Advertisement for orthosearch.org.uk
Results 201 - 220 of 3643
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1607 - 1611
1 Dec 2009
Stufkens SAS Knupp M Lampert C van Dijk CN Hintermann B

We have compared the results at a mean follow-up of 13 years (11 to 14) of two groups of supination-external rotation type-4 fractures of the ankle, in one of which there was a fracture of the medial malleolus and in the other the medial deltoid ligament had been partially or completely ruptured.

Of 66 patients treated operatively between 1993 and 1997, 36 were available for follow-up. Arthroscopy had been performed in all patients pre-operatively to assess the extent of the intra-articular lesions. The American Orthopaedic Foot and Ankle Society hind-foot score was used for clinical evaluation and showed a significant difference in both the total and the functional scores (p < 0.05), but not in those for pain or alignment, in favour of the group with a damaged deltoid ligament (p < 0.05). The only significant difference between the groups on the short-form 36 quality-of-life score was for bodily pain, again in favour of the group with a damaged deltoid ligament. There was no significant difference between the groups in the subjective visual analogue scores or in the modified Kannus radiological score.

Arthroscopically, there was a significant difference with an increased risk of loose bodies in the group with an intact deltoid ligament (p < 0.005), although there was no significant increased risk of deep cartilage lesions in the two groups.

At a mean follow-up of 13 years after operative treatment of a supination-external rotation type-4 ankle fracture patients with partial or complete rupture of the medial deltoid ligament tended to have a better result than those with a medial malleolar fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1567 - 1573
1 Dec 2006
Kovac S Trebse R Milosev I Pavlovcic V Pisot V

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean follow-up time for stable stems was 15.1 years (12.1 to 16.6).

Survival of the stem at 15 years was 75.4% (95% confidence interval (CI) 67.3 to 83.5) with aseptic failure (including radiological failure) as the end-point, irrespective of the nature of the head and the quality of the cement mantle. Survival of the stem at 15 years was 79.1% (95% CI 69.8 to 88.4) and 67.1% (95% CI 51.3 to 82.9) with the CoCr alloy and ceramic heads, respectively. The quality of the cement mantle was graded as a function of stem coverage: stems with complete tip coverage (type 1) had an 84.9% (95% CI 77.6 to 92.2) survival at 15 years, compared with those with a poor tip coverage (type 2) which had a survival of only 22.4% (95% CI 2.4 to 42.4). The poor quality of the cement mantle and the implantation of an alumina head substantially lowered the survival of the stem.

In our opinion, further use of the cemented titanium alloy straight-stem femoral components used in our series is undesirable.


Aims

To investigate the longevity of uncemented fixation of a femoral component in total hip arthroplasty (THA) in patients with Dorr type C proximal femoral morphology.

Patients and Methods

A total of 350 consecutive uncemented THA in 320 patients were performed between 1983 and 1987, by a single surgeon using the Taperloc femoral component. The 63 patients (68 hips) with Dorr type C proximal femoral morphology were the focus of this review. The mean age of the patients was 69 years (24 to 88) and mean follow-up was 16.6 years (ten to 29). Survival analysis included eight patients (eight hips) who died without undergoing revision surgery prior to obtaining ten years follow-up. All 55 surviving patients (60 hips) were available for clinical assessment and radiographic review. As a comparator group, the survival and implant fixation in the remaining 282 THAs (257 patients) with Dorr type A and B morphology were evaluated. The mean age of these patients was 52 years (20 to 82).


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages - 308
1 Mar 2003
COLE AA BURWELL RG PRATT RK WEBB JK


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 775 - 777
1 Jul 2001
Rushton N


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 14 - 18
1 Jan 2001
Nimon GA Dobson PJ Angel KR Lewis PL Stevenson TM

Of 111 primary ankle ligament arthroplasties (modified Evans procedure) performed between 1983 and 1994, we were able to identify 89 patients (94 ankles) for follow-up. All were under 50 years of age. Two had died and one refused to co-operate; 86 patients (91 ankles) were therefore reviewed, 25 by telephone and the remainder by clinical examination with all but three also undergoing radiological review.

Of the 91 ankles, 70 had no or very mild pain and 72 had no or rare episodes of instability and when considered together only 59 (65%) had no or mild pain and minimal instability. The results were supported by the Karlsson grading system. Clinical examination showed that 17 of the 66 ankles examined had increased inversion, while 21 had some limitation of inversion. Early degenerative changes were seen in 11 ankles, although only four had subtalar changes. These results show that this procedure does not give universally good clinical results. Patient satisfaction, however, was high with 97.7% being willing to undergo the same procedure if their other ankle became similarly affected.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 308 - 314
1 Mar 2012
Ito H Tanino H Yamanaka Y Nakamura T Takahashi D Minami A Matsuno T

We have previously described the mid- to long-term results of conventional simple varus intertrochanteric osteotomy for osteonecrosis of the femoral head, showing that 19 of the 26 hips had good or excellent results. We extended the follow-up to a mean of 18.1 years (10.5 to 26) including a total of 34 hips in 28 patients, with a mean age at surgery of 33 years (19 to 53). There were 18 men and ten women and 25 hips (74%) had a satisfactory result with a Harris hip score ≥ 80. In all, six hips needed total hip replacement (THR) or hemiarthroplasty. The collapse of the femoral head or narrowing of the joint space was found to have progressed in nine hips (26%). Leg shortening after osteotomy was a mean of 19 mm (8 to 36). With conversion to THR or hemiarthroplasty as the endpoint, the ten-year survival rate was 88.2% (95% confidence interval (CI) 82.7 to 93.7) and the 20-year survival rate was 79.7% (95% CI 72.1 to 87.3); four hips were converted at ten years and other two hips were converted at 20 years.

Shortening of the leg after osteotomy remains a concern; however, the conventional varus half-wedge osteotomy provides favourable long-term results in hips with less than two-thirds of the medial part of the femoral head affected by necrotic bone and with normal bone superolaterally.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 60 - 66
1 Jan 1999
Schramm M Pitto RP Rohm E Hohmann D

We have examined the effect of the Wagner spherical acetabular osteotomy on preserving the joint in 38 hips with a mean follow-up of 17 years. At the time of the initial operation, 55% of patients had clinical symptoms and 30 joints showed minimal or absent radiological signs of osteoarthritis. At follow-up, 54% of patients had a good functional result.

The osteotomy improved the mean centre-edge angle from −3° to +15°, the mean anterior centre-edge angle to 23° and the acetabular head index to 75%. The obliquity of the acetabular roof decreased from 28° to 16°. One patient improved, but 14 deteriorated with joint degeneration. Of these, one progressed because of postoperative deep-tissue infection and five due to undercorrection. One patient needed total joint replacement after 14 years. At 17 years after operation, Wagner osteotomy had prevented progression of secondary arthritis in 63% of cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 322 - 326
1 Mar 1997
Katz RP Callaghan JJ Sullivan PM Johnston RC

We performed 83 consecutive cemented revision total hip arthroplasties in 77 patients between 1977 and 1983 using improved cementing techniques. One patient (two hips) was lost to follow-up. The remaining 76 patients (81 hips) had an average age at revision of 63.7 years (23 to 89).

At the final follow-up 18 hips (22%) had had a reoperation, two (2.5%) for sepsis, three (4%) for dislocation and 13 (16%) for aseptic loosening. The incidence of rerevision for aseptic femoral loosening was 5.4% and for aseptic acetabular loosening 16%. These results confirm that cemented femoral revision is a durable option in revision hip surgery when improved cementing techniques are used, but that cemented acetabular revision is unsatisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 351 - 356
1 May 1995
Malkani A Settecerri J Sim F Chao E Wallrichs S

We reviewed retrospectively 50 consecutive total hip arthroplasties with proximal femoral replacement prostheses in 49 patients. All the patients had massive bone loss. There were 31 women and 18 men who had undergone a mean of 3.1 hip operations. At the last review, 15 patients had died and two had been lost to follow-up, so that 32 patients (33 hips) were available for assessment. The mean age of the patients at the time of the operation was 60.6 years. The mean length of clinical follow-up was 11.1 +/- 4 years, and mean radiographic follow-up was 7.6 +/- 3.2 years. The average preoperative Harris hip score was 46 +/- 13 points, which improved to 80 +/- 10 points after one year and to 76 +/- 16 points at the latest follow-up. The most frequent complication was dislocation, which occurred in 11 hips. Four femoral components and seven acetabular prostheses were revised because of aseptic loosening. With revision at the end point, survivorship after total hip arthroplasty with a proximal femoral replacement prosthesis was predicted to be 64% at 12 years. Although our preliminary results of hip salvage with a proximal femoral replacement prosthesis were encouraging, a longer follow-up has shown a higher rate of failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 803 - 806
1 Nov 1992
Kristensen O Nafei A Kjaersgaard-Andersen P Hvid I Jensen J

We have reviewed at an average period of ten years the results of 71 consecutive primary arthroplasties with the Insall-Burstein total condylar knee prosthesis in patients with rheumatoid arthritis. Their mean age at surgery was 52 years (24 to 72). At follow-up the overall results (Hospital for Special Surgery knee rating score) were excellent or good in 77%, fair in 11% and poor in 11%. There was residual pain in only 5% of patients with prostheses in situ; 58% could walk more than 500 m, and the median range of motion was 108 degrees. Eight knees had been revised. Five underwent arthrodesis because of deep infection and three needed revision arthroplasty for mechanical loosening. The crude survival rate of the arthroplasties was 89%. The presence of radiolucency around the tibial component correlated significantly with the severity of residual pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 901 - 903
1 Sep 1990
Gargan M Bannister G

We reviewed 43 patients who had sustained soft-tissue injuries of the neck after a mean 10.8 years. Of these, only 12% had recovered completely. Residual symptoms were intrusive in 28% and severe in 12%. Pain in the neck and lower back was the commonest complaint and older patients had a worse prognosis. After two years, symptoms did not alter with further passage of time.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 664 - 666
1 Aug 1989
Tulp N Winia W

We reviewed 61 elbow synovectomies in 50 patients with rheumatoid arthritis, with follow-up varying from 4 to 10 years (mean 6.5 years). The results were graded as satisfactory in 70%, with no significant difference in the results between joints which were radiologically good before operation and those which had been destroyed. Longer term results were analysed of 27 elbow synovectomies in 22 patients followed up for over six years. The results were satisfactory in 67% of the patients in both 1981 and in 1987, with no deterioration over this period.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 712 - 716
1 Nov 1988
Edgar M Mehta M

We reviewed 77 unfused and 91 fused patients with idiopathic scoliosis who first attended between 1949 and 1965. Both groups were re-examined at least 10 years after reaching skeletal maturity, with attention to progression of the Cobb angle, increased in vertebral rotation, back pain and psychosocial problems. We found that spinal fusion protects the scoliotic spine from further deterioration during adult life except for those with severe curves and marked rotation. Fusion also significantly reduced the incidence of severe pain and allowed patients to carry out heavy physical work, but did not confer complete immunity from backache. Surgery improved the appearance, but patients were not always completely satisfied with the cosmetic result.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 89 - 92
1 Jan 1987
Pettine K Morrey B

Sixty-eight patients with 71 osteochondral fractures of the talus were evaluated an average of 7.5 years after the onset of symptoms to determine which factors influenced the final result. It was found that the type of fracture was the most important; delay in treatment also affected the result adversely. A scheme of treatment for each type of fracture is proposed.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 537 - 540
1 Aug 1986
Leung P Lam S

Of 92 children reviewed three to five years after treatment for fractured neck of femur (Lam 1976), we have been able to reassess 41, both clinically and radiographically, at 13 to 23 years after injury. The earlier clinical results had been excellent, despite a high incidence of complications; but the new, later review shows an 83% incidence of radiographic abnormality while 24% of the patients have pain, a limp or leg shortening. We present a recommended policy for management of this rare but potentially serious childhood injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 260 - 265
1 Mar 1986
Angus P Cowell H

The results of triple arthrodesis performed in 80 feet and followed for an average of 13 years are reviewed. Although the majority of patients were very pleased, the results of objective assessment were less favourable. There was a high incidence of degenerative joint changes in the ankle and midfoot and also of pseudarthrosis, avascular necrosis of the talus and residual deformity. Pre-operative rigid equinovarus deformity produced the majority of the poor results. It is suggested that bony resection alone might not be the best means of correcting severe equinus.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 109 - 113
1 Jan 1984
Rymaszewski L Mackay I Amis A Miller J

The effects of synovectomy and excision of the radial head in 40 elbows affected by rheumatoid arthritis have been assessed. In contrast with many reports indicating minimal side-effects of this procedure, a common pattern of deterioration from what was often a satisfactory initial result has been demonstrated. A biomechanical theory of one of the factors responsible for failure has been put forward and the importance of conserving or replacing the radial head emphasised.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 37 - 42
1 Feb 1980
Weisl H

The results of 757 intertorchanteric osteotomies for osteoarthritis of the hip carried out between 1958 and 1970 were reviewed. After osteotomy the joint space in two thirds of the hips was increased and a similar proportion experienced relief of pain lasting at least five years. However, the effect of the osteotomy declined after some ten years; only a quarter of the hips had a lasting "good result" as defined in this investigation. The best results were obtained in active patients under 70 years of age with unilateral hip disease in which a fair range of movement had been preserved despite some shortening and where the radiographs showed loss of joint space with a break in Shenton's line. In this study a displaced osteotomy fixed with a spline emerged as the most successful surgical technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1366 - 1371
1 Oct 2012
Pijls BG Valstar ER Kaptein BL Nelissen RGHH

This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (sd 0.76) in the MB group and 0.66 mm (sd 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores.

For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (sd 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (sd 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.