Although equinus gait is the most common abnormality
in children with spastic cerebral palsy (CP) there is no consistency
in recommendations for treatment, and evidence for best practice
is lacking. The Baumann procedure allows selective fractional lengthening
of the gastrocnemii and soleus muscles but the long-term outcome
is not known. We followed a group of 18 children (21 limbs) with
diplegic CP for ten years using three-dimensional instrumented gait
analysis. The kinematic parameters of the ankle joint improved significantly
following this procedure and were maintained until the end of follow-up.
We observed a normalisation of the timing of the key kinematic and
kinetic parameters, and an increase in the maximum generation of
power of the ankle. There was a low rate of overcorrection (9.5%,
n = 2), and a rate of recurrent equinus similar to that found with
other techniques (23.8%, n = 5). As the procedure does not impair the muscle architecture, and
allows for selective correction of the contracted gastrocnemii and
soleus, it may be recommended as the preferred method for correction
of a mild fixed equinus deformity.
To assess the effectiveness of a modified tibial tubercle osteotomy
as a treatment for arthroscopically diagnosed chondromalacia patellae. A total of 47 consecutive patients (51 knees) with arthroscopically
proven chondromalacia, who had failed conservative management, underwent
a modified Fulkerson tibial tubercle osteotomy. The mean age was
34.4 years (19.6 to 52.2). Pre-operatively, none of the patients
exhibited signs of patellar maltracking or instability in association
with their anterior knee pain. The minimum follow-up for the study
was five years (mean 72.6 months (62 to 118)), with only one patient
lost to follow-up.Objectives
Methods
In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p <
0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 ( The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years.
We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone >
2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped. Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.
There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p <
0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p <
0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantly reduced (p <
0.001). Our study indicates that the increase in the intervertebral disc height after disc replacement changes the geometry at the facet joints. This may have clinical relevance.
Techniques for fixation of fractures of the lateral
malleolus have remained essentially unchanged since the 1960s, but
are associated with complication rates of up to 30%. The fibular
nail is an alternative method of fixation requiring a minimal incision
and tissue dissection, and has the potential to reduce the incidence
of complications. We reviewed the results of 105 patients with unstable fractures
of the ankle that were fixed between 2002 and 2010 using the Acumed
fibular nail. The mean age of the patients was 64.8 years (22 to
95), and 80 (76%) had significant systemic medical comorbidities.
Various different configurations of locking screw were assessed
over the study period as experience was gained with the device.
Nailing without the use of locking screws gave satisfactory stability
in only 66% of cases (4 of 6). Initial locking screw constructs
rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable.
Overall, seven patients had loss of fixation of the fracture and
there were five post-operative wound infections related to the distal
fibula. This lead to the development of the current technique with
a screw across the syndesmosis in addition to a distal locking screw.
In 21 patients treated with this technique there have been no significant
complications and only one superficial wound infection. Good fracture
reduction was achieved in all of these patients. The mean physical
component Short-Form 12, Olerud and Molander score, and American Academy
of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean
of six years post-injury were 46 (28 to 61), 65 (35 to 100) and
83 (52 to 99), respectively. There have been no cases of fibular
nonunion. Nailing of the fibula using our current technique gives good
radiological and functional outcomes with minimal complications,
and should be considered in the management of patients with an unstable
ankle fracture.
Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm ( This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length.
The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.
We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment. The use of intramedullary nails prevented recurrence of deformity and refracture.
Peri-prosthetic fracture after joint replacement in the lower limb is associated with significant morbidity. The primary aim of this study was to investigate the incidence of peri-prosthetic fracture after total hip replacement (THR) and total knee replacement (TKR) over a ten-year period using a population-based linked dataset. Between 1 April 1997 and 31 March 2008, 52 136 primary THRs, 8726 revision THRs, 44 511 primary TKRs, and 3222 revision TKRs were performed. Five years post-operatively, the rate of fracture was 0.9% after primary THR, 4.2% after revision THR, 0.6% after primary TKR and 1.7% after revision TKR. Comparison of survival analysis for all primary and revision arthroplasties showed peri-prosthetic fractures were more likely in females, patients aged >
70 and after revision arthroplasty. Female patients aged >
70 should be warned of a significantly increased risk of peri-prosthetic fracture after hip or knee replacement. The use of adjuvant medical treatment to reduce the effect of peri-prosthetic osteoporosis may be a direction of research for these patients.
Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96). A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device
We report a prospective analysis of clinical
outcome in patients treated with medial patellofemoral ligament
(MPFL) reconstruction using an autologous semitendinosus graft.
The technique includes superolateral portal arthroscopic assessment
before and after graft placement to ensure correct graft tension
and patellar tracking before fixation. Between October 2005 and
October 2010, a total of 201 consecutive patients underwent 219 procedures.
Follow-up is presented for 211 procedures in 193 patients with a
mean age of 26 years (16 to 49), and mean follow-up of 16 months
(6 to 42). Indications were atraumatic recurrent patellar dislocation
in 141 patients, traumatic recurrent dislocation in 50, pain with
subluxation in 14 and a single dislocation with persistent instability
in six. There have been no recurrent dislocations/subluxations.
There was a statistically significant improvement between available pre-
and post-operative outcome scores for 193 patients (all p <
0.001).
Female patients with a history of atraumatic recurrent dislocation
and all patients with history of previous surgery had a significantly
worse outcome (all p <
0.05). The indication for surgery, degree
of dysplasia, associated patella alta, time from primary dislocation
to surgery and evidence of associated cartilage damage at operation
did not result in any significant difference in outcome. This series adds considerably to existing evidence that MPFL
reconstruction is an effective surgical procedure for selected patients
with patellofemoral instability.
We evaluated the histological changes before and after fixation in ten knees of ten patients with osteochondritis dissecans who had undergone fixation of the unstable lesions. There were seven males and three females with a mean age of 15 years (11 to 22). The procedure was performed either using bio-absorbable pins only or in combination with an autologous osteochondral plug. A needle biopsy was done at the time of fixation and at the time of a second-look arthroscopy at a mean of 7.8 months (6 to 9) after surgery. The biopsy specimens at the second-look arthroscopy showed significant improvement in the histological grading score compared with the pre-fixation scores (p <
0.01). In the specimens at the second-look arthroscopy, the extracellular matrix was stained more densely than at the time of fixation, especially in the middle to deep layers of the articular cartilage. Our findings show that articular cartilage regenerates after fixation of an unstable lesion in osteochondritis dissecans.
Posterolateral rotatory instability is the most common type of symptomatic chronic instability of the elbow. In this condition the forearm complex rotates externally in relation to the humerus, causing posterior subluxation or dislocation of the radial head. The lateral ligament complex, radial head and coronoid process are important constraints to posterolateral rotatory instability, and their disruption is involved in the pathogenesis of this condition. The diagnosis relies on a high index of clinical suspicion, active and passive apprehension tests, and examination under anaesthesia. Surgical treatment has given consistently successful results. Open reconstruction of the lateral ligaments with a tendon graft has been the procedure of choice, with arthroscopic techniques emerging as a potential alternative.
Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture.
Medial open-wedge high tibial osteotomy has been gaining popularity in recent years, but adequate supporting material is required in the osteotomy gap for early weight-bearing and rapid union. The purpose of this study was to investigate whether the implantation of a polycaprolactone-tricalcium phosphate composite scaffold wedge would enhance healing of the osteotomy in a micro pig model. We carried out open-wedge high tibial osteotomies in 12 micro pigs aged from 12 to 16 months. A scaffold wedge was inserted into six of the osteotomies while the other six were left open. Bone healing was evaluated after three and six months using plain radiographs, CT scans, measurement of the bone mineral density and histological examination. Complete bone union was obtained at six months in both groups. There was no collapse at the osteotomy site, loss of correction or failure of fixation in either group. Staining with haematoxylin and eosin demonstrated that there was infiltration of new bone tissue into the macropores and along the periphery of the implanted scaffold in the scaffold group. The CT scans and measurement of the bone mineral density showed that at six months specimens in the scaffold group had a higher bone mineral density than in the control group, although the implantation of the polycaprolactone-tricalcium phosphate composite scaffold wedge did not enhance healing of the osteotomy.
The April 2012 Trauma Roundup360 looks at fibula-pro-tibia plating, galeazzi fractures, distal radial fractures in the over 65s, transverse sacral fractures, acute dislocation of the knee, posterior malleolar fractures, immobilising the broken scaphoid, the terrible triad, lower limb amputation after trauma, and whiplash injuries
Between March 2000 and February 2006, we carried out a prospective study of 100 patients with a low-grade isthmic spondylolisthesis (Meyerding grade II or below), who were randomised to receive a single-level and instrumented posterior lumbar interbody fusion with either one or two cages. The minimum follow-up was for two years. At this stage 91 patients were available for review. A total of 47 patients received one cage (group 1) and 44 two cages (group 2). The clinical and radiological outcomes of the two groups were compared. There were no significant differences between the two groups in terms of post-operative pain, Oswestry Disability Score, clinical results, complication rate, percentage of post-operative slip, anterior fusion rate or posterior fusion rate. On the other hand, the mean operating time was 144 minutes (100 to 240) for patients in group 1 and 167 minutes (110 to 270) for those in group 2 (p = 0.0002). The mean blood loss up to the end of the first post-operative day was 756 ml (510 to 1440) in group 1 and 817 ml (620 to 1730) in group 2 (p <
0.0001). Our results suggest that an instrumented posterior lumbar interbody fusion performed with either one or two cages in addition to a bone graft around the cage has a low rate of complications and a high fusion rate. The clinical outcomes were good in most cases, regardless of whether one or two cages had been used.
The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching. The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery.