Between 1982 and 1997, 403 consecutive patients (522 elbows) with rheumatoid arthritis underwent Souter-Strathclyde total elbow replacement. By the end of 2007, there had been 66 revisions for aseptic loosening in 60 patients. The mean time of follow-up was 10.6 years (0 to 25) The survival rates at five-, ten, 15 and 19 years were 96% (95%, confidence interval (CI) 95 to 98), 89% (95% CI 86 to 92), 83% (95% CI 78 to 87), and 77% (95% CI 69 to 85), respectively. The small and medium-sized short-stemmed primary humeral components had a 5.6-fold and 3.6-fold risk of revision for aseptic loosening respectively, compared to the medium-sized long-stemmed component. The small and medium-sized all-polyethylene ulnar components had respectively a 28.2-fold and 8.4-fold risk of revision for aseptic loosening, compared to the metal-backed ulnar components. The use of retentive ulnar components was not associated with an increased risk of aseptic loosening compared to non-retentive implants.
We reviewed 75 patients (57 men and 18 women), who had undergone tension-band laminoplasty for cervical spondylotic myelopathy (42 patients) or compression myelopathy due to ossification of the posterior longitudinal ligament (33 patients) and had been followed for more than ten years. Clinical and functional results were estimated using the Japanese Orthopaedic Association score. The rate of recovery and the level of postoperative axial neck pain were also recorded. The pre- and post-operative alignment of the cervical spine (Ishihara curve index indicating lordosis of the cervical spine) and the range of movement (ROM) of the cervical spine were also measured. The mean rate of recovery of the Japanese Orthopaedic Association score at final follow-up was 52.1% (
We investigated the excess mortality risk associated with fractures of the hip. Data related to 29 134 patients who underwent surgery following a fracture of the hip were obtained from the Scottish Hip Fracture Audit database. Fractures due to primary or metastatic malignancy were excluded. An independent database (General Register Office (Scotland)) was used to validate dates of death. The observed deaths per 100 000 of the population were then calculated for each group (gender, age and fracture type) at various time intervals up to eight years. A second database (Interim Life Tables for Scotland, Scottish Government) was then used to create standardised mortality ratios. Analysis showed that mortality in patients aged >
85 years with a fracture of the hip tended to return to the level of the background population between two and five years after the fracture. In those patients aged <
85 years excess mortality associated with hip fracture persisted beyond eight years. Extracapsular hip fractures and male gender also conferred increased risk.
A total of 138 revision hip arthroplasties in 134 patients, all operated upon by one surgeon, were followed for an average of 7.4 years. The overall results were reasonable, with good to excellent Mayo hip scores in 62% and little or no pain in 86%. These results were independent of body weight, age, primary diagnosis and type of arthroplasty used. The incidence of radiological loosening was alarming, though comparable to that found in other series. Our findings indicate that it may be wise to replace both components even when, after careful assessment before and during operation, one of them seems to be securely fixed.
The results of 62 ankle arthrodeses, mostly performed for osteoarthritis, have been reviewed; of these, 39 were examined clinically and radiographically after an average follow-up period of seven years. Compression arthrodesis was associated with the highest incidence of complications, and an anterior sliding graft gave the most satisfactory results. Very few patients required modification of their footwear; most could walk independently with a slight limp and were able to return to their pre-operative work. However, after operation, the ability to run and to participate in vigorous sporting activities was limited. Complications included wound infection, non-union, and some change in midtarsal mobility, but excellent pain relief was reported by all patients.
Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p <
0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.
We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years ( The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial
To report the five-year results of a randomised controlled trial
examining the effectiveness of arthroscopic acromioplasty in the
treatment of stage II shoulder impingement syndrome. A total of 140 patients were randomly divided into two groups:
1) supervised exercise programme (n = 70, exercise group); and 2)
arthroscopic acromioplasty followed by a similar exercise programme
(n = 70, combined treatment group).Objectives
Methods
Claims for personal injury after whiplash injury cost the economy of the United Kingdom more than ÂŁ3 billion per year, yet only very few patients have radiologically demonstrable pathology. Those sustaining fractures of the cervical spine have been subjected to greater force and may reasonably be expected to have worse symptoms than those with whiplash injuries. Using the neck disability index as the outcome measure, we compared pain and functional disability in four groups of patients who had suffered injury to the cervical spine. After a mean follow-up of 3.5 years, patients who had sustained fractures of the cervical spine had significantly lower levels of pain and disability than those who had received whiplash injuries and were pursuing compensation (p <
0.01), but had similar levels to those whiplash sufferers who had settled litigation or had never sought compensation. Functional recovery after neck injury was unrelated to the physical insult. The increased morbidity in whiplash patients is likely to be psychological and is associated with litigation.
Twenty-two knees with osteochondritis dissecans diagnosed before skeletal maturity were followed prospectively into middle age: 32% had radiographic evidence of moderate or severe osteoarthritis at an average follow-up of 33.6 years; only half had a good or excellent functional result. We found that osteoarthritis was more likely to occur if the defect was large or affected the lateral femoral condyle.
Between 1965 and 1973 a total of 808 McKee-Farrar metal-on-metal cemented total hip arthroplasties were performed in the Norfolk and Norwich Hospital. Of these, 230 surviving arthroplasties have been reviewed at average follow-up of 13.9 years. There were good or excellent results in 49% of the arthroplasties as judged by the Harris hip score with 78% of these having little or no pain. A comprehensive radiographic analysis was undertaken and a survivorship study of 81% of the total number of prostheses is presented.
Seventy-one Geomedic total knee replacements were reviewed retrospectively at a maximum of eight and a half years. The prosthesis was found to be successful in its primary aim of relieving pain. However, there was an overall failure rate of 18.3%. Analysis of the results by an actuarial method allowed comparison with other prostheses. The factors involved in failure are discussed.
Between 1969 and 1971 20 prototypes of the Stanmore total knee prosthesis were used to replace severely arthritic knees in 18 patients. Seven patients died before the final follow-up and one had to have her leg amputated because of deep infection; in none of these patients had the prosthesis become loose. Ten patients (11 knees) were reviewed at least 10 years after operation. There was no significant clinical deterioration in 7 of these 11 surviving knees when the results at one year were compared with those at 10 years.
Nine patients have been reviewed at an average period of 22 years after a Watson-Jones tenodesis performed for chronic instability of the ankle. Only three patients had complete relief of symptoms. Two favourable early results deteriorated 7 and 10 years after operation. Radiographic examination revealed full correction of both anterior and lateral instability of the talus in only two cases. Talar tilt was controlled more successfully than increased anterior drawer movement. Long-standing instability was associated with the formation of marginal exostoses, the severity of which appeared proportional to the degree of instability.
One hundred and three sequential Stanmore knee replacements were reviewed retrospectively on two occasions with a maximal follow-up period of nine years three months. This knee prosthesis, which is hinged, was successful in alleviating pain, stabilising an unstable knee and modestly increasing the arc of flexion. Walking capacity was increased and flexion contractures were reduced. There were seven cases of infection and four of fracture around the prosthesis. All these proved difficult to treat and two knees with both fracture and infection needed amputation. Eight knees were revised for aseptic loosening and a further 14 were found to have radiological signs of loosening. The results have been analysed by the methods advocated by Tew and Waugh and give a cumulative success rate of 80 per cent at seven years, provided success is judged solely by whether the prosthesis is still in situ. The role of the Stanmore knee as a primary arthroplasty is discussed.
Shelf arthroplasty is briefly reviewed in historical perspective and the results in 45 hips (39 patients) which had undergone this procedure at the Royal Children's Hospital are presented. The majority of these patients were adolescents who had previously been treated for congenital dislocation or subluxation of the hip. The indications for operation and the operative technique are discussed. Clinical examination was carried out upon 33 of the 39 patients at an average of 11 years after operation. The results suggested that where pain had been an indication for operation almost 80 percent of the hips remained relatively free of symptoms at the time of follow-up and in those patients where acetabular dysplasia had been an indication, the coverage remained good and pain had not appeared. It is concluded that the shelf operation is useful for dealing with both pain and dysplasia in the adolescent.
1. Thirty-eight patients with sixty-two forefoot arthroplasties have been followed up from two to thirteen years after the operation. Eleven were free of pain, thirty-eight had some pain but were improved, and the rest were worse. 2. Patients over the age of fifty or with rheumatoid arthritis did best. 3. Kirschner wire fixation of the great toe often caused late painful stiffness of the metatarsophalangeal joint. 4. Previous interphalangeal fusion of a lesser toe was often the cause of metatarso-phalangeal dislocation of that toe and callous formation. 5. Arthrodesis of the metatarso-phalangeal joint of the great toe gave a high proportion of painless feet, apparently because it prevented both painful stiffness at that joint and dislocation of the same joint of the lesser toes.
The purpose of this study was to evaluate the
long-term functional and radiological outcomes of arthroscopic removal
of unstable osteochondral lesions with subchondral drilling in the
lateral femoral condyle. We reviewed the outcome of 23 patients
(28 knees) with stage III or IV osteochondritis dissecans lesions
of the lateral femoral condyle at a mean follow-up of 14 years (10
to 19). The functional clinical outcomes were assessed using the Lysholm
score, which improved from a mean of 38.1 ( We found radiological evidence of degenerative changes in the
third or fourth decade of life at a mean of 14 years after arthroscopic
excision of the loose body and subchondral drilling for an unstable
osteochondral lesion of the lateral femoral condyle. Clinical and
functional results were more satisfactory.
We identified a series of 128 patients who had unilateral open reconstruction of the anterior cruciate ligament (ACL) by a single surgeon between 1993 and 2000. In all, 79 patients were reviewed clinically and radiologically eight to 15 years after surgery. Assessment included measurement of the Lysholm and Tegner scores, the ACL quality-of-life score and the Short Form-12 score, as well as the International Knee Documentation Committee clinical assessment, measurement of laxity by the KT-1000 arthrometer, a single-leg hop test and standardised radiography of both knees using the uninjured knee as a control. Of the injured knees, 46 (57%) had definite radiological evidence of osteoarthritis (Kellgren-Lawrence grade 2 or 3), with a mean difference between the injured and non-injured knees of 1.2 grades. The median ACL quality-of-life score was 80 (interquartile range (IQR) 60 to 90), the Lysholm score 84 (IQR 74 to 95), the Short Form-12 physical component score 54 (IQR 49 to 56) and the mean Hop Index 0.94 (0.52 to 1.52). In total 58 patients were graded as normal, 20 as nearly normal and one as abnormal on the KT-1000 assessment and pivot-shift testing. Taking the worst-case scenario of assuming all non-attenders (n = 48), two septic failures and one identified unstable knee found at review to be failures, the failure rate was 40%. Only two of the patients reviewed stated that they would not have similar surgery again. Open reconstruction of the ACL gives good, durable functional results, but with a high rate of radiologically evident osteoarthritis.