Any operation induces an elevation in the level of serum C-reactive protein (CRP). After hip and
Effective analgesia after total knee arthroplasty (TKA) improves
patient satisfaction, mobility and expedites discharge. This study
assessed whether continuous femoral nerve infusion (CFNI) was superior
to a single-shot femoral nerve block in primary TKA surgery completed
under subarachnoid blockade including morphine. We performed an adequately powered, prospective, randomised,
placebo-controlled trial comparing CFNI of 0.125% bupivacaine Objectives
Methods
The primary aim was to assess the patient-perceived effect of restrictions imposed due to COVID-19 on rehabilitation following total hip arthroplasty (THA) and total knee arthroplasty (TKA). Secondary aims were to assess perceived restrictions, influence on mental health, and functional outcome compared to patients undergoing surgery without restriction. During February and March 2020, 105 patients underwent THA (n = 48) or TKA (n = 57) and completed preoperative and six-month postoperative assessments. A cohort of 415 patients undergoing surgery in 2019 were used as the control. Patient demographic data, BMI, comorbidities, Oxford Hip Score (OHS) or Knee Score (OKS), and EuroQoL five-domain (EQ-5D) score were collected preoperatively and at six months postoperatively. At six months postoperatively, the 2020 patients were also asked to complete a questionnaire relating to the effect of the social restrictions on their outcome and their mental health.Aims
Methods
Wear of polyethylene inserts plays an important role in failure
of total knee replacement and can be monitored Before revision, the minimum joint space width values and their
locations on the insert were measured in 15 fully weight-bearing
radiographs. These measurements were compared with the actual minimum
thickness values and locations of the retrieved tibial inserts after
revision. Introduction
Method
We made a prospective study of the incidence of fatal pulmonary embolism in patients after total knee replacement with no prophylactic anticoagulation. There were 499 consecutive patients having 527
We report the five- to-ten year results of Anderson Orthopaedic Research Institute type-2 bone defects treated with modular metal augments in revision knee surgery. A total of 102 revision
We have previously reported the short-term radiological
results of a randomised controlled trial comparing kinematically
aligned total knee replacement (TKR) and mechanically aligned TKR,
along with early pain and function scores. In this study we report
the two-year clinical results from this trial. A total of 88 patients
(88 knees) were randomly allocated to undergo either kinematically
aligned TKR using patient-specific guides, or mechanically aligned
TKR using conventional instruments. They were analysed on an intention-to-treat
basis. The patients and the clinical evaluator were blinded to the
method of alignment. At a minimum of two years, all outcomes were better for the kinematically
aligned group, as determined by the mean Oxford knee score (40 (15
to 48) In this study, the use of a kinematic alignment technique performed
with patient-specific guides provided better pain relief and restored
better function and range of movement than the mechanical alignment
technique performed with conventional instruments. Cite this article:
We conducted a multicentre cohort study of 228 patients with osteoarthritis followed up after total hip or
We studied the changes in plasma viscosity and C-reactive protein to establish normal values after total hip or
Fungal prosthetic joint infections (PJIs) are rare and account for about 1% of total PJIs. Our aim was to present clinical and microbiological results in treating these patients with a two-stage approach and antifungal spacers. We retrospectively reviewed our institutional database and identified 26 patients with positive fungal cultures and positive Musculoskeletal Infection Society (MSIS) criteria for PJI who were treated between 2009 and 2017. We identified 18 patients with total hip arthroplasty (THA) and eight patients with total knee arthroplasty (TKA). The surgical and antifungal treatment, clinical and demographic patient data, complications, relapses, and survival were recorded and analyzed.Aims
Patients and Methods
This cohort study investigated the influence
of psychological factors, including perception of illness, anxiety
and depression on recovery and functional outcome after total knee
replacement surgery. A total of 100 patients (55 male; 45 female) with a mean age
of 71 (42 to 92) who underwent a primary total knee replacement
for osteoarthritis were recruited into this study. In all 97 participants
completed the six week and 87 the one year follow-up questionnaires. Pre-operatively patients completed the revised Illness Perception
Questionnaire, Hospital Anxiety and Depression Scale and Recovery
Locus of Control Scale. Function was assessed pre-operatively, at
six weeks and one year using Oxford Knee Score (OKS) and the goniometer-measured
range of movement (ROM). The results showed that pre-operative function had the biggest
impact on post-operative outcome for ROM and OKS. In addition questionnaire
variables and depression had an impact on the OKS at six weeks.
Depression and anxiety were also associated with a higher (worse)
knee score at one year but did not influence the ROM at either six weeks
or one year. Recovery from total knee replacement can be difficult to predict.
This study has identified psychological factors that play an important
role in recovery from surgery and functional outcome. These should
be taken into account when considering patients for total knee replacement. Cite this article:
The optimum cementing technique for the tibial
component in cemented primary total knee replacement (TKR) remains
controversial. The technique of cementing, the volume of cement
and the penetration are largely dependent on the operator, and hence
large variations can occur. Clinical, experimental and computational
studies have been performed, with conflicting results. Early implant
migration is an indication of loosening. Aseptic loosening is the
most common cause of failure in primary TKR and is the product of
several factors. Sufficient penetration of cement has been shown
to increase implant stability. This review discusses the relevant literature regarding all aspects
of the cementing of the tibial component at primary TKR. Cite this article:
Aims
Patients and Methods
We recovered 23 meniscal bearings from 18 failed bicompartmental Oxford knee prostheses. They had been implanted for one to nine years. The minimum thickness of the retrieved bearings was measured and compared with the thickness of 25 unused bearings. The mean penetration rate, calculated by two methods, was either 0.043 or 0.026 mm per annum. This compares with 0.19 mm per annum reported for the Charnley hip. The use of a fully congruous meniscal bearing prosthesis can reduce wear in
Aims . To investigate whether pre-operative functional mobility is a
determinant of delayed inpatient recovery of activities (IRoA) after
total
Substance P is readily detected in the synovial fluid of the knee in which it acts as a powerful inflammatory agent in response to injury and disease. It may be an objective predictor of pain after
We are entering a new era with governmental bodies
taking an increasingly guiding role, gaining control of registries,
demanding direct access with release of open public information
for quality comparisons between hospitals. This review is written
by physicians and scientists who have worked with the Swedish Knee
Arthroplasty Register (SKAR) periodically since it began. It reviews
the history of the register and describes the methods used and lessons
learned. Cite this article:
We have reviewed 85 knees in 71 patients after total-condylar posteriorly stabilised (Insall-Burstein)
Loosening is a serious problem in total arthroplasty and early detection of bone loss in the vicinity of an implant would help in its investigation. We present a method for the objective evaluation of bone adjacent to metallic implants in which a modified technique of quantitative computed tomography (QCT) is used to reconstruct cross-sectional images with few artefacts. We have used this technique in 19 patients with