengths. Scanning electron microscopy (SEM) was completed, inspecting surfaces of shear-tested specimens.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 768 - 778
1 Jul 2019
Galea VP Rojanasopondist P Ingelsrud LH Rubash HE Bragdon C Huddleston III JI Malchau H Troelsen A

Aims

The primary aim of this study was to quantify the improvement in patient-reported outcome measures (PROMs) following total hip arthroplasty (THA), as well as the extent of any deterioration through the seven-year follow-up. The secondary aim was to identify predictors of PROM improvement and deterioration.

Patients and Methods

A total of 976 patients were enrolled into a prospective, international, multicentre study. Patients completed a battery of PROMs prior to THA, at three months post-THA, and at one, three, five, and seven-years post-THA. The Harris Hip Score (HHS), the 36-Item Short-Form Health Survey (SF-36) Physical Component Summary (PCS), the SF-36 Mental Component Summary (MCS), and the EuroQol five-dimension three-level (EQ-5D) index were the primary outcomes. Longitudinal changes in each PROM were investigated by piece-wise linear mixed effects models. Clinically significant deterioration was defined for each patient as a decrease of one half of a standard deviation (group baseline).


Bone & Joint 360
Vol. 7, Issue 5 | Pages 36 - 38
1 Oct 2018


Bone & Joint 360
Vol. 7, Issue 4 | Pages 31 - 33
1 Aug 2018


Bone & Joint 360
Vol. 7, Issue 4 | Pages 25 - 28
1 Aug 2018


Bone & Joint 360
Vol. 8, Issue 1 | Pages 13 - 16
1 Feb 2019


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 56 - 63
1 Jan 2018
Smith NA Parsons N Wright D Hutchinson C Metcalfe A Thompson P Costa ML Spalding T

Aims

Meniscal allograft transplantation is undertaken to improve pain and function in patients with a symptomatic meniscal deficient knee compartment. While case series have shown improvements in patient reported outcome measures (PROMs), its efficacy has not been rigorously evaluated. This study aimed to compare PROMs in patients having meniscal transplantation with those having personalized physiotherapy at 12 months.

Patients and Methods

A single-centre assessor-blinded, comprehensive cohort study, incorporating a pilot randomized controlled trial (RCT) was performed on patients with a symptomatic compartment of the knee in which a (sub)total meniscectomy had previously been performed. They were randomized to be treated either with a meniscal allograft transplantation or personalized physiotherapy, and stratified for malalignment of the limb. They entered the preference groups if they were not willing to be randomized. The Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) score and Lysholm score and complications were collected at baseline and at four, eight and 12 months following the interventions.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 50 - 59
1 Jan 2017
Carli AV Negus JJ Haddad FS

Aims

Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used.

Patients and Methods

A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 455 - 460
1 Apr 2018
Mumith A Thomas M Shah Z Coathup M Blunn G

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research.

This review describes the current position in the use of additive manufacturing in orthopaedic surgery.

Cite this article: Bone Joint J 2018;100-B:455-60.


Bone & Joint 360
Vol. 6, Issue 5 | Pages 30 - 33
1 Oct 2017


Bone & Joint 360
Vol. 7, Issue 5 | Pages 30 - 33
1 Oct 2018


Bone & Joint 360
Vol. 7, Issue 1 | Pages 20 - 22
1 Feb 2018