Advertisement for orthosearch.org.uk
Results 181 - 200 of 484
Results per page:
Bone & Joint Open
Vol. 1, Issue 5 | Pages 167 - 174
31 May 2020
Marson BA Craxford S Deshmukh SR Grindlay D Manning J Ollivere BJ

Aims

To analyze outcomes reported in trials of childhood fractures.

Methods

OVID MEDLINE, Embase, and Cochrane CENTRAL databases were searched on the eighth August 2019. A manual search of trial registries, bibliographic review and internet search was used to identify additional studies. 11,476 studies were screened following PRISMA guidelines. 100 trials were included in the analysis. Data extraction was completed by two researchers for each trial. Study quality was not evaluated. Outcomes reported by trials were mapped onto domains in the World Health Organization (WHO) International Classification of Function framework.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 779 - 787
1 Jun 2020
Gupta S Griffin AM Gundle K Kafchinski L Zarnett O Ferguson PC Wunder J

Aims

Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary bone tumour create a large segmental defect in the pelvic ring. The management of this defect is controversial as the surgeon may choose to reconstruct it or not. When no reconstruction is undertaken, the residual ilium collapses back onto the remaining sacrum forming an iliosacral pseudarthrosis. The aim of this study was to evaluate the long-term oncological outcome, complications, and functional outcome after pelvic resection without reconstruction.

Methods

Between 1989 and 2015, 32 patients underwent a Type I or Type I/IV pelvic resection without reconstruction for a primary bone tumour. There were 21 men and 11 women with a mean age of 35 years (15 to 85). The most common diagnosis was chondrosarcoma (50%, n = 16). Local recurrence-free, metastasis-free, and overall survival were assessed using the Kaplan-Meier method. Patient function was evaluated using the Musculoskeletal Tumour Society (MSTS) and Toronto Extremity Salvage Score (TESS).


Bone & Joint 360
Vol. 9, Issue 2 | Pages 18 - 19
1 Apr 2020


Bone & Joint 360
Vol. 9, Issue 5 | Pages 4 - 9
1 Oct 2020
Matthews E Waterson HB Phillips JR Toms AD


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 64 - 71
1 Jan 2020
Tsuda Y Fujiwara T Stevenson JD Parry MC Tillman R Abudu A

Aims

The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma.

Methods

A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11).


Bone & Joint Open
Vol. 1, Issue 9 | Pages 585 - 593
24 Sep 2020
Caterson J Williams MA McCarthy C Athanasou N Temple HT Cosker T Gibbons M

Aims

The aticularis genu (AG) is the least substantial and deepest muscle of the anterior compartment of the thigh and of uncertain significance. The aim of the study was to describe the anatomy of AG in cadaveric specimens, to characterize the relevance of AG in pathological distal femur specimens, and to correlate the anatomy and pathology with preoperative magnetic resonance imaging (MRI) of AG.

Methods

In 24 cadaveric specimens, AG was identified, photographed, measured, and dissected including neurovascular supply. In all, 35 resected distal femur specimens were examined. AG was photographed and measured and its utility as a surgical margin examined. Preoperative MRIs of these cases were retrospectively analyzed and assessed and its utility assessed as an anterior soft tissue margin in surgery. In all cadaveric specimens, AG was identified as a substantial structure, deep and separate to vastus itermedius (VI) and separated by a clear fascial plane with a discrete neurovascular supply. Mean length of AG was 16.1 cm ( ± 1.6 cm) origin anterior aspect distal third femur and insertion into suprapatellar bursa. In 32 of 35 pathological specimens, AG was identified (mean length 12.8 cm ( ± 0.6 cm)). Where AG was used as anterior cover in pathological specimens all surgical margins were clear of disease. Of these cases, preoperative MRI identified AG in 34 of 35 cases (mean length 8.8 cm ( ± 0.4 cm)).


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment.

Methods

A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 100 - 103
1 Feb 1965
Gleave JAE

1. This is a report on the production of sockets for above-knee prostheses utilising a composite laminate of synthetic and natural materials and using a principle of total stump contact with the socket, which before fitting is shaped to suit individual stump contours. 2. A new method of taking casts is described, as is the production of the socket, and observations on the use of the prosthesis over the last two and a half years are made


Bone & Joint Research
Vol. 9, Issue 9 | Pages 534 - 542
1 Sep 2020
Varga P Inzana JA Fletcher JWA Hofmann-Fliri L Runer A Südkamp NP Windolf M

Aims

Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA).

Methods

A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 319 - 321
1 Mar 1988
Carr A Macdonald D Waterhouse N

The use of an osteocutaneous free fibular graft as a single-stage reconstructive procedure for composite tissue loss is increasingly common. Detailed anatomical study in cadavers of the blood supply to the graft demonstrates cutaneous arteries arising from the peroneal artery and then passing along the posterior surface of the lateral intermuscular septum. These vessels pierce the crural fascia and then ramify to supply the skin. Knowledge of the vascular anatomy of the skin overlying the fibula is essential to the success of the graft


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 838 - 844
1 Jul 2020
Chen L Hong G Hong Z Lin T Chen Z Zhang Q He W

Aims

The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications.

Methods

A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems).


Bone & Joint Open
Vol. 1, Issue 7 | Pages 339 - 345
3 Jul 2020
MacDessi SJ Griffiths-Jones W Harris IA Bellemans J Chen DB

Aims

An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis.

Methods

A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 922 - 930
1 Aug 2003
Ushio K Oka† M Hyon S Yura S Toguchida J Nakamura T

The use of a composite osteochondral device for simulating partial hemiarthroplasty was examined. The device was composed of a polyvinyl alcohol hydrogel and a titanium fibre mesh, acting as artificial cartilage and as porous artificial bone, respectively. The titanium fibre mesh was designed to act as an interface material, allowing firm attachment to both the polyvinyl alcohol gel (through injection moulding) and the femoral joint surface (through bony ingrowth). We implanted 22 of these devices into canine femoral heads. Histological findings from the acetabular cartilage and synovial membrane, as well as the attachment of the prosthesis to bone, were examined up until one year after operation. No marked pathological changes were found and firm attachment of the device to the underlying bone was confirmed. The main potential application for this device is for partial surface replacement of the femoral head after osteonecrosis. Other applications could include articular resurfacing and the replacement of intervertebral discs


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 367 - 375
1 Aug 1981
Morrissy R Riseborough E Hall J

Forty cases of congenital pseudarthrosis of the tibia were reviewed. The results were assessed so as to emphasise function rather than simply the presence or absence of union. At the time of review, 14 patients had undergone amputation; eight others had non-union or tenuous union. No surgical procedure except the Farmer operation (a composite skin and bone pedicle graft from the other leg) showed any clear superiority. Among the factors associated with a poor result were considerable shortening, older children, and rapid resorption of the bone graft. It is felt that congenital pseudarthrosis of the tibia is a biological problem and not merely a mechanical one; consequently biological approaches to its treatment are needed


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1063 - 1068
1 Sep 2001
Li XD Hu YY

We have developed a new drug-delivery system using reconstituted bone xenograft to treat chronic osteomyelitis. This material, which has the capabilities of osteoinduction and osteoconduction, was supplemented with up to 2000 times the minimum inhibitory concentration of gentamicin against Staphylococcus aureus to prepare a gentamicin-reconstituted bone xenograft-composite (G-RBX-C). In a rabbit model, we evaluated the release of gentamicin from this composite in vivo, its capability for induction of ectopic bone and the repair of segmental defects of the radius. There was a high level of concentration of antibiotics, which was sustained for at least ten days. In the study of induction of ectopic bone, there was abundant woven bone in the G-RBX-C group two weeks after operation. At 16 weeks after implantation of G-RBX-C the radial defects had been repaired, with the formation of lamellar bone and recanalisation of the marrow cavity. Our findings suggest that G-RBX-C may be useful in the treatment of chronic osteomyelitis


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 547 - 549
1 May 2020
Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 17 - 22
1 Jan 1988
Geesink R de Groot K Klein C

Implants of solid sintered hydroxyapatite form very tight bonds with living bone, but are susceptible to fatigue failure. This problem can be overcome by using plasma-sprayed apatite coatings on titanium implants. A very strong bond is formed between bone and this composite material; this was studied in canine bone with plug implants, avoiding any mechanical retention. Mechanical testing showed an interface shear strength at six weeks of 49 MPa with a maximum of 64 MPa after six months. There was histological evidence of direct bonding between the apatite coating and living bone while uncoated control plugs were easily extracted. The results indicate that apatite-coated implants can form a chemical fixation with a strength comparable to that of cortical bone itself. This fixation is far stronger than that provided by current cemented or uncemented fixation techniques


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 2 | Pages 331 - 339
1 May 1974
Elves MW Salama R

1. The humoral immune response of rats against sheep iliac bone grafts has been examined. 2. Fresh, marrow-containing grafts elicited a brisk and sustained antibody response. Attempts to wash out the marrow were not uniformly successful in removing cellular antigens from the grafts. 3. Decalcifying and freezing bone grafts at —20 degrees Celsius do not impair immunogenicity to any significant extent. Immunogenicity was found to be reduced in grafts subjected to freeze-drying. 4. Deproteinised Oswestry bone grafts and Kiel grafts gave rise to antibody production in a few recipients, and in the case of the former this response did not occur until after six or seven weeks from grafting. 5. The highest degree of osteogenesis in composite bone xenograft-autografts was found by Salama and colleagues (1973) to occur in Oswestry bone grafts. It is suggested that osteogenesis in xenografts may be impaired by an immune response


Bone & Joint Research
Vol. 9, Issue 6 | Pages 272 - 278
1 Jun 2020
Tapasvi S Shekhar A Patil S Pandit H

Aims

The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.

Methods

A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 772 - 778
1 Jun 2020
Kim Y Jang WY Park JW Park YK Cho HS Han I Kim H

Aims

For paediatric and adolescent patients with growth potential, preservation of the physiological joint by transepiphyseal resection (TER) of the femur confers definite advantages over arthroplasty procedures. We hypothesized that the extent of the tumour and changes in its extent after neoadjuvant chemotherapy are essential factors in the selection of this procedure, and can be assessed with MRI. The oncological and functional outcomes of the procedure were reviewed to confirm its safety and efficacy.

Methods

We retrospectively reviewed 16 patients (seven male and nine female, mean age 12.2 years (7 to 16)) with osteosarcoma of the knee who had been treated by TER. We evaluated the MRI scans before and after neoadjuvant chemotherapy for all patients to assess the extent of the disease and the response to treatment.