Advertisement for orthosearch.org.uk
Results 181 - 200 of 268
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1043 - 1043
1 Nov 1997
Smith RM


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 177 - 178
1 Mar 1997
Smith R


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 344 - 344
1 Mar 1997
Smith R


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 171 - 172
1 Jan 1997
GOODLAND JR FLETCHER CDM SMITH MA


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 170 - 170
1 Jan 1997
SMITH RM MATTHEWS S


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 1000 - 1001
1 Nov 1996
Smith R


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 777 - 779
1 Sep 1996
Geutjens GG Langstaff RJ Smith NJ Jefferson D Howell CJ Barton NJ

We carried out a prospective randomised study comparing medial epicondylectomy with anterior transposition for the treatment of ulnar neuropathy at the elbow. The mean follow-up period was 4.5 years and we assessed the patients neurologically and orthopaedically.

Neither procedure appeared to have a significant effect on elbow function. Our study showed better results after medial epicondylectomy; in particular patient satisfaction was higher than after ulnar nerve transposition. There were no significant differences in motor power or nerve-conduction rates and sensory fibres appeared to be more vulnerable to devascularisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 796 - 801
1 Sep 1996
Kiss J Murray DW Turner-Smith AR Bithell JF Bulstrode CJ

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed.

The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane.

The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 658 - 661
1 Jul 1996
Goodlad JR Fletcher CDM Smith MA

We reviewed retrospectively 236 consecutive patients seen in our soft-tissue sarcoma clinic. Of these, 95 had had a primary soft-tissue sarcoma excised elsewhere, but with histologically inadequate resection margins. All these patients had a secondary and wider re-excision.

The tissues removed at the secondary re-excision were examined histologically for the presence of residual tumour. Definite tumour tissue was found in 29 of 55 lower-limb specimens, 16 of 25 upper-limb, 7 of 10 trunk and 4 of 5 head and neck specimens. In 31 cases some residual tumour was visible macroscopically, and in 56 of the 95 patients (59%) the primary tumour had been incompletely excised.

Our results indicate that surgical assessment of the adequacy of excision is very inaccurate and that most local recurrences are the consequence of inadequate primary surgery. The large number of patients who had inadequate initial treatment emphasises the need for a co-ordinated multidisciplinary approach to the management of patients with soft-tissue sarcoma.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 512 - 512
1 May 1996
Smith S


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 51 - 55
1 Jan 1996
Crerand S Dolan M Laing P Bird M Smith ML Klenerman L

We reviewed all patients with a clinically infected foot ulcer attending a specialised neuropathic foot clinic. Neuropathy was confirmed by the inability to feel a 5.07 Semmes-Weinstein hair, areflexia and impaired vibration sense, as measured by a biothesiometer.

Of 40 patients who attended the clinic over a two-year period, six with ischaemic ulcers were excluded. The remaining 34 had plain radiographs of the foot followed by a 99mTc-MDP bone scan. If the latter was positive, an 111In-labelled WBC scan was performed with planar and/or tomographic dual-isotope studies where appropriate. Bone and WBC scans were performed in 31 patients. In ten, isotope imaging showed infection localised to the soft tissues only and conservative treatment was successful in them all. Eighteen patients were treated surgically with excision of the involved bone, which was sent for culture and histological examination.

Dual-isotope scans had a sensitivity of 93% and a specificity of 83%. 99mTc-MDP bone scans with the appropriate 111In-labelled WBC scans can reliably determine the site and extent of osteomyelitis in the neuropathic diabetic foot.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 820 - 829
1 Sep 1995
Carr A Smith R Athanasou N Woods C

The clinical features, investigation, treatment and outcome of two adults with fibrogenesis imperfecta ossium are described. In this rare acquired disorder of bone, normal lamellar collagen is replaced by structurally unsound collagen-deficient tissue, which leads to extreme bone fragility and ununited fractures. Transmission microscopy and SEM showed striking ultrastructural changes in bone structure and mineralisation. Both patients had monoclonal IgG paraproteins in the plasma and one excreted monoclonal lambda light chains in the urine. No abnormal plasma cells were found in the bone marrow and there was no evidence of amyloid deposition in the tissues. In both patients initial treatment with 1 alpha-hydroxycholecalciferol appeared to be ineffective, but in one, repeated courses of melphalan and corticosteroids over three years together with 1 alpha-hydroxycholecalciferol produced striking clinical and histological improvement. The findings in these and other patients strongly suggest that paraproteinaemia is an integral feature of fibrogenesis imperfecta ossium, and this needs further investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 673 - 674
1 Sep 1995
Smith R


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 28 - 33
1 Jan 1995
Athanasou N Pandey R de Steiger R Crook D Smith P

We assessed the efficacy of intraoperative frozen-section histology in detecting infection in failed arthroplasties in 106 hips and knees. We found inflammatory changes consistent with infection (an average of one or more neutrophil polymorphs or plasma cells per high-power field in several samples) in 18 cases; there was a significant growth on bacterial culture in 20 cases. Compared with the bacterial cultures, the frozen sections provided two false-negative results and three false-positive results (sensitivity, 90%; specificity, 96%; and accuracy, 95%). The positive predictive value was 88%, the negative value, 98%. These results support the inclusion of intra-operative frozen-section histology in any protocol for revision arthroplasty for loose components.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 947 - 950
1 Nov 1994
Pearce M Smith M Savidge G

We report the results of supramalleolar varus osteotomy on seven ankles (in six patients) for haemophilic arthropathy and secondary valgus deformity. The operation reduced pain and the frequency of intra-articular bleeding while preserving joint function for a mean of nine years. The procedure is an attractive alternative to the more commonly used surgical option of arthrodesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 713 - 716
1 Sep 1994
Bischoff U Freeman M Smith D Tuke M Gregson P

We studied the wear generated by motion between polished and shot-blasted titanium-alloy (Ti-6Al-4V) or cobalt-chrome alloy (Co-Cr) surfaces and cortical bone in vitro. Semicircular sections of human proximal femoral cortex were reamed to fit metal cylinders of each alloy. The cylinders were then fitted in the bone, loaded and rotated in physiological saline. Ti-alloy resulted in more wear both of the bone and of the metal than did Co-Cr alloy. Metal wear was reduced and bone wear was increased by shot-blasting, a procedure which introduces surface residual stresses and roughens the metal surface. We conclude that when there is gross motion between a metal implant and bone, Ti-alloy is likely to generate more wear debris than Co-Cr alloy. The least wear both of bone and of metal was produced by polished Co-Cr.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 754 - 756
1 Sep 1994
Spalding T Kiss J Kyberd P Turner-Smith A Simpson A

We measured the driver reaction times of 40 patients before total knee replacement (TKR) and 4, 6, 8 and 10 weeks after operation. The ability to perform an emergency stop was assessed as the time taken to achieve a brake pressure of 100 N after a visual stimulus. There were 18 drivers and 11 non-drivers; the latter had longer reaction times. In drivers, the ability to transfer the right foot from accelerator to brake pedal did not recover to preoperative levels for eight weeks after right TKR and was unchanged after left TKR. Patients should be advised that they should not drive for at least eight weeks after right TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 345 - 347
1 May 1994
Smith R


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 258 - 262
1 Mar 1994
Owen T Moran C Smith Pinder I

We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed giant macrophages incorporating numerous particles of high-density polyethylene. The femoral failures were related to a poor intramedullary fit with subsequent subsidence. Using the recommendation for revision as the end point, the cumulative survival rate for prostheses was 91% at six years (95% CI +/- 6%), 73% (+/- 11%) at seven years, and 57% (+/- 20%) at eight years. The result of uncemented PCA hip replacement is satisfactory up to six years, but then increasing failure of the acetabular component appears to be due to polyethylene wear, leading to osteolysis, loosening and component migration. At first, failure is often asymptomatic; routine follow-up of uncemented hip replacement is essential, especially after five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 940 - 941
1 Nov 1993
Khaw F Moran C Pinder I Smith

We made a prospective study of the incidence of fatal pulmonary embolism in patients after total knee replacement with no prophylactic anticoagulation. There were 499 consecutive patients having 527 knee replacements. They all wore anti-thromboembolic stockings and were mobilised 48 hours after surgery. No patient was lost to follow-up. One patient died of pulmonary embolism 22 days after operation. There were no other deaths within three months of operation. The incidence of fatal pulmonary embolism was 0.19% (95% confidence interval: 0 to 0.6%). Fatal pulmonary embolism is rare after total knee replacement without prophylactic anticoagulation and the routine anticoagulation of these patients is of doubtful value.