To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death.Aims
Methods
We undertook a retrospective comparative study
of all patients with an unstable slipped capital femoral epiphysis presenting
to a single centre between 1998 and 2011. There were 45 patients
(46 hips; mean age 12.6 years; 9 to 14); 16 hips underwent intracapsular
cuneiform osteotomy and 30 underwent pinning in situ,
with varying degrees of serendipitous reduction. No patient in the
osteotomy group was lost to follow-up, which was undertaken at a
mean of 28 months (11 to 48); four patients in the pinning in
situ group were lost to follow-up, which occurred at a
mean of 30 months (10 to 50).
The April 2012 Hip &
Pelvis Roundup. 360. looks at osteoporotic hip fractures, retrotrochanteric pain, fibrin adhesive and reattachment of articular cartilage, autologous bone marrow mononuclear cells and
Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph.Aims
Methods
We present our experience of the modified Dunn
procedure in combination with a Ganz surgical dislocation of the hip
to treat patients with severe slipped capital femoral epiphysis
(SCFE). The aim was to prospectively investigate whether this technique
is safe and reproducible. We assessed the degree of reduction, functional
outcome, rate of complications, radiological changes and range of
movement in the hip. There were 28 patients with a mean follow-up
of 38.6 months (24 to 84). The lateral slip angle was corrected
by a mean of 50.9° (95% confidence interval 44.3 to 57.5). The mean
modified Harris hip score at the final follow-up was 89.1 (. sd. 9.0)
and the mean Non-Arthritic Hip score was 91.3 (. sd. 9.0).
Two patients had proven pre-existing
Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of
Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis.Aims
Methods
We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score.Aims
Methods
Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.Aims
Methods
We describe our experience in the reduction of
dislocation of the hip secondary to developmental dysplasia using ultrasound-guided
gradual reduction using flexion and abduction continuous traction
(FACT-R). During a period of 13 years we treated 208 Suzuki type
B or C complete dislocations of the hip in 202 children with a mean
age of four months (0 to 11). The mean follow-up was 9.1 years (five
to 16). The rate of reduction was 99.0%. There were no recurrent
dislocations, and the rate of
The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.Aims
Methods
Slipped upper femoral epiphysis (SUFE) is the
most common hip disorder to affect adolescents. Controversy exists over
the optimal treatment of severe slips, with a continuing debate
between in situ fixation versus corrective surgery.
We present our experience in a series of 57 patients presenting
with severe unilateral SUFE (defined >
50°) managed with a subcapital
cuneiform osteotomy. Between 2001 and 2011, 57 patients (35 male, 22 female) with
a mean age of 13.1 years (9.6 to 20.3, SD 2.3) were referred to
our tertiary referral institution with a severe slip. The affected
limb was rested in slings and springs before corrective surgery
which was performed via an anterior Smith-Petersen approach. Radiographic
analysis confirmed an improvement in mean head–shaft slip angle
from 53.8. o. (standard deviation (. sd) 3.2). pre-operatively
to 9.1. o. (. sd. 3.1) post-operatively, with minimal
associated femoral neck shortening. In total 50 (88%) patients were complication
free at a mean follow-up of seven years (2.8 to 13.9 years, . sd. 3).
Their mean Oxford hip score was 44 (37 to 48) and median visual
analogue pain score was 0 out of 10 (interquartile range 0 to 4).
A total of six patients (10.5%) developed
Slipped capital femoral epiphysis (SCFE) may
lead to symptomatic femoroacetabular impingement (FAI). We report our
experience of arthroscopic treatment, including osteochondroplasty,
for the sequelae of SCFE. . Data were prospectively collected on patients undergoing arthroscopy
of the hip for the sequelae of SCFE between March 2007 and February
2013, including demographic data, radiological assessment of the
deformity and other factors that may influence outcome, such as
the presence of established
1. The results of treatment of 134 patients with congenital dislocation of 167 hips are reviewed. 2. Late diagnosis is still a major problem. 3. Subluxations rarely give rise to poor results, but in dislocations first treated over the age of five years there is a one-in-three risk of failure. 4. Manipulative reduction is successful less often than reduction on a frame and carries a higher risk of
In this study we evaluated the results of midtarsal
release and open reduction for the treatment of children with convex
congenital foot (CCF) (vertical talus) and compared them with the
published results of peritalar release. Between 1977 and 2009, a
total of 22 children (31 feet) underwent this procedure. In 15 children
(48%) the CCF was isolated and in the remainder it was not (seven
with arthrogryposis, two with spinal dysraphism, one with a polymalformative
syndrome and six with an undefined neurological disorder). Pre-operatively, the mean tibiotalar angle was 150.2° (106° to
175°) and the mean calcaneal pitch angle was -19.3° (-72° to 4°).
The procedure included talonavicular and calcaneocuboid joint capsulotomies,
lengthening of tendons of tibialis anterior and the extensors of
the toes, allowing reduction of the midtarsal joints. Lengthening
of the Achilles tendon was necessary in 23 feet (74%). The mean follow-up was 11 years (2 to 21). The results, as assessed
by the Adelaar score, were good in 24 feet (77.4%), fair in six
(19.3%) and poor in one foot (3.3%), with no difference between
those with isolated CCF and those without. The mean American Orthopaedic
Foot and Ankle Society midfoot score was 89.9 (54 to 100) and 77.8
(36 to 93) for those with isolated CCF and those without, respectively.
At the final follow-up, the mean tibiotalar (120°; 90 to 152) and
calcaneal pitch angles (4°; -13 to 22) had improved significantly
(p <
0.0001). Dislocation of the talonavicular and calcaneocuboid
joints was completely reduced in 22 (70.9%) and 29 (93.6%) of feet,
respectively. Three children (five feet) underwent further surgery
at a mean of 8.5 years post-operatively, three with pes planovalgus
and two in whom the deformity had been undercorrected. No child
developed
The treatment of developmental dysplasia of the hip diagnosed after the first year of life remains controversial. A series of 36 children (47 hips), aged between one and 4.9 years underwent gradual closed reduction using the Petit-Morel method. A pelvic osteotomy was required in 43 hips (91.5%). The patients whose hips did not require pelvic osteotomy were among the youngest. The mean age at final follow-up was 16.1 years (11.3 to 32). The mean follow-up was 14.3 years (10 to 30). At the latest follow-up, 44 hips (93.6%) were graded as excellent or good according to the Severin classification. Closed reduction failed in only two hips (4.3%) which then required open reduction. Mild
Talonavicular and subtalar joint fusion through
a medial incision (modified triple arthrodesis) has become an increasingly
popular technique for treating symptomatic flatfoot deformity caused
by posterior tibial tendon dysfunction. The purpose of this study was to look at its clinical and radiological
mid- to long-term outcomes, including the rates of recurrent flatfoot
deformity, nonunion and