The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
“Virtual fracture clinics” have been reported as a safe and effective alternative to the traditional fracture clinic. Robust protocols are used to identify cases that do not require further review, with the remainder triaged to the most appropriate subspecialist at the optimum time for review. The objective of this study was to perform a “top-down” analysis of the cost effectiveness of this virtual fracture clinic pathway. National Health Service financial returns relating to our institution were examined for the time period 2009 to 2014 which spanned the service redesign.Objectives
Methods
The August 2013 Shoulder &
Elbow Roundup360 looks at: the sternoclavicular joint revisited; surgical simulators: more than just a fancy idea?; arthroscopic tennis elbow release; costly clavicle stabilisation; a better treatment for tennis elbow?; shock news: surgeons and radiologists agree; overhead athletes and SLAP repair; and total shoulder arthroplasty more effective than hemiarthroplasty
Aseptic loosening of the femoral component is
an important indication for revision surgery in unicompartmental knee
replacement (UKR). A new design of femoral component with an additional
peg was introduced for the cemented Oxford UKR to increase its stability.
The purpose of this study was to compare the primary stability of
the two designs of component. Medial Oxford UKR was performed in 12 pairs of human cadaver
knees. In each pair, one knee received the single peg and one received
the twin peg design. Three dimensional micromotion and subsidence
of the component in relation to the bone was measured under cyclical
loading at flexion of 40° and 70° using an optical measuring system.
Wilcoxon matched pairs signed-rank test was performed to detect
differences between the two groups. There was no significant difference in the relative micromotion
(p = 0.791 and 0.380, respectively) and subsidence (p = 0.301 and
0.176, respectively) of the component between the two groups at
both angles of flexion. Both designs of component offered good strength
of fixation in this cadaver study. Cite this article:
This study aimed to determine the relationship between pedicle-lengthening
distance and bulge-canal volume ratio in cases of lumbar spinal
stenosis, to provide a theoretical basis for the extent of lengthening
in pedicle-lengthening osteotomies. Three-dimensional reconstructions of CT images were performed
for 69 patients (33 men and 36 women) (mean age 49.96 years; 24
to 81). Simulated pedicle-lengthening osteotomies and disc bulge
and spinal canal volume calculations were performed using Mimics
software. Aims
Methods
The purpose of this study was to evaluate the
effect of various non-operative modalities of treatment (transcutaneous
electrical nerve stimulation (TENS); neuromuscular electrical stimulation
(NMES); insoles and bracing) on the pain of osteoarthritis (OA)
of the knee. We conducted a systematic review according to the Preferred Reporting
Items for Systematic Reviews and Meta-Analyses guidelines to identify
the therapeutic options which are commonly adopted for the management
of osteoarthritis (OA) of the knee. The outcome measurement tools used in the different studies were
the visual analogue scale and The Western Ontario and McMaster Universities
Arthritis Index pain index: all pain scores were converted to a
100-point scale. A total of 30 studies met our inclusion criteria: 13 on insoles,
seven on TENS, six on NMES, and four on bracing. The standardised
mean difference (SMD) in pain after treatment with TENS was 1.796,
which represented a significant reduction in pain. The significant
overall effect estimate for NMES on pain was similar to that of
TENS, with a SMD of 1.924. The overall effect estimate of insoles
on pain was a SMD of 0.992. The overall effect of bracing showed
a significant reduction in pain of 1.34. Overall, all four non-operative modalities of treatment were
found to have a significant effect on the reduction of pain in OA
of the knee. This study shows that non-operative physical modalities of treatment
are of benefit when treating OA of the knee. However, much of the
literature reviewed evaluates studies with follow-up of less than
six months: future work should aim to evaluate patients with longer
follow-up. Cite this article:
Dislocation of the acromioclavicular joint is
a relatively common injury and a number of surgical interventions
have been described for its treatment. Recently, a synthetic ligament
device has become available and been successfully used, however,
like other non-native solutions, a compromise must be reached when
choosing non-anatomical locations for their placement. This cadaveric
study aimed to assess the effect of different clavicular anchorage points
for the Lockdown device on the reduction of acromioclavicular joint
dislocations, and suggest an optimal location. We also assessed
whether further stability is provided using a coracoacromial ligament
transfer (a modified Neviaser technique). The acromioclavicular
joint was exposed on seven fresh-frozen cadaveric shoulders. The
joint was reconstructed using the Lockdown implant using four different
clavicular anchorage points and reduction was measured. The coracoacromial
ligament was then transferred to the lateral end of the clavicle,
and the joint re-assessed. If the Lockdown ligament was secured
at the level of the conoid tubercle, the acromioclavicular joint
could be reduced anatomically in all cases. If placed medial or
2 cm lateral, the joint was irreducible. If the Lockdown was placed
1 cm lateral to the conoid tubercle, the joint could be reduced
with difficulty in four cases. Correct placement of the Lockdown
device is crucial to allow anatomical joint reduction. Even when the
Lockdown was placed over the conoid tubercle, anterior clavicle
displacement remained but this could be controlled using a coracoacromial
ligament transfer. Cite this article:
The aim of this study was to investigate the
effect of training on the arthroscopic performance of a group of
medical students and to determine whether all students could be
trained to competence. Thirty-three medical students with no previous
experience of arthroscopy were randomised to a ‘Trained’ or an ‘Untrained’
cohort. They were required to carry out 30 episodes of two simulated
arthroscopic tasks (one shoulder and one knee). The primary outcome variable
was task success at each episode. Individuals achieved competence
when their learning curve stabilised. The secondary outcome was
technical dexterity, assessed objectively using a validated motion
analysis system. Six subjects in the ‘Untrained’ cohort failed to
achieve competence in the shoulder task, compared with one in the ‘Trained’
cohort. During the knee task, two subjects in each cohort failed
to achieve competence. Based on the objective motion analysis parameters,
the ‘Trained’ cohort performed better on the shoulder task (p <
0.05) but there was no significant difference for the knee task
(p >
0.05). Although
To confirm whether developmental dysplasia of
the hip has a risk of hip impingement, we analysed maximum ranges
of movement to the point of bony impingement, and impingement location
using three-dimensional (3D) surface models of the pelvis and femur
in combination with 3D morphology of the hip joint using computer-assisted methods.
Results of computed tomography were examined for 52 hip joints with
DDH and 73 normal healthy hip joints. DDH shows larger maximum extension
(p = 0.001) and internal rotation at 90° flexion (p <
0.001).
Similar maximum flexion (p = 0.835) and external rotation (p = 0.713)
were observed between groups, while high rates of extra-articular
impingement were noticed in these directions in DDH (p <
0.001).
Smaller cranial acetabular anteversion (p = 0.048), centre-edge
angles (p <
0.001), a circumferentially shallower acetabulum,
larger femoral neck anteversion (p <
0.001), and larger alpha
angle were identified in DDH. Risk of anterior impingement in retroverted
DDH hips is similar to that in retroverted normal hips in excessive
adduction but minimal in less adduction. These findings might be
borne in mind when considering the possibility of extra-articular
posterior impingement in DDH being a source of pain, particularly
for patients with a highly anteverted femoral neck. Cite this article:
The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device. The video scores were significantly different for the three groups in all three procedures (p <
0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p <
0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p >
0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment. This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training.
The use of joint-preserving surgery of the hip
has been largely abandoned since the introduction of total hip replacement.
However, with the modification of such techniques as pelvic osteotomy,
and the introduction of intracapsular procedures such as surgical
hip dislocation and arthroscopy, previously unexpected options for
the surgical treatment of sequelae of childhood conditions, including
developmental dysplasia of the hip, slipped upper femoral epiphysis
and Perthes’ disease, have become available. Moreover, femoroacetabular
impingement has been identified as a significant aetiological factor
in the development of osteoarthritis in many hips previously considered to
suffer from primary osteoarthritis. As mechanical causes of degenerative joint disease are now recognised
earlier in the disease process, these techniques may be used to
decelerate or even prevent progression to osteoarthritis. We review
the recent development of these concepts and the associated surgical
techniques. Cite this article:
We describe the mid-term results of a prospective study of total knee replacement in severe valgus knees using an osteotomy of the lateral femoral condyle and computer navigation. There were 15 knees with a mean valgus deformity of 21° (17° to 27°) and a mean follow-up of 28 months (24 to 60). A cemented, non-constrained fixed bearing, posterior-cruciate-retaining knee prosthesis of the same design was used in all cases (Columbus-B. Braun; Aesculap, Tuttlingen, Germany). All the knees were corrected to a mean of 0.5° of valgus (0° to 2°). Flexion of the knee had been limited to a mean of 85° (75° to 110°) pre-operatively and improved to a mean of 105° (90° to 130°) after operation. The mean Knee Society score improved from 37 (30 to 44) to 90 points (86 to 94). Osteotomy of the lateral femoral condyle combined with computer-assisted surgery gave an excellent mid-term outcome in patients undergoing total knee replacement in the presence of severe valgus deformity.
The appearance of the ‘grand-piano sign’ on the anterior resected surface of the femur has been considered to be a marker for correct femoral rotational alignment during total knee replacement. Our study was undertaken to assess quantitatively the morphological patterns on the resected surface after anterior femoral resection with various angles of external rotation, using a computer-simulation technique. A total of 50 right distal femora with varus osteoarthritis in 50 Korean patients were scanned using computerised tomography. Computer image software was used to simulate the anterior femoral cut, which was applied at an external rotation of 0°, 3° and 6° relative to the posterior condylar axis, and parallel to the surgical and clinical epicondylar axes in each case. The morphological patterns on the resected surface were quantified and classified as the ‘grand-piano sign’, ‘the boot sign’ and the ‘butterfly sign’. The surgeon can use the analogy of these quantified sign patterns to ensure that a correct rotational alignment has been obtained intra-operatively.
The December 2014 Children’s orthopaedics Roundup360 looks at: predicting drift in supracondylar fractures; do normal hips dislocate?; the burden of trampoline fractures; muscle eversion activity is strongly predictive of outcome in CTEV; the modified Dunn osteotomy; plaster and moulded casts; and psychology and fractures.
We report the results of Vulpius transverse gastrocsoleus
recession for equinus gait in 26 children with cerebral palsy (CP),
using the Gait Profile Score (GPS), Gait Variable Scores (GVS) and
movement analysis profile. All children had an equinus deformity
on physical examination and equinus gait on three-dimensional gait
analysis prior to surgery. The pre-operative and post-operative
GPS and GVS were statistically analysed. There were 20 boys and
6 girls in the study cohort with a mean age at surgery of 9.2 years
(5.1 to 17.7) and 11.5 years (7.3 to 20.8) at follow-up. Of the
26 children, 14 had spastic diplegia and 12 spastic hemiplegia.
Gait function improved for the cohort, confirmed by a decrease in
mean GPS from 13.4° pre-operatively to 9.0° final review (p <
0.001). The change was 2.8 times the minimal clinically important
difference (MCID). Thus the improvements in gait were both clinically and
statistically significant. The transverse gastrocsoleus recession
described by Vulpius is an effective procedure for equinus gait
in selected children with CP, when there is a fixed contracture
of the gastrocnemius and soleus muscles. Cite this article:
Assessment of skeletal age is important in children’s
orthopaedics. We compared two simplified methods used in the assessment
of skeletal age. Both methods have been described previously with
one based on the appearance of the epiphysis at the olecranon and
the other on the digital epiphyses. We also investigated the influence
of assessor experience on applying these two methods. Our investigation was based on the anteroposterior left hand
and lateral elbow radiographs of 44 boys (mean: 14.4; 12.4 to 16.1
) and 78 girls (mean: 13.0; 11.1 to14.9) obtained during the pubertal
growth spurt. A total of nine observers examined the radiographs
with the observers assigned to three groups based on their experience (experienced,
intermediate and novice). These raters were required to determined
skeletal ages twice at six-week intervals. The correlation between
the two methods was determined per assessment and per observer groups. Interclass
correlation coefficients (ICC) evaluated the reproducibility of
the two methods. The overall correlation between the two methods was r = 0.83
for boys and r = 0.84 for girls. The correlation was equal between
first and second assessment, and between the observer groups (r ≥ 0.82).
There was an equally strong ICC for the assessment effect (ICC ≤ 0.4%)
and observer effect (ICC ≤ 3%) for each method. There was no significant
(p <
0.05) difference between the levels of experience. The two methods are equally reliable in assessing skeletal maturity.
The olecranon method offers detailed information during the pubertal
growth spurt, while the digital method is as accurate but less detailed,
making it more useful after the pubertal growth spurt once the olecranon
has ossified. Cite this article:
The October 2014 Hip &
Pelvis Roundup360 looks at: functional acetabular orientation; predicting re-admission following THR; metal ions and resurfacing; lipped liners increase stability; all anaesthetics equal in hip fracture surgery; revision hip surgery in very young patients; and uncemented hips.