The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively. A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.Aims
Methods
1. The history of the genesis of the Putti-Platt operation for habitual dislocation of the shoulder is outlined so far as it is known. 2. The operation is described and briefly commented upon. 3. Since there is both gleno-labrial detachment and defect in the humeral head successful treatment depends upon: i) a block to the exit of the humeral head in front and ii) limitation of
Eight children with paralytic drop foot after intramuscular injections later developed gluteal fibrosis. Sciatic palsy, presenting as equinovarus or equinus deformity, was diagnosed on average 3.8 months after the intragluteal injections, but gluteal fibrosis was not diagnosed until 5.1 years after the injections. In three patients the equinovarus recurred after surgical correction due to persistent muscle imbalance and the effect of the
Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.Aims
Methods
We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and
We treated 98 consecutive patients with Perthes’ disease by a unilateral brace in
Thirty-three patients with impingement syndrome of the rotator cuff were studied before and at operation. It was shown that the rotator cuff lengthens and twists during elevation of the arm. Elevation is achieved by early glenohumeral abduction and continuous flexion and
We reviewed 19 children who had undergone a new modification of the L'Episcopo procedure for obstetric brachial plexus palsy. Through an axillary approach the latissimus dorsi tendon was re-routed anteriorly to the humerus and then anastomosed to the teres major tendon routed posteriorly. At an average follow-up of four years two months, the mean increase in shoulder abduction was 26 degrees and the mean increase in
Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck. A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed.Aims
Methods
We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of
We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the
The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR). This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.Aims
Methods
It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance.Aims
Methods
Nearly 99,000 total knee arthroplasties (TKAs) are performed in UK annually. Despite plenty of research, the satisfaction rate of this surgery is around 80%. One of the important intraoperative factors affecting the outcome is alignment. The relationship between joint obliquity and functional outcomes is not well understood. Therefore, a study is required to investigate and compare the effects of two types of alignment (mechanical and kinematic) on functional outcomes and range of motion. The aim of the study is to compare navigated kinematically aligned TKAs (KA TKAs) with navigated mechanically aligned TKA (MA TKA) in terms of function and ROM. We aim to recruit a total of 96 patients in the trial. The patients will be recruited from clinics of various consultants working in the trust after screening them for eligibility criteria and obtaining their informed consent to participate in this study. Randomization will be done prior to surgery by a software. The primary outcome measure will be the Knee injury and Osteoarthritis Outcome Score The secondary outcome measures include Oxford Knee Score, ROM, EuroQol five-dimension questionnaire, EuroQol visual analogue scale, 12-Item Short-Form Health Survey (SF-12), and Forgotten Joint Score. The scores will be calculated preoperatively and then at six weeks, six months, and one year after surgery. The scores will undergo a statistical analysis.Aims
Methods
We report the 20-year results of Bonnin's modification of the Bristow-Latarjet procedure in 14 patients operated on by one surgeon. All but one patient had had traumatic dislocations. At review, the Rowe scores were excellent in five, good in eight and fair in one. The functional outcome was satisfactory, with a mean Constant-Murley score of 80 points (68 to 95), but 12 patients had restriction of
Posterolateral instability of the knee is difficult to diagnose and treat. It has been attributed to failure of ligament reconstruction and has been the cause of numerous knee operations. We present a small group of patients who complained of giving way of the knee and who had an increased range of
We studied 54 patients operated on for combined supraspinatus and infraspinatus rotator-cuff tears. The presence or absence of the dropping and hornblower’s clinical signs of impaired
Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.Aims
Methods
We examined ten femoral veins with duplex ultrasound during total hip replacement to demonstrate the operative manoeuvres which cause venous obstruction and to assess prophylactic measures which may overcome it. Exposure of the acetabulum by distraction of the femur with a hook was less likely to occlude flow than retraction with bone levers. Adequate exposure of the femoral shaft by adduction, flexion and either internal or
We reviewed eight children (ten shoulders) who had suffered neonatal sepsis, after a mean follow-up of 14 years (11 to 15). The delay between the onset of symptoms and diagnosis was one day in five patients, two days in three and seven days in one. All ten shoulders were treated by aspiration, followed by arthrotomy in two. At follow-up, five of the ten shoulders had a full range of movement and the others had minimal restriction of