The aim of this study was to identify the most effective regimen
of multiple doses of oral tranexamic acid (TXA) in achieving maximum
reduction of blood loss in total knee arthroplasty (TKA). In this randomized controlled trial, 200 patients were randomized
to receive a single dose of 2.0 g of TXA orally two hours preoperatively
(group A), a single dose of TXA followed by 1.0 g orally three hours
postoperatively (group B), a single dose of TXA followed by 1.0 g
three and nine hours postoperatively (group C), or a single dose
of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively
(group D). All patients followed a routine enhanced-recovery protocol.
The primary outcome measure was the total blood loss. Secondary
outcome measures were hidden blood loss (HBL), reduction in the
level of haemoglobin, the rate of transfusion and adverse events.Aims
Patients and Methods
The objective of this study was to compare early postoperative
functional outcomes and time to hospital discharge between conventional
jig-based total knee arthroplasty (TKA) and robotic-arm assisted
TKA. This prospective cohort study included 40 consecutive patients
undergoing conventional jig-based TKA followed by 40 consecutive
patients receiving robotic-arm assisted TKA. All surgical procedures
were performed by a single surgeon using the medial parapatellar
approach with identical implant designs and standardized postoperative inpatient
rehabilitation. Inpatient functional outcomes and time to hospital
discharge were collected in all study patients.Aims
Patients and Methods
The management of a significant bony defect following excision
of a diaphyseal atrophic femoral nonunion remains a challenge. We
present the outcomes using a combined technique of acute femoral
shortening, stabilized with a long retrograde intramedullary nail,
accompanied by bifocal osteotomy compression and distraction osteogenesis with
a temporary monolateral fixator. Eight men and two women underwent the ‘rail and nail’ technique
between 2008 and 2016. Proximal locking of the nail and removal
of the external fixator was undertaken once the length of the femur
had been restored and prior to full consolidation of the regenerate.Aims
Patients and Methods
Guided growth using eight-plates is commonly used for correction
of angular limb deformities in growing children. The principle is
of tethering at the physeal periphery while enabling growth in the
rest of the physis. The method is also applied for epiphysiodesis
to correct limb-length discrepancy (LLD). Concerns have been raised
regarding the potential of this method to create an epiphyseal deformity.
However, this has not been investigated. The purpose of this study
was to detect and quantify the occurrence of deformities in the
proximal tibial epiphysis following treatment with eight-plates. A retrospective study was performed including 42 children at
a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion
in the proximal tibia for correction of coronal plane deformities
or LLD between 2007 and 2015. A total of 64 plates were inserted;
48 plates (34 patients) were inserted to correct angular deformities
and 16 plates (8 patients) for LLD. Medical records, Picture Archive
and Communication System images, and conventional radiographs were
reviewed. Measurements included interscrew angle, lateral and medial
plateau slope angles measured between the plateau surface and the
line between the ends of the physis, and tibial plateau roof angle defined
as 180° minus the sum of both plateau angles. Measurements were
compared between radiographs performed adjacent to surgery and those
at latest follow-up, and between operated and non-operated plateaus. Statistical
analysis was performed using BMDP Statistical Software.Aims
Patients and Methods
The aim of this study was to evaluate improvements in the quality
and safety of paediatric spinal surgery following the implementation
of a specialist Paediatric Spinal Surgical Team (PSST) in the operating
theatre. A retrospective consecutive case study of paediatric spinal operations
before (between January 2008 and December 2009), and after (between
January 2012 and December 2013) the implementation of PSST, was
performed. A comparative analysis of outcome variables including
surgical site infection (SSI), operating time (ORT), blood loss (BL),
length of stay (LOS), unplanned staged procedures (USP) and transfusion
rates (allogenic and cell-saver) was performed between the two groups.
The rate of complications during the first two postoperative years
was also compared between the groups.Aims
Patients and Methods
The aims of this study were to compare the efficacy and safety
of intra-articular and intravenous (IV) tranexamic acid (TXA) in
controlling perioperative blood loss in total knee arthroplasty
(TKA) using a randomized, double-blinded equivalence trial. A total of 182 patients aged between 45 and 75 years undergoing
unilateral TKA at a tertiary centre were randomized to receive TXA,
either 1.5 g intra-articularly after closure of the wound (n = 91)
or two doses of 10 mg/kg IV (n = 91). The primary outcome measure
was the reduction in the level of haemoglobin (Hb) in the blood
on the fifth postoperative day. Secondary outcome measures were
the total, visible, and hidden blood losses (TBL, VBL, HBL). We
assumed equivalence of the primary outcome in both routes with a
margin of ± 0.35gm/dl. Block randomization using computer-generated
random numbers was used. The patients and the assessor of outcome were
blinded.Aims
Patients and Methods
The success of anterior cruciate ligament reconstruction (ACLR)
depends on osseointegration at the graft-tunnel interface and intra-articular
ligamentization. Our aim was to conduct a systematic review of clinical
and preclinical studies that evaluated biological augmentation of
graft healing in ACLR. In all, 1879 studies were identified across three databases.
Following assessment against strict criteria, 112 studies were included
(20 clinical studies; 92 animal studies). Aims
Materials and Methods
We present the ten-year data of a cohort of patients, aged between
18 and 65 years (mean age 52.7 years; 19 to 64), who underwent total
hip arthroplasty. Patients were randomised to be treated with a
cobalt-chrome (CoCr) femoral head with an ultra-high molecular weight
polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE) or
ceramic-on-ceramic (CoC) bearing surface. A total of 102 hips (91 patients) were randomised into the three
groups. At ten years, 97 hips were available for radiological and
functional follow-up. Two hips (two patients) had been revised (one
with deep infection and one for periprosthetic fracture) and three
were lost to follow-up. Radiological analysis was performed using
a validated digital assessment programme to give linear, directional
and volumetric wear of the two polyethylene groups.Aims
Patients and Methods
The optimal method of tibial component fixation remains uncertain
in total knee arthroplasty (TKA). Hydroxyapatite coatings have been
applied to improve bone ingrowth in uncemented designs, but may
only coat the directly accessible surface. As peri-apatite (PA)
is solution deposited, this may increase the coverage of the implant
surface and thereby fixation. We assessed the tibial component fixation
of uncemented PA-coated TKAs Patients were randomised to PA-coated or cemented TKAs. In 60
patients (30 in each group), radiostereometric analysis of tibial
component migration was evaluated as the primary outcome at baseline,
three months post-operatively and at one, two and five years. A
linear mixed-effects model was used to analyse the repeated measurements.Aims
Patients and Methods
To determine whether an early return to sport in professional
Australian Rules Football players after fixation of a non-thumb
metacarpal fracture was safe and effective. A total of 16 patients with a mean age of 25 years (19 to 30)
identified as having a non-thumb metacarpal fracture underwent open
reduction and internal plate and screw fixation. We compared the
players’ professional performance statistics before and after the
injury to determine whether there was any deterioration in their
post-operative performance.Aims
Patients and Methods
We compared the clinical and radiological outcomes of using a
polyetheretherketone cage with (TiPEEK) and without a titanium coating
(PEEK) for instrumented transforaminal lumbar interbody fusion (TLIF). We conducted a randomised clinical pilot trial of 40 patients
who were scheduled to undergo a TLIF procedure at one or two levels
between L2 and L5. The Oswestry disability index (ODI), EuroQoL-5D,
and back and leg pain were determined pre-operatively, and at three,
six, and 12 months post-operatively. Fusion rates were assessed
by thin slice CT at three months and by functional radiography at
12 months.Aims
Materials and Methods
The purpose of this study was to assess early physical function
after total hip or knee arthroplasty (THA/TKA), and the correlation
between patient-reported outcome measures, physical performance
and actual physical activity (measured by actigraphy). A total of 80 patients aged 55 to 80 years undergoing THA or
TKA for osteoarthritis were included in this prospective cohort
study. The main outcome measure was change in patient reported hip
or knee injury and osteoarthritis outcome score (HOOS/KOOS) from
pre-operatively until post-operative day 13 (THA) or 20 (TKA). Secondary measures
were correlations to objectively assessed change in physical performance
(paced-walk, chair-stand, stair-climb tests) at day 14 (THA) or
21 (TKA) and actual physical activity (actigraphy) measured at day
12 and 13 (THA) or 19 and 20 (TKA). Aims
Patients and Methods
The aim of the present study was to compare the 30- and 90-day
re-admission rates and complication rates of outpatient and inpatient
total shoulder arthroplasty (TSA). The United States Medicare Standard Analytical Files database
was questioned to identify patients who had undergone outpatient
or inpatient TSA between 2005 and 2012. Patient characteristics
were compared between the two groups using chi-squared analysis. Multivariate
logistic regression analysis was used to control for differences
in baseline patient characteristics and to compare the two groups
in terms of post-operative complications within 90 days and re-admission
within 30 days and 90 days.Aims
Patients and Methods
To determine whether the findings from a landmark Canadian trial
assessing the optimal management of acute rupture of the Achilles
tendon influenced the practice patterns of orthopaedic surgeons
in Ontario, Canada. Health administrative databases were used to identify Ontario
residents ≥ 18 years of age with an Achilles tendon rupture from
April 2002 to March 2014. The rate of surgical repair (per 100 cases)
was calculated for each calendar quarter. A time-series analysis
was used to determine whether changes in the rate were chronologically
related to the dissemination of results from a landmark trial published
in February 2009. Non-linear spline regression was then used independently
to identify critical time-points of change in the surgical repair
rate to confirm the findings.Aims
Materials and Methods
We have increased the dose of tranexamic acid (TXA) in our enhanced total joint recovery protocol at our institution from 15 mg/kg to 30 mg/kg (maximum 2.5 g) as a single, intravenous (IV) dose. We report the clinical effect of this dosage change. We retrospectively compared two cohorts of consecutive patients undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA) surgery in our unit between 2008 and 2013. One group received IV TXA 15 mg/kg, maximum 1.2 g, and the other 30 mg/kg, maximum 2.5 g as a single pre-operative dose. The primary outcome for this study was the requirement for blood transfusion within 30 days of surgery. Secondary measures included length of hospital stay, critical care requirements, re-admission rate, medical complications and mortality rates.Objectives
Methods