Advertisement for orthosearch.org.uk
Results 201 - 220 of 3341
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1736 - 1741
1 Nov 2021
Tolk JJ Eastwood DM Hashemi-Nejad A

Aims. Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths. Methods. All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total leg length, femoral and tibial length, articulotrochanteric distance (ATD), and subtrochanteric femoral length were compared between PD side and the unaffected side. Furthermore, we compared leg length measurements between patients who did and who did not have a contralateral epiphysiodesis. Results. Overall, 79 patients were included, of whom 21 underwent contralateral epiphysiodesis for leg length correction. In the complete cohort, the mean LLD was 1.8 cm (95% confidence interval (CI) 1.5 to 2.0), mean ATD difference was 1.8 cm (95% CI -2.1 to -1.9), and mean subtrochanteric difference was -0.2 cm (95% CI -0.4 to 0.1). In the epiphysiodesis group, the mean LLD before epiphysiodesis was 2.7 cm (95% CI 1.3 to 3.4) and 1.3 cm (95% CI -0.5 to 3.8) at skeletal maturity. In the nonepiphysiodesis group the mean LLD was 2.0 cm (95% CI 0.5 to 5.1; p = 0.016). The subtrochanteric region on the PD side was significantly longer at skeletal maturity in the epiphysiodesis group compared to the nonepiphysiodesis group (-1.0 cm (95% CI -2.4 to 0.6) vs 0.1 cm (95% CI -1.0 to 2.1); p < 0.001). Conclusion. This study demonstrates that LLD after PD originates from the proximal segment only. In patients who had contralateral epiphysiodesis to balance leg length, this is achieved by creating a difference in subtrochanteric length. Arthroplasty surgeons need to be aware that shortening of the proximal femur segment in PD patients may be misleading, as the ipsilateral subtrochanteric length in these patients can be longer. Therefore, we strongly advise long-leg standing films for THA planning in PD patients in order to avoid inadvertently lengthening the limb. Cite this article: Bone Joint J 2021;103-B(11):1736–1741


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1351 - 1357
1 Aug 2021
Sun J Chhabra A Thakur U Vazquez L Xi Y Wells J

Aims. Some patients presenting with hip pain and instability and underlying acetabular dysplasia (AD) do not experience resolution of symptoms after surgical management. Hip-spine syndrome is a possible underlying cause. We hypothesized that there is a higher frequency of radiological spine anomalies in patients with AD. We also assessed the relationship between radiological severity of AD and frequency of spine anomalies. Methods. In a retrospective analysis of registry data, 122 hips in 122 patients who presented with hip pain and and a final diagnosis of AD were studied. Two observers analyzed hip and spine variables using standard radiographs to assess AD. The frequency of lumbosacral transitional vertebra (LSTV), along with associated Castellvi grade, pars interarticularis defect, and spinal morphological measurements were recorded and correlated with radiological severity of AD. Results. Out of 122 patients, 110 (90.2%) were female and 12 (9.8%) were male. We analyzed the radiographs of 122 hips (59 (48.4%) symptomatic left hips, and 63 (51.6%) symptomatic right hips). Average age at time of presentation was 34.2 years (SD 11.2). Frequency of LSTV was high (39% to 43%), compared to historic records from the general population, with Castellvi type 3b being the most common (60% to 63%). Patients with AD have increased L4 and L5 interpedicular distance compared to published values. Frequency of pars interarticularis defect was 4%. Intraclass correlation coefficient for hip and spine variables assessed ranged from good (0.60 to 0.75) to excellent (0.75 to 1.00). Severity of AD did not demonstrate significant correlation with frequency of radiological spine anomalies. Conclusion. Patients with AD have increased frequency of spinal anomalies seen on standard hip radiographs. However, there exists no correlation between radiological severity of AD and frequency of spine anomalies. In managing AD patients, clinicians should also assess spinal anomalies that are easily found on standard hip radiographs. Cite this article: Bone Joint J 2021;103-B(8):1351–1357


Bone & Joint Open
Vol. 2, Issue 7 | Pages 493 - 502
12 Jul 2021
George SZ Yan X Luo S Olson SA Reinke EK Bolognesi MP Horn ME

Aims. Patient-reported outcome measures have become an important part of routine care. The aim of this study was to determine if Patient-Reported Outcomes Measurement Information System (PROMIS) measures can be used to create patient subgroups for individuals seeking orthopaedic care. Methods. This was a cross-sectional study of patients from Duke University Department of Orthopaedic Surgery clinics (14 ambulatory and four hospital-based). There were two separate cohorts recruited by convenience sampling (i.e. patients were included in the analysis only if they completed PROMIS measures during a new patient visit). Cohort #1 (n = 12,141; December 2017 to December 2018,) included PROMIS short forms for eight domains (Physical Function, Pain Interference, Pain Intensity, Depression, Anxiety, Sleep Quality, Participation in Social Roles, and Fatigue) and Cohort #2 (n = 4,638; January 2019 to August 2019) included PROMIS Computer Adaptive Testing instruments for four domains (Physical Function, Pain Interference, Depression, and Sleep Quality). Cluster analysis (K-means method) empirically derived subgroups and subgroup differences in clinical and sociodemographic factors were identified with one-way analysis of variance. Results. Cluster analysis yielded four subgroups with similar clinical characteristics in Cohort #1 and #2. The subgroups were: 1) Normal Function: within normal limits in Physical Function, Pain Interference, Depression, and Sleep Quality; 2) Mild Impairment: mild deficits in Physical Function, Pain Interference, and Sleep Quality but with Depression within normal limits; 3) Impaired Function, Not Distressed: moderate deficits in Physical Function and Pain Interference, but within normal limits for Depression and Sleep Quality; and 4) Impaired Function, Distressed: moderate (Physical Function, Pain Interference, and Sleep Quality) and mild (Depression) deficits. Conclusion. These findings suggest orthopaedic patient subgroups differing in physical function, pain, and psychosocial distress can be created from as few as four different PROMIS measures. Longitudinal research is necessary to determine whether these subgroups have prognostic validity. Cite this article: Bone Jt Open 2021;2(7):493–502


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 17 - 24
1 Jul 2021
Vigdorchik JM Sharma AK Buckland AJ Elbuluk AM Eftekhary N Mayman DJ Carroll KM Jerabek SA

Aims. Patients with spinal pathology who undergo total hip arthroplasty (THA) have an increased risk of dislocation and revision. The aim of this study was to determine if the use of the Hip-Spine Classification system in these patients would result in a decreased rate of postoperative dislocation in patients with spinal pathology. Methods. This prospective, multicentre study evaluated 3,777 consecutive patients undergoing THA by three surgeons, between January 2014 and December 2019. They were categorized using The Hip-Spine Classification system: group 1 with normal spinal alignment; group 2 with a flatback deformity, group 2A with normal spinal mobility, and group 2B with a stiff spine. Flatback deformity was defined by a pelvic incidence minus lumbar lordosis of > 10°, and spinal stiffness was defined by < 10° change in sacral slope from standing to seated. Each category determined a patient-specific component positioning. Survivorship free of dislocation was recorded and spinopelvic measurements were compared for reliability using intraclass correlation coefficient. Results. A total of 2,081 patients met the inclusion criteria. There were 987 group 1A, 232 group 1B, 715 group 2A, and 147 group 2B patients. A total of 70 patients had a lumbar fusion, most had L4-5 (16; 23%) or L4-S1 (12; 17%) fusions; 51 patients (73%) had one or two levels fused, and 19 (27%) had > three levels fused. Dual mobility (DM) components were used in 166 patients (8%), including all of those in group 2B and with > three level fusions. Survivorship free of dislocation at five years was 99.2% with a 0.8% dislocation rate. The correlation coefficient was 0.83 (95% confidence interval 0.89 to 0.91). Conclusion. This is the largest series in the literature evaluating the relationship between hip-spine pathology and dislocation after THA, and guiding appropriate treatment. The Hip-Spine Classification system allows surgeons to make appropriate evaluations preoperatively, and it guides the use of DM components in patients with spinopelvic pathology in order to reduce the risk of dislocation in these high-risk patients. Cite this article: Bone Joint J 2021;103-B(7 Supple B):17–24


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims. Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). Methods. We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11). Results. Overall, 80 synovial fluid samples of 40 patients were analyzed. The average time period between the joint aspirations was 50 days (SD 32). There was a significantly higher percentage change in LC when compared to PMN% (44.1% (SD 28.6%) vs 27.3% (SD 23.7%); p = 0.003). When applying standard definition criteria, LC counts were found to skip back and forth between the two time points with exceeding the thresholds in up to 20% of cases, which was significantly more compared to PMN% for the European Bone and Joint Infection Society (EBJIS) criteria (p = 0.001), as well as for Musculoskeletal Infection Society (MSIS) (p = 0.029). Conclusion. LC and PMN% are subject to considerable variation. According to its higher interindividual variance, LC evaluation might contribute to false-positive or false-negative results in PJI assessment. Single LC testing prior to TKA revision surgery seems to be insufficient to exclude PJI. On the basis of the obtained results, PMN% analyses overrule LC measurements with regard to a conclusive diagnostic algorithm. Cite this article: Bone Jt Open 2021;2(8):566–572


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 348 - 352
1 Mar 2019
Patel S Malhotra K Cullen NP Singh D Goldberg AJ Welck MJ

Aims. Cone beam CT allows cross-sectional imaging of the tibiofibular syndesmosis while the patient bears weight. This may facilitate more accurate and reliable investigation of injuries to, and reconstruction of, the syndesmosis but normal ranges of measurements are required first. The purpose of this study was to establish: 1) the normal reference measurements of the syndesmosis; 2) if side-to-side variations exist in syndesmotic anatomy; 3) if age affects syndesmotic anatomy; and 4) if the syndesmotic anatomy differs between male and female patients in weight-bearing cone beam CT views. Patients and Methods. A retrospective analysis was undertaken of 50 male and 50 female patients (200 feet) aged 18 years or more, who underwent bilateral, simultaneous imaging of their lower legs while standing in an upright, weight-bearing position in a pedCAT machine between June 2013 and July 2017. At the time of imaging, the mean age of male patients was 47.1 years (18 to 72) and the mean age of female patients was 57.8 years (18 to 83). We employed a previously described technique to obtain six lengths and one angle, as well as calculating three further measurements, to provide information on the relationship between the fibula and tibia with respect to translation and rotation. Results. The upper limit of lateral translation in un-injured patients was 5.27 mm, so values higher than this may be indicative of syndesmotic injury. Anteroposterior translation lay within the ranges 0.31 mm to 2.59 mm, and -1.48 mm to 3.44 mm, respectively. There was no difference between right and left legs. Increasing age was associated with a reduction in lateral translation. The fibulae of men were significantly more laterally translated but data were inconsistent for rotation and anteroposterior translation. Conclusion. We have established normal ranges for measurements in cross-sectional syndesmotic anatomy during weight-bearing and also established that no differences exist between right and left legs in patients without syndesmotic injury. Age and gender do, however, affect the anatomy of the syndesmosis, which should be taken into account at time of assessment. Cite this article: Bone Joint J 2019;101-B:348–352


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 964 - 970
1 May 2021
Ling DI Schneider B Ode G Lai EY Gulotta LV

Aims. To investigate the impact of the Charlson and Elixhauser comorbidity indices on patient-reported outcomes measures (PROMs) following shoulder arthroplasty. Methods. Patients undergoing total shoulder arthroplasty (TSA), reverse shoulder arthroplasty (RSA), or hemiarthroplasty (HA) from 2016 to 2018 were identified, along with the Charlson and Elixhauser comorbidities listed as their secondary diagnoses in the electronic medical records. Patients were matched to our institution’s registry to obtain their PROMs, including shoulder-specific (American Shoulder and Elbow Society (ASES) and Shoulder Activity Scale (SAS)) and general health scales (12-Item Short Form Survey (SF-12) and Patient-Reported Outcomes Measurement Information System-Pain Interference). Linear regression models adjusting for age and sex were used to evaluate the association between increasing number of comorbidities and PROM scores. A total of 1,817 shoulder arthroplasties were performed: 1,017 (56%) TSA, 726 (40%) RSA, and 74 (4%) HA. The mean age was 67 years (SD 10), and 936 (52%) of the patients were female. Results. The most common comorbidities were obesity (1,256, 69%) and hypertension (990, 55%). Patients with more comorbidities had lower ASES and SAS scores at baseline (p < 0.001). Elixhauser comorbidities continued to negatively impact ASES and SAS scores at one year (p = 0.002) and two-year follow-up (p = 0.002). Patients with more comorbidities reported greater pain interference on PROMIS at baseline (p = 0.007), but not at two years. Higher number of Charlson comorbidities were associated with lower scores on the SF-12 mental component at baseline (p < 0.001) and two years (p = 0.020). Higher number of Elixhauser comorbidities were associated with lower SF-12 physical component scores at baseline (p < 0.001) and two years (p = 0.004). Conclusion. Higher number of comorbidities was associated with lower baseline scores and worse outcomes on both shoulder-specific and general health PROMs. The presence of specific comorbidities may be used during shared decision-making to manage expectations for patients undergoing shoulder arthroplasty. Cite this article: Bone Joint J 2021;103-B(5):964–970


Bone & Joint Research
Vol. 10, Issue 9 | Pages 611 - 618
27 Sep 2021
Ali E Birch M Hopper N Rushton N McCaskie AW Brooks RA

Aims. Accumulated evidence indicates that local cell origins may ingrain differences in the phenotypic activity of human osteoblasts. We hypothesized that these differences may also exist in osteoblasts harvested from the same bone type at periarticular sites, including those adjacent to the fixation sites for total joint implant components. Methods. Human osteoblasts were obtained from the acetabulum and femoral neck of seven patients undergoing total hip arthroplasty (THA) and from the femoral and tibial cuts of six patients undergoing total knee arthroplasty (TKA). Osteoblasts were extracted from the usually discarded bone via enzyme digestion, characterized by flow cytometry, and cultured to passage three before measurement of metabolic activity, collagen production, alkaline phosphatase (ALP) expression, and mineralization. Results. Osteoblasts from the acetabulum showed lower proliferation (p = 0.034), cumulative collagen release (p < 0.001), and ALP expression (p = 0.009), and produced less mineral (p = 0.006) than those from the femoral neck. Osteoblasts from the tibia produced significantly less collagen (p = 0.021) and showed lower ALP expression than those from the distal femur. Conclusion. We have demonstrated for the first time an anatomical regional variation in the biological behaviours of osteoblasts on either side of the hip and knee joint. The lower osteoblast proliferation, matrix production, and mineralization from the acetabulum compared to those from the proximal femur may be reflected in differences in bone formation and implant fixation at these sites. Cite this article: Bone Joint Res 2021;10(9):611–618


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement. Results. Demographic data were similar between groups with the exception of BMI being lower in the NSA group (27.98 vs 25.2; p = 0.005). Operating time and total time in operating room (TTOR) was lower in the SSA (p < 0.001) and TTOR was higher in the NSP group (p = 0.014). Planned versus postoperative leg length discrepancy were similar among both anterior and posterior surgeries (p > 0.104). Planned versus postoperative abduction and anteversion were similar among the NSA and SSA (p > 0.425), whereas planned versus postoperative abduction and anteversion were lower in the NSP (p < 0.001). Outliers > 10 mm from planned leg length were present in one case of the SSP and NSP, with none in the anterior groups. There were no outliers > 10° in anterior or posterior for abduction in all surgeons. The SSP had six outliers > 10° in anteversion while the NSP had none (p = 0.004); the SSA had no outliers for anteversion while the NSA had one (p = 0.500). Conclusion. Robotic arm-assisted technology allowed a newly trained surgeon to produce similarly accurate results and outcomes as experienced surgeons in anterior and posterior hip arthroplasty. Cite this article: Bone Jt Open 2021;2(6):365–370


Bone & Joint Research
Vol. 10, Issue 3 | Pages 173 - 187
1 Mar 2021
Khury F Fuchs M Awan Malik H Leiprecht J Reichel H Faschingbauer M

Aims. To explore the clinical relevance of joint space width (JSW) narrowing on standardized-flexion (SF) radiographs in the assessment of cartilage degeneration in specific subregions seen on MRI sequences in knee osteoarthritis (OA) with neutral, valgus, and varus alignments, and potential planning of partial knee arthroplasty. Methods. We retrospectively reviewed 639 subjects, aged 45 to 79 years, in the Osteoarthritis Initiative (OAI) study, who had symptomatic knees with Kellgren and Lawrence grade 2 to 4. Knees were categorized as neutral, valgus, and varus knees by measuring hip-knee-angles on hip-knee-ankle radiographs. Femorotibial JSW was measured on posteroanterior SF radiographs using a special software. The femorotibial compartment was divided into 16 subregions, and MR-tomographic measurements of cartilage volume, thickness, and subchondral bone area were documented. Linear regression with adjustment for age, sex, body mass index, and Kellgren and Lawrence grade was used. Results. We studied 345 neutral, 87 valgus, and 207 varus knees. Radiological JSW narrowing was significantly (p < 0.01) associated with cartilage volume and thickness in medial femorotibial compartment in neutral (r = 0.78, odds ratio (OR) 2.33) and varus knees (r = 0.86, OR 1.92), and in lateral tibial subregions in valgus knees (r = 0.87, OR 3.71). A significant negative correlation was found between JSW narrowing and area of subchondral bone in external lateral tibial subregion in valgus knees (r = −0.65, p < 0.01) and in external medial tibial subregion in varus knees (r = −0.77, p < 0.01). No statistically significant correlation was found in anterior and posterior subregions. Conclusion. SF radiographs can be potentially used for initial detection of cartilage degeneration as assessed by MRI in medial and lateral but not in anterior or posterior subregions. Cite this article: Bone Joint Res 2021;10(3):173–187


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 411 - 414
1 Feb 2021
Wordie SJ Bugler KE Bessell PR Robb JE Gaston MS

Aims. The migration percentage (MP) is one criterion used for surgery in dislocated or displaced hips in children with cerebral palsy (CP). The MP at which a displaced hip can no longer return to normal is unclear. The aim of this paper was to identify the point of no return of the MP through a large population-based study. Methods. All children registered on the Cerebral Palsy Integrated Pathway Scotland surveillance programme undergo regular pelvic radiographs. Any child who had a MP measuring over 35% since the programme’s inception in 2013, in at least one hip and at one timepoint, was identified. The national radiography database was then interrogated to identify all pelvic radiographs for each of these children from birth through to the date of analysis. A minimum of a further two available radiographs following the initial measurement of MP ≥ 35% was required for inclusion. Results. A total of 239 children (346 hips) were identified as suitable for analysis at a mean of 6.5 years (2.0 to 14.8) follow-up. In all, 1,485 radiographs taken both prior to and after a hip had a MP ≥ 35% were examined and the MP measured to identify any progression of displacement. Interrogation of the data identified that hips with a MP up to 46% returned to a MP below 40% without intervention, and all hips with a MP equal to or greater than 46% displaced further and the MP did not return to the normal range. Statistical analysis showed the result to be 98% specific with this degree of certainty that hips reaching a MP ≥ 46% would not spontaneously regress. Conclusion. These findings are clinically relevant in showing that it may be reasonable to continue to monitor hips with a MP not exceeding 46%. This threshold will also guide referral for further management of a displacing hip. Cite this article: Bone Joint J 2021;103-B(2):411–414


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims. The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). Methods. A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. Results. A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. Conclusion. The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855–863


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 16 - 22
1 Jun 2019
Livermore AT Anderson LA Anderson MB Erickson JA Peters CL

Aims. The aim of this study was to compare patient-reported outcome measures (PROMs), radiological measurements, and total hip arthroplasty (THA)-free survival in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip. Patients and Methods. We performed a retrospective study involving 336 patients (420 hips) who underwent PAO by a single surgeon at an academic centre. After exclusions, 124 patients (149 hips) were included. The preoperative lateral centre-edge angle (LCEA) was used to classify the severity of dysplasia: 18° to 25° was considered mild (n = 20), 10° to 17° moderate (n = 66), and < 10° severe (n = 63). There was no difference in patient characteristics between the groups (all, p > 0.05). Pre- and postoperative radiological measurements were made. The National Institute of Health’s Patient Reported Outcomes Measurement Information System (PROMIS) outcome measures (physical function computerized adaptive test (PF CAT), Global Physical and Mental Health Scores) were collected. Failure was defined as conversion to THA or PF CAT scores < 40, and was assessed with Kaplan–Meier analysis. The mean follow-up was five years (2 to 10) ending in either failure or the latest contact with the patient. Results. There was no significant difference in PROMs for moderate (p = 0.167) or severe (p = 0.708) groups compared with the mild dysplasia group. The numerical pain scores were between 2 and 3 units in all groups at the final follow-up (all, p > 0.05). There was no significant difference (all, p > 0.05) in the proportion of patients achieving target correction for the LCEA between groups. The mean correction was 12° in the mild, 15° in the moderate (p = 0.135), and 23° in the severe group (p < 0.001). Failure-free survival at five years was 100% for mild, 79% for moderate, and 92% for severely dysplastic hips (p = 0.225). Conclusion. Although requiring less correction than hips with moderate or severe dysplasia, we found PAO for mild dysplasia to be associated with promising PROMs, consistent with that of the general United States population, and excellent survivorship at five years. Future studies should compare these results with the outcome after arthroscopy of the hip in patients with mild dysplasia. Cite this article: Bone Joint J 2019;101-B(6 Supple B):16–22


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims. A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement. Patients and Methods. The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index. Results. The FEAR index showed excellent intraobserver and interobserver reliability on both MRI and radiographs. The FEAR index was more reliable on radiographs than on MRI. The FEAR index on MRI was lower in the stable borderline group (mean -4.2° (. sd. 9.1°)) compared with the unstable borderline group (mean 7.9° (. sd. 6.8°)). With a FEAR index cut-off value of 2°, 90% of patients were correctly identified as stable or unstable using the radiological FEAR index, compared with 82.5% using the FEAR index on MRI. The FEAR index was a better predictor of instability on plain radiographs than on MRI. Conclusion. The FEAR index measured on MRI is less reliable and less sensitive than the FEAR index measured on radiographs. The cut-off value of 2° for radiological FEAR index predicted hip stability with 90% probability. Cite this article: Bone Joint J 2019;101-B:1578–1584


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims. The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). Patients and Methods. A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (. sd. 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared. Results. The system reported accurate values for reconstruction of the hip when compared to those measured postoperatively using CT. The mean deviation from the executed overall hip length and offset were 1.6 mm (. sd. 2.9) and 0.5 mm (. sd. 3.0), respectively. Mean combined anteversion was similar and correlated between intraoperative measurements and postoperative CT measurements (32.5°, . sd. 5.9° versus 32.2°, . sd. 6.4°; respectively; R. 2. = 0.65; p < 0.001). There was a significant correlation between mean intraoperative (40.4°, . sd. 2.1°) acetabular component inclination and mean measured postoperative inclination (40.12°, . sd. 3.0°, R. 2. = 0.62; p < 0.001). There was a significant correlation between mean intraoperative version (23.2°, . sd. 2.3°), and postoperatively measured version (23.0°, . sd. 2.4°; R. 2. = 0.76; p < 0.001). Preoperative and postoperative femoral component anteversion were significantly correlated with one another (R. 2. = 0.64; p < 0.001). Three patients had CT scan measurements that differed substantially from the intraoperative robotic measurements when evaluating stem anteversion. Conclusion. This is the first study to evaluate the success of hip reconstruction overall using robotic-assisted THA. The overall hip reconstruction obtained in the operating theatre using robotic assistance accurately correlated with the postoperative component position assessed independently using CT based 3D modelling. Clinical correlation during surgery should continue to be practiced and compared with observed intraoperative robotic values. Cite this article: Bone Joint J 2018;100-B:1303–9


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 540 - 546
1 May 2019
Juneau D Grammatopoulos G Alzahrani A Thornhill R Inacio JR Dick A Vogel KI Dobransky J Beaulé PE Dwivedi G

Aims. Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. Patients and Methods. In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. Results. None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m. 2. vs 67 ml/m. 2. , p = 0.045; right ventricular: 80 ml/m. 2. vs 71 ml/m. 2. , p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. Conclusion. Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. . Cite this article: Bone Joint J 2019;101-B:540–546


Bone & Joint Open
Vol. 2, Issue 2 | Pages 119 - 124
1 Feb 2021
Shah RF Gwilym SE Lamb S Williams M Ring D Jayakumar P

Aims. The increase in prescription opioid misuse and dependence is now a public health crisis in the UK. It is recognized as a whole-person problem that involves both the medical and the psychosocial needs of patients. Analyzing aspects of pathophysiology, emotional health, and social wellbeing associated with persistent opioid use after injury may inform safe and effective alleviation of pain while minimizing risk of misuse or dependence. Our objectives were to investigate patient factors associated with opioid use two to four weeks and six to nine months after an upper limb fracture. Methods. A total of 734 patients recovering from an isolated upper limb fracture were recruited in this study. Opioid prescription was documented retrospectively for the period preceding the injury, and prospectively at the two- to four-week post-injury visit and six- to nine-month post-injury visit. Bivariate and multivariate analysis sought factors associated with opioid prescription from demographics, injury-specific data, Patient Reported Outcome Measurement Instrumentation System (PROMIS), Depression computer adaptive test (CAT), PROMIS Anxiety CAT, PROMIS Instrumental Support CAT, the Pain Catastrophizing Scale (PCS), the Pain Self-efficacy Questionnaire (PSEQ-2), Tampa Scale for Kinesiophobia (TSK-11), and measures that investigate levels of social support. Results. A new prescription of opioids two to four weeks after injury was independently associated with less social support (odds ratio (OR) 0.26, p < 0.001), less instrumental support (OR 0.91, p < 0.001), and greater symptoms of anxiety (OR 1.1, p < 0.001). A new prescription of opioids six to nine months after injury was independently associated with less instrumental support (OR 0.9, p < 0.001) and greater symptoms of anxiety (OR 1.1, p < 0.001). Conclusion. This study demonstrates that potentially modifiable psychosocial factors are associated with increased acute and chronic opioid prescriptions following upper limb fracture. Surgeons prescribing opioids for upper limb fractures should be made aware of the screening and management of emotional and social health. Cite this article: Bone Jt Open 2021;2(2):119–124


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 98 - 104
1 Jan 2021
van Ooij B Sierevelt IN van der Vis HM Hoornenborg D Haverkamp D

Aims. For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. Methods. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. Results. RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. Conclusion. Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98–104


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 712 - 719
1 Jun 2018
Batailler C Weidner J Wyatt M Dalmay F Beck M

Aims. The primary aim of this study was to define and quantify three new measurements to indicate the position of the greater trochanter. Secondary aims were to define ‘functional antetorsion’ as it relates to abductor function in populations both with and without torsional abnormality. Patients and Methods. Three new measurements, functional antetorsion, posterior tilt, and posterior translation of the greater trochanter, were assessed from 61 CT scans of cadaveric femurs, and their reliability determined. These measurements and their relationships were also evaluated in three groups of patients: a control group (n = 22), a ‘high-antetorsion’ group (n = 22) and a ‘low-antetorsion’ group (n = 10). Results. In the cadaver group, the mean anatomical antetorsion was 14.7° (. sd. 8.5; 0 to 36.5) and the functional antetorsion 21.5° (. sd. 8.1; 3.6 to 44.3): the posterior tilt was 73.3° (. sd. 10.8; 46.9 to 88.7) and the posterior translation 0.59 (. sd. 0.2; 0.2 to 0.9). These measurements had excellent intra and interobserver agreement with a range from 0.93 to 0.99. When the anatomical antetorsion decreased, the greater trochanter was more tilted and translated posteriorly in relation to the axis of the femoral neck, and the difference between functional and anatomical antetorsion increased. The results the three patient groups were similar to those of the cadaver group. Conclusion. The position of the greater trochanter and functional antetorsion varied with anatomical antetorsion. In the surgical management of femoral retrotorsion, subtrochanteric osteotomy can result in an excessively posterior position of the greater trochanter and an increase in functional antetorsion. Cite this article: Bone Joint J 2018;100-B:712–19


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 405 - 410
1 Feb 2021
Leo DG Perry DC Abdullah B Jones H

Aims. The reduction in mobility due to hip diseases in children is likely to affect their physical activity (PA) levels. Physical inactivity negatively influences quality of life and health. Our aim was to objectively measure PA in children with hip disease, and correlate it with the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility Score. Methods. A total of 28 children (12 boys and 16 girls) with hip disease aged between 8and 17 years (mean 12 (SD 3)) were studied between December 2018 and July 2019. Children completed the PROMIS Paediatric Item Bank v. 2.0 – Mobility Short Form 8a and wore a hip accelerometer (ActiGraph) for seven consecutive days. Sedentary time (ST), light PA (LPA), moderate to vigorous PA (MVPA), and vigorous PA were calculated from the accelerometers' data. The PROMIS Mobility score was classified as normal, mild, and moderate functions, based on the PROMIS cut scores on the physical function metric. A one-way analysis of covariance (ANCOVA) was used to assess differences among mobility (normal; mild; moderate) and measured PA and relationships between these variables were assessed using bivariate Pearson correlations. Results. Children classified as normally functioning on the PROMIS had less ST (p = 0.002), higher MVPA, (p = 0.002) and VPA (p = 0.004) compared to those classified as mild or moderate function. A moderate correlation was evident between the overall PROMIS score and daily LPA (r = 0.462, n = 28; p = 0.013), moderate-to-vigorous PA (r = 0.689, n = 28; p = 0.013) and vigorous PA (VPA) (r = 0.535, n = 28; p = 0.013). No correlation was evident between the mean daily ST and overall PROMIS score (r = -0.282, n = 28; p = 0.146). Conclusion. PROMIS Pediatric Mobility tool correlates well with experimentally measured levels of physical activity in children with hip disease. We provide external validity for the use of this tool as a measure of physical activity in children. Cite this article: Bone Joint J 2021;103-B(2):405–410