Advertisement for orthosearch.org.uk
Results 181 - 200 of 2417
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 974 - 978
1 Sep 2004
Thomas SR Shukla D Latham PD

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem debonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pain. At revision the stems were severely corroded in a pattern which was typical of crevice corrosion. Symptoms were eliminated after revision to an all-stainless steel femoral prosthesis of the same design. We discuss the likely causes for the corrosion. The combination of a titanium stem and cement appears to facilitate crevice corrosion


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 167 - 170
1 Jan 1999
Reading AD McCaskie AW Gregg PJ

Radiological assessment of the cement mantle is used routinely to determine the outcome of total hip replacement. We performed a simulated replacement arthroplasty on cadaver femora and took standard postoperative radiographs. The femora were then sectioned into 7 mm slices starting at the calcar, and high-resolution faxitron radiographs were taken of these sections. Analysis of the faxitron images showed that defects in the cement mantle were observed up to 100 times more frequently than on the standard films. We therefore encourage the search for a better technique in assessing the cement mantle


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 322 - 327
1 Mar 2012
Morley JR Blake SM Hubble MJW Timperley AJ Gie GA Howell JR

The removal of all prosthetic material and a two-stage revision procedure is the established standard management of an infected total hip replacement (THR). However, the removal of well-fixed femoral cement is time-consuming and can result in significant loss of bone stock and femoral shaft perforation or fracture. We report our results of two-stage revision THR for treating infection, with retention of the original well-fixed femoral cement mantle in 15 patients, who were treated between 1989 and 2002. Following partial excision arthroplasty, patients received local and systemic antibiotics and underwent reconstruction and re-implantation at a second-stage procedure, when the infection had resolved. The mean follow-up of these 15 patients was 82 months (60 to 192). Two patients had positive microbiology at the second stage and were treated with six weeks of appropriate antibiotics; one of these developed recurrent infection requiring further revision. Successful eradication of infection was achieved in the remaining 14 patients. We conclude that when two-stage revision is used for the treatment of peri-prosthetic infection involving a THR, a well-fixed femoral cement mantle can be safely left in situ, without compromising the treatment of infection. Advantages of this technique include a shorter operating time, reduced loss of bone stock and a technically more straightforward second-stage procedure


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 649 - 653
1 May 2015
Hawi N Kendoff D Citak M Gehrke T Haasper C

Knee arthrodesis is a potential salvage procedure for limb preservation after failure of total knee arthroplasty (TKA) due to infection. In this study, we evaluated the outcome of single-stage knee arthrodesis using an intramedullary cemented coupled nail without bone-on-bone fusion after failed and infected TKA with extensor mechanism deficiency. Between 2002 and 2012, 27 patients (ten female, 17 male; mean age 68.8 years; 52 to 87) were treated with septic single-stage exchange. Mean follow-up duration was 67.1months (24 to 143, n = 27) (minimum follow-up 24 months) and for patients with a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A subjective patient evaluation (Short Form (SF)-36) was obtained, in addition to the Visual Analogue Scale (VAS). The mean VAS score was 1.44 (SD 1.48). At final follow-up, four patients had recurrent infections after arthrodesis (14.8%). Of these, three patients were treated with a one-stage arthrodesis nail exchange; one of the three patients had an aseptic loosening with a third single-stage exchange, and one patient underwent knee amputation for uncontrolled sepsis at 108 months. All patients, including the amputee, indicated that they would choose arthrodesis again. Data indicate that a single-stage knee arthrodesis offers an acceptable salvage procedure after failed and infected TKA. Cite this article: Bone Joint J 2015;97-B:649–53


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1158 - 1163
1 Sep 2009
Clauss M Luem M Ochsner PE Ilchmann T

The original forged Müller straight stem (CoNiCr) has shown excellent ten- to 15-year results. We undertook a long-term survival analysis with special emphasis on radiological changes within a 20-year period of follow-up. In all, 165 primary total hip replacements, undertaken between July 1984 and June 1987 were followed prospectively. Clinical follow-up included a standardised clinical examination, and radiological assessment was based on a standardised anteroposterior radiograph of the pelvis, which was studied for the presence of osteolysis, debonding and cortical atrophy. Survival of the stem with revision for any reason was 81% (95% confidence interval (CI), 76 to 86) at 20 years and for aseptic loosening 87% (95% CI, 82 to 90). At the 20-year follow-up, 15 of the surviving 36 stems showed no radiological changes. Debonding (p = 0.005), osteolysis (p = 0.003) and linear polyethylene wear (p = 0.016) were associated with aseptic loosening, whereas cortical atrophy was not associated with failure (p = 0.008). The 20-year results of the Müller straight stem are comparable to those of other successful cemented systems with similar follow-up. Radiological changes are frequently observed, but with a low incidence of progression, and rarely result in revision. Cortical atrophy appears to be an effect of ageing and not a sign of loosening of the femoral component


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 636 - 642
1 May 2013
Gøthesen Ø Espehaug B Havelin L Petursson G Lygre S Ellison P Hallan G Furnes O

We evaluated the rates of survival and cause of revision of seven different brands of cemented primary total knee replacement (TKR) in the Norwegian Arthroplasty Register during the years 1994 to 2009. Revision for any cause, including resurfacing of the patella, was the primary endpoint. Specific causes of revision were secondary outcomes. Three posterior cruciate-retaining (PCR) fixed modular-bearing TKRs, two fixed non-modular bearing PCR TKRs and two mobile-bearing posterior cruciate-sacrificing TKRs were investigated in a total of 17 782 primary TKRs. The median follow-up for the implants ranged from 1.8 to 6.9 years. Kaplan-Meier 10-year survival ranged from 89.5% to 95.3%. Cox’s relative risk (RR) was calculated relative to the fixed modular-bearing Profix knee (the most frequently used TKR in Norway), and ranged from 1.1 to 2.6. The risk of revision for aseptic tibial loosening was higher in the mobile-bearing LCS Classic (RR 6.8 (95% confidence interval (CI) 3.8 to 12.1)), the LCS Complete (RR 7.7 (95% CI 4.1 to 14.4)), the fixed modular-bearing Duracon (RR 4.5 (95% CI 1.8 to 11.1)) and the fixed non-modular bearing AGC Universal TKR (RR 2.5 (95% CI 1.3 to 5.1)), compared with the Profix. These implants (except AGC Universal) also had an increased risk of revision for femoral loosening (RR 2.3 (95% CI 1.1 to 4.8), RR 3.7 (95% CI 1.6 to 8.9), and RR 3.4 (95% CI 1.1 to 11.0), respectively). These results suggest that aseptic loosening is related to design in TKR. Cite this article: Bone Joint J 2013;95-B:636–42


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 911 - 916
1 Jul 2013
Small SR Ritter MA Merchun JG Davis KE Rogge RD

Stress shielding resulting in diminished bone density following total knee replacement (TKR) may increase the risk of migration and loosening of the prosthesis. This retrospective study was designed to quantify the effects of the method of fixation on peri-prosthetic tibial bone density beneath cemented and uncemented tibial components of similar design and with similar long-term survival rates. Standard radiographs taken between two months and 15 years post-operatively were digitised from a matched group of TKRs using cemented (n = 67) and uncemented (n = 67) AGC tibial prostheses. Digital radiograph densitometry was used to quantify changes in bone density over time. Age, length of follow-up, gender, body mass index and alignment each significantly influenced the long-term pattern of peri-prosthetic bone density. Similar long-term changes in density irrespective of the method of fixation correlated well with the high rate of survival of this TKR at 20 years, and suggest that cemented and uncemented fixation are both equally viable. Cite this article: Bone Joint J 2013;95-B:911–16


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1417 - 1421
1 Nov 2008
de Kam DCJ Klarenbeek RLWA Gardeniers JWM Veth RPH Schreurs BW

We evaluated the outcome of 104 consecutive primary cemented Exeter femoral components in 78 patients (34 men, 44 women) under the age of 40 years who underwent total hip replacement between October 1993 and May 2004. The mean age at operation was 31 years (16 to 39). No hip was lost to follow-up, but three patients (four hips) died. None of the deaths were related to the surgery. At a mean follow-up of 6.2 years (2 to 13), three femoral components had been revised for septic loosening. Using Kaplan-Meier survival analysis, the seven-year survival of the component with revision for any reason as the endpoint was 95.8% (95% confidence interval 86.67 to 98.7). The seven-year survival with aseptic femoral loosening as the endpoint was 100% (95% confidence interval 100). The cemented Exeter femoral component in patients under the age of 40 shows promising medium-term results. As it is available in a wide range of sizes and offsets, we could address all types of anatomical variation in this series without the need for custom-made components


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1093 - 1097
1 Aug 2011
Weiss KR Bhumbra R Biau DJ Griffin AM Deheshi B Wunder JS Ferguson PC

Pathological fractures of the humerus are associated with pain, morbidity, loss of function and a diminished quality of life. We report our experience of stabilising these fractures using polymethylmethacrylate and non-locking plates. We undertook a retrospective review over 20 years of patients treated at a tertiary musculoskeletal oncology centre. Those who had undergone surgery for an impending or completed pathological humeral fracture with a diagnosis of metastatic disease or myeloma were identified from our database. There were 63 patients (43 men, 20 women) in the series with a mean age of 63 years (39 to 87). All had undergone intralesional curettage of the tumour followed by fixation with intramedullary polymethylmethacrylate and plating. Complications occurred in 14 patients (22.2%) and seven (11.1%) required re-operation. At the latest follow-up, 47 patients (74.6%) were deceased and 16 (25.4%) were living with a mean follow-up of 75 months (1 to 184). A total of 54 (86%) patients had no or mild pain and 50 (80%) required no or minimal assistance with activities of daily living. Of the 16 living patients none had pain and all could perform activities of daily living without assistance. Intralesional resection of the tumour, filling of the cavity with cement, and plate stabilisation of the pathological fracture gives immediate rigidity and allows an early return of function without the need for bony union. The patient’s local disease burden is reduced, which may alleviate tumour-related pain and slow the progression of the disease. The cemented-plate technique provides a reliable option for the treatment of pathological fractures of the humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 851 - 857
1 Jul 2007
Webb JCJ Spencer RF

Polymethylmethacrylate remains one of the most enduring materials in orthopaedic surgery. It has a central role in the success of total joint replacement and is also used in newer techniques such as percutaneous vertebroplasty and kyphoplasty. This article describes the current uses and limitations of polymethylmethacrylate in orthopaedic surgery. It focuses on its mechanical and chemical properties and links these to its clinical performance. The behaviour of antibiotic-loaded bone cement are discussed, together with areas of research that are now shedding light upon the behaviour of this unique biomaterial


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 748 - 752
1 Jul 2003
Nyffeler RW Anglin C Sheikh R Gerber C

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantle were studied in human glenoid bone. The lowest pull-out forces, 20 ± 5 N, were for cylindrical pegs with a smooth surface fixed in the glenoid with a thin cement mantle. The highest values, 425 ± 7 N, were for threaded pegs fixed with a thicker cement mantle. Increasing the diameter of the hole into which the peg is inserted from 5.2 to 6.2 mm thereby increasing the thickness of the cement mantle, improved the mean pull-out force for the pegs tested


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 842 - 845
1 Aug 2000
Wroblewski BM Siney PD Fleming PA Bobak P

The calcar femorale is a vertical plate of bone lying deep to the lesser trochanter and is formed as a result of traction of the iliopsoas which separates the femoral cortex into two distinct layers, the calcar femorale and the medial femoral cortex. They fuse together proximally to form the medial femoral neck. A stem placed centrally will abut against the calcar femorale with little or no space for cement. Clearing of the calcar will offer space for a cement layer, which will support the stem proximally on the posterior aspect. We compared two consecutive groups of Charnley low-friction arthroplasties, with and without clearing of the calcar. In 330 patients who had an arthroplasty without clearing the calcar, there were ten revisions for aseptic loosening of the stem and six other stems were considered ‘definitely loose’, giving a rate of failure of 4.8%. In 111 patients in whom the calcar was cleared there was only one revision for aseptic loosening and no stems were classed as ‘definitely loose’, giving a rate of failure of 0.9%. Survivorship analysis has again shown the need for long-term follow-up; the differences became clear after ten years but because of the relatively small numbers, statistical analysis is not yet applicable. We now clear the calcar femorale routinely and advocate optimal access to the medullary canal and insertion of the stem in the area of the piriform fossa


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1033 - 1044
1 Aug 2011
Periasamy K Watson WS Mohammed A Murray H Walker B Patil S Meek RMD

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation. Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry. We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 658 - 666
1 Jul 2002
Khaw FM Kirk LMG Morris RW Gregg PJ

We have carried out a long-term survival analysis of a prospective, randomised trail comparing cemented with cementless fixation of press-fit condylar primary total knee replacements. A consecutive series of 501 replacements received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. The patients were contacted at a mean follow-up of 7.4 years (2.7 to 13.0) to establish the rate of survival of the implant. The ten-year survival was compared using life-table and Cox’s proportional hazard analysis. No patient was lost to follow-up. The survival at ten years was 95.3% (95% CI 90.3 to 97.8) and 95.6% (95% CI 89.5 to 98.2) in the cemented and cementless groups, respectively. The hazard ratio for failure in cemented compared with cementless prostheses was 0.97 (95% CI 0.36 to 2.6). A comparison of the clinical outcome at ten years in 80 knees showed no difference between the two groups. The survival of the press-fit condylar total knee replacement at ten years is good irrespective of the method of fixation and brings into question the use of more expensive cementless implants


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 892 - 898
1 Nov 1996
Bulstra SK Geesink RGT Bakker D Bulstra TH Bouwmeester SJM van der Linden AJ

We have investigated the use of a conically-shaped cement plug made of Polyactive (PA), a biodegradable copolymer. The flexibility and hydrogel properties were thought to facilitate occlusion of the femoral canal even when it was oval or irregular in shape. The function of the plug was first compared with that of the Thackray polyethylene model in 16 artificial plastic femora. The maximum intramedullary pressure achieved during cementing was ten times higher with the biodegradable model. Migration or leakage of cement did not occur when the diameter of the femoral canal was equal to or smaller than the diameter of the plug. We also showed that the biodegradable properties of this implant were such that it did not require removal during revision. The new plug was tested in a pilot clinical trial. At two years only two out of 21 patients had evidence of migration or leakage of cement, probably due to a mismatch in the size of plug and femoral canal. There were no local changes in the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 982 - 986
1 Nov 1999
Ritter MA Zhou H Keating CM Keating EM Faris PM Meding JB Berend ME

We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a thin cement mantle in Gruen zone 5 was there a significant association with failure of the femoral component. There were 12 loose acetabular components (6.5%), nine (4.8%) of which were revised. When the initial radiograph after operation showed radiolucency in DeLee and Charnley zone 1, the incidence of acetabular loosening was 28.21%. If such radiolucency was not present, the incidence of acetabular loosening was only 0.69%. Our findings emphasise the importance of careful cementing


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 344 - 349
1 Apr 2004
McCombe P Williams SA

We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions, 115 hips were studied for differences in rates of wear and osteolysis. The mean clinical follow-up was eight years and the mean radiological follow-up, 6.5 years. The cementless cups wore at a mean rate of 0.15 mm per year and the cemented cups at 0.07 mm per year. This difference was significant (p < 0.0001). Our findings in this mid-term study suggest that cementless cups wear more than cemented cups


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1045 - 1050
1 Nov 1998
Donati D Biscaglia R

We have studied 35 patients with infected reconstructions after segmental resection for bone tumours. Two different regimes of treatment were employed both of which entailed debridement and the use of cement impregnated with antibiotic. In 25 patients gentamicin-PMMA beads were used and in ten an antibiotic-impregnated cement spacer. Better results were achieved with the second procedure in terms of cases healed, the number of operations, time of healing, time of recovery and the functional score. The use of vancomycin in the cement spacer gave better local control


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 460 - 464
1 Aug 1982
Bayston R Milner R

The release of gentamicin sulphate, sodium fusidate and diethanolamine fusidate from Palacos and CMW cements was studied using elution and serial plate transfer tests. Further tests were made to assay the drug remaining in the cement after antibacterial activity could no longer be detected by the above methods, to detect the sustained slow release of the residual drug, and to ascertain the mechanism of release. The results confirmed that the release of gentamicin sulphate could be detected for longer from Palacos cement than from CMW cement, but the opposite was true for sodium fusidate. Little difference was found in the case of diethanolamine fusidate. Comparison of elution and serial plate transfer tests, and of results of elution in buffers of different pH, demonstrated that the test method employed had a significant effect on the results, and the omission of details of methodology from some publications made comparison and evaluation of results difficult. Varying quantities of residual drug were found in cement from which antibacterial activity could no longer be demonstrated; further tests for sustained, slow release showed that the antibiotic did not remain fixed in the cement but was released at a rate too slow to be detected in the elution and serial plate transfer tests. It is concluded that antibiotics are released from the cement by a process of diffusion, but tests to determine the mechanism of diffusion were unhelpful. The theory of diffusion of drugs through solid matrices, and the clinical implications of the experimental findings, are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 971 - 979
1 Nov 1990
Anthony P Gie G Howie C Ling R

Four cases are described of localised endosteal bone lysis in the femur occurring in association with cemented femoral components that were not obviously 'loose' radiologically. In each, the area of lysis was shown at operation to be related directly to a region in which there was a local defect in the cement mantle surrounding the stem. Via the space between the stem and cement, such defects provide a route through which the contents of the joint cavity may reach the endosteal surface of the femur, subsequently leading to localised bone lysis, and later to frank loosening