Patient-reported outcome measures (PROMs) are often used to evaluate the outcome of treatment in patients with distal radial fractures. Which PROM to select is often based on assessment of measurement properties, such as validity and reliability. Measurement properties are assessed in clinimetric studies, and results are often reviewed without considering the methodological quality of these studies. Our aim was to systematically review the methodological quality of clinimetric studies that evaluated measurement properties of PROMs used in patients with distal radial fractures, and to make recommendations for the selection of PROMs based on the level of evidence of each individual measurement property. A systematic literature search was performed in PubMed, EMbase, CINAHL and PsycINFO databases to identify relevant clinimetric studies. Two reviewers independently assessed the methodological quality of the studies on measurement properties, using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Level of evidence (strong / moderate / limited / lacking) for each measurement property per PROM was determined by combining the methodological quality and the results of the different clinimetric studies.Objectives
Methods
Lateral epicondylitis, or ’tennis elbow’, is
a common condition that usually affects patients between 35 and
55 years of age. It is generally self-limiting, but in some patients
it may continue to cause persistent symptoms, which can be refractory
to treatment. This review discusses the mechanism of disease, symptoms
and signs, investigations, current management protocols and potential
new treatments. Cite this article:
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439). Comparison of the post-operative radiographs between
the two groups showed no significant differences in lateral intrascaphoid
angle (p = 0.657) and scaphoid length
(p = 0.670) and height (p = 0.193). The radiolunate angle was significantly
different
(p = 0.020) but the mean value in both groups was <
10°. Comparison
of the dorsiflexion and palmar flexion of movement of the wrist
and the mean Mayo wrist score at the final clinical visit in each
group showed no significant difference (p = 0.190, p = 0.587 and
p = 0.265, respectively). Cancellous bone graft and K-wire fixation
were effective in the treatment of stable and unstable scaphoid
nonunion. Cite this article:
The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been used. In the remaining six patients, however, all fascicles of the ulnar nerve were separated and electrodiagnosis was performed after stimulation with a commercially available electromyographic system. In these procedures, recording electrodes were placed in flexor carpi ulnaris and the first dorsal interosseous. A single fascicle in the flexor carpi ulnaris in which a high amplitude had been recorded was selected as a donor and transferred to the musculocutaneous nerve. In the two patients who had not undergone electrodiagnosis, the recovery of biceps proved insufficient for normal use. Conversely, in the six patients in whom quantitative electrodiagnosis was used, elbow flexion recovered to an M4 level. Quantitative intra-operative electrodiagnosis is an effective method of selecting a favourable donor fascicle during the Oberlin procedure. Moreover, fascicles showing a high-amplitude in reading flexor carpi ulnaris are donor nerves that can restore normal elbow flexion without intrinsic loss.
We have reviewed 20 women and three men aged 22 to 73 years, who had sustained a Mason type-IIb fracture of the neck of the radius 14 to 25 years earlier. There were 19 patients with displacement of the fractures of 2 mm to 4 mm, of whom 13 had been subjected to early mobilisation and six had been treated in plaster for one to four weeks. Of four patients with displacement of 4 mm to 8 mm, three had undergone excision and one an open reduction of the head of radius. A total of 21 patients had no subjective complaints at follow-up, but two had slight impairment and occasional elbow pain. The mean range of movement and strength of the elbow were not impaired. The elbows had a higher prevalence of degenerative changes than the opposite side, but no greater reduction of joint space. Mason type-IIb fractures have an excellent long-term outcome if operation is undertaken when the displacement of the fracture exceeds 4 mm.
The June 2015 Wrist &
Hand Roundup360 looks at: Collagenase and Dupuytren’s disease – a genuine alternative to surgery?; iPad PROMise?; Should we learn how to do endoscopic carpal tunnel release?; Two-week radiographs a relic of the past?; Bible? Aspirate or excise?; Patient expectations and trapeziometacarpal osteoarthritis; Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation
Our aim was to correlate the health status with objective and radiological outcomes in patients treated by open reduction and internal fixation for fractures of both bones of the forearm. We assessed 23 patients (24 fractures) subjectively, objectively and radiologically at a mean of 34 months (11 to 72). Subjective assessment used the disability of the arm, shoulder and hand (DASH) and musculoskeletal functional attachment (MFA) questionnaires. The range of movement of the forearm and wrist, grip and pinch strength were measured objectively and standardised radiographs were evaluated. In general, patients reported good overall function based on the DASH (mean 12; range 0 to 42) and MFA (mean 19; range 0 to 51) scores. However, pronation and grip and pinch strength were significantly decreased (p <
0.005). These deficiencies correlated with poorer subjective outcomes. Operative stabilisation of fractures of the radius and ulna led to a reliably acceptable functional outcome. However, despite these generally satisfactory results, the outcome scores worsened with reduction in the range of movement of the forearm and wrist.
Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.
A displaced fracture of the scaphoid is one in
which the fragments have moved from their anatomical position or there
is movement between them when stressed by physiological loads. Displacement
is seen in about 20% of fractures of the waist of the scaphoid,
as shown by translation, a gap, angulation or rotation. A CT scan
in the true longitudinal axis of the scaphoid demonstrates the shape
of the bone and displacement of the fracture more accurately than
do plain radiographs. Displaced fractures can be treated in a plaster
cast, accepting the risk of malunion and nonunion. Surgically the
displacement can be reduced, checked radiologically, arthroscopically
or visually, and stabilised with headless screws or wires. However,
rates of union and deformity are unknown. Mild malunion is well
tolerated, but the long-term outcome of a displaced fracture that
healed in malalignment has not been established. This paper summarises aspects of the assessment, treatment and
outcome of displaced fractures of the waist of the scaphoid.
In patients with a tumour affecting the distal
ulna it is difficult to preserve the function of the wrist following extensive
local resection. We report the outcome of 12 patients (nine female,
three male) who underwent excision of the distal ulna without local
soft-tissue reconstruction. In six patients, an aggressive benign
tumour was present and six had a malignant tumour. At a mean follow-up
of 64 months (15 to 132) the mean Musculoskeletal Tumour score was
64% (40% to 93%) and the mean DASH score was 35 (10 to 80). The
radiological appearances were satisfactory in most patients. Local
recurrence occurred in one patient with benign disease and two with
malignant disease. The functional outcome was thus satisfactory
at a mean follow-up in excess of five years, with a relatively low
rate of complications. The authors conclude that complex reconstructive
soft-tissue procedures may not be needed in these patients. Cite this article:
We performed a retrospective study to determine
the effect of osteoporosis on the functional outcome of osteoporotic
distal radial fractures treated with a volar locking plate. Between
2009 and 2012 a total of 90 postmenopausal women with an unstable
fracture of the distal radius treated with a volar locking plate
were studied. Changes in the radiological parameters of 51 patients
with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 ( We found that osteoporosis does not have a negative effect on
the functional outcome and additional analysis did not show a correlation
between T-score and outcome. Cite this article:
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.
In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant. Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.
Between 1995 and 2006, five intra-articular osteotomies of the head of the radius were performed in patients with symptomatic healed displaced articular fractures. Pre-operatively, all patients complained of persistent painful clicking on movement. Only patients with mild or no degenerative changes of the radial head and capitellum were considered for osteotomy. The operations were performed at a mean of 8.2 months (4 to 13) after injury and the patients were reviewed at a mean of 5.5 years (15 months to 12 years) after the osteotomy. The average Mayo Elbow Performance Index Score improved significantly from 74 before to 88 after operation, with four patients rated as good or excellent (p <
0.05). The subjective patient satisfaction score was 8.4 on a ten-point scale. All osteotomies healed and there were no complications. In this small series intra-articular osteotomy of the head of the radius was a safe and effective treatment for symptomatic intra-articular malunion without advanced degenerative changes.
We retrospectively evaluated the clinical and
radiological outcomes of a consecutive cohort of patients aged >
70 years with a displaced fracture of the olecranon, which was treated
non-operatively with early mobilisation. We identified 28 such patients
(27 women) with a mean age of 82 years (71 to 91). The elbow was
initially immobilised in an above elbow cast in 90° of flexion of
the elbow for a mean of five days. The cast was then replaced by
a sling. Active mobilisation was encouraged as tolerated. No formal
rehabilitation was undertaken. At a mean follow-up of 16 months
(12 to 26), the mean ranges of flexion and extension were 140° and
15° respectively. On a visual analogue scale of 1 (no pain) to 10,
the mean pain score was 1 (0 to 8). Of the original 28 patients
22 developed nonunion, but no patients required surgical treatment. We conclude that non-operative functional treatment of displaced
olecranon fractures in the elderly gives good results and a high
rate of satisfaction. Cite this article:
The October 2013 Spine Roundup360 looks at: Standing straighter may reduce falls; Operative management of congenital kyphosis; Athletic discectomy; Lumbar spine stenosis worsens with time; Flexible stabilisation?: spinal stenosis revisited; Do epidural steroids cause spinal fractures?; Who does well with cervical myelopathy?; Secretly adverse to BMP-2?
The October 2013 Wrist &
Hand Roundup360 looks at: Cost effectiveness of Dupuytren’s surgery; A 'new horizon' in distal radius imaging; Undisplaced means undisplaced; The mystery of the distal radial fracture continues; How thick is thick enough?: articular cartilage step off revisited; Is the midcarpal joint more important than we think?; Plates and Kirschner wires; Better early results with an IM nail?
Down’s syndrome is associated with a number of
musculoskeletal abnormalities, some of which predispose patients
to early symptomatic arthritis of the hip. The purpose of the present
study was to review the general and hip-specific factors potentially
compromising total hip replacement (THR) in patients with Down’s
syndrome, as well as to summarise both the surgical techniques that
may anticipate the potential adverse impact of these factors and
the clinical results reported to date. A search of the literature
was performed, and the findings further informed by the authors’
clinical experience, as well as that of the hip replacement in Down
Syndrome study group. The general factors identified include a high
incidence of ligamentous laxity, as well as associated muscle hypotonia
and gait abnormalities. Hip-specific factors include: a high incidence
of hip dysplasia, as well as a number of other acetabular, femoral
and combined femoroacetabular anatomical variations. Four studies
encompassing 42 hips, which reported the clinical outcomes of THR
in patients with Down’s syndrome, were identified. All patients
were successfully treated with standard acetabular and femoral components.
The use of supplementary acetabular screw fixation to enhance component
stability was frequently reported. The use of constrained liners
to treat intra-operative instability occurred in eight hips. Survival
rates of between 81% and 100% at a mean follow-up of 105 months
(6 to 292) are encouraging. Overall, while THR in patients with
Down’s syndrome does present some unique challenges, the overall
clinical results are good, providing these patients with reliable
pain relief and good function. Cite this article: