Advertisement for orthosearch.org.uk
Results 201 - 220 of 696
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 958 - 963
3 May 2021
Nguyen NTV Martinez-Catalan N Songy CE Sanchez-Sotelo J

Aims

The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively.

Methods

A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 19 - 25
1 Feb 1948
Osmond-Clarke H

1. The history of the genesis of the Putti-Platt operation for habitual dislocation of the shoulder is outlined so far as it is known. 2. The operation is described and briefly commented upon. 3. Since there is both gleno-labrial detachment and defect in the humeral head successful treatment depends upon: i) a block to the exit of the humeral head in front and ii) limitation of external rotation movement


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 83 - 85
1 Jan 1993
Napiontek M Ruszkowski K

Eight children with paralytic drop foot after intramuscular injections later developed gluteal fibrosis. Sciatic palsy, presenting as equinovarus or equinus deformity, was diagnosed on average 3.8 months after the intragluteal injections, but gluteal fibrosis was not diagnosed until 5.1 years after the injections. In three patients the equinovarus recurred after surgical correction due to persistent muscle imbalance and the effect of the external rotation contracture of the hip


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims

Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes.

Methods

In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 290 - 292
1 Mar 1994
Vanek J

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 979 - 982
1 Nov 1997
Futami T Suzuki S

We treated 98 consecutive patients with Perthes’ disease by a unilateral brace in external rotation, flexion and abduction and a further consecutive 110 by a bilateral cast with the hips in internal rotation and abduction. During treatment in the unilateral brace, six (6.1%) hips on the opposite side developed evidence of Perthes’ disease and one developed this after the brace had been removed. In children managed in bilateral casts, no contralateral Perthes’ disease was seen. Adequate containment of the femoral head may prevent subsequent changes in the opposite hip


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 361 - 366
1 May 1989
Watson M

Thirty-three patients with impingement syndrome of the rotator cuff were studied before and at operation. It was shown that the rotator cuff lengthens and twists during elevation of the arm. Elevation is achieved by early glenohumeral abduction and continuous flexion and external rotation. The range of free rotation at the glenohumeral joint diminishes progressively during elevation. Rotator cuff impingement occurs towards the end of the early glenohumeral abduction. Excision arthroplasty of the acromioclavicular joint and anterior acromioplasty is highly effective for impingement under the acromion, but only moderately effective where impingement is under the acromioclavicular joint


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 897 - 901
1 Nov 1992
Covey D Riordan D Milstead M Albright J

We reviewed 19 children who had undergone a new modification of the L'Episcopo procedure for obstetric brachial plexus palsy. Through an axillary approach the latissimus dorsi tendon was re-routed anteriorly to the humerus and then anastomosed to the teres major tendon routed posteriorly. At an average follow-up of four years two months, the mean increase in shoulder abduction was 26 degrees and the mean increase in external rotation was 29 degrees. No neurovascular injury or postoperative infection occurred. Two patients had complications, and five did not gain from the procedure. The modified operation was relatively easier to perform and provided excellent cosmesis


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims

Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck.

Methods

A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 388 - 395
1 Apr 2004
Sirveaux F Favard L Oudet D Huquet D Walch G Mole D

We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 718 - 724
1 Apr 2021
Cavalier M Johnston TR Tran L Gauci M Boileau P

Aims

The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR).

Methods

This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 974 - 980
25 Nov 2021
Allom RJ Wood JA Chen DB MacDessi SJ

Aims

It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance.

Methods

A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance.


Aims

Nearly 99,000 total knee arthroplasties (TKAs) are performed in UK annually. Despite plenty of research, the satisfaction rate of this surgery is around 80%. One of the important intraoperative factors affecting the outcome is alignment. The relationship between joint obliquity and functional outcomes is not well understood. Therefore, a study is required to investigate and compare the effects of two types of alignment (mechanical and kinematic) on functional outcomes and range of motion.

Methods

The aim of the study is to compare navigated kinematically aligned TKAs (KA TKAs) with navigated mechanically aligned TKA (MA TKA) in terms of function and ROM. We aim to recruit a total of 96 patients in the trial. The patients will be recruited from clinics of various consultants working in the trust after screening them for eligibility criteria and obtaining their informed consent to participate in this study. Randomization will be done prior to surgery by a software. The primary outcome measure will be the Knee injury and Osteoarthritis Outcome Score The secondary outcome measures include Oxford Knee Score, ROM, EuroQol five-dimension questionnaire, EuroQol visual analogue scale, 12-Item Short-Form Health Survey (SF-12), and Forgotten Joint Score. The scores will be calculated preoperatively and then at six weeks, six months, and one year after surgery. The scores will undergo a statistical analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 73 - 76
1 Jan 1995
Singer G Kirkland P Emery R

We report the 20-year results of Bonnin's modification of the Bristow-Latarjet procedure in 14 patients operated on by one surgeon. All but one patient had had traumatic dislocations. At review, the Rowe scores were excellent in five, good in eight and fair in one. The functional outcome was satisfactory, with a mean Constant-Murley score of 80 points (68 to 95), but 12 patients had restriction of external rotation (86%). There were radiological degenerative changes in ten shoulders (71%): six in Samilson grade I, one in grade II, and three in grade III. Isometric power was considerably reduced in patients with grade-III degenerative change. This operation provides good long-term shoulder stability, but the high incidence of radiological degenerative change is a cause for concern


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 187 - 192
1 Mar 1994
Ferrari D Ferrari J Coumas J

Posterolateral instability of the knee is difficult to diagnose and treat. It has been attributed to failure of ligament reconstruction and has been the cause of numerous knee operations. We present a small group of patients who complained of giving way of the knee and who had an increased range of external rotation of the tibia at 90 degrees knee flexion. The patients all had similar symptoms. We describe the standing apprehension test, which was positive in every case. Anterior subluxation of the lateral femoral condyle was detected manually in four patients and confirmed by radiography and MRI in one. The medial knee pain which is often associated with episodes of instability is probably due to stretching of the posteromedial soft tissues and perhaps the saphenous nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 624 - 628
1 Jul 1998
Walch G Boulahia A Calderone S Robinson AHN

We studied 54 patients operated on for combined supraspinatus and infraspinatus rotator-cuff tears. The presence or absence of the dropping and hornblower’s clinical signs of impaired external rotation were correlated with Goutallier stage-3 or stage-4 fatty degeneration of infraspinatus and teres minor. These grades of fatty degeneration have previously been correlated with a poorer outcome from reconstructive surgery. We found that hornblower’s sign had 100% sensitivity and 93% specificity for irreparable degeneration of teres minor and the dropping sign 100% sensitivity and 100% specificity for similar degeneration of infraspinatus. In seven patients, teres minor showed hypertrophy. This muscle can give useful function for the activities of daily living in patients with rotator-cuff tears in whom it is intact


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 74 - 80
1 Jun 2021
Deckey DG Rosenow CS Verhey JT Brinkman JC Mayfield CK Clarke HD Bingham JS

Aims

Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA.

Methods

A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 918 - 921
1 Nov 1994
Warwick D Martin A Glew D Bannister G

We examined ten femoral veins with duplex ultrasound during total hip replacement to demonstrate the operative manoeuvres which cause venous obstruction and to assess prophylactic measures which may overcome it. Exposure of the acetabulum by distraction of the femur with a hook was less likely to occlude flow than retraction with bone levers. Adequate exposure of the femoral shaft by adduction, flexion and either internal or external rotation caused cessation of flow in all cases. In four cases an A-V Impulse System foot pump was activated during periods of stasis. In each case it overcame the obstruction and produced peak velocities which were twice that of the resting state. In five cases, towards the end of the procedure, debris was seen travelling proximally through the femoral vein


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 645 - 650
1 Jul 1998
Bos CFA Mol LJCD Obermann WR Tjin a Ton ER

We reviewed eight children (ten shoulders) who had suffered neonatal sepsis, after a mean follow-up of 14 years (11 to 15). The delay between the onset of symptoms and diagnosis was one day in five patients, two days in three and seven days in one. All ten shoulders were treated by aspiration, followed by arthrotomy in two. At follow-up, five of the ten shoulders had a full range of movement and the others had minimal restriction of external rotation. Shortening of 10 cm was present in one patient, while two with bilateral involvement had disproportionally short humeri. Early diagnosis and treatment favour the outcome in septic arthritis of the shoulder. With late diagnosis, deformation of the humeral head and shortening of the humerus cause marked cosmetic abnormality but negligible functional loss