To examine the mid-term outcome and cost utility of the BioPro
metallic hemiarthroplasty for the treatment of hallux rigidius. We reviewed 97 consecutive BioPro metallic hemiarthroplasties
performed in 80 patients for end-stage hallux rigidus, with a minimum
follow-up of five years. There were 19 men and 61 women; their mean
age was 55 years (22 to 74). No patient was lost to follow-up.Aims
Patients and Methods
The aims of our study were to provide long-term information on
the behaviour of the thoracolumbar/lumbar (TL/L) curve after thoracic
anterior correction and fusion (ASF) and to determine the impact
of ASF on pulmonary function. A total of 41 patients (four males, 37 females) with main thoracic
(MT) adolescent idiopathic scoliosis (AIS) treated with ASF were
included. Mean age at surgery was 15.2 years (11 to 27). Mean follow-up
period was 13.5 years (10 to 18).Aims
Patients and Methods
We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p <
0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.
We assessed the effect of mental disability on
the outcome of total knee replacement (TKR) and investigated whether
mental health improves post-operatively. Outcome data were prospectively
recorded over a three-year period for 962 patients undergoing primary
TKR for osteoarthritis. Pre-operative and one year Short-Form (SF)-12 scores
and Oxford knee scores (OKS) were obtained. The mental component
of the SF-12 was stratified into four groups according to level
of mental disability (none ≥ 50, mild 40 to 49, moderate 30 to 39,
severe <
30). Patients with any degree of mental disability had
a significantly greater subjective physical disability according
to the SF-12 (p = 0.06) and OKS (p <
0.001). The improvement
in the disease-specific score (OKS) was not affected by a patient’s
mental health (p = 0.33). In contrast, patients with mental disability
had less of an improvement in their global physical health (SF-12)
(p <
0.001). However, patients with any degree of mental disability
had a significant improvement in their mental health post-operatively
(p <
0.001). Despite a similar improvement in their disease-specific scores
and improvement in their mental health, patients with mental disability
were significantly more likely to be dissatisfied with their TKR
at one year (p = 0.001). Patients with poor mental health do benefit
from improvements in their mental health and knee function after
TKR, but also have a higher rate of dissatisfaction. Cite this article:
We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Metasul articulation or bearing and a titanium plasma-sprayed coating for fixation of the acetabular component. Although significantly higher blood ion levels of Cr and Co were observed at three months in the resurfaced group than in total hip replacement, no significant difference was found at two years post-operatively for Cr, 1.58 μg/L and 1.62 μg/L respectively (p = 0.819) and for Co, 0.67 μg/L and 0.94 μg/L respectively (p = 0.207). A steady state was reached at one year in the resurfaced group and after three months in the total hip replacement group. Interestingly, Ti, which is not part of the bearing surfaces with its release resulting from metal corrosion, had significantly elevated ion levels after implantation in both groups. The hip resurfacing group had significantly higher Ti levels than the total hip replacement group for all periods of follow-up. At two years the mean blood levels of Ti ions were 1.87 μg/L in hip resurfacing and and 1.30 μg/L in total hip replacement (p = 0.001). The study confirms even with different bearing diameters and clearances, hip replacement and 28 mm metal-on-metal total hip replacement produced similar Cr and Co metal ion levels in this randomised controlled trial study design, but apart from wear on bearing surfaces, passive corrosion of exposed metallic surfaces is a factor which influences ion concentrations. Ti plasma spray coating the acetabular components for hip resurfacing produces significantly higher release of Ti than Ti grit-blasted surfaces in total hip replacement.
Fractures of the tibial shaft are common injuries,
but there are no long-term outcome data in the era of increased surgical
management. The aim of this prospective study was to assess the
clinical and functional outcome of this injury at 12 to 22 years.
Secondary aims were to determine the short- and long-term mortality,
and if there were any predictors of clinical or functional outcome
or mortality. From a prospective trauma database of 1502 tibial
shaft fractures in 1474 consecutive adult patients, we identified
a cohort of 1431 tibial diaphyseal fractures in 1403 patients, who
fitted our inclusion criteria. There were 1024 men, and mean age
at injury was 40.6 years. Fractures were classified according to
the AO system, and open fractures graded after Gustilo and Anderson.
Requirement of fasciotomy, time to fracture union, complications,
incidence of knee and ankle pain at long-term follow-up, changes in
employment and the patients’ social deprivation status were recorded.
Function was assessed at 12 to 22 years post-injury using the Short
Musculoskeletal Function Assessment and short form-12 questionnaires.
Long-term functional outcome data was available for 568 of the surviving
patients, 389 were deceased and 346 were lost to follow-up. Most
fractures (90.7%, n = 1363) united without further intervention.
Fasciotomies were performed in 11.5% of patients; this did not correlate
with poorer functional outcome in the long term. Social deprivation
was associated with a higher incidence of injury but had no impact
on long-term function. The one-year mortality in those over 75 years
of age was 29 (42%). At long-term follow-up, pain and function scores
were good. However, 147 (26%) reported ongoing knee pain, 62 (10%)
reported ankle pain and 97 (17%) reported both. Such joint pain correlated
with poorer functional outcome. Cite this article:
The β-angle is a radiological tool for measuring the distance between the pathological head-neck junction and the acetabular rim with the hip in 90° of flexion in patients with femoroacetabular impingement. Initially it was measured using an open-chamber MRI. We have developed a technique to measure this angle on plain radiographs. Correlation analysis was undertaken to determine the relationship between the range of movement and the β-angle in 50 patients with femoroacetabular impingement and 50 asymptomatic control subjects. Inter- and intra-observer reliability of the β-angle was also evaluated. Patients with femoroacetabular impingement had a significantly smaller (p <
0.001) mean β-angle (15.6°, 95% confidence interval (CI) 13.3 to 17.7) compared with the asymptomatic group (38.7°, 95% CI 36.5 to 41.0). Correlation between internal rotation and the β-angle was high in the impingement group and moderate in the asymptomatic group. The β-angle had excellent inter- and intra-observer reliability in both groups. Our findings suggest that the measurement of the β-angle on plain radiography may represent a valid, reproducible and cost-effective alternative to open MRI in the assessment of the pathological bony anatomy in patients with cam, pincer and mixed femoroacetabular impingement.
The primary aim of this study was to investigate the effect of
an enhanced recovery program (ERP) on the short-term functional
outcome after total hip arthroplasty (THA). Secondary outcomes included
its effect on rates of dislocation and mortality. Data were gathered on 1161 patients undergoing primary THA which
included 611 patients treated with traditional rehabilitation and
550 treated with an ERP. Aims
Patients and Methods
We measured the tension in the interosseous membrane
in six cadaveric forearms using an Cite this article:
One commonly used rat fracture model for bone and mineral research
is a closed mid-shaft femur fracture as described by Bonnarens in
1984. Initially, this model was believed to create very reproducible
fractures. However, there have been frequent reports of comminution
and varying rates of complication. Given the importance of precise
anticipation of those characteristics in laboratory research, we
aimed to precisely estimate the rate of comminution, its importance and
its effect on the amount of soft callus created. Furthermore, we
aimed to precisely report the rate of complications such as death
and infection. We tested a rat model of femoral fracture on 84 rats based on
Bonnarens’ original description. We used a proximal approach with
trochanterotomy to insert the pin, a drop tower to create the fracture
and a high-resolution fluoroscopic imager to detect the comminution.
We weighed the soft callus on day seven and compared the soft callus
parameters with the comminution status.Objectives
Methods
We conducted a multicentre cohort study of 228 patients with osteoarthritis followed up after total hip or knee replacement. Quality of life and patient satisfaction were assessed by self-administered questionnaires. Patient satisfaction was the dependent variable in a multivariate linear regression model. Independent variables included sociodemographic factors, pre- and post-operative clinical characteristics and the pre-operative and post-discharge health-related quality of life. The mean age of the patients was 69 years ( The pre-operative health-related quality of life and patient characteristics have little effect on inpatient satisfaction with care. This suggests that the impact of the care process on satisfaction may be independent of observed and perceived initial patient-related characteristics.
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range. Bone mineral density measured
at the proximal femur and the position of the screws in the subchondral
region, correlated with slight progressive radial shortening, which
was not clinically relevant. Volar locking plating of distal radial fractures is a reliable
form of treatment without substantial late displacement. Cite this article:
The goals of this study were: 1) to determine if high-fat diet
(HFD) feeding in female mice would negatively impact biomechanical
and histologic consequences on the Achilles tendon and quadriceps
muscle; and 2) to investigate whether exercise and branched-chain
amino acid (BCAA) supplementation would affect these parameters
or attenuate any negative consequences resulting from HFD consumption. We examined the effects of 16 weeks of 60% HFD feeding, voluntary
exercise (free choice wheel running) and BCAA administration in
female C57BL/6 mice. The Achilles tendons and quadriceps muscles
were removed at the end of the experiment and assessed histologically
and biomechanically.Objectives
Methods
The aim of this prospective study was to investigate
prematurity as a risk factor for developmental dysplasia of the hip
(DDH). The hips of 221 infants (88 female, 133 male, mean age 31.11
weeks; standard deviation ( These results suggests that prematurity is not a predisposing
factor for DDH. Cite this article:
We compared the accuracy of the growth remaining
method of assessing leg-length discrepancy (LLD) with the straight-line
graph method, the multiplier method and their variants. We retrospectively
reviewed the records of 44 patients treated by percutaneous epiphysiodesis
for LLD. All were followed up until maturity. We used the modified Green–Anderson
growth-remaining method (Method 1) to plan the timing of epiphysiodesis.
Then we presumed that the other four methods described below were
used pre-operatively for calculating the timing of epiphysiodesis. We
then assumed that these four methods were used pre-operatively.
Method 2 was the original Green–Anderson growth-remaining method;
Method 3, Paley’s multiplier method using bone age; Method 4, Paley’s
multiplier method using chronological age; and Method 5, Moseley’s
straight-line graph method. We compared ‘Expected LLD at maturity
with surgery’ with ‘Final LLD at maturity with surgery’ for each
method. Statistical analysis revealed that ‘Expected LLD at maturity
with surgery’ was significantly different from ‘Final LLD at maturity
with surgery’. Method 2 was the most accurate. There was a significant
correlation between ‘Expected LLD at maturity with surgery’ and
‘Final LLD at maturity with surgery’, the greatest correlation being
with Method 2. Generally all the methods generated an overcorrected
value. No method generates the precise ‘Expected LLD at maturity
with surgery’. It is essential that an analysis of the pattern of
growth is taken into account when predicting final LLD. As many
additional data as possible are required. Cite this article:
We describe the outcome of tibial diaphyseal
fractures in the elderly (≥ 65 years of age). We prospectively followed 233
fractures in 225 elderly patients over a minimum ten-year period.
Demographic and descriptive data were acquired from a prospective
trauma database. Mortality status was obtained from the General
Register Office database for Scotland. Diaphyseal fractures of the
tibia in the elderly occurred predominantly in women (73%) and after
a fall (61%). During the study period the incidence of these fractures
decreased, nearly halving in number. The 120-day and one-year unadjusted
mortality rates were 17% and 27%, respectively, and were significantly
greater in patients with an open fracture (p <
0.001). The overall
standardised mortality ratio (SMR) was significantly increased (SMR
4.4, p <
0.001) relative to the population at risk, and was greatest
for elderly women (SMR 8.1, p <
0.001). These frailer patients
had more severe injuries, with an increased rate of open fractures
(30%), and suffered a greater rate of nonunion (10%). Tibial diaphyseal fractures in the elderly are most common in
women after a fall, are more likely to be open than in the rest
of the population, and are associated with a high incidence of nonunion
and mortality. Cite this article:
Between 1999 and 2001, 90 patients underwent
total hip replacement using the same uncemented acetabular and femoral
components with a 28 mm metallic femoral head but with prospective
randomisation of the acetabular liner to either Durasul highly cross-linked
polyethylene or nitrogen-sterilised Sulene polyethylene. We assessed
83 patients at a minimum follow-up of ten years. Linear penetration
of the femoral head was estimated at six weeks, six and 12 months
and annually thereafter, using the Dorr method, given the non-spherical
shape of the acetabular component. There was no loosening of any component; only one hip in the
Sulene group showed proximal femoral osteolysis. The mean penetration
of the femoral head at six weeks was 0.08 mm (0.02 to 0.15) for
the Durasul group and 0.16 mm (0.05 to 0.28) for the Sulene group
(p = 0.001). The mean yearly linear penetration was 64.8% lower
for the Durasul group at 0.05 mm/year ( Cite this article:
Flexor digitorum longus transfer and medial displacement
calcaneal osteotomy is a well-recognised form of treatment for stage
II posterior tibial tendon dysfunction. Although excellent short-
and medium-term results have been reported, the long-term outcome
is unknown. We reviewed the clinical outcome of 31 patients with
a symptomatic flexible flat-foot deformity who underwent this procedure
between 1994 and 1996. There were 21 women and ten men with a mean
age of 54.3 years (42 to 70). The mean follow-up was 15.2 years
(11.4 to 16.5). All scores improved significantly (p <
0.001).
The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved
from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up.
The mean pain component improved from 12.3 to 35.2 (20 to 40). The
mean function score improved from 35.2 to 45.6 (30 to 50). The mean
visual analogue score for pain improved from 7.3 to 1.3 (0 to 6).
The mean Short Form-36 physical component score was 40.6 ( Cite this article:
In In a hip fracture experiment, nine pairs of human cadaver femurs
were tested in a paired study design. The femurs were then re-matched
according to BMD, creating two new test groups. Intra-pair variance
and paired correlations in fixation stability were calculated. A
hypothetical power analysis was then performed to explore the required sample
size for the two types of group allocation. Objective
Methods
This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003. The mean rotation of the tibial component was 4.3° of internal rotation (25.4° internal to 13.9° external rotation) in the painful group and 2.2° of external rotation (8.5° internal to 18.2° external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9° compared with none in the painfree group (p <
0.001). Additionally, six femoral components in the painful group were internally rotated more than 6° compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain. Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.