Advertisement for orthosearch.org.uk
Results 201 - 220 of 613
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims

The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA).

Methods

Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1436 - 1440
1 Nov 2016
Abdel MP Roth PV Harmsen WS Berry DJ

Aims. The purpose of this study was to determine the lifetime risk of revision surgery for patients undergoing Charnley cemented total hip arthroplasty (THA), with 40-year follow up, using death as a competing risk. . Materials and Methods. We retrospectively reviewed 2000 cemented Charnley THAs, with 51 living hips available at 40 years. . Results. The cumulative risk of revision or removal for any reason was 13% (95% confidence interval (CI) 12 to 15). Patients aged under 50 years at the time of surgery had a 35% (95% CI 28 to 42) risk of revision or removal for any reason (Hazard Ratio (HR) 3.6; 95% CI 2.5 to 5.2; p <  0.001), patients 50 to 59 years old had a 20% risk (95% CI 16 to 24) (HR 2.1; 95% CI 1.5 to 2.8; p < 0.0001), patients aged 60 to 69 years had a 9% risk (95% CI 7 to 11) (reference point), and patients ≥ 70 years old had a 5% risk (95% CI 4 to 7) (HR 0.96; 95% CI 0.6 to 1.5; p = 0.86) during their lifetime. Men had a higher risk of revision or removal for any reason (HR 2.1; 95% CI 1.7 to 2.7; p < 0.001). . Conclusion. With almost all the patients in this series followed up till either death or revision, we have been able to develop a ‘rule of thumb’ for lifetime likelihood of revision or implant removal for the Charnley THA: one in three for patients < 50 years, one in five for patients 50 to 59 years, one in ten for patients 60 to 69 years, and one in 20 for patients ≥ 70 years. The results provide a benchmark for comparison of outcomes, for the newer designs of THA. . Cite this article: Bone Joint J 2016;98-B:1436–40


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 589 - 597
2 May 2022
Atrey A Pincus D Khoshbin A Haddad FS Ward S Aktar S Ladha K Ravi B

Aims

Total hip arthroplasty (THA) is one of the most successful surgical procedures. The objectives of this study were to define whether there is a correlation between socioeconomic status (SES) and surgical complications after elective primary unilateral THA, and investigate whether access to elective THA differs within SES groups.

Methods

We conducted a retrospective, population-based cohort study involving 202 hospitals in Ontario, Canada, over a 17-year period. Patients were divided into income quintiles based on postal codes as a proxy for personal economic status. Multivariable logistic regression models were then used to primarily assess the relationship between SES and surgical complications within one year of index THA.


Bone & Joint Research
Vol. 11, Issue 12 | Pages 873 - 880
1 Dec 2022
Watanabe N Miyatake K Takada R Ogawa T Amano Y Jinno T Koga H Yoshii T Okawa A

Aims

Osteoporosis is common in total hip arthroplasty (THA) patients. It plays a substantial factor in the surgery’s outcome, and previous studies have revealed that pharmacological treatment for osteoporosis influences implant survival rate. The purpose of this study was to examine the prevalence of and treatment rates for osteoporosis prior to THA, and to explore differences in osteoporosis-related biomarkers between patients treated and untreated for osteoporosis.

Methods

This single-centre retrospective study included 398 hip joints of patients who underwent THA. Using medical records, we examined preoperative bone mineral density measures of the hip and lumbar spine using dual energy X-ray absorptiometry (DXA) scans and the medications used to treat osteoporosis at the time of admission. We also assessed the following osteoporosis-related biomarkers: tartrate-resistant acid phosphatase 5b (TRACP-5b); total procollagen type 1 amino-terminal propeptide (total P1NP); intact parathyroid hormone; and homocysteine.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 614 - 622
1 May 2017
Grammatopoulos G Bolduc M Atkins BL Kendrick BJL McLardy-Smith P Murray DW Gundle R Taylor AH

Aims. Advocates of debridement, antibiotics and implant retention (DAIR) in hip periprosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared with revision. This case-control study aims were to compare outcome of DAIRs for infected primary total hip arthroplasty (THA) with outcomes following primary THA and two-stage revision of infected primary THAs. Patients and Methods. We retrospectively reviewed all DAIRs, performed for confirmed infected primary hip arthropasty (n = 82) at out institution, between 1997 and 2013. Data recorded included full patient information and type of surgery. Outcome measures included complications, mortality, implant survivorship and functional outcome. Outcome was compared with two control groups matched for gender and age; a cohort of primary THAs (n = 120) and a cohort of two-stage revisions for infection (n = 66). Results. Mean age at DAIR was 69 years (33 to 87) and mean follow-up was eight years (2 to 17; standard deviation (. sd). 5). A total of 52 (63%) of DAIRs were for early PJI (less than six weeks). Greater success in the eradication of infection with DAIR was identified with early PJI, comprising an interval less than a week between onset of symptoms and exchange of modular components with the DAIR procedure. Eradication of infection, complications and re-operation rates were similar in the DAIR and two-stage revision groups. For hips with successful eradication of infection with DAIR, the five-year survival (98%; 95% confidence interval (CI) 94 to 100) was similar to the primary THA group (98%; 95% CI 95 to 100) (n = 43; p = 0.3). The DAIR group had inferior mean Oxford Hip Scores (OHS) (38; 12 to 48) compared with the primary THA group (42; 15 to 48) (p = 0.02) but a significantly better mean OHS compared with the two-stage revision group (31; 0 to 48) (p = 0.008). Patients who required only one DAIR for eradication of infection had a similar mean OHS (41; 20 to 48) to the primary THA group (p = 0.2). Conclusion. The DAIR procedure is associated with a similar complication rate and ability to eradicate infection as two-stage revision. This study emphasises the need for exchange of modular components for improved chances of eradication of infection. This is the first study showing that DAIR is better than a two-stage revision regarding functional outcome. Cite this article: Bone Joint J 2017;99-B:614–22


Bone & Joint 360
Vol. 11, Issue 3 | Pages 14 - 17
1 Jun 2022


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 987 - 996
1 Aug 2022

Aims

The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population.

Methods

This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1039 - 1046
1 Sep 2022
Özdemir E Kuijpers MFL Visser J Schreurs BW Rijnen WHC

Aims

The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique.

Methods

We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1292 - 1303
1 Dec 2022
Polisetty TS Jain S Pang M Karnuta JM Vigdorchik JM Nawabi DH Wyles CC Ramkumar PN

Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered.

Cite this article: Bone Joint J 2022;104-B(12):1292–1303.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 859 - 866
4 Nov 2022
Diesel CV Guimarães MR Menegotto SM Pereira AH Pereira AA Bertolucci LH Freitas EC Galia CR

Aims

Our objective was describing an algorithm to identify and prevent vascular injury in patients with intrapelvic components.

Methods

Patients were defined as at risk to vascular injuries when components or cement migrated 5 mm or more beyond the ilioischial line in any of the pelvic incidences (anteroposterior and Judet view). In those patients, a serial investigation was initiated by a CT angiography, followed by a vascular surgeon evaluation. The investigation proceeded if necessary. The main goal was to assure a safe tissue plane between the hardware and the vessels.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1347 - 1354
1 Oct 2016
Palan J Smith MC Gregg P Mellon S Kulkarni A Tucker K Blom AW Murray DW Pandit H

Aims. Periprosthetic fracture (PF) after primary total hip arthroplasty (THA) is an uncommon but potentially devastating complication. This study aims to investigate the influence of cemented stem designs on the risk of needing a revision for a PF. Patients and Methods. We analysed data on 257 202 primary THAs with cemented stems and 390 linked first revisions for PF recorded in the National Joint Registry (NJR) of England, Wales and Northern Ireland to determine if a cemented femoral stem brand was associated with the risk of having revision for a PF after primary THA. All cemented femoral stem brands with more than 10 000 primary operations recorded in the NJR were identified. The four most commonly used cemented femoral stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem (n = 15 113) and Charnley (n = 20 182). We compared the revision risk ratios due to PF amongst the stems using a Poisson regression model adjusting for patient factors. Compared with the Exeter V40, the age, gender and ASA grade adjusted revision rate ratio was 3.89 for the cemented CPT stem (95% confidence interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to 1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70). Conclusions. The limitations of the study include incomplete data capture, analysis of only PF requiring revision and that observation does not imply causality. Nevertheless, this study demonstrates that the choice of a cemented stem may influence the risk of revision for PF. Cite this article: Bone Joint J 2016;98-B:1347–54


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 320 - 325
1 Mar 2016
Gundtoft PH Pedersen AB Schønheyder HC Overgaard S

Aims. The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). Patients and Methods. We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005 and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We estimated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for PJI in the DHR alone and in the DHR when combined with microbiology databases. Results. In total, 1382 of the 37 826 primary THAs in the DHR were registered as having been revised for any cause once 26 patients with errors in registration had been excluded: 232 of these were for PJI. For this group, the sensitivity was 67%, specificity 95%, PPV 77%, and NPV 92%. Combining the data from the DHR with those from microbiology databases increased the sensitivity to 90% and also improved specificity (100%), PPV (98%) and NPV (98%). Conclusion. Only two thirds of revisions for PJI were captured in the DHR and only 77% of the PJI reported to the DHR could be confirmed to be infected. . Take home message: combining the data from the DHR with those from microbiology databases substantially improved the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320–5


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims

This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA).

Methods

Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 468 - 474
1 Apr 2016
Abdel MP Houdek MT Watts CD Lewallen DG Berry DJ

Aims. The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). . Patients and Methods. From our hospital’s prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients’ medical records and radiographs were examined and the relevant data extracted. Post-operative periprosthetic fractures were classified using the Vancouver system. A total of 5417 revision THAs were identified. Results. There were 668 intra-operative fractures, giving an incidence of 12%. Fractures were three times more common with uncemented stems (19%) than with cemented stems (6%) (p <  0.001). The incidence of intra-operative femoral fracture varied by uncemented stem type: fully-coated (20%); proximally-coated (19%); modular fluted tapered (16%) (p < 0.05). Most fractures occurred during the insertion of the femoral component (35%). One-third involved the diaphysis and 26% were of the calcar: 69% were undisplaced. There were 281 post-operative fractures of the femur (20-year probability = 11%). There was no difference in risk for cemented and uncemented stems. Post-operative fractures were more common in men < 70 years (p = 0.02). Periprosthetic fractures occurred earlier after uncemented revision of the femoral component, but later after a cemented revision. The most common fracture type was a Vancouver B. 1. (31%). Of all post-operative fractures, 24% underwent open reduction and internal fixation and 15% revision arthroplasty. Conclusion. In revision THA, intra-operative fractures occurred three times more often with an uncemented stem. Many were undisplaced diaphyseal fractures treated with cerclage fixation. . While the risk of post-operative fracture is similar between uncemented and cemented components, they occur at notably different times depending on the type of stem fixation. . Take home message: In revision THA, intra-operative periprosthetic femoral fractures occur three times more often with uncemented stems. Many are non-displaced diaphyseal fractures treated with cerclage fixation. While postoperative fracture risks are equivalent between uncemented and cemented components, they occur at notably different time periods based on stem fixation type. Cite this article: Bone Joint J 2016;98-B:468–74


Aims. The aim of this study was to assess the reproducibility and validity of cross table radiographs for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) and to compare it with measurements using CT scans. Patients and Methods. A total of 29 patients who underwent THA between June 2010 and January 2016 were included. There were 17 men and 12 women. Their mean age was 43 years (26 to 65). Seven patients underwent a bilateral procedure. Thus, 36 THAs were included in the study. Lateral radiographs and CT scans were obtained post-operatively and radiographs repeated three weeks later. The anteversion of the acetabular component was measured using the method described by Woo and Morrey and the ischiolateral method described by Pulos et al and these were compared with the results obtained from CT scans. Results. The mean anteversion was 18.35° (3° to 38°) using Woo and Morrey’s method, 51.45° (30° to 85°) using the ischiolateral method and 21.22° (2° to 48°) using CT scans. The Pearson correlation coefficient was 0.754 for Woo and Morrey’s method and 0.925 for the ischiolateral method. There was a linear correlation between the measurements using the ischiolateral method and those using CT scans. We derived a simple linear equation between the value of the CT scan and that of ischiolateral method to deduce the CT scan value from that of ischiolateral method and vice versa. . Conclusion. The anteversion of the acetabular component measured using both plain radiographic methods was consistently valid with good interobserver reproducibility, but the ischiolateral method which is independent of pelvic tilt was more accurate. As CT is costly, associated with a high dose of radiation and not readily available, the ischiolateral method can be used for assessing the anteversion of the acetabular component. Cite this article: Bone Joint J 2017;99-B:1006–11


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1232 - 1236
1 Sep 2015
Shafafy R McClatchie W Chettiar K Gill K Hargrove R Sturridge S Guyot A

Infection is a leading indication for revision arthroplasty. Established criteria used to diagnose prosthetic joint infection (PJI) include a range of laboratory tests. Leucocyte esterase (LE) is widely used on a colorimetric reagent strip for the diagnosis of urinary tract infections. This inexpensive test may be used for the diagnosis or exclusion of PJI. Aspirates from 30 total hip arthroplasties (THAs) and 79 knee arthroplasties (KA) were analysed for LE activity. Semi-quantitative reagent strip readings of 15, 70, 125 and 500 white blood cells (WBC) were validated against a manual synovial white cell count (WCC). A receiver operating characteristic (ROC) curve was constructed to determine the optimal cut-off point for the semi-quantitative results. Based on established criteria, six THAs and 15 KAs were classified as infected. The optimal cut-off point for the diagnosis of PJI was 97 WBC. The closest semi-quantitative reading for a positive result was 125 WBC, achieving a sensitivity of 81% and a specificity of 93%. The positive and negative predictive values of the LE test strip were 74% and 95% respectively. The LE reagent strip had a high specificity and negative predictive value. A negative result may exclude PJI and negate the need for further diagnostic tests. Cite this article: Bone Joint J 2015;97-B:1232–6


Bone & Joint Open
Vol. 3, Issue 7 | Pages 543 - 548
7 Jul 2022
Singh V Anil U Kurapatti M Robin JX Schwarzkopf R Rozell JC

Aims

Although readmission has historically been of primary interest, emergency department (ED) visits are increasingly a point of focus and can serve as a potentially unnecessary gateway to readmission. This study aims to analyze the difference between primary and revision total joint arthroplasty (TJA) cases in terms of the rate and reasons associated with 90-day ED visits.

Methods

We retrospectively reviewed all patients who underwent TJA from 2011 to 2021 at a single, large, tertiary urban institution. Patients were separated into two cohorts based on whether they underwent primary or revision TJA (rTJA). Outcomes of interest included ED visit within 90-days of surgery, as well as reasons for ED visit and readmission rate. Multivariable logistic regressions were performed to compare the two groups while accounting for all statistically significant demographic variables.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 8 - 11
1 Jan 2022
Wright-Chisem J Elbuluk AM Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Dislocation following total hip arthroplasty (THA) is a well-known and potentially devastating complication. Clinicians have used many strategies in attempts to prevent dislocation since the introduction of THA. While the importance of postoperative care cannot be ignored, particular emphasis has been placed on preoperative planning in the prevention of dislocation. The strategies have progressed from more traditional approaches, including modular implants, the size of the femoral head, and augmentation of the offset, to newer concepts, including patient-specific component positioning combined with computer navigation, robotics, and the use of dual-mobility implants. As clinicians continue to pursue improved outcomes and reduced complications, these concepts will lay the foundation for future innovation in THA and ultimately improved outcomes.

Cite this article: Bone Joint J 2022;104-B(1):8–11.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 917 - 923
1 Jul 2015
Singh G Nuechtern JV Meyer H Fiedler GM Awiszus F Junk-Jantsch S Bruegel M Pflueger G Lohmann CH

The peri-prosthetic tissue response to wear debris is complex and influenced by various factors including the size, area and number of particles. We hypothesised that the ‘biologically active area’ of all metal wear particles may predict the type of peri-prosthetic tissue response. . Peri-prosthetic tissue was sampled from 21 patients undergoing revision of a small diameter metal-on-metal (MoM) total hip arthroplasty (THA) for aseptic loosening. An enzymatic protocol was used for tissue digestion and scanning electron microscope was used to characterise particles. Equivalent circle diameters and particle areas were calculated. Histomorphometric analyses were performed on all tissue specimens. Aspirates of synovial fluid were collected for analysis of the cytokine profile analysis, and compared with a control group of patients undergoing primary THA (n = 11) and revision of a failed ceramic-on-polyethylene arthroplasty (n = 6). . The overall distribution of the size and area of the particles in both lymphocyte and non-lymphocyte-dominated responses were similar; however, the subgroup with lymphocyte-dominated peri-prosthetic tissue responses had a significantly larger total number of particles. . 14 cytokines (interleukin (IL)-1ß, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, IL-17, interferon (IFN)-γ, and IFN-gamma-inducible protein 10), chemokines (macrophage inflammatory protein (MIP)-1α and MIP-1ß), and growth factors (granulocyte macrophage colony stimulating factor (GM-CSF) and platelet derived growth factor) were detected at significantly higher levels in patients with metal wear debris compared with the control group. . Significantly higher levels for IL-1ß, IL-5, IL-10 and GM-CSF were found in the subgroup of tissues from failed MoM THAs with a lymphocyte-dominated peri-prosthetic response compared with those without this response. . These results suggest that the ‘biologically active area’ predicts the type of peri-prosthetic tissue response. The cytokines IL-1ß, IL-5, IL-10, and GM-CSF are associated with lymphocyte-dominated tissue responses from failed small-diameter MoM THA. Cite this article: Bone Joint J 2015;97-B:917–23


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 607 - 613
1 May 2017
Mäkinen TJ Abolghasemian M Watts E Fichman SG Kuzyk P Safir OA Gross AE

Aims. It may not be possible to undertake revision total hip arthroplasty (THA) in the presence of massive loss of acetabular bone stock using standard cementless hemispherical acetabular components and metal augments, as satisfactory stability cannot always be achieved. We aimed to study the outcome using a reconstruction cage and a porous metal augment in these patients. Patients and Methods. A total of 22 acetabular revisions in 19 patients were performed using a combination of a reconstruction cage and porous metal augments. The augments were used in place of structural allografts. The mean age of the patients at the time of surgery was 70 years (27 to 85) and the mean follow-up was 39 months (27 to 58). The mean number of previous THAs was 1.9 (1 to 3). All patients had segmental defects involving more than 50% of the acetabulum and seven hips had an associated pelvic discontinuity. . Results. Three failures were observed in two hips, both of which had undergone a previous resection of a tumour affecting the acetabulum. Other complications included a late arterial injury, a sciatic nerve palsy, a dislocation treated with a femoral revision, a deep infection treated with irrigation and debridement and a fracture of the greater trochanter treated conservatively. The mean Oxford Hip Score significantly increased from 13.9 (2 to 23) to 28.7 (13 to 38) (p < 0.00001). The mean vertical distance between the centre of rotation of the hip and its normal location decreased from 30 mm to 10 mm. Conclusions. Acceptable early survivorship can be achieved using this novel technique, but it may be unsuitable for use in patients who have previously undergone the resection of a tumour involving the acetabulum. Cite this article: Bone Joint J 2017;99-B:607–13