Advertisement for orthosearch.org.uk
Results 2081 - 2100 of 2553
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 632 - 635
1 May 2009
Adams JE Hoskin TL Morrey BF Steinmann SP

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation.

At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1344 - 1350
1 Oct 2010
Carrothers AD Gilbert RE Jaiswal A Richardson JB

Despite the increasing interest and subsequent published literature on hip resurfacing arthroplasty, little is known about the prevalence of its complications and in particular the less common modes of failure. The aim of this study was to identify the prevalence of failure of hip resurfacing arthroplasty and to analyse the reasons for it.

From a multi-surgeon series (141 surgeons) of 5000 Birmingham hip resurfacings we have analysed the modes, prevalence, gender differences and times to failure of any hip requiring revision. To date 182 hips have been revised (3.6%). The most common cause for revision was a fracture of the neck of the femur (54 hips, prevalence 1.1%), followed by loosening of the acetabular component (32 hips, 0.6%), collapse of the femoral head/avascular necrosis (30 hips, 0.6%), loosening of the femoral component (19 hips, 0.4%), infection (17 hips, 0.3%), pain with aseptic lymphocytic vascular and associated lesions (ALVAL)/metallosis (15 hips, 0.3%), loosening of both components (five hips, 0.1%), dislocation (five hips, 0.1%) and malposition of the acetabular component (three hips, 0.1%). In two cases the cause of failure was unknown.

Comparing men with women, we found the prevalence of revision to be significantly higher in women (women = 5.7%; men = 2.6%, p < 0.001). When analysing the individual modes of failure women had significantly more revisions for loosening of the acetabular component, dislocation, infection and pain/ALVAL/metallosis (p < 0.001, p = 0.004, p = 0.008, p = 0.01 respectively).

The mean time to failure was 2.9 years (0.003 to 11.0) for all causes, with revision for fracture of the neck of the femur occurring earlier than other causes (mean 1.5 years, 0.02 to 11.0). There was a significantly shorter time to failure in men (mean 2.1 years, 0.4 to 8.7) compared with women (mean 3.6 years, 0.003 to 11.0) (p < 0.001).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1592 - 1596
1 Dec 2011
Babis GC Sakellariou VI Chatziantoniou AN Soucacos PN Megas P

We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting.

At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision.

We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1660 - 1664
1 Dec 2011
Judge A Arden NK Price A Glyn-Jones S Beard D Carr AJ Dawson J Fitzpatrick R Field RE

We obtained pre-operative and six-month post-operative Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent total hip replacement and 1784 patients who underwent total knee replacement. They all also completed a six-month satisfaction question.

Scatter plots showed no relationship between pre-operative Oxford scores and six-month satisfaction scores. Spearman’s rank correlation coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01) between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between OKS and satisfaction. A receiver operating characteristic (ROC) curve analysis was used to identify a cut-off point for the pre-operative OHS/OKS that identifies whether or not a patient is satisfied with surgery. We obtained an area under the ROC curve of 0.51 (95% CI 0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60) for knee replacement, indicating that pre-operative Oxford scores have no predictive accuracy in distinguishing satisfied from dissatisfied patients.

In the NHS widespread attempts are being made to use patient-reported outcome measures (PROMs) data for the purpose of prioritising patients for surgery. Oxford hip and knee scores have no predictive accuracy in relation to post-operative patient satisfaction. This evidence does not support their current use in prioritising access to care.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 545 - 549
1 Apr 2010
Li W Chi Y Xu H Wang X Lin Y Huang Q Mao F

We reviewed the outcome of a retrospective case series of eight patients with atlantoaxial instability who had been treated by percutaneous anterior transarticular screw fixation and grafting under image-intensifier guidance between December 2005 and June 2008.

The mean follow-up was 19 months (8 to 27). All eight patients had a solid C1–2 fusion. There were no breakages or displacement of screws. All the patients with pre-operative neck pain had immediate relief from their symptoms or considerable improvement. There were no major complications. Our preliminary clinical results suggest that percutaneous anterior transarticulation screw fixation is technically feasible, safe, useful and minimally invasive when using the appropriate instruments allied to intra-operative image intensification, and by selecting the correct puncture point, angle and depth of insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1493 - 1496
1 Nov 2011
Lee JK Choi CH

Bone defects are occasionally encountered during primary total knee replacement (TKR) and cause difficulty in establishing a stable well-aligned bone-implant interface. Between March 1999 and November 2005, 59 knees in 43 patients underwent primary TKR with a metal block augmentation for tibial bone deficiency. In all, six patients (eight knees) died less than four years post-operatively, and four patients (five knees) were lost to follow-up leaving 46 knees in 33 patients available for review at a mean of 78.6 months (62 to 129). The clinical results obtained, including range of movement, American Knee Society and Oxford knee scores, and the Western Ontario and McMaster Universities osteoarthritis index, were good to excellent, with no failures. Radiolucent lines at the block-cement-bone interface were noted in five knees (11%) during the first post-operative year, but these did not progress.

Modular rectangular metal augmentation for tibial bone deficiency is a useful option. No deterioration of the block-prosthesis or block-cement-bone interface was seen at minimum of five years follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1665 - 1669
1 Dec 2011
Gaston CL Bhumbra R Watanuki M Abudu AT Carter SR Jeys LM Tillman RM Grimer RJ

We retrospectively compared the outcome after the treatment of giant cell tumours of bone either with curettage alone or with adjuvant cementation. Between 1975 and 2008, 330 patients with a giant cell tumour were treated primarily by intralesional curettage, with 84 (25%) receiving adjuvant bone cement in the cavity. The local recurrence rate for curettage alone was 29.7% (73 of 246) compared with 14.3% (12 of 84) for curettage and cementation (p = 0.001). On multivariate analysis both the stage of disease and use of cement were independent significant factors associated with local recurrence. The use of cement was associated with a higher risk of the subsequent need for joint replacement. In patients without local recurrence, 18.1% (13 of 72) of those with cement needed a subsequent joint replacement compared to 2.3% (4 of 173) of those without cement (p = 0.001). In patients who developed local recurrence, 75.0% (9 of 12) of those with previous cementation required a joint replacement, compared with 45.2% (33 of 73) of those without cement (p = 0.044).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 856 - 861
1 Jun 2010
Emms NW Stockley I Hamer AJ Wilkinson JM

Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis.

At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate.

There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1627 - 1630
1 Dec 2008
Shiha AE Khalifa ARH Assaghir YM Kenawey MO

We present two children with massive defects of the tibia and an associated active infection who were treated by medial transport of the fibula using the Ilizarov device. The first child had chronic discharging osteomyelitis which affected the whole tibial shaft. The second had sustained bilateral grade-IIIB open tibial fractures in a motor-car accident. The first child was followed up for three years and the second for two years. Both achieved solid union between the proximal and distal stumps of the tibia and the fibula, with hypertrophy of the fibula. The first child had a normal range of movement at the knee, ankle and foot but there was shortening of 1.5 cm. The second had persistent anterior angulation at the proximal tibiofibular junction and the ankle was stiff in equinus.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1037 - 1043
1 Aug 2009
Krieg AH Speth BM Ochsner PE

Polyethylene wear of acetabular components is a key factor in the development of periprosthetic osteolysis and wear at the articular surface has been well documented and quantified, but fewer data are available about changes which occur at the backside of the liner.

At revision surgery for loosening of the femoral component we retrieved 35 conventional modular acetabular liners of the same design. Linear and volumetric articular wear, backside volumetric change and the volume of the screw-head indentations were quantified. These volumes, clinical data and the results from radiological Ein Bild Röntgen Analyse migration analysis were used to identify potential factors influencing the volumetric articular wear and backside volumetric change.

The rate of backside volumetric change was found to be 2.8% of the rate of volumetric articular wear and decreased with increasing liner size. Migrated acetabular components showed significantly higher rates of backside volumetric change plus screw-head indentations than those without migration.

The backside volumetric change was at least ten times larger than finite-element simulation had suggested. In a stable acetabular component with well-anchored screws, the amount of backside wear should not cause clinical problems. Impingement of the screw-heads could produce more wear particles than those generated at the liner-shell interface. Because the rate of backside volumetric change is only 2.8% of the rate of volumetric articular wear and since creep is likely to contribute a significant portion to this, the debris generated by wear at the backside of the liner may not be sufficient to create a strong osteolytic response.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 750 - 756
1 Jun 2009
Mannan K Scott G

We describe the survivorship of the Medial Rotation total knee replacement (TKR) at ten years in 228 cemented primary replacements implanted between October 1994 and October 2006, with their clinical and radiological outcome. This implant has a highly congruent medial compartment, with the femoral component represented by a portion of a sphere which articulates with a matched concave surface on the medial side of the tibial insert.

There were 78 men (17 bilateral TKRs) and 111 women (22 bilateral TKRs) with a mean age of 67.9 years (28 to 90). All the patients were assessed clinically and radiologically using the American Knee Society scoring systems. The mean follow-up was for six years (1 to 13) with only two patients lost to follow-up and 34 dying during the period of study, one of whom had required revision for infection.

There were 11 revisions performed in total, three for aseptic loosening, six for infection, one for a periprosthetic fracture and one for a painful but well-fixed replacement performed at another centre.

With revision for any cause as the endpoint, the survival at ten years was 94.5% (95% CI 85.1 to 100), and with aseptic loosening as the endpoint 98.4% (95% CI 93 to 100). The mean American Knee Society score improved from 47.6 (0 to 88) to 72.2 (26 to 100) and for function from 45.1 (0 to 100) to 93.1 (45 to 100). Radiological review failed to detect migration in any of the surviving knees.

The clinical and radiological results of the Medial Rotation TKR are satisfactory at ten years. The increased congruence of the medial compartment has not led to an increased rate of loosening and continued use can be supported.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model.

A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads.

All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (sd 1500), 28 800 cycles (sd 6300), and 26 400 cycles (sd 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (sd 10 700), 36 000 cycles (sd 7200), and 36 600 cycles (sd 10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution.

In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 817 - 822
1 Jun 2010
Beekman PDA Katusic D Berghs BM Karelse A De Wilde L

We retrospectively reviewed 11 consecutive patients with an infected reverse shoulder prosthesis. Patients were assessed clinically and radiologically, and standard laboratory tests were carried out. Peroperative samples showed Propionbacterium acnes in seven, coagulase-negative Staphylococcus in five, methicillin-resistant staphylococcus aureus in one and Escherichia coli in one. Two multibacterial and nine monobacterial infections were seen. Post-operatively, patients were treated with intravenous cefazolin for at least three days and in all antibiotic therapy was given for at least three months. Severe pain (3 of 11) or severe limitation of function (3 of 11) are not necessarily seen. A fistula was present in eight, but function was not affected. All but one patient were considered free of infection after one-stage revision at a median follow-up of 24 months, and without antibiotic treatment for a minimum of six months. One patient had a persistent infection despite a second staged revision, but is now free of infection with a spacer. Complications included posterior dislocation in one, haematoma in one and a clavicular fracture in one. At the most recent follow-up the median post-operative Constant-Murley score was 55, 6% adjusted for age, gender and dominance.

A one-stage revision arthroplasty reduces the cost and duration of treatment. It is reliable in eradicating infection and good functional outcomes can be achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1165 - 1171
1 Sep 2007
Gohil S Annear PO Breidahl W

Animal studies have shown that implanted anterior cruciate ligament (ACL) grafts initially undergo a process of revascularisation prior to remodelling, ultimately increasing mechanical strength. We investigated whether minimal debridement of the intercondylar notch and the residual stump of the ruptured ACL leads to earlier revascularisation in ACL reconstruction in humans. We undertook a randomised controlled clinical trial in which 49 patients underwent ACL reconstruction using autologous four-strand hamstring tendon grafts. Randomised by the use of sealed envelopes, 25 patients had a conventional clearance of the intercondylar notch and 24 had a minimal debridement method. Three patients were excluded from the study. All patients underwent MR scanning postoperatively at 2, 6 and 12 months, together with clinical assessment using a KT-1000 arthrometer and International Knee Documentation Committee (IKDC) evaluation. All observations were made by investigators blinded to the surgical technique. Signal intensity was measured in 4 mm diameter regions of interest along the ACL graft and the mid-substance of the posterior cruciate ligament.

Our results indicate that minimal debridement leads to earlier revascularisation within the mid-substance of the ACL graft at two months (paired t-test, p = 0.002). There was a significant reduction of mid-substance signal six months after the minimal debridement technique (paired t-test, p = 0.00007). No statistically significant differences were found in tunnel placement, incidence of Cyclops lesions, blood loss, IKDC scores, range of movement or Lachman test between the two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1029 - 1037
1 Aug 2005
Mayer HM


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 91 - 96
1 Jan 2009
Labbe J Peres O Leclair O Goulon R Scemama P Jourdel F

We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 234 - 239
1 Feb 2009
Puri A Subin BS Agarwal MG

We evaluated the results of fibular centralisation as a stand alone technique to reconstruct defects that occurred after resection of tumours involving the tibial diaphysis and distal metaphysis.

Between January 2003 and December 2006, 15 patients underwent excision of tumours of the tibial diaphysis or distal metaphysis and reconstruction by fibular centralisation. Their mean age was 17 years (7 to 40). Two patients were excluded; one died from the complications of chemotherapy and a second needed a below-knee amputation for a recurrent giant-cell tumour. A total of 13 patients were reviewed after a mean follow-up of 29 months (16 to 48). Only 16 of 26 host graft junctions united primarily. Ten junctions in ten patients needed one or more further procedure before union was achieved. At final follow-up 12 of the 13 patients had fully united grafts; 11 walked without aids. The mean time to union at the junctions that united was 12 months (3 to 36). The mean Musculoskeletal Tumor Society Score was 24.7 (16 to 30).

Fibular centralisation is a durable reconstruction for defects of the tibial diaphysis and distal metaphysis with an acceptable functional outcome. Stable osteosynthesis is the key to successful union. Additional bone grafting is recommended for patients who need postoperative radiotherapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1084 - 1087
1 Aug 2011
Tauchi R Imagama S Kanemura T Yoshihara H Sato K Deguchi M Kamiya M Ishiguro N

We reviewed seven children with torticollis due to refractory atlanto-axial rotatory fixation who were treated in a halo vest. Pre-operative three-dimensional CT and sagittal CT imaging showed deformity of the superior articular process of C2 in all patients. The mean duration of halo vest treatment was 67 days (46 to 91). The mean follow-up was 34 months (8 to 73); at the latest review six patients demonstrated remodelling of the deformed articular process. The other child, who had a more severe deformity, required C1-2 fusion.

We suggest that patients with atlanto-axial rotatory fixation who do not respond to conservative treatment and who have deformity of the superior articular process of C2 should undergo manipulative reduction and halo-vest fixation for two to three months to induce remodelling of the deformed superior articular process before C1-2 fusion is considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1256 - 1259
1 Sep 2008
Kedgley AE DeLude JA Drosdowech DS Johnson JA Bicknell RT

This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive abduction after hemiarthroplasty of the shoulder for the treatment of fractures. We used seven pairs of fresh-frozen cadaver shoulders to create simulated four-part fractures of the proximal humerus, which were then reconstructed with hemiarthroplasty and reattachment of the tuberosities. The specimens were randomised, so that one from each pair was repaired using the computer-assisted technique, whereas a traditional hemiarthroplasty without navigation was performed in the contralateral shoulder. Kinematic data were obtained using an electromagnetic tracking device.

The traditional technique resulted in posterior and inferior translation of the humeral head. No statistical differences were observed before or after computer-assisted surgery.

Although it requires further improvement, the computer-assisted approach appears to allow glenohumeral kinematics to more closely replicate those of the native joint, potentially improving the function of the shoulder and extending the longevity of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 751 - 759
1 Jun 2010
Tsirikos AI Garrido EG

A review of the current literature shows that there is a lack of consensus regarding the treatment of spondylolysis and spondylolisthesis in children and adolescents. Most of the views and recommendations provided in various reports are weakly supported by evidence. There is a limited amount of information about the natural history of the condition, making it difficult to compare the effectiveness of various conservative and operative treatments. This systematic review summarises the current knowledge on spondylolysis and spondylolisthesis and attempts to present a rational approach to the evaluation and management of this condition in children and adolescents.