In the UK we have many surgeon inventors – surgeons who innovate and create new ways of doing things, who invent operations, who design new instruments to facilitate surgery or design new implants for using in patients. However truly successful surgeon inventors are a rare breed and they need to develop additional knowledge and skills during their career in order to push forward their devices and innovations. This article reviews my own experiences as a surgeon inventor and the highs and lows over the whole of my surgical career.
The aim of this study was to assess hypertrophy of the extra-articular
tendon of the long head of biceps (LHB) in patients with a rotator
cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159
women, mean age 62.6 years; 25 to 81) with unilateral symptomatic
rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon
in the bicipital groove was measured pre-operatively in both shoulders
using ultrasound. There were 154 asymptomatic rotator cuff tears
in the contralateral shoulder. Comparisons were made between those
with a symptomatic tear, an asymptomatic tear and those with no
rotator cuff tear. In the affected shoulders, the CSAs were compared
in relation to the location and size of the rotator cuff tear. Aims
Patients and Methods
In this study, we describe a morphological classification
for greater tuberosity fractures of the proximal humerus. We divided
these fractures into three types: avulsion, split and depression.
We retrospectively reviewed all shoulder radiographs showing isolated
greater tuberosity fractures in a Level I trauma centre between
July 2007 and July 2012. We identified 199 cases where records and
radiographs were reviewed and included 79 men and 120 women with
a mean age of 58 years (23 to 96). The morphological classification
was applied to the first 139 cases by three reviewers on two occasions
using the Kappa statistic and compared with the AO and Neer classifications.
The inter- and intra-observer reliability of the morphological classification
was 0.73 to 0.77 and 0.69 to 0.86, respectively. This was superior
to the Neer (0.31 to 0.35/0.54 to 0.63) and AO (0.30 to 0.32/0.59
to 0.65) classifications. The distribution of avulsion, split and
depression type fractures was 39%, 41%, and 20%, respectively. This
classification of greater tuberosity fractures is more reliable
than the Neer or AO classifications. These distinct fracture morphologies
are likely to have implications in terms of pathophysiology and
surgical technique. Cite this article:
Radiostereometric analysis (RSA) allows an extremely accurate
measurement of early micromotion of components following arthroplasty. In this study, RSA was used to measure the migration of 11 partially
cemented fluted pegged glenoid components in patients with osteoarthritis
who underwent total shoulder arthroplasty using an improved surgical
technique (seven men, four women, mean age 68). Patients were evaluated
clinically using the American Shoulder and Elbow Surgeons (ASES)
and Constant-Murley scores and by CT scans two years post-operatively. Aims
Patients and Methods
Controversy surrounds the management of displaced
three- and four-part fractures of the proximal humerus. The percutaneous
Resch technique of stabilisation involves minimal soft-tissue dissection
and a reduced risk of stiffness and avascular necrosis. However,
it requires a second operation to remove Kirschner wires and the
humeral block. We describe a modification of this technique that
dispenses with the need for this second operation and relies on
a sequential pattern of screw placement. We report the outcome of
32 three- or four-part fractures of the proximal humerus treated
in this way at a mean follow-up of 3.8 years (2 to 8)). There were
14 men and 18 women with a mean age of 56 years (28 to 83). At final
follow-up the mean Oxford shoulder scores were 38 (31 to 44) and
39 (31 to 42), and the mean Constant scores were 79 (65 to 92) and
72 (70 to 80) for three- and four-part fractures, respectively. We
further analysed the results in patients aged <
60 years with
high-energy fractures and those aged ≥ 60 years with osteoporotic
fractures. There were no cases of nonunion or avascular necrosis. The results were good and comparable to those previously reported
for the Resch technique and other means of fixation for proximal
humeral fractures. We would recommend this modification of the technique
for the treatment of displaced three-part and four-part fractures
in patients both younger and older than 60 years of age.
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior dislocations of the shoulder underwent
a Latarjet procedure and were reviewed at a mean of 8.3 years (1
to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°)
to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°)
to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to
100) at the final follow-up. Radiologically, all shoulders showed
a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes
of the glenohumeral joint were observed in five shoulders (36%)
pre-operatively and in eight shoulders (57%) post-operatively.
Re-dislocation during a seizure occurred in six shoulders (43%).
Five of these patients underwent revision surgery using a bone buttress
from the iliac crest and two of these patients re-dislocated due
to a new seizure. Due to the unacceptably high rate of re-dislocation after surgery
in these patients, the most important means of reducing the incidence
of further dislocation is the medical management of the seizures.
The Latarjet procedure should be reserved for the well-controlled
patient with epilepsy who has recurrent anterior dislocation of
the shoulder during activities of daily living.
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods
We describe the early results of glenoplasty as part of the technique of operative reduction of posterior dislocation of the shoulder in 29 children with obstetric brachial plexus palsy. The mean age at operation was five years (1 to 18) and they were followed up for a mean of 34 months (12 to 67). The mean Mallet score increased from 8 (5 to 13) to 12 (8 to 15) at final follow-up (p <
0.001). The mean passive forward flexion was increased by 18° (p = 0.017) and the mean passive abduction by 24° (p = 0.001). The mean passive lateral rotation also increased by 54° (p <
0.001), but passive medial rotation was reduced by a mean of only 7°. One patient required two further operations. Glenohumeral stability was achieved in all cases.
Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.
We retrospectively studied 14 patients with proximal and diaphyseal tumours and disappearing bone (Gorham’s) disease of the humerus treated with wide resection and reconstruction using an allograft-resurfacing composite (ARC). There were ten women and four men, with a mean age of 35 years (8 to 69). At a mean follow-up of 25 months (10 to 89), two patients had a fracture of the allograft. In one of these it was revised with a similar ARC and in the other with an intercalary prosthesis. A further patient had an infection and a fracture of the allograft that was revised with a megaprosthesis. In all patients with an ARC, healing of the ARC-host bone interface was observed. One patient had failure of the locking mechanism of the total elbow replacement. The mean post-operative Musculoskeletal Tumor Society score for the upper extremity was 77% (46.7% to 86.7%), which represents good and excellent results; one patient had a poor result (46.7%). In the short term ARC effectively relieves pain and restores shoulder function in patients with wide resection of the proximal humerus. Fracture and infection remain significant complications.
Gunshot injuries to the shoulder are rare and
difficult to manage. We present a case series of seven patients
who sustained a severe shoulder injury to the non-dominant side
as a result of a self-inflicted gunshot wound. We describe the injury
as ‘suicide shoulder’ caused by upward and outward movement of the
gun barrel as the trigger is pulled. All patients were male, with
a mean age of 32 years (21 to 48). All were treated at the time
of injury with initial repeated debridement, and within four weeks
either by hemiarthroplasty (four patients) or arthrodesis (three patients).
The hemiarthroplasty failed in one patient after 20 years due to
infection and an arthrodesis was attempted, which also failed due
to infection. Overall follow-up was for a mean of 26 months (12
to 44). All four hemiarthroplasty implants were removed with no
feasible reconstruction ultimately possible, resulting in a poor functional
outcome and no return to work. In contrast, all three primary arthrodeses
eventually united, with two patients requiring revision plating
and grafting. These patients returned to work with a good functional
outcome. We recommend arthrodesis rather than replacement as the
treatment of choice for this challenging injury. Cite this article:
Inherent disadvantages of reverse shoulder arthroplasty
designs based on the Grammont concept have raised a renewed interest
in less-medialised designs and techniques. The aim of this study
was to evaluate the outcome of reverse shoulder arthroplasty (RSA)
with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed
for the treatment of rotator-cuff-deficient shoulders with glenohumeral
arthritis. A total of 97 arthroplasties in 92 patients (53 women
and 44 men, mean age 67 years (standard deviation ( The Bayley–Walker prosthesis provides reliable pain relief and
reasonable functional improvement for patients with symptomatic
cuff-deficient shoulders. Compared with other designs of RSA, it
offers a modest improvement in forward elevation, but restores external
rotation to some extent and prevents scapular notching. A longer
follow-up is required to assess the survival of the prosthesis and
the clinical performance over time. Cite this article:
In this study, we evaluated patient-reported
outcomes, the rate of revision and the indications for revision
following resurfacing hemiarthroplasty of the shoulder in patients
with osteoarthritis. All patients with osteoarthritis who underwent primary resurfacing
hemiarthroplasty and reported to the Danish Shoulder Arthroplasty
Registry (DSR), between January 2006 and December 2010 were included.
There were 772 patients (837 arthroplasties) in the study. The Western
Ontario Osteoarthritis of the Shoulder (WOOS) index was used to
evaluate patient-reported outcome 12 months (10 to 14) post-operatively.
The rates of revision were calculated from the revisions reported
to the DSR up to December 2011 and by checking deaths with the Danish National
Register of Persons. A complete questionnaire was returned by 688 patients (82.2%).
The mean WOOS was 67 (0 to 100). A total of 63 hemiarthroplasties
(7.5%) required revision; the cumulative five-year rate of revision
was 9.9%. Patients aged <
55 years had a statistically significant
inferior WOOS score, which exceeded the minimal clinically important
difference, compared with older patients (mean difference 14.2 (8.8;
95% CI 19.6; p <
0.001), but with no increased risk of revision.
There was no significant difference in the mean WOOS or the risk
of revision between designs of resurfacing hemiarthroplasty. Cite this article:
The February 2015 Shoulder &
Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow
An internal rotation contracture is a common complication of obstetric brachial plexus palsy. We describe the operative treatment of seven children with a recurrent internal rotation contracture of the shoulder following earlier corrective surgery which included subscapularis slide and latissimus dorsi transfer. We performed z-lengthening of the tendon of the subscapularis muscle and transferred the lower trapezius muscle to the infraspinatus tendon. Two years postoperatively the mean gain in active external rotation was 47.1°, which increased to 54.3° at four years. Lengthening of the tendon of subcapularis and lower trapezius transfer to infraspinatus improved the range of active external rotation in patients who had previously had surgery for an internal rotation contracture.
Rotator cuff tears are among the most frequent upper extremity injuries. Current treatment strategies do not address the poor quality of the muscle and tendon following chronic rotator cuff tears. Hypoxia-inducible factor-1 alpha (HIF-1α) is a transcription factor that activates many genes that are important in skeletal muscle regeneration. HIF-1α is inhibited under normal physiological conditions by the HIF prolyl 4-hydroxylases (PHDs). In this study, we used a pharmacological PHD inhibitor, GSK1120360A, to enhance the activity of HIF-1α following the repair of a chronic cuff tear, and measured muscle fibre contractility, fibrosis, gene expression, and enthesis mechanics. Chronic supraspinatus tears were induced in adult rats, and repaired 28 days later. Rats received 0 mg/kg, 3 mg/kg, or 10 mg/kg GSK1120360A daily. Collagen content, contractility, fibre type distribution and size, the expression of genes involved in fibrosis, lipid accumulation, atrophy and inflammation, and the mechanical properties of the enthesis were then assessed two weeks following surgical repair.Objectives
Methods
Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the entry point and orientation of the
central guide wire used for reaming the glenoid and the introduction
of the component. Manual segmentation was performed on post-operative
CT scans to compare the planned and the actual position of the entry
point (mm) and orientation of the component (°).Aims
Patients and Methods
We describe the longer term clinical and radiological findings in a prospectively followed series of 49 rheumatoid patients (58 shoulders) who had undergone Neer II total shoulder replacement. The early and intermediate results have been published previously. At a mean follow-up of 19.8 years (16.5 to 23.8) 14 shoulders survived. Proximal migration of the humeral component was associated with progressive loosening of the glenoid and humeral components, but was independent of the state of the rotator cuff at the time of operation. Despite these changes the range of movement was preserved. Most patients had little or no pain in the shoulder, could sleep undisturbed and could attend to personal hygiene and grooming.
Our aim was to investigate the outcomes of patients with a displaced
fracture of the glenoid fossa who are treated conservatively. There
is little information in the literature about the treatment of these
rare injuries non-operatively. We reviewed 24 patients with a mean age of 52 years (19 to 81)
at a mean of 5.6 years (11 months to 18 years) after the injury.Aims
Patients and Methods
The treatment of osteochondral lesions and osteoarthritis
remains an ongoing clinical challenge in orthopaedics. This review
examines the current research in the fields of cartilage regeneration,
osteochondral defect treatment, and biological joint resurfacing, and
reports on the results of clinical and pre-clinical studies. We
also report on novel treatment strategies and discuss their potential
promise or pitfalls. Current focus involves the use of a scaffold
providing mechanical support with the addition of chondrocytes or mesenchymal
stem cells (MSCs), or the use of cell homing to differentiate the
organism’s own endogenous cell sources into cartilage. This method
is usually performed with scaffolds that have been coated with a
chemotactic agent or with structures that support the sustained
release of growth factors or other chondroinductive agents. We also
discuss unique methods and designs for cell homing and scaffold
production, and improvements in biological joint resurfacing. There
have been a number of exciting new studies and techniques developed
that aim to repair or restore osteochondral lesions and to treat
larger defects or the entire articular surface. The concept of a
biological total joint replacement appears to have much potential. Cite this article: