Advertisement for orthosearch.org.uk
Results 181 - 200 of 2239
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 291 - 298
1 May 1983
Lamb D Chan K

A review is presented of 41 patients with traumatic tetraplegia on whom reconstructive surgery of the upper limb was carried out. Twelve patients were followed up for more than 10 years after operation and the average period overall was seven and a half years. Tendon transfers were made with the aim of providing extension of the elbow or restoring a useful grasp or a combination of both. The assessment was carried out on four main aspects: the function of the elbow, the function of the hand, the ability to carry out the activities of daily living and the effect of the surgical reconstruction on the personal and social achievement of the patient


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 36 - 42
1 Jan 1997
Hsu RW Wood MB Sim FH Chao EYS

We have reviewed 30 patients at a mean of 36 months after free vascularised fibular transfer to reconstruct massive skeletal defects after resection of primary bone tumours. There were 23 malignant and 7 benign neoplasms, half in the lower limb and half in the upper. Arthrodesis was performed in 15 and intercalary bone replacement in 15. The mean fibular graft length was 189 mm. Union was achieved in 27 (90%) at an average of 7.6 months, and the 3-year survival was 89%. There was a high complication rate (50%), but most resolved without greatly influencing the final outcome. There was local recurrence in two (6.7%), but 16 of the 24 assessed patients (67%) had satisfactory functional results. This is a reasonably effective means of reconstruction for limb salvage after resection of tumours


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 230 - 238
1 Feb 2013
Giannoudis PV Kanakaris NK Delli Sante E Morell DJ Stengel D Prevezas N

Over a five-year period, adult patients with marginal impaction of acetabular fractures were identified from a registry of patients who underwent acetabular reconstruction in two tertiary referral centres. Fractures were classified according to the system of Judet and Letournel. A topographic classification to describe the extent of articular impaction was used, dividing the joint surface into superior, middle and inferior thirds. Demographic information, hospitalisation and surgery-related complications, functional (EuroQol 5-D) and radiological outcome according to Matta’s criteria were recorded and analysed. In all, 60 patients (57 men, three women) with a mean age of 41 years (18 to 72) were available at a mean follow-up of 48 months (24 to 206). The quality of the reduction was ‘anatomical’ in 44 hips (73.3%) and ‘imperfect’ in 16 (26.7%). The originally achieved anatomical reduction was lost in12 patients (25.8%). Radiologically, 33 hips (55%) were graded as ‘excellent’, 11 (18.3%) as ‘good’, one (1.7%) as ‘fair’ and 15 (25%) as ‘poor’. A total of 11 further operations were required in 11 cases, of which six were total hip replacements.

Univariate linear regression analysis of the functional outcome showed that factors associated with worse pain were increasing age and an inferior location of the impaction. Elevation of the articular impaction leads to joint preservation with satisfactory overall medium-term functional results, but secondary collapse is likely to occur in some patients.

Cite this article: Bone Joint J 2013;95-B:230–8.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 660 - 663
1 May 2013
Ghosh S Singh VK Jeyaseelan L Sinisi M Fox M

In adults with brachial plexus injuries, lack of active external rotation at the shoulder is one of the most common residual deficits, significantly compromising upper limb function. There is a paucity of evidence to address this complex issue. We present our experience of isolated latissimus dorsi (LD) muscle transfer to achieve active external rotation. This is a retrospective review of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus dorsi muscle transfer to restore external rotation of the shoulder between 1997 and 2010. All patients were male with a mean age of 34 years (21 to 57). All the patients underwent isolated LD muscle transfer using a standard technique to correct external rotational deficit. Outcome was assessed for improvement in active external rotation, arc of movement, muscle strength and return to work. The mean improvement in active external rotation from neutral was 24° (10° to 50°). The mean increase in arc of rotation was 52° (38° to 55°). Mean power of the external rotators was 3.5 Medical Research Council (MRC) grades (2 to 5).

A total of 21 patients (88%) were back in work by the time of last follow up. Of these, 13 had returned to their pre-injury occupation. Isolated latissimus dorsi muscle transfer provides a simple and reliable method of restoring useful active external rotation in adults with brachial plexus injuries with internal rotational deformity.

Cite this article: Bone Joint J 2013;95-B:660–3.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 682 - 687
1 May 2006
Kanazawa T Soejima T Murakami H Inoue T Katouda M Nagata K

We studied bone-tendon healing using immunohistochemical methods in a rabbit model. Reconstruction of the anterior cruciate ligament was undertaken using semitendinosus tendon in 20 rabbits. Immunohistochemical evaluations were performed at one, two, four and eight weeks after the operation. The expression of CD31, RAM-11, VEGF, b-FGF, S-100 protein and collagen I, II and III in the bone-tendon interface was very similar to that in the endochondral ossification. Some of the type-III collagen in the outer layer of the graft, which was deposited at a very early phase after the operation, was believed to have matured into Sharpey-like fibres. However, remodelling of the tendon grafted into the bone tunnel was significantly delayed when compared with this ossification process. To promote healing, we believe that it is necessary to accelerate remodelling of the tendon, simultaneously with the augmentation of the ossification


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 610 - 613
1 Jul 1994
Hoy G Henderson I

We reviewed 32 ankles in 30 patients at an average of five years after a Watson-Jones tenodesis. All but one patient had had ankle pain before operation and 19 had had clicking, catching, or locking of the ankle. Eleven of these had an ankle arthrotomy at the time of ligament reconstruction for intraarticular pathology. At review seven of 23 ankles had a significant decrease in ankle motion, and five in subtalar motion, but only two were unstable on examination. Twenty-one ankles, however, caused some pain on activity and nine were tender on palpation. These findings indicate intra-articular degeneration or injury rather than simple instability. Radiographs of 16 ankles showed good varus and anterior-drawer stability. Seven had talocrural osteoarthritis, but only four showed grade-1 subtalar osteoarthritis. We found no correlation between follow-up time and long-term results. The Watson-Jones tenodesis provides good rotational and lateral ankle instability and does not appear to lead to subtalar degeneration


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1069 - 1074
1 Aug 2013
Rao BM Kamal TT Vafaye J Moss M

We report the results of revision total knee replacement (TKR) in 26 patients with major metaphyseal osteolytic defects using 29 trabecular metal cones in conjunction with a rotating hinged total knee prosthesis. The osteolytic defects were types II and III (A or B) according to the Anderson Orthopaedic Research Institute (AORI) classification. The mean age of the patients was 72 years (62 to 84) and there were 15 men and 11 women. In this series patients had undergone a mean of 2.34 previous total knee arthroplasties. The main objective was to restore anatomy along with stability and function of the knee joint to allow immediate full weight-bearing and active knee movement. Outcomes were measured using Knee Society scores, Oxford knee scores, range of movement of the knee and serial radiographs. Patients were followed for a mean of 36 months (24 to 49). The mean Oxford knee clinical scores improved from 12.83 (10 to 15) to 35.20 (32 to 38) (p < 0.001) and mean American Knee Society scores improved from 33.24 (13 to 36) to 81.12 (78 to 86) (p < 0.001). No radiolucent lines suggestive of loosening were seen around the trabecular metal cones, and by one year all the radiographs showed good osteo-integration. There was no evidence of any collapse or implant migration. Our early results confirm the findings of others that trabecular metal cones offer a useful way of managing severe bone loss in revision TKR.

Cite this article: Bone Joint J 2013;95-B:1069–74.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 119 - 122
1 Jan 1993
Karachalios T Atkins R Sarangi P Crichlow T Solomon L

We describe the use of intramedullary reconstruction nails in the treatment of 14 patients with pathological subtrochanteric fractures and coexisting metastases in the femoral shaft. After nailing, all patients were free from pain and regained mobility. They were followed up clinically and radiologically until death from the primary disease. There were no mechanical failures even when a less than ideal reduction had been achieved


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 698 - 703
1 May 2012
Soni A Tzafetta K Knight S Giannoudis PV

Controversy continues to surround the management of patients with an open fracture of the lower limb and an associated vascular injury (Gustilo type IIIC). This study reports our 15-year experience with these fractures and their outcome in 18 patients (15 male and three female). Their mean age was 30.7 years (8 to 54) and mean Mangled Extremity Severity Score (MESS) at presentation was 6.9 (3 to 10). A total of 15 lower limbs were salvaged and three underwent amputation (two immediate and one delayed). Four patients underwent stabilisation of the fracture by external fixation and 12 with an internal device. A total of 11 patients had damage to multiple arteries and eight had a vein graft. Wound cover was achieved with a pedicled flap in three and a free flap in six. Seven patients developed a wound infection and four developed nonunion requiring further surgery. At a mean follow-up of five years (4.1 to 6.6) the mean visual analogue scale for pain was 64 (10 to 90). Depression and anxiety were common. Activities were limited mainly because of pain, and the MESS was a valid predictor of the functional outcome. Distal tibial fractures had an increased rate of nonunion when associated with posterior tibial artery damage, and seven patients (39%) were not able to return to their previous occupation.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims

Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs.

Methods

A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10).


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 622 - 624
1 Aug 1988
Amirault J Cameron J MacIntosh D Marks P

The lateral substitution reconstruction operation described by MacIntosh has been evaluated in 27 patients with chronic anterior cruciate ligament deficiency of the knee. The results, at an average of 11.3 years after operation, have been assessed by a scoring system which allocates a maximum of 25 points each for function and for clinical evaluation. Emphasis was placed on subjective giving way and objective evidence of a positive anterior drawer sign and a positive lateral pivot shift test. A score of 46 to 50 was classified as excellent, 41 to 46 as fair, and less than 41 was a poor result: 52% scored excellent, 26% fair and 22% were poor. Most of those with poor results had had evidence of osteoarthritis at the time of operation. Despite the recorded scores, no less than 75% of the patients at long-term follow-up were subjectively improved, and able to maintain an active life style


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1592 - 1596
1 Dec 2011
Babis GC Sakellariou VI Chatziantoniou AN Soucacos PN Megas P

We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting.

At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision.

We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1277 - 1281
1 Sep 2012
Puri A Gulia A

Rarely, the extent of a malignant bone tumour may necessitate resection of the complete humerus to achieve adequate oncological clearance. We present our experience with reconstruction in such cases using a total humeral endoprosthesis (THER) in 20 patients (12 male and eight female) with a mean age of 22 years (6 to 59). We assessed the complications, the oncological and functional outcomes and implant survival. Surgery was performed between June 2001 and October 2009. The diagnosis included osteosarcoma in nine, Ewing’s sarcoma in eight and chondrosarcoma in three. One patient was lost to follow-up. The mean follow-up was 41 months (10 to 120) for all patients and 56 months (25 to 120) in survivors. There were five local recurrences (26.3%) and 11 patients were alive at time of last follow-up, with overall survival for all patients being 52% (95% confidence interval (CI) 23.8 to 74) at five years. The mean Musculoskeletal Tumor Society score for the survivors was 22 (73%; 16 to 23). The implant survival was 95% (95% CI 69.5 to 99.3) at five years.

The use of a THER in the treatment of malignant tumours of bone is oncologically safe; it gives consistent and predictable results with low rates of complication.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 623 - 628
1 May 2013
Maletis GB Inacio MCS Desmond JL Funahashi TT

We examined the association of graft type with the risk of early revision of primary anterior cruciate ligament reconstruction (ACLR) in a community-based sample. A retrospective analysis of a cohort of 9817 ACLRs recorded in an ACLR Registry was performed. Patients were included if they underwent primary ACLR with bone–patellar tendon–bone autograft, hamstring tendon autograft or allograft tissue. Aseptic failure was the main endpoint of the study. After adjusting for age, gender, ethnicity, and body mass index, allografts had a 3.02 times (95% confidence interval (CI) 1.93 to 4.72) higher risk of aseptic revision than bone–patellar tendon–bone autografts (p < 0.001). Hamstring tendon autografts had a 1.82 times (95% CI 1.10 to 3.00) higher risk of revision compared with bone–patellar tendon–bone autografts (p = 0.019). For each year increase in age, the risk of revision decreased by 7% (95% CI 5 to 9). In gender-specific analyses a 2.26 times (95% CI 1.15 to 4.44) increased risk of hamstring tendon autograft revision in females was observed compared with bone–patellar tendon–bone autograft. We conclude that allograft tissue, hamstring tendon autografts, and younger age may all increase the risk of early revision surgery after ACLR.

Cite this article: Bone Joint J 2013;95-B:623–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 579 - 582
1 May 2000
Nakata K Shino K Horibe S Natsu-ume T Mae T Ochi T

We have described a method of anatomical reconstruction of the lateral ligaments of the ankles with instability using allogeneic fascia lata dried with solvents and sterilised with gamma irradiation. Twenty ankles of 20 patients were assessed objectively and subjectively after a mean follow-up of 4.2 years (3.1 to 10). The result was excellent in 12 (60%), good in seven (35%) and fair in one (5%); none had a poor result. Stress radiography showed that the angle of talar tilt improved from 12.3 ± 4.2° (mean ±. sd. ) to 5.9 ± 3.0° and that the anterior drawer distance decreased from 9.2 ± 3.9 mm to 4.4 ± 2.5 mm. Neither infection nor limitation of movement occurred after operation. Fascia lata allografts provide a good alternative to autogenous grafts such as the peroneus brevis tendon


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 608 - 615
1 May 2016
Kuršumović K Charalambous CP

Aims

To examine the rates of hamstring graft salvage with arthroscopic debridement of infected anterior cruciate ligament (ACL) reconstruction as reported in the literature and discuss functional outcomes.

Materials and Methods

A search was performed without language restriction on PubMed, EMBASE, Ovid, CINAHL and Cochrane Register of Controlled Trials (CENTRAL) databases from their inception to April 2015. We identified 147 infected hamstring grafts across 16 included studies. Meta-analysis was performed using a random-effects model to estimate the overall graft salvage rate, incorporating two different definitions of graft salvage.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 47 - 52
1 Jan 1991
Zarnett R Velazquez R Salter R

Our purpose was to determine whether continuous passive motion enhanced the quality of knee ligament reconstruction using carbon fibre. In 46 rabbits the medial collateral ligaments were excised and replaced with carbon fibre prostheses. The animals were treated postoperatively by either continuous passive motion, cast immobilisation or cage activity, termed intermittent active motion. At six weeks, the ligaments were compared histologically and biomechanically with normal (control) medial collateral ligaments and with sham-operated controls. The ligaments treated with continuous passive motion were superior to those in the other two treatment groups. There were no ligament failures in any of the groups. This study suggests that continuous passive motion, initiated immediately postoperatively, enhances the biomechanical properties of carbon fibre ligament replacement of the medial collateral ligament while preventing the harmful effects of joint immobilisation


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1020 - 1026
1 Aug 2016
Śmigielski R Zdanowicz U Drwięga M Ciszek B Williams A

Anterior cruciate ligament (ACL) reconstruction is commonly performed and has been for many years. Despite this, the technical details related to ACL anatomy, such as tunnel placement, are still a topic for debate. In this paper, we introduce the flat ribbon concept of the anatomy of the ACL, and its relevance to clinical practice.

Cite this article: Bone Joint J 2016;98-B:1020–6.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 25 - 30
1 Jan 2017
Waddell BS Della Valle AG

This review summarises the technique of impaction grafting with mesh augmentation for the treatment of uncontained acetabular defects in revision hip arthroplasty.

The ideal acetabular revision should restore bone stock, use a small socket in the near-anatomic position, and provide durable fixation. Impaction bone grafting, which has been in use for over 40 years, offers the ability to achieve these goals in uncontained defects. The precepts of modern, revision impaction grafting are that the segmental or cavitary defects must be supported with a mesh; the contained cavity is filled with vigorously impacted morselised fresh-frozen allograft; and finally, acrylic cement is used to stabilise the graft and provide rigid, long-lasting fixation of the revised acetabular component.

Favourable results have been published with this technique. While having its limitations, it is a viable option to address large acetabular defects in revision arthroplasty.

Cite this article: Bone Joint J 2017;99-B(1 Supple A):25–30.