Bone & Joint 360
Vol. 7, Issue 4 | Pages 33 - 36
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1025 - 1032
1 Aug 2018
Wang D Wang H Luo Z Meng W Pei F Li Q Zhou Z Zeng W

Aims

The aim of this study was to identify the most effective regimen of multiple doses of oral tranexamic acid (TXA) in achieving maximum reduction of blood loss in total knee arthroplasty (TKA).

Patients and Methods

In this randomized controlled trial, 200 patients were randomized to receive a single dose of 2.0 g of TXA orally two hours preoperatively (group A), a single dose of TXA followed by 1.0 g orally three hours postoperatively (group B), a single dose of TXA followed by 1.0 g three and nine hours postoperatively (group C), or a single dose of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively (group D). All patients followed a routine enhanced-recovery protocol. The primary outcome measure was the total blood loss. Secondary outcome measures were hidden blood loss (HBL), reduction in the level of haemoglobin, the rate of transfusion and adverse events.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1043 - 1053
1 Aug 2018
Scott CEH Turnbull GS Powell-Bowns MFR MacDonald DJ Breusch SJ

Aims

The aim of this study was to identify predictors of return to work (RTW) after revision lower limb arthroplasty in patients of working age in the United Kingdom.

Patients and Methods

We assessed 55 patients aged ≤ 65 years after revision total hip arthroplasty (THA). There were 43 women and 12 men with a mean age of 54 years (23 to 65). We also reviewed 30 patients after revision total knee arthroplasty (TKA). There were 14 women and 16 men with a mean age of 58 years (48 to 64). Preoperatively, age, gender, body mass index, social deprivation, mode of failure, length of primary implant survival, work status and nature, activity level (University of California, Los Angeles (UCLA) score), and Oxford Hip and Knee Scores were recorded. Postoperatively, RTW status, Oxford Hip and Knee Scores, EuroQol-5D (EQ-5D), UCLA score, and Work, Osteoarthritis and Joint-Replacement Questionnaire (WORQ) scores were obtained. Univariate and multivariate analysis was performed.


Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


Bone & Joint Research
Vol. 7, Issue 5 | Pages 351 - 356
1 May 2018
Yeoman TFM Clement ND Macdonald D Moran M

Objectives

The primary aim of this study was to assess the reproducibility of the recalled preoperative Oxford Hip Score (OHS) and Oxford Knee Score (OKS) one year following arthroplasty for a cohort of patients. The secondary aim was to assess the reliability of a patient’s recollection of their own preoperative OHS and OKS one year following surgery.

Methods

A total of 335 patients (mean age 72.5; 22 to 92; 53.7% female) undergoing total hip arthroplasty (n = 178) and total knee arthroplasty (n = 157) were prospectively assessed. Patients undergoing hip and knee arthroplasty completed an OHS or OKS, respectively, preoperatively and were asked to recall their preoperative condition while completing the same score one year after surgery.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 15 - 18
1 Apr 2018


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 62 - 67
1 Jan 2018
Bedard NA DeMik DE Dowdle SB Callaghan JJ

Aims

The purpose of this study was to evaluate trends in opioid use after unicompartmental knee arthroplasty (UKA), to identify predictors of prolonged use and to compare the rates of opioid use after UKA, total knee arthroplasty (TKA) and total hip arthroplasty (THA).

Materials and Methods

We identified 4205 patients who had undergone UKA between 2007 and 2015 from the Humana Inc. administrative claims database. Post-operative opioid use for one year post-operatively was assessed using the rates of monthly repeat prescription. These were then compared between patients with and without a specific variable of interest and with those of patients who had undergone TKA and THA.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 455 - 460
1 Apr 2018
Mumith A Thomas M Shah Z Coathup M Blunn G

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research.

This review describes the current position in the use of additive manufacturing in orthopaedic surgery.

Cite this article: Bone Joint J 2018;100-B:455-60.


Bone & Joint Research
Vol. 7, Issue 3 | Pages 213 - 222
1 Mar 2018
Tang X Teng S Petri M Krettek C Liu C Jagodzinski M

Objectives

The aims of this study were to determine whether the administration of anti-inflammatory and antifibrotic agents affect the proliferation, viability, and expression of markers involved in the fibrotic development of the fibroblasts obtained from arthrofibrotic tissue in vitro, and to evaluate the effect of the agents on arthrofibrosis prevention in vivo.

Methods

Dexamethasone, diclofenac, and decorin, in different concentrations, were employed to treat fibroblasts from arthrofibrotic tissue (AFib). Cell proliferation was measured by DNA quantitation, and viability was analyzed by Live/Dead staining. The levels of procollagen type I N-terminal propeptide (PINP) and procollagen type III N-terminal propeptide (PIIINP) were evaluated with enzyme-linked immunosorbent assay (ELISA) kits. In addition, the expressions of fibrotic markers were detected by real-time polymerase chain reaction (PCR). Fibroblasts isolated from healthy tissue (Fib) served as control. Further, a rabbit model of joint contracture was used to evaluate the antifibrotic effect of the three different agents.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1467 - 1476
1 Nov 2017
van Hamersveld KT Marang-van de Mheen PJ Tsonaka R Valstar† ER Toksvig-Larsen S

Aims

The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs.

Patients and Methods

Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1319 - 1328
1 Oct 2017
Shelton TJ Nedopil AJ Howell SM Hull ML

Aims

The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces.

Patients and Methods

The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria.


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 68 - 75
1 Jan 2018
Goel R Fleischman AN Tan T Sterbis E Huang R Higuera C Parvizi J Rothman RH

Aims

The aims of this study were to compare the efficacy of two agents, aspirin and warfarin, for the prevention of venous thromboembolism (VTE) after simultaneous bilateral total knee arthroplasty (SBTKA), and to elucidate the risk of VTE conferred by this procedure compared with unilateral TKA (UTKA).

Patients and Methods

A retrospective, multi-institutional study was conducted on 18 951 patients, 3685 who underwent SBTKA and 15 266 who underwent UTKA, using aspirin or warfarin as VTE prophylaxis. Each patient was assigned an individualised baseline VTE risk score based on a system using the Nationwide Inpatient Sample. Symptomatic VTE, including pulmonary embolism (PE) and deep vein thrombosis (DVT), were identified in the first 90 days post-operatively. Statistical analyses were performed with logistic regression accounting for baseline VTE risk.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1596 - 1602
1 Dec 2017
Dunbar MJ Laende EK Collopy D Richardson CG

Aims

Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation.

Patients and Methods

A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1431 - 1434
1 Nov 2017
Jacofsky DJ

Modern healthcare contracting is shifting the responsibility for improving quality, enhancing community health and controlling the total cost of care for patient populations from payers to providers. Population-based contracting involves capitated risk taken across an entire population, such that any included services within the contract are paid for by the risk-bearing entity throughout the term of the agreement. Under such contracts, a risk-bearing entity, which may be a provider group, a hospital or another payer, administers the contract and assumes risk for contractually defined services. These contracts can be structured in various ways, from professional fee capitation to full global per member per month diagnosis-based risk. The entity contracting with the payer must have downstream network contracts to provide the care and facilities that it has agreed to provide. Population health is a very powerful model to reduce waste and costs. It requires a deep understanding of the nuances of such contracting and the appropriate infrastructure to manage both networks and risk.

Cite this article: Bone Joint J 2017;99-B:1431–4.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 887 - 893
1 Jul 2017
Ogawa H Matsumoto K Akiyama H

Aims

We aimed to investigate factors related to the technique of medial opening wedge high tibial osteotomy which might predispose to the development of a lateral hinge fracture.

Patients and Methods

A total of 71 patients with 82 osteotomies were included in the study. Their mean age was 62.9 years (37 to 80). The classification of the type of osteotomy was based on whether it extended beyond the fibular head. The level of the osteotomy was classified according to the height of its endpoint.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1482 - 1489
1 Nov 2017
Jacobs AME Bénard M Meis JF van Hellemondt G Goosen JHM

Aims

Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases.

Patients and Methods

A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1298 - 1303
1 Oct 2017
Schouten R Malone AA Frampton CM Tiffen C Hooper G

Aims

The primary aim of this independent prospective randomised trial was to compare serum metal ion levels for ceramic-on-metal (CoM) and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty (THA). Our one-year results demonstrated elevation in metal ion levels above baseline with no significant difference between the CoM and MoM groups. This paper reviews the five-year data.

Patients and Methods

The implants used in each patient differed only in respect to the type of femoral head (ceramic or metal). At five-year follow-up of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available for comparison.